Revision hip arthroplasty presents a challenge in the setting of femoral bone loss. Tapered stems are susceptible to subsidence which leads to leg length inequality,
Background:. External fixators are not as well tolerated around the femur when compared to the tibia. Lengthening with an intramedullary device is therefore attractive. Method:. We reviewed all cases of femoral lengthening performed at our unit from 2007 to 2014. Cases of non-unions, concurrent deformities, congenital limb deficiencies and lengthening with an
Slipped capital femoral epiphysiolysis (SCFE) is a rare condition with a unknown aetiopathogenesis. An early diagnosis and treatment is essential to minimize premature degeneration of the joint. The authors reviewed the cases treated between 1980 and 2005 in our institution. This study was aimed at evaluating patients with hip epiphysiolysis surgically treated by canullated screws or pinning and previously controlled by short-term follow-up, in order to evaluate radiographic medium/ long term evolution, looking for evidence of degenerative arthritis or femoroacetabular impingement. We performed a retrospective review of the clinical notes and radiographs of all patients with slipped upper femoral epiphysis who were surgically treated at our institution between January 1980 and December 2005. These patients performed radiographs to detect evidence of osteonecrosis, chondrolysis, degenerative arthritis or femoroacetabular impingment. To grade the radiological osteoarthritic changes the grading system of Kellgren and Lawrence was used. These changes were correlated with the existence of femoroacetabular impingement. The radiological results were correlated with the Loder'sclassification of stability and the morphological classification. 43 patients were reviewed, corresponding to 47 treated hips. AP and Lowenstein x-ray views were taken in all patients. The alfa angle and the head-shaft angle were measured in the Lowenstein view (frog-leg). Of 16 patients with impingement only 1 patient didn't present pistol grip deformity. 4 contralateral hips also presented the deformity. The mean alfa angle was 99,4. 43% of the patients with
To assess the stability of the hip after acetabular fracture, dynamic fluoroscopic stress views were taken of 41 acetabular fractures that met the criteria for non-operative management. These included roof arcs of 45°, a subchondral CT arc of 10 mm, displacement of less than 50% of the posterior wall, and congruence on the AP and Judet views of the hip. There were three