Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 621 - 624
1 May 2019
Pumberger M Bürger J Strube P Akgün D Putzier M

Aims. During revision procedures for aseptic reasons, there remains a suspicion that failure may have been the result of an undetected subclinical infection. However, there is little evidence available in the literature about unexpected positive results in presumed aseptic revision spine surgery. The aims of our study were to estimate the prevalence of unexpected positive culture using sonication and to evaluate clinical characteristics of these patients. Patients and Methods. All patients who underwent a revision surgery after instrumented spinal surgery at our institution between July 2014 and August 2016 with spinal implants submitted for sonication were retrospectively analyzed. Only revisions presumed as aseptic are included in the study. During the study period, 204 spinal revisions were performed for diagnoses other than infection. In 38 cases, sonication cultures were not obtained, leaving a study cohort of 166 cases. The mean age of the cohort was 61.5 years (. sd. 20.4) and there were 104 female patients. Results. Sonication cultures were positive in 75 cases (45.2%). Hardware failure was the most common indication for revision surgery and revealed a positive sonication culture in 26/75 cases (35%) followed by adjacent segment disease (ASD) in 23/75 cases (30%). Cutibacterium acnes and Staphylococcus epidermidis were the most commonly isolated microorganisms, observed in 45% and 31% of cases, respectively. C. acnes was isolated in 65.2% of cases when the indication for revision surgery was ASD. Conclusion. Infection must always be considered as a possibility in the setting of spinal revision surgery, especially in the case of hardware failure, regardless of the lack of clinical signs. Sonication should be routinely used to isolate microorganisms adherent to implants. Cite this article: Bone Joint J 2019;101-B:621–624


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 976 - 983
3 May 2021
Demura S Kato S Shinmura K Yokogawa N Shimizu T Handa M Annen R Kobayashi M Yamada Y Murakami H Kawahara N Tomita K Tsuchiya H

Aims. To evaluate the perioperative complications associated with total en bloc spondylectomy (TES) in patients with spinal tumours, based on the extent and level of tumour resection. Methods. In total, 307 patients who underwent TES in a single centre were reviewed retrospectively. There were 164 male and 143 female patients with a mean age at the time of surgery of 52.9 years (SD 13.3). A total of 225 patients were operated on for spinal metastases, 34 for a malignant primary tumour, 41 for an aggressive benign tumour, and seven with a primary of unknown origin. The main lesion was located in the thoracic spine in 213, and in the lumbar spine in 94 patients. There were 97 patients who underwent TES for more than two consecutive vertebrae. Results. Major and minor perioperative complications were observed in 122 (39.7%) and 84 (27.4%) patients respectively. The breakdown of complications was as follows: bleeding more than 2,000 ml in 60 (19.5%) patients, hardware failure in 82 (26.7%), neurological in 46 (15.0%), surgical site infection in 23 (7.5%), wound dehiscence in 16 (5.2%), cerebrospinal fluid leakage in 45 (14.7%), respiratory in 52 (16.9%), cardiovascular in 11 (3.6%), digestive in 19 (6.2%)/ The mortality within two months of surgery was four (1.3%). The total number of complications per operation were 1.01 (SD 1.0) in the single vertebral resection group and 1.56 (SD 1.2) in the group with more than two vertebral resections. Cardiovascular and respiratory complications, along with hardware failure were statistically higher in the group who had more than two vertebrae resected. Also, in this group the amount of bleeding in patients with a lumbar lesion or respiratory complication in patients with a thoracic lesion, were statistically higher. Multivariate analysis showed that using a combined anterior and posterior approach, when more than two vertebral resections were significant independent factors. Conclusion. The characteristics of perioperative complications after TES were different depending on the extent and level of the tumour resection. In addition to preoperative clinical and pathological factors, it is therefore important to consider these factors in patients who undergo en bloc resection for spinal tumours. Cite this article: Bone Joint J 2021;103-B(5):976–983


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_1 | Pages 1 - 1
23 Jan 2023
Cottam A Van Herwijnen B Davies EM
Full Access

We present a large single surgeon case series evaluation of a new growth guidance technique for the treatment of progressive early onset scoliosis (EOS). A traditional Luque trolley construct uses wires to hold growth guidance rods together. We describe a new technique that uses domino end to side connectors in place of the wires with the aim of providing a stronger construct to better limit curve progression, while allowing longitudinal growth. We did a thorough retrospective review of patient records and radiological imaging. Sequential measurements of Cobb angle and length of rods were recorded, as well as any further surgical procedures and associated complications. This enabled us to quantify the ability of a technique to limit curve progression and simultaneously allow growth of the construct. In total, 28 patients with EOS (20 idiopathic, four syndromic, and four neuromuscular) have been treated with this technique, 25 of whom have a minimum follow-up of 2 years and 13 have a minimum follow-up of 5 years. The average correction of the preoperative Cobb angle was 48.9%. At the 2-year follow up, the average loss of this initial correction was 15 degrees, rising to only 20 degrees at a minimum of 5 years (including four patients with a follow-up of 8 years or more). The growth of the constructs was limited. The average growth at 2 years was 3.7 mm, rising to 19 mm at the 5-year follow-up. Patients who underwent surgery with this technique before the age of 8 years seemed to do better. This group had a revision rate of only 18% at an average time of 7 years after the index procedure, and the average growth was 22 mm. However, the group that had index surgery after the age of 8 years had a 64% revision rate at an average of 3.2 years after surgery and an average growth of only 11.6 mm. Overall, in the cases series, there were four hardware failures (14%) and one deep infection (3.5%), and only ten patients (36%) had one extra surgery after the index procedure. Only two of the 13 patients who are at a follow-up of 5 years or more have had revision. This modified Luque trolley technique has a good capacity for initial curve correction and for limiting further curve progression, with limited longitudinal growth before 2 years and improved growth thereafter. This technique might not be so useful after the age of 8 years because of poor growth and a higher early revision rate. We have also demonstrated a low cost technique with a low hardware failure rate that saves many future surgeries for the patient compared with other techniques used in the treatment of EOS


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1249 - 1255
1 Nov 2022
Williamson TK Passfall L Ihejirika-Lomedico R Espinosa A Owusu-Sarpong S Lanre-Amos T Schoenfeld AJ Passias PG

Aims

Postoperative complication rates remain relatively high after adult spinal deformity (ASD) surgery. The extent to which modifiable patient-related factors influence complication rates in patients with ASD has not been effectively evaluated. The aim of this retrospective cohort study was to evaluate the association between modifiable patient-related factors and complications after corrective surgery for ASD.

Methods

ASD patients with two-year data were included. Complications were categorized as follows: any complication, major, medical, surgical, major mechanical, major radiological, and reoperation. Modifiable risk factors included smoking, obesity, osteoporosis, alcohol use, depression, psychiatric diagnosis, and hypertension. Patients were stratified by the degree of baseline deformity (low degree of deformity (LowDef)/high degree of deformity (HighDef): below or above 20°) and age (Older/Younger: above or below 65 years). Complication rates were compared for modifiable risk factors in each age/deformity group, using multivariable logistic regression analysis to adjust for confounders.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 67 - 67
1 Apr 2012
Kabir S Casey A
Full Access

To describe a modification of the existing technique for C2 translaminar screw fixation that can be used for salvage in difficult cases. Bilateral crossing C2 laminar screws have recently become popular as an alternative technique for C2 fixation. This technique is particularly useful in patients with anomalous anatomy, as a salvage technique where other modes of fixation have failed or as a primary procedure. However, reported disadvantages of this technique include breach of the dorsal lamina and spinal canal, early hardware failure and difficulty in bone graft placement due to the position of the polyaxial screw heads. To address some of these issues, a modified technique is described. In this technique, the upper part of the spinous process of C2 is removed and the entry point of the screw is in the base of this removed spinous process. From October 2008 to March 2009, 6 patients underwent insertion of unilateral translaminar screws using our technique. The indications were: basilar invagination(three cases), C1/C2 fracture (two cases), tumour (one case). Age varied from 22 to 81 years (mean 48 years). All patients had post-operative x-ray and CT scan to assess position of the screws. Mean follow-up was 6 months. The screw position was satisfactory in all patients. There were no intraoperative or early postoperative complications. Our modification enables placement of bone graft on the C2 lamina and is also less likely to cause inadvertent cortical breach. Because of these advantages, it is especially suitable for patients with advanced rheumatoid arthritis with destruction of the lateral masses of C2 or as part of a hybrid construct in patients with unilateral high riding vertebral artery. This technique is not suitable for bilateral translaminar screw placement


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 899 - 903
1 Jul 2020
Bürger J Palmowski Y Strube P Perka C Putzier M Pumberger M

Aims

To evaluate the histopathological examination of peri-implant tissue samples as a technique in the diagnosis of postoperative spinal implant infection (PSII).

Methods

This was a retrospective analysis. Patients who underwent revision spinal surgery at our institution were recruited for this study. PSII was diagnosed by clinical signs, histopathology, and microbiological examination of intraoperatively collected samples. Histopathology was defined as the gold standard. The sensitivity for histopathology was calculated. A total of 47 patients with PSII and at least one microbiological and histopathological sample were included in the study.