Introduction. Vitamin-E has been introduced into
The benefits of HXLPE in total knee arthroplasty (TKA) have not been as evident as total hip arthroplasty (THA). A systematic review and meta-analysis to assess the impact of
The purpose of this investigation is to assess the rate of wear the effect once the “bedding in period”/ poly creep had been eliminated. Creep is the visco-elastic deformation that polyethylene exhibits in the first 6–12 weeks. We also assessed the wear pattern of four different bearing couples in total hip arthroplasty (THA): cobalt-chrome (CoCr) versus oxidized zirconium (OxZir) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus
Total hip arthroplasty (THA) is one of the most successful and commonly performed surgical interventions worldwide. Based on registry data, at one-year post THA, implant survivorship is nearly 100% and patient satisfaction is 90%. A novel, porous coated acetabular implant was introduced in Europe and Australia in 2007. Several years after its introduction, warnings were issued for the system when used with metal-on-metal bearings due to adverse local tissue reaction, with one study reporting a 24% failure rate (Dramis et al. 2014). A subsequent 2018 study by Teoh et al. showed that the acetabular system had a survival rate of 98.9% at five years when used with conventional polyethylene or ceramic bearing surfaces. The current study was conducted to determine the safety and effectiveness of the acetabular system using standard
Recent issues related to trunionosis have created a new paradigm in choosing femoral head material in total hip arthroplasty. While many consider
Introduction. Over 40-years the dominant form of implant fixation has been bone cement (PMMA). However the presence of circulating PMMA debris represents a 3rd-body wear mechanism for metal-on-polyethylene (MPE). Wear studies using PMMA slurries represent tests of clinical relevance (Table 1). Cup designs now use many varieties of
Introduction:. Although commonly used, the clinical performance of highly crosslinked polyethylene in total knee arthroplasty (TKA) remains unknown and concerns exist regarding fatigue resistance and oxidation, particularly in posterior-stabilized (PS) designs. The purpose of this study is to compare highly crosslinked and conventional polyethylene in a PS TKA design at a minimum of 5-years. Methods:. A prospective cohort study of 114 consecutive TKAs in 83 patients was performed as a subset of a multi-center prospective study. All TKAs utilized an identical PS design. Conventional polyethylene inserts were used in 50 knees and second-generation highly cross-linked polythethylene inserts were implanted in 64 TKAs. All patients were followed with clinical outcome measures (Short-Form 36, Knee Society Scores, WOMAC and LEAS) and radiographically for a minimum of 5 years. Results:. The mean age of the highly cross-linked polyethylene group was 4 years less than the conventional group (p = 0.03). There was no difference in BMI (p = 0.3) or preoperative outcome measures between groups with numbers available. Seven patients died or were lost to follow up and one underwent revision for infection at 3 months postoperatively. 103 TKAs obtained minimum 5-year follow up. Mean Knee Society Scores were 12 points higher (p = 0.01) and 14 points higher (p = 0.005) in the physical function subset of the SF-36 in the highly cross-liked polyethylene group. There was no difference in the other outcome measures with the numbers available. There was no radiographic osteolysis or mechanical failures related to the tibial polyethylene in either group. Conclusion:. Mechanical failure or radiographic osteolysis was not observed with either conventional or highly cross-linked polyethylene in this PS TKA design at mid-term follow up. To our knowledge, this is the first minimum 5-year follow-up of highly cross-linked polyethylene in a posterior-stabilized design. While the results support comparative safety, longer-term follow-up is warranted to determine if wear resistance and mechanical properties of highly crosslinked polyethylene are maintained. Significance: Concerns regarding early fatigue failure and mechanical complications related to the PS post-cam articulation of
Introduction. Modular femoral necks have shown promising clinical results in total hip arthroplasty (THA) to optimize offset, rotation, and leg length. Given the wide variety of proximal femoral morphology, fine-tuning these kinematic parameters can help decrease femoroacetabular impingement, decrease wear rates and help prevent dislocations. Yet, additional implant junctions introduce additional mechanisms of failure. We present two patients who developed an abnormal soft tissue reaction consistent with a metal hypersensitivity reaction at a modular femoral neck/stem junction requiring revision arthroplasty. Methods. Two patients underwent THA for primary osteoarthritis with the same series of components: 50 mm shell, a 36 mm