Objectives. The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. Methods. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed. Results. Seven studies including 528 patients were included. The overall meta-analysis found that there was no difference in clinical outcomes. However, subgroup and sensitivity analyses found improved patient outcomes for more complex fractures managed surgically. Four-part fractures that underwent surgery had improved long-term health utility scores (mean difference, MD 95% CI 0.04 to 0.28; p = 0.007). They were also less likely to result in osteoarthritis, osteonecrosis and non/malunion (OR 7.38, 95% CI 1.97 to 27.60; p = 0.003). Another significant subgroup finding was that secondary surgery was more common for patients that underwent internal fixation compared with conservative management within the studies with predominantly three-part fractures (OR 0.15, 95% CI 0.04 to 0.63; p = 0.009). Conclusion. This meta-analysis has demonstrated that differences in the type of fracture and surgical treatment result in outcomes that are distinct from those generated from analysis of all types of fracture and surgical treatments grouped together. This has important implications for clinical decision making and should highlight the need for future trials to adopt more specific inclusion criteria. Cite this article: S. Sabharwal, N. K. Patel, D. Griffiths, T. Athanasiou, C. M. Gupte, P. Reilly. Trials based on specific
Aims. In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries. Patients and Methods. Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks.
Supracondylar humeral fractures are common in
children, but there are no classification systems or radiological parameters
that predict the likelihood of having to perform an open reduction.
In a retrospective case–control study we evaluated the use of the
medial spike angle and fracture tip–skin distance to predict the
mode of reduction (closed or open) and the operating time in fractures
with posterolateral displacement. A total of 21 patients (4.35%) with
a small medial spike angle (<
45°) were identified from a total
of 494 patients, and 42 patients with a medial spike angle of >
45° were randomly selected as controls. The medial spike group had
significantly smaller fracture tip–skin distances (p <
0.001),
longer operating times (p = 0.004) and more complications (p = 0.033)
than the control group. There was no significant difference in the
mode of reduction and a composite outcome measure. After adjustments
for age and gender, only fracture tip–skin distance remained significantly
associated with the operating time (β = -0.724, p = 0.042) and composite
outcome (OR 0.863 (95% confidence interval 0.746 to 0.998); p = 0.048). Paediatric orthopaedic surgeons should have a lower threshold
for open reduction when treating patients with a small medial spike
angle and a small fracture tip–skin distance. Cite this article:
Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fragment plates. Sixteen paired human cadaveric clavicles were assigned pairwise to two groups for instrumentation with either a 2.7 mm Variable Angle Locking Compression Plate placed superiorly (Group 1), or with one 2.5 mm anterior plate combined with one 2.0 mm superior matrix mandible plate (Group 2). An unstable clavicle shaft fracture AO/OTA15.2C was simulated by means of a 5 mm osteotomy gap. All specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis and monitored via motion tracking. Initial stiffness was significantly higher in Group 2 (9.28±4.40 N/mm) compared to Group 1 (3.68±1.08 N/mm), p=0.003. The amplitudes of interfragmentary motions in terms of craniocaudal and shear displacement, fracture gap opening and torsion were significantly bigger over the course of 12500 cycles in Group 1 compared to Group 2; p≤0.038. Cycles to 2 mm shear displacement were significantly lower in Group 1 (22792±4346) compared to Group 2 (27437±1877), p=0.047. From a biomechanical perspective, low-profile 2.5/2.0 dual plates demonstrated significantly higher initial stiffness, less interfragmentary movements, and higher resistance to failure compared to 2.7 single superior variable-angle locking plates and can therefore be considered as a useful alternative for diaphyseal clavicle fracture fixation especially in unstable
Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering hip fracture fixation strategies. A retrospective cohort study using Scottish hip fracture audit (SHFA) data was performed for the period 2016–2022. Patients ≥50 with a hip fracture and treated with IMN or SHS constructs at Scottish Hospitals were included. Comparative analyses, including adjustment for confounders, were performed utilising Multivariable logistic regression for dichotomous outcomes and Mann-Whitney-U tests for non-parametric data. A sub-group analysis was also performed focusing on AO-A1/A2 configurations which utilised additional regional data. Cost differences in Length of Stay (LOS) were calculated using defined costs from the NHS Scotland Costs book. In all analyses p<0.05 denoted significance. 13638 records were included (72% female). 9867 received a SHS (72%). No significant differences were identified in 30 or 60-day survival (Odds Ratio [OR] 1.05, 95%CI 0.90–1.23; p=0.532), (OR 1.10, 95%CI 0.97–1.24; p=0.138) between SHS and IMN's. There was however a significantly lower early mobilisation rate with IMN vs SHS (OR 0.64, 95%CI 0.59–0.70; p<0.001), and lower likelihood of discharge to domicile by day-30 post-admission (OR 0.77, 95%CI 0.71–0.84; p<0.001). Acute and overall, LOS were significantly lower for SHS vs IMN (11 vs 12 days and 20 vs 24 days respectively; p<0.001). Findings were similar across a sub-group analysis of 559 AO A1/A2
Aims. During the COVID-19 pandemic, many patients continue to require urgent surgery for hip fractures. However, the impact of COVID-19 on perioperative outcomes in these high-risk patients remains unknown. The objectives of this study were to establish the effects of COVID-19 on perioperative morbidity and mortality, and determine any risk factors for increased mortality in patients with COVID-19 undergoing hip fracture surgery. Methods. This multicentre cohort study included 340 COVID-19-negative patients versus 82 COVID-19-positive patients undergoing surgical treatment for hip fractures across nine NHS hospitals in Greater London, UK. Patients in both treatment groups were comparable for age, sex, body mass index,
There are a number of periprosthetic femoral fracture (PFF) fixation failures. In several cases the effect of
Background: A radiological audit of the local use of the Dynamic Hip Screw in extracapsular proximal femur fractures. Study aim: to identify cases of mechanical failure and revision, to determine predictors of fixation failure. Methods: A retrospective radiological review of 567 consecutive cases at Western Australian tertiary hospitals over a 3 year period (2002 – 2004) using the Picture Archive Computer System (PACS). Results: Female: male ratio was 2.79: 1. Evan’s classification: 418 fractures stable (73.7%), 149 unstable (26.3%). Failure of fixation occurred in 14 cases (2.5%); ten due to hip screw cut out (1.8%) and four due to plate pull off (0.8%). All cases of cut out had a significantly higher mean tip apex distance (TAD) (31 vs 20mm, P <
0.001) and an unstable
Background. There remains a paucity of clinical studies on the effects of coronavirus on perioperative outcomes, with no existing trials reporting on risk factors associated with increased risk of postoperative mortality in these patients. The objectives of this study were to assess perioperative complications and identify risk factors for increased mortality in patients with coronavirus undergoing surgery. Methods. This multicentre cohort study included 340 coronavirus negative patients versus 82 coronavirus positive patients undergoing surgical treatment for neck of femur fractures across nine NHS hospitals within Greater London, United Kingdom. Predefined study outcomes relating to patient demographics,
Radiation exposure is a hazard to orthopaedic surgeons, theatre staff and patients intra-operatively. Obesity is becoming a more prevalent problem worldwide and there is little evidence how a patient's body habitus correlates with the radiation doses required to penetrate the soft tissues for adequate imaging. We aimed to identify if there was a correlation between Body Mass Index (BMI) and radiation exposure intra-operatively. We performed a retrospective review of 75 patients who underwent sliding hip screw fixation for femoral neck fractures in one year. We recorded Body Mass Index (BMI), screening time, dose area product (DAP), American Society of Anesthesiologists (ASA) grade, seniority of surgeon and complexity of the
The aim of this study was to establish any association between implant cut-out and a Tip Apex Distance (TAD), ≥25mm, in proximal femoral fractures, following closed reduction and stabilisation, with either a Dynamic Hip Screw (DHS) or Intramedullary Hip Screw (IMHS) device. Furthermore, we investigated whether any difference in cut-out rate was related to
Background. This is an epidemiological study of patients with middle third clavicle fractures presenting to a tertiary hospital. The data is used to formulate a classification system for middle third clavicle fractures based on
Osteotomy has been used in the treatment of unstable intertrochanteric hip fractures in an attempt to increase the stability of the fracture fragments. We have assessed this stability in a randomised prospective trial on 100 consecutive patients, all having fixation by an AO dynamic hip screw, comparing anatomical reduction with two types of osteotomy. The groups were similar in terms of age, gender, mental test score, and
In Displaced Intracapsular Hip Fractures (ICHF) in young active patients, preservation of the femoral head and its blood supply are of high importance and urgent surgical treatment with anatomic reduction and internal fixation is the preferred intervention. Due to the strong varus displacement shear forces exerted across the hip, there are relatively high complication rates after fixation. There is no consensus regarding the optimal fixation device or technique. This retrospective study compared closed reduction internal fixation method using cannulated cancellous screw (CCS) with the Targon Femoral Neck (TFN) hip fixed angle screw. Data regarding, gender, operational data, duration of surgery, complications, NAS (Numerical Analogue Scale) pain score, Modified Harris Hip Score (MHHS) and SF-12 scores were retrieved for patients younger than 65 with displaced ICHF. Eighty-two patients were included in the study, 30 patients treated with CCS were compared to 52 patients treated with TFN.
Acetabular fractures are associated with long-term morbidity. Our prospective cohort study sought to understand the recovery trajectory of this injury over five years. Eligible patients at a level I trauma centre were recruited into a longitudinal registry of surgical acetabular fractures between June 2004 and August 2019. Patient-reported outcome measures (PROMs), including the 36-Item Short Form Health Survey (SF-36) physical component summary (PCS), were recorded at baseline pre-injury recall and six months, one year, two years, and five years postoperatively. Comparative analyses were performed for elementary and associated fracture patterns. The proportion of patients achieving minimal clinically important difference (MCID) was determined. The rate of, and time to, conversion to total hip arthroplasty (THA) was also established.Aims
Methods
The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs). All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.Aims
Methods
Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered. Cite this article:
Introduction. Hoffa fractures are rare, intra-articular fractures of the femoral condyle in the coronal plane and involving the weight-bearing surface of the distal femur. Surgical fixation is warranted to achieve stability, early mobilisation and satisfactory knee function. We describe a unique type of Hoffa fracture in the coronal plane with sagittal split and intra-articular comminution. There is scant evidence in current literature with regards to surgical approaches, techniques and implants. We report of our case with a review of the literature. Case report. A 40 year old male motorcyclist was involved in a high speed road traffic collision. X-rays confirmed displaced unicondylar fracture of the lateral femoral condyle. CT showed sagittal split of the Hoffa fragment and intra-articular comminution. MRI showed partial rupture of the anterior cruciate ligament. The patient underwent definitive surgical treatment via a midline skin incision and lateral parapatellar approach using cannulated screws, headless compression screws and anti-glide plate. Weightbearing was commenced at 8 weeks. Arthroscopy and adhesiolysis was performed at 12 weeks to improve range of motion. The patient was discharged at one year with a pain-free, functional knee. Discussion. Hoffa fractures are high-energy fractures, often seen in young male motorcyclists with flexed and slightly abducted knee. Most papers recommend surgical fixation, however there is no widely accepted surgical method or rehabilitation regime. Varying surgical approaches, screw direction, choice of implants, and post-operative care have been described. Surgical approach depends on the configuration of the fracture. The medial/lateral parapatellar approach is commonly used as it does not compromise future arthroplasty, but it does not allow access to fix posterior comminution. Arthroscopic-assistance may be used with good outcomes and less tissue dissection. AP screws are widely reported in the literature, most likely due to easier access to the fracture site. PA screws may provide better stability, but access is more difficult. Fixation often involves passing screws through the articular surface, therefore the area damaged should be kept to a minimum by using the smallest possible screw; headless compression screws leave a smaller footprint in the articular cartilage. Locking plate augmentation generally gives good outcomes. Conclusion. Hoffa fractures are rare and difficult to treat. Surgical treatment is the best choice for optimum post-operative knee function. There is no consensus on choice of surgical approaches, techniques and implants, as these are dependent on
Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures. We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups.Aims
Methods
The October 2024 Shoulder & Elbow Roundup360 looks at: Proximal humeral fractures with vascular compromise; Outcomes and challenges of revision arthroscopic rotator cuff repair: a systematic review; Evaluating treatment effectiveness for lateral elbow tendinopathy: a systematic review and network meta-analysis; Tendon transfer techniques for irreparable subscapularis tears: a comparative review; Impact of subscapularis repair in reverse shoulder arthroplasty; Isolated subscapularis tears strongly linked to shoulder pseudoparesis; Nexel and Coonrad-Morrey total elbow arthroplasties show comparable revision rates in New Zealand study; 3D MRI matches 3D CT in assessing bone loss and shoulder morphology in dislocation cases.