Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 28 - 28
1 Apr 2012
Hýz M Aksu T ÜstündaÐ S Aksu N DerviþoÐlu S
Full Access

Aim. We investigated low grade intramedullary chondrosarcomas to see if curettage and cementation remains a strong alternative treatment to local resection. Methods. 39 patients with biopsy proven low grade chondrosarcoma treated with curettage and cementation in our clinic between 1993-2009. 32 were females and 7 were males. Mean age was 44. Mean follow up was 40.5 months. Anatomical localizations were 16 proximal humerus and 16 proximal femur, 6 distal femur and 1 proximal tibia. All patients had plain X-ray, CT scan, Tc99 bone scan and MRI before open biopsy. 28 patients had frozen intraoperative biopsy. Histological diagnosis were grade I chondrosarcoma in all our patients. Curettage followed by high speed burr and cementation with high viscosity bone cement was applied without any internal fixation. Active physiotherapy began after 2 days of the operation and full weight bearing is permitted at about 2 weeks later. Results. At 72.6 months follow up 2 patients (1 proximal humerus, 1 distal femur) developed local recurrence at 3rd month and converted to local wide excision and reconstruction with tumour prosthesis. No infection occurred in the series. All patients followed by plain X-rays and if needed CT or MRI every third month in the first year and every fourth month at the second year and 6 months thereafter. Chest CT scans obtained at every 6 months for two years. No patient developed distant metastasis including recurrence cases. Conclusion. Curettage and cementation in the treatment of low grade chondrosarcomas with a local recurrence rate of 5.1 percent proved itself as a safe and function sparing surgical method. Recurred patients turned out to be Grade II chondrosarcoma at the re-examination of resected specimens. Recurrences could be easily detected around bone cement and prompt resection with prosthetic replacement seemed to be effective


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 267 - 275
1 Feb 2017
Liang H Ji T Zhang Y Wang Y Guo W

Aims

The aims of this retrospective study were to report the feasibility of using 3D-printing technology for patients with a pelvic tumour who underwent reconstruction.

Patients and Methods

A total of 35 patients underwent resection of a pelvic tumour and reconstruction using 3D-printed endoprostheses between September 2013 and December 2015. According to Enneking’s classification of bone defects, there were three Type I lesions, 12 Type II+III lesions, five Type I+II lesions, two Type I+II+III lesions, ten type I+II+IV lesions and three type I+II+III+IV lesions. A total of three patients underwent reconstruction using an iliac prosthesis, 12 using a standard hemipelvic prosthesis and 20 using a screw-rod connected hemipelvic prosthesis.