Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 66 - 66
1 Jun 2012
König MA Jehan S Balamurali G Seidel U Heini P Boszczyk BM
Full Access

Introduction. Isolated U-shaped sacral fractures are rare entities, mostly seen in polytraumatized patients, and hence, they are difficult to diagnose. While the pelvic ring remains intact across S2/S3, the U-shaped fracture around S1 leads to marked instability between the base of the spine and the pelvis. As severe neurological deficits can occur, timely treatment of these fractures is crucial. We present a novel technique of percutaneous reduction and trans-sacral screw fixation in U-shaped fractures. Material and Methods. 3 multiply injured patients with u-shaped sacral fractures (female, age 21.7±7.23). Two underwent immediate fracture fixation. In the third case delayed reduction and fixation was performed after referral 6 weeks following open decompression. In prone position, a pair of Schanz pins was inserted into pelvis at the PSIS. A second pair of Schanz pins was inserted into S1 or L5. All pins were inserted percutaneously. The fracture was reduced indirectly, using the Schanz pins as levers. After image intensifier control of the reduction result, two trans-sacral screws were inserted for finite fixation. Results. In all three cases, this novel method of percutaneous reduction allowed an anatomical sacral alignment and stabilization with trans-sacral screws was initially sufficient. At 1 year follow-up, both immediately fixed fractures showed an anatomical sacral alignment. Both had no neurological deficits, no signs of screw-loosening and were pain free. Unfortunately the delayed fixation showed a new tilt and hence loss of sacral alignment. This might be due to posterior structural integrity loss after decompression. Conclusion. U-shaped sacral fractures are rare, but correct and immediate treatment is paramount to achieve good outcome. Percutaneous reduction and screw fixation offers a less invasive treatment method. Anatomical alignment and stabilisation is possible and time of surgery can be reduced significantly


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 472 - 477
1 May 1999
Henry AD Bohly J Grosse A

We have reviewed 81 patients with fractures of the odontoid process treated between May 1983 and July 1997, by anterior screw fixation. There were 29 patients with Anderson and D’Alonzo type-II fractures and 52 with type III. Roy-Camille’s classification identified the direction and instability of the fracture. Operative fixation was carried out on 48 men and 33 women with a mean age of 57 years. Associated injuries of the cervical spine were present in 15 patients, neurological signs in 13, and 18 had an Injury Severity Score of more than 15. Nine patients died and 11 were lost to follow-up. Of 61 patients, 56 (92%) achieved bony union at an average of 14.1 weeks. Two patients required a secondary posterior fusion after failure of the index operation. A full range of movement was restored in 43 patients; only six had a limitation of movement greater than 25%. We conclude that anterior screw fixation is effective and practicable in the treatment of fractures of the dens


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 98 - 102
1 Jan 2010
Lattig F Fekete TF Jeszenszky D

Fracture of a pedicle is a rare complication of spinal instrumentation using pedicular screws, but it can lead to instability and pain and may necessitate extension of the fusion. Osteosynthesis of the fractured pedicle by cerclage-wire fixation and augmentation of the screw fixation by vertebroplasty or temporary elongation of the fixation, allows stabilisation without sacrifice of the adjacent healthy segment. We describe three patients who developed a fracture of the pedicle in the most caudal instrumented vertebra early after lumbar spinal fusion.

During revision surgery the pedicles were reduced and secured by a soft cerclage wire bilaterally. Fusion was obtained at the site of the primary instrumentation and healing of the pedicles was achieved. Cerclage wiring of the fractured pedicle seems to be safe and avoids permanent extension of the fusion without the sacrifice of an otherwise healthy segment.