Jacxsens M Schmid J Zdravkovic V Jost B Spross C

Aims. In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries. Patients and Methods. Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up. Results. In 100 patients (59 female, 41 male; mean age 57 years), 91 of the fractures (91%) remained stable. In five of nine patients (55%) with secondary displacement, surgery was recommended. Comminution, present in 23 patients (23%), was identified as a predictor of secondary displacement (p < 0.001). Patients’ age, sex, fracture configuration, and bone quality were not associated with secondary displacement (p ≥ 0.438). Nonoperative treatment resulted in a mean absolute Constant score (CS) of 80 (49 to 98), relative CS of 101% (63% to 138%), median subjective shoulder value of 95% (interquartile range (IQR) 90% to 100%), and median EuroQol five-dimensional questionnaire score of 0.89 (IQR 0.80 to 1.00) with bone union in all cases at one-year follow-up. Conclusion. Radiological re-evaluation was only necessary in patients presenting with comminution and may be redundant for 77% of patients with one-part proximal humerus fractures. Nonoperative treatment of one-part proximal humerus fractures remains the mainstay of treatment with a low rate of secondary surgery, a high union rate, and good clinical results. Cite this article: Bone Joint J 2019;101-B:1307–1312


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 62 - 62
1 Apr 2013
Moazen M Mak JH Etchels L Jones AC Jin Z Wilcox RK Tsiridis E
Full Access

There are a number of periprosthetic femoral fracture (PFF) fixation failures. In several cases the effect of fracture configuration on the performance of the chosen fixation method has been underestimated. As a result, fracture movement within the window that seems to promote callus formation has not been achieved and fixations ultimately failed. This study tested the hypothesis that: PFF configuration and the choice of plate fixation method can be detrimental to healing. A series of computational models were developed, corroborated against measurements from a series of instrumented laboratory models and in vivo case studies. The models were used to investigate the fixation of different fracture configurations and plate fixation parameters. Surface strain and fracture movement were compared between the constructs. A strong correlation between the computational and experimental models was found. Computational models showed that unstable fracture configurations increase the stress on the plate fixation. It was found that bridging length plays a pivotal role in the fracture movement. Rigid fixations, where there is clinical evidence of failure, showed low fracture movement in the models (<0.05mm); this could be increased with different screw and plate configurations to promote healing. In summary our results highlighted the role of fracture configuration in PFF fixations and showed that rigid fixations that suppress fracture movement could be detrimental to healing


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 5 - 5
1 May 2013
Dalgleish S Finlayson D Cochrane L Hince A
Full Access

Radiation exposure is a hazard to orthopaedic surgeons, theatre staff and patients intra-operatively. Obesity is becoming a more prevalent problem worldwide and there is little evidence how a patient's body habitus correlates with the radiation doses required to penetrate the soft tissues for adequate imaging. We aimed to identify if there was a correlation between Body Mass Index (BMI) and radiation exposure intra-operatively. We performed a retrospective review of 75 patients who underwent sliding hip screw fixation for femoral neck fractures in one year. We recorded Body Mass Index (BMI), screening time, dose area product (DAP), American Society of Anesthesiologists (ASA) grade, seniority of surgeon and complexity of the fracture configuration. We analysed the data using statistical tests. We found that there was a statistically significant correlation between dose area product and patient's BMI. There was no statistically significant relationship between screening time and BMI. There was no statistical difference between ASA grade, seniority of surgeon, or complexity of fracture configuration and dose area product. Obese patients are exposed to increased doses of radiation regardless of length of screening time. Surgeons and theatre staff should be aware of the increased radiation exposure during fixation of fractures in obese patients and, along with radiographers, ensure steps are taken to minimise these risks


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 69 - 76
1 Jan 2024
Tucker A Roffey DM Guy P Potter JM Broekhuyse HM Lefaivre KA

Aims

Acetabular fractures are associated with long-term morbidity. Our prospective cohort study sought to understand the recovery trajectory of this injury over five years.

Methods

Eligible patients at a level I trauma centre were recruited into a longitudinal registry of surgical acetabular fractures between June 2004 and August 2019. Patient-reported outcome measures (PROMs), including the 36-Item Short Form Health Survey (SF-36) physical component summary (PCS), were recorded at baseline pre-injury recall and six months, one year, two years, and five years postoperatively. Comparative analyses were performed for elementary and associated fracture patterns. The proportion of patients achieving minimal clinically important difference (MCID) was determined. The rate of, and time to, conversion to total hip arthroplasty (THA) was also established.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 452 - 456
1 Jun 2024
Kennedy JW Rooney EJ Ryan PJ Siva S Kennedy MJ Wheelwright B Young D Meek RMD

Aims

Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures.

Methods

We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1266 - 1272
1 Nov 2022
Farrow L Brasnic L Martin C Ward K Adam K Hall AJ Clement ND MacLullich AMJ

Aims

The aim of this study was to examine perioperative blood transfusion practice, and associations with clinical outcomes, in a national cohort of hip fracture patients.

Methods

A retrospective cohort study was undertaken using linked data from the Scottish Hip Fracture Audit and the Scottish National Blood Transfusion Service between May 2016 and December 2020. All patients aged ≥ 50 years admitted to a Scottish hospital with a hip fracture were included. Assessment of the factors independently associated with red blood cell transfusion (RBCT) during admission was performed, alongside determination of the association between RBCT and hip fracture outcomes.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 26 - 26
1 May 2015
McKenna R Breen N Madden M Andrews C McMullan M
Full Access

Background:. Developing a successful outpatient service for Ilizarov frame removal provides both patient and cost benefits. Misinformation and patient trepidation can be detrimental to recovery and influence choices. Education may play an important role in tailoring an efficacious service. Objective:. Review Belfast Regional Limb Reconstruction frame removal practice, introduce changes aimed at improving care and evaluate effects. Methods:. 1 year retrospective review of Ilizarov frame removal. Evaluation of service prior to and following provision of a new patient information leaflet, alongside a test wire removal technique. Subsequent service evaluation supplemented via patient reported feedback questionnaire. Results:. Retrospectively 85% Ilizarov frames removed in clinic, 54% required Entonox. Annual cost £19000. 46% patients unaware of process, gathering information from unprofessional sources. General anaesthetic and analgesic requirements related to psychosocial influences; no correlation between fracture configuration, elective reconstructive cases and operative techniques. Prospectively 96% patients found information leaflet educational and beneficial. 87% Ilizarov frames removed in clinic. 100% patients who had outpatient removal recommend this method. Entonox use reduced to 15% with average pain score 4.6/10 without analgesia. Patients felt happier. Projected annual cost savings £3000. 100% rated service excellent. Discussion:. Professional education and a standardised outpatient removal process for Ilizarov frames, delivered by a dedicated specialist team, reduces morbidity and positively impacts service provision


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_V | Pages 4 - 4
1 Mar 2012
Karuppiah S Downing M Broadbent R Christie M Carnegie C Ashcroft G Johnstone A
Full Access

Due to its popularity of intramedullary nails (IMN) high success rate, newer design (titanium) IMN system have been introduced to replace stainless steel system. However the stability provided by the titanium IMN. may not be adequate, there by influencing the union rate. We aimed to compare the results of both IMN systems via prospective clinical study and biomechanical testing using RSA. Biomechanical study. This study was done in an experimental set-up which consisted of a physically simulated femoral shaft fractures models fixed with a stainless steel (Russell Taylor) or Titanium (Trigen) IM nailing system. Two common fracture configurations with stimulated weight bearing conditions were used and the axis of fragment movements recorded. Clinical study. The data on two groups of patients were collected as part of a prospective cohort study. Details of the implant, such as size of nail, cross screw lengths, screw thickness, etc. was collected. Patients were followed up for a minimum of 4 months and details of clinical complications recorded. Biomechanical study. The degree of translation movement in comminuted fracture, using titanium IMN system, was 6 times more compared to stainless steel IMN system. Clinical study. The results show that there is a 5.7% of non union and 14% hardware problems with titanium based IMN system when compared to 2.2% non union in the stainless steel IMN system. Titanium based IM nailing system have a potential to inherent mechanical instability when used to treat comminuted fractures. This may explain some of the clinically observed delayed or non-union of femoral fractures


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 346 - 346
1 Sep 2012
Baliga S Carnegie C Johnstone A
Full Access

Introduction. Several clinical and radiological studies have confirmed the benefits of using Volar Locking Plates (VLPs) to treat unstable distal radius fractures. The “theoretical” advantage of VLPs compared to standard plate fixation is that VLPs, through their design, intrinsically provide angular stability for most fracture configurations including comminuted fractures and, quite possibly, osteoporotic fractures. However few studies have compared the clinical results of patients of different ages who have been treated using VLPs. Aim. The aim of this study was to compare the clinical outcomes of VLP fixation of displaced distal radius in younger (<59 yrs) and older (>60yrs) patients. Patients & Methods. We reviewed 78 consecutive patients who had undergone ORIF of their displaced distal radial fractures using a VLP. All patients were reviewed at predetermined time points by an independent observer and the findings at 6 months are presented. In addition to documenting the standard demographics for each patient and classifying the fractures using the OTA/AO system, wrist function was assessed using Range of Movement (ROM), Grip strength (GS), the Modified Gartland & Werley score (MGWS), the Patient Rated Wrist Evaluation (PRWE), the Quick DASH scores, and overall scores of wrist Pain and Function using Visual Analogue Scores (VAS). Results. 43 patients were under 60 years of age and 35 patients were 60 years or over. The proportion of extra-articular to intra-articular fractures were similar for both age groups. There was little difference in terms of patient perception of Pain and Function, or ROM, MGWS (7.2 versus 6.9), PRWE (24 versus 23.6) and quick DASH scores (17.3 versus 19.1) between the two groups at 6 months. The younger group did have significantly better grip strength, but when compared as a percentage of the uninjured wrist, the results were also similar (83% vs 80%). Conclusions. VLPs are a suitable option for fixing distal radial fractures in older patients (>60yrs) and the clinical results appear to be just as good as they are in younger patients


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 1 - 1
1 Apr 2013
Russell TA
Full Access

Hip fracture treatment strategies continue to evolve with the goal of restoring hip fracture victims to Pre-injury Functional levels. Strategies for improved treatment have focused on fracture exposure, reduction, provisional fixation and definitive fixation with implant designs optimised for fracture union with minimal implant failure as originally proposed by Lambotte. Multiple implant designs have been conceived based on perceived inadequacies of previous generational designs. To better understand this evolutionary process, it is necessary to review the predecessors of modern fracture treatment and understand their design concepts and results. It is interesting that the modern era of surgical treatment of hip fractures actually began in 1902, when Dr Royal Whitman advocated the necessity of a closed reduction of adult hip fractures under general anesthesia and stabilisation by hip spica cast. Dr Whitman predicted the evolution of stabilisation by internal fixation and commented on this in his 1932 JBJS editorial emphasising the importance of surgical treatment of fractures. Dr Smith-Peterson, also from New York, in 1925 developed the 1st commercially successful hip implant, a tri–flanged nail. These first surgeries were performed with an open reduction, through a Smith-Petersen approach without radiographic control. This nail device was rapidly modified in the 1930's to permit insertion over a guide wire with a radiographic controlled insertion technique, a minimally invasive procedure. Nail penetration and implant failure in pertrochanteric fractures led to the rapid development of side-plates and a refocus on reduction stability. This led to a period of primary corrective osteotomies for enhanced stability, but fell out of failure after the sliding hip screw concept took hold. Originally conceived by Godoy-Moreira and Pohl independently in the 1940s, it became rapidly accepted as a method to avoid nail penetration and implant failure, unfortunately at the expense of accepting malunion and collapse of the fracture. Even the importance of rotational stability was discarded as insignificant by Holt in 1963. The concept of reduction of the Antero-Medial cortex was forgotten in favour of the Tip-apex distance as the only important variable in reduction to avoid implant cut-out. The concept of malunion of pertrochanteric fractures was simply deleted from consideration with disregard for the possible association of impaired functional recovery. Several recent papers that improved functional recovery is possible when these new implants are coupled with successful reduction strategies. Further studies are needed to identify the correct choice of implant for the appropriate fracture configuration, which may lead to a revision of our current fracture classification systems and our concepts of stability


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 168 - 168
1 Sep 2012
Von Rueden C Trapp O Hierholzer C Prohaska S Bräun K Wurm S Buehren V
Full Access

Background. For the treatment of proximal humeral fractures two major therapeutic principles can be employed: Intramedullary nailing (PHN) or locking plate osteosynthesis. Aim of this study was to evaluate and compare clinical and radiological long-term outcome of proximal humeral fracture stabilization using PHN or angular stable plating. In addition, we discussed advantages and disadvantages of both techniques and aimed at establishing criteria which operative technique should preferentially be utilized for selected fracture configurations. Materials and Methods. In a prospective study between 2003 and 2010 we analyzed 72 patients with proximal humeral fracture who had been treated by PHN (44 patients) or angular stable plating (28 patients) in a European Level 1 Trauma Center. In the two cohort groups the following epidemiologic data was found. 46 patients were women, and 26 men with a mean age of 60.6 years (range 18–91). Follow-up was performed 38–82 months after accident, on average. Mechanism of injury was fall in 59, motor cycle accident in 4, bike accident in 8 patients, and fall from horse in 1 patient. Duration time between accident and operation was 2.8 days on average. Osteoporosis was previously known in 20 out of all evaluated patients (plate: 7/28; nail: 13/44). Fractures were classified using the Neer classification and Binary description system: There were 35 3-part fractures (PHN: 26; plate: 9) and 37 4-part fractures (PHN: 18; plate: 19), respectively. Functional and radiological outcome was assessed in a range of 38–82 months after trauma using Constant Score. Results. No clinical symptoms after 3 years were observed in 40 patients, whereas in 32 patients clinical symptoms were evaluated related to pain and/or loss of function. Secondary revision after plate fixation had to be performed in 5 out of 28 patients and in 11 out of 44 patients in the PHN group. Functional outcome using the Constant score demonstrated a total score of 72.9 (ipsi-lateral side) vs. 88.4 (contra-lateral side) in all evaluated patients, on average. Complete metal removal was performed in 34 out of 72 patients (PHN: 17; plate: 17). Conclusion. Both i.m. nailing and angular stable plating are adequate treatment options for proximal humeral fractures. No significant differences in outcome between implants regarding fracture healing, nonunion, and infection were found. Locked plating can be utilized for all distal humerus fracture including complex 4-part fractures. I.m. nailing provides favorable intramedullary stability and can be successfully implanted in multi-segmental fractures of the upper extremity. However, both systems require precise preoperative planning and advanced surgical experience. Clinical long-term outcome largely depends on surgical technique and not so much on the choice of implant


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1082 - 1087
1 Aug 2020
Yiğit Ş Arslan H Akar MS Şahin MA

Aims

Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP.

Methods

This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 973 - 983
1 Jul 2018
Schmal H Froberg L S. Larsen M Südkamp NP Pohlemann T Aghayev E Goodwin Burri K

Aims

The best method of treating unstable pelvic fractures that involve the obturator ring is still a matter for debate. This study compared three methods of treatment: nonoperative, isolated posterior fixation and combined anteroposterior stabilization.

Patients and Methods

The study used data from the German Pelvic Trauma Registry and compared patients undergoing conservative management (n = 2394), surgical treatment (n = 1345) and transpubic surgery, including posterior stabilization (n = 730) with isolated posterior osteosynthesis (n = 405) in non-complex Type B and C fractures that only involved the obturator ring anteriorly. Calculated odds ratios were adjusted for potential confounders. Outcome criteria were intraoperative and general short-term complications, the incidence of nerve injuries, and mortality.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims

The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications.

Patients and Methods

We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 237 - 244
1 Feb 2011
Berber O Amis AA Day AC

The purpose of this study was to assess the stability of a developmental pelvic reconstruction system which extends the concept of triangular osteosynthesis with fixation anterior to the lumbosacral pivot point. An unstable Tile type-C fracture, associated with a sacral transforaminal fracture, was created in synthetic pelves. The new concept was compared with three other constructs, including bilateral iliosacral screws, a tension band plate and a combined plate with screws. The pubic symphysis was plated in all cases. The pelvic ring was loaded to simulate single-stance posture in a cyclical manner until failure, defined as a displacement of 2 mm or 2°. The screws were the weakest construct, failing with a load of 50 N after 400 cycles, with maximal translation in the craniocaudal axis of 12 mm. A tension band plate resisted greater load but failure occurred at 100 N, with maximal rotational displacement around the mediolateral axis of 2.3°.

The combination of a plate and screws led to an improvement in stability at the 100 N load level, but rotational failure still occurred around the mediolateral axis. The pelvic reconstruction system was the most stable construct, with a maximal displacement of 2.1° of rotation around the mediolateral axis at a load of 500 N.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 658 - 664
1 May 2014
Teo BJX Koh JSB Goh SK Png MA Chua DTC Howe TS

Management of bisphosphonate-associated subtrochanteric fractures remains opinion- or consensus-based. There are limited data regarding the outcomes of this fracture.

We retrospectively reviewed 33 consecutive female patients with a mean age of 67.5 years (47 to 91) who were treated surgically between May 2004 and October 2009. The mean follow-up was 21.7 months (0 to 53). Medical records and radiographs were reviewed to determine the post-operative ambulatory status, time to clinical and radiological union and post-fixation complications such as implant failure and need for second surgery.

The predominant fixation method was with an extramedullary device in 23 patients. 25 (75%) patients were placed on wheelchair mobilisation or no weight-bearing initially. The mean time to full weight-bearing was 7.1 months (2.2 to 29.7). The mean time for fracture site pain to cease was 6.2 months (1.2 to 17.1). The mean time to radiological union was 10.0 months (2.2 to 27.5). Implant failure was seen in seven patients (23%, 95 confidence interval (CI) 11.8 to 40.9). Revision surgery was required in ten patients (33%, 95 CI 19.2 to 51.2).

A large proportion of the patients required revision surgery and suffered implant failure. This fracture is associated with slow healing and prolonged post-operative immobility.

Cite this article: Bone Joint J 2014;96-B:658–64.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1697 - 1702
1 Dec 2013
Maroto MD Scolaro JA Henley MB Dunbar RP

Bicondylar tibial plateau fractures result from high-energy injuries. Fractures of the tibial plateau can involve the tibial tubercle, which represents a disruption to the extensor mechanism and logically must be stabilised. The purpose of this study was to identify the incidence of an independent tibial tubercle fracture in bicondylar tibial plateau fractures, and to report management strategies and potential complications. We retrospectively reviewed a prospectively collected orthopaedic trauma database for the period January 2003 to December 2008, and identified 392 bicondylar fractures of the tibial plateau, in which 85 tibial tubercle fractures (21.6%) were identified in 84 patients. There were 60 men and 24 women in our study group, with a mean age of 45.4 years (18 to 71). In 84 fractures open reduction and internal fixation was undertaken, either with screws alone (23 patients) or with a plate and screws (61 patients). The remaining patient was treated non-operatively. In all, 52 fractures were available for clinical and radiological assessment at a mean follow-up of 58.5 weeks (24 to 94). All fractures of the tibial tubercle united, but 24 of 54 fractures (46%) required a secondary procedure for their tibial plateau fracture. Four patients reported pain arising from prominent tubercle plates and screws, which in one patient required removal. Tibial tubercle fractures occurred in over one-fifth of the bicondylar tibial plateau fractures in our series. Fixation is necessary and can be reliably performed with screws alone or with a screw and plate, which restores the extensor mechanism and facilitates early knee flexion.

Cite this article: Bone Joint J 2013;95-B:1697–1702.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 679 - 686
1 May 2010
Das De S Setiobudi T Shen L Das De S

There have been recent reports linking alendronate and a specific pattern of subtrochanteric insufficiency fracture. We performed a retrospective review of all subtrochanteric fractures admitted to our institution between 2001 and 2007. There were 20 patients who met the inclusion criteria, 12 of whom were on long-term alendronate. Alendronate-associated fractures tend to be bilateral (Fisher’s exact test, p = 0.018), have unique radiological features (p < 0.0005), be associated radiologically with a pre-existing ellipsoid thickening of the lateral femoral cortex and are likely to be preceded by prodromal pain. Biomechanical investigations did not suggest overt metabolic bone disease. Only one patient on alendronate had osteoporosis prior to the start of therapy. We used these findings to develop a management protocol to optimise fracture healing. We also advocate careful surveillance in individuals at-risk, and present our experience with screening and prophylactic fixation in selected patients.