Graft-tunnelmismatch of the bone-patellar tendon-bone
(BPTB) graft is a major concern during anatomical anterior cruciate
ligament (ACL) reconstruction if the femoral tunnel is positioned
using a far medial portal technique, as the femoral tunnel tends
to be shorter compared with that positioned using a transtibial
portal technique. This study describes an accurate method of calculating
the ideal length of bone plugs of a BPTB graft required to avoid
graft–tunnel mismatch during anatomical ACL reconstruction using
a far medial portal technique of femoral tunnel positioning. Based on data obtained intra-operatively from 60 anatomical ACL
reconstruction procedures, we calculated the length of bone plugs
required in the BPTB graft to avoid graft–tunnel mismatch. When
this was prevented in all the 60 cases, we found that the mean length
of femoral bone plug that remained in contact with the interference
screw within the femoral tunnel was 14 mm (12 to 22) and the mean
length of tibial bone plug that remained in contact with the interference
screw within the tibial tunnel was 23 mm (18 to 28). These results
were used to validate theoretical formulae developed to predict
the required length of bone plugs in BPTB graft during anatomical
ACL reconstruction using a far medial portal technique. Cite this article: Bone Joint J 2015;97-B:324–8
The purpose of this study was to determine the incidence of graft-tunnelmismatch (GTM) when performing anatomic anterior cruciate ligament reconstruction (ACLR) using bone-patella tendon-bone (BPTB) grafts and anteromedial portal drilling. Beginning in November 2018, 100 consecutive patients who underwent ACLR by two sports fellowship-trained, orthopedic surgeons using BPTB autograft and anteromedial portal drilling were prospectively identified. The BPTB graft dimensions and the femoral tunnel distance, tibial tunnel distance, intra-articular distance, and total distance were measured. Surgeons determined the depth and angle of tunnels based on the patella tendon graft length dimensions in each case. After passage of the graft, the distance from the distal graft tip to the tibial cortex aperture was measured. GTM was defined as the need for additional measures to obtain satisfactory tibial graft fixation (< 1 5e20 mm of bone fixation). The incidence of mismatch was 6/100 (6%). Five cases involved the graft being too long, with the tibial bone plug protruding excessively from the tibial tunneld4/5 had a patella tendon length ? 50 mm. Three cases were managed with femoral tunnel recession, and two were treated with a free bone plug technique. One patient with a patella tendon length of 35 mm had a graft that was too short, with the tibial bone plug recessed in the tibial tunnel. Of patients whose tibial tunnel distance was within 5 mm of the patella tendon length, only 1/46 (2%) patients had mismatch, whereas 5/54 (9%) of patients who had >5 mm difference had mismatch. The incidence of grafttunnel mismatch after anatomic ACLR using BTPB and anteromedial portal drilling in this study is 6%. To limit the occurrence of GTM where the graft is too long, surgeons should drill tibial tunnel distances within 5 mm of the patella tendon length