We report our five-year
We aim to show that our series of Avon Patellofemoral Joint Replacements (APFJR) with over 5 year follow up, have comparable functional, radiological and revision rate results to other published reports. Retrospective analysis occurred of all consecutive cases of APFJR from October 1999 and January 2010. All operations were performed by the senior author (AL). Each patient had both clinical and radiological follow up. Patient demographics, pre and post op Oxford Knee scores and complications were all recorded. An independent post operative radiological review took place to check for loosening and progression of disease. Revision to Total Knee Replacement (TKR) was taken as the endpoint.Aim
Methods
Introduction. Reconstruction of large defect of tibia following infection is considered as one of the most difficult problem facing the orthopaedic surgeon. Amputation with modern prosthetic fitting is a salvage procedure to treat big defects, which gives a
Abstract. Background. Extracorporeal radiation therapy (ECRT) has been reported as an oncologically safe and effective reconstruction technique for limb salvage in diaphyseal sarcomas with promising
Acromioclavicular joint (ACJ) dislocations is a common disorder amongst our population for which numerous techniques have been described. It is thought that by using this novel technique combining a CC and AC repair with a reconstruction will result in high maintenance of anatomical reduction and
Abstract. Background. Multi-ligament knee injury is a rare but severe injury. Treatment strategies are challenging for most orthopedic surgeons & optimal treatment remains controversial. The purpose of our study was to assess clinico-radiological and functional outcomes after surgical management of multi-ligament knee injuries & to determine factors that could predict outcome of surgery. Materials And Method. It is a prospective observational study of 30 consecutive patients of Multi-ligament knee injury conducted between 2018–2020. All patients were treated surgically with single-stage reconstruction of all injured ligaments and followed standardized postoperative rehabilitation protocol. All patients were evaluated for Clinical (VAS score, laxity stress test, muscle-strength, range of motion), Radiological (stress radiographs) & Functional (Lysholm score) outcomes three times-preoperatively, post-operative 3 & 12 months. Results. At final follow up mean VAS score was 0.86±0.77. The anteroposterior & valgus-varus stress test showed ligament laxity >10mm (GradeD) in 93.3% patient which improved to <3mm (normal, GradeA) in 90% patients. Most patients (83.3%) had preoperative-range <100° and muscle strength of MRC Grade-3 which improved to >120° and muscle strength of MRC grade-5 at final followup. Lysholm score was poor (<64) in all patients preoperatively and improved to good (85–94) in 73.3%, excellent (>95) in 20% & fair (65–84) in 6.6% patients. The stress radiographs showed stable results for anterior/posterior & varus/valgus stress. All patients returned to their previous work. Factors that could predict outcomes of surgery are age, timing of surgery, type of surgery & associated injury. Conclusion. Early complete single stage reconstruction can achieve good
Avulsion of the proximal hamstring tendon from the ischial tuberosity is an uncommon but significant injury. Recent literature has highlighted that
Background. Acute soft tissue defects (wound dehiscence or necrosis) after a total knee arthroplasty (TKA) may be the cause of the devasting complication of deep infection. When a medium (4–6cm) defect is present, in patellar or infra-patellar localization, a medial hemi-gastrocnemius flap is widely used to cover it, because of its low morbidity and high
Introduction. Deformations of forearm with different degree of expression and functional restrictions of upper limb in children with hereditary multiple exostosis are formed in almost 80% of the cases. The question of indications for the selection and conduct of surgical procedure remains controversial, existing treatment methods and post-operative recovery methods for children need to be improved. Materials and Methods. The long-term outcomes of surgical treatment of 112 patients diagnosed with “Hereditary Multiple Exostosis” (HME) aged from 2 till 17 years old were researched. Evaluation of surgical treatment results was carried out in accordance with complaints, functional condition of the forearm, radiographs (taking into account reference lines and angles). Depending on the variant of deformation, the following surgical operations were performed: resection of bone-cartilage exostoses (in 20.5%); correction of forearm deformation with external fixator (in 79.5). In 14 cases, for a more accurate correction of deformity a hexapod frame was used. Results. Differentiated approach provided “good” anatomical and
Aim. Reconstruction of composite soft-tissue defects with extensor apparatus deficiency in patients with periprosthetic joint infection (PJI) of the knee is challenging. We present a single-centre multidisciplinary orthoplastic treatment concept based on a retrospective outcome analysis over 20 years. Method. One-hundred sixty-seven patients had PJI after total knee arthroplasty. Plastic surgical reconstruction of a concomitant perigenicular soft-tissue defect was indicated in 49 patients. Of these, seven presented with extensor apparatus deficiency. Results. One patient underwent primary arthrodesis and six patients underwent autologous reconstruction of the extensor apparatus. The principle to reconstruct missing tissue ‘like with like’ was thereby favoured: Two patients with a wide soft-tissue defect received a free anterolateral thigh flap with fascia lata; one patient with a smaller soft-tissue defect received a free sensate, extended lateral arm flap with triceps tendon; and three patients received a pedicled medial sural artery perforator gastrocnemius flap, of which one with Achilles tendon. Despite good
Radial head fractures are common and mainly require a functional conservative treatment. About 20% of patients will present an unsatisfactory final
Introduction. Pilon fractures are complex, high-energy, intra-articular fractures of the distal tibia. Achieving good outcomes is challenging due to fracture complexity and extensive soft tissue damage. The purpose of this study was to determine the long-term functional and clinical outcomes of definitive management with fine wire Ilizarov fixation for closed pilon fractures. Materials and Methods. 185 patients treated over a 14-year period (2004–2018) were included. All patients had Ilizarov frames applied to restore mechanical axis and fine wires to control periarticular fragments. CT scans were performed post operatively to confirm satisfactory restoration of the articular surface. All frames were dynamized prior to removal. Patients' functional outcome was assessed using the validated Chertsey Outcome Score for Trauma (“COST”). Review of clinical notes and imaging was used to determine complications and time to union. Results. The mean functional outcome in the studied cohort was determined to be “average” on the “COST” score. Poorer functional outcomes were associated with younger age at time of injury and multi-fragment fracture patterns. Mean time in frame was 170 days. Complication rates were low. There were no deep infections, no amputations and only 8 patients went on to have ankle fusions. Conclusions. Good
INTRODUCTION. Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes. METHODS. Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests. RESULTS. No significant differences were observed for the flexion/extension maneuver between the 38mm and 42mm liner sizes, but a significant difference was observed for every internal/external rotation assessment at 0°, 45°, and 90° of abduction. No significant differences were observed for the across the body and overhead maneuvers, but a significant difference was observed for the behind the back maneuver (p = 0.015). Standard deviations were pronounced across all maneuvers. CONCLUSION. This study observed significant differences in intraoperative load values in rTSA when comparing different humeral liner sizes. Limitations of this study include the small sample sizes and large standard deviations observed, as well as comparing across multiple patients and multiple surgeons. Area for future work includes comparing load values with postoperative
Myxoid or Myxoid Round Cell liposarcoma (MLS) is a mesenchymal malignancy with adipocyte differentiation accounting for 15–20% of liposarcomas and 5% of all adult soft tissue sarcomas (STS). Like other STS, treatment of MLS is generally by wide surgical resection in conjunction with radiotherapy and this approach is associated with low rates of local recurrence [1]. However, most MLS are located between muscles so wide local excision(WLE) can be quite morbid with adverse
Introduction and Purposes. Custom made acetabular prosthesis are a valid option for the reconstruction after the resection of pelvic tumors. They should guarantee a stable and reliable reconstruction for the expected survival of the patient. Nevertheless in many cases periacetabular metastatic lesions have been compared to high grade (IIIA-B) Paprosky defects, but treated with low or intermediate longevity implants. Some complex post-traumatic scenarios or total hip arthroplasty (THA) multiple failures need a reconstruction according to oncologic criteria to fill in the huge defect and to obtain an acceptable function. The aim of the study is to compare 3D custom-made implants for tumors and for THA failures. Materials and Methods. Three custom-made implants after tumor resection (group A: 1 chondroblastic osteosarcoma, 1 bifasic synovialsarcoma, 1 high grade chondrosarcoma) were evaluated and compared to 3 acetabular complex reconstructions after non-oncologic bone defect (group B: 3 cases of aseptic loosening after at least 2 revisions). All the implants were case-based designed, 3D printed, and realized with porous or trabecular surfaces on a Titanium base prosthesis. Age range 16–70 ys in oncologic patients and 60–75 ys in non-oncologic patients. The bone defect to be reconstructed after tumor resection was classified according to Enneking zones (1 type 1-2-3 resection, 1 type 2 resection, 1 partial type 2 resection). Non-oncologic cases were comparable in term of remaining bone stock and classified according to Paprosky classification for acetabular defects as 1 type IIIA an 2 type IIIB. Complications, MSTS functional score, necessity of walking-aids were evaluated at minimum follow up of 1 year. Results. In both groups, good
The aim of an anterior cruciate ligament (ACL) reconstruction is to regain functional stability of the knee following ACL injury, ideally allowing patients to return to their pre-injury level of activity. The purpose of this study was to assess clinical, functional and patient-reported outcomes following primary ACL reconstruction with hamstring autograft. A prospective case-series design (n=1610) was used to gather data on post-operative ACL graft laxity, functional testing performance and scores on the ACL quality of life (ACL-QOL) questionnaire. Demographic data were collected for all patients. Post-operative ACL laxity assessment using the Lachman and Pivot-shift tests was completed independently on each patient by a physiotherapist and an orthopaedic surgeon at the 6-, 12- and 24-months post-operative appointments. A battery of functional tests was also assessed including single leg Bosu balance, and 4 single-leg hop tests. The hop tests provided a comparative assessment of limb-to-limb function. Patients completed the ACL-QOL at all time points. The degree and frequency of post-operative laxity was calculated. A Spearman's rank correlation matrix was undertaken to assess for relationships between post-operative laxity, functional test performance, and the ACL-QOL scores. A linear regression model was used to assess for relationships between the ACL-QOL scores, as well as the
Aim. In surgeries on patients with advanced ligament instabilities or severe bone defects modern-generation of rotating hinged knee prostheses are one of the main options. The objective of our study is to evaluate the mid-term
Aim. The purpose of this study is to evaluate the safety profile and impact on
Introduction. Total shoulder replacement is a successful treatment for gleno-humeral osteoarthritis. However, components loosening and painful prostheses, related to components wrong positioning, are still a problem for those patients who underwent this kind of surgery. CT-based intraoperative navigation system is a suitable option to improve accuracy and precision of the implants as previously described in literature for others district. Method. Eleven reverse shoulder prostheses were performed at Modena Polyclinic from October 2018 to April 2019 using GPS CT-based intraoperative navigation system (Exactech, Gainsville, Florida). In the preoperative planning, Walch classification was used to assess glenoid type. The choice of inclination of the glenoid component, the screw length, as well as the inclination of the reamer was study and recorded using specific software using the CT scan of shoulder of each patient (Fig.1, Fig.2). Intraoperative and perioperative complications were recorded. Three patients were male, eight were female. Mean age was 72 years old (range 58=84). Three glenoid were type B2, six cases were B1, two case were type C1. Results. In all cases treated by reverse shoulder prostheses we had obtain good
Introduction. Upper femoral fractures include intra and extra-capsular fracture (ECF). For intra-capsular fracture (ICF), hemi-arthroplasty (HA) is the most commonly used treatment. Interest in total hip arthroplasty (THA) is growing because THA yields less revision (4% versus 7%) associated to better