Advertisement for orthosearch.org.uk
Results 1 - 20 of 21
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 60 - 60
11 Apr 2023
Chalak A Kale S Mehra S Gunjotikar A Singh S Sawant R
Full Access

Osteomyelitis is an inflammatory condition accompanied by the destruction of bone and caused by an infecting microorganism. Open contaminated fractures can lead to the development of osteomyelitis of the fractured bone in 3-25% of cases, depending on fracture type, degree of soft-tissue injury, degree of microbial contamination, and whether systemic and/or local antimicrobial therapies have been administered. Untreated, infection will ultimately lead to non-union, chronic osteomyelitis, or amputation. We report a case series of 10 patients that presented with post-operative infected non-union of the distal femur with or without prior surgery. The cases were performed at Padmashree Dr. D. Y. Patil Hospital, Nerul, Navi Mumbai, India. All the patients’ consents were taken for the study which was carried out in accordance with the Helsinki Declaration. The methodology involved patients undergoing a two-stage procedure in case of no prior implant or a three-stage procedure in case of a previous implant. Firstly, debridement and implant removal were done. The second was a definitive procedure in form of knee arthrodesis with ring fixator and finally followed by limb lengthening surgery. Arthrodesis was planned in view of infection, non-union, severe arthritic, subluxated knee, stiff knee, non-salvage knee joint, and financial constraints. After all the patients demonstrated wound healing in 3 months along with good radiographic osteogenesis at the knee arthrodesis site, limb lengthening surgeries by tibial osteotomy were done to overcome the limb length discrepancy. Distraction was started and followed up for 5 months. All 10 patients showed results with sound knee arthrodesis and good osteogenesis at the osteotomy site followed by achieving the limb length just 1-inch short from the normal side to achieve ground clearance while walking. Our case series is unique and distinctive as it shows that when patients with infected nonunion of distal femur come with the stiff and non-salvage knee with severe arthritic changes and financial constraints, we should consider knee arthrodesis with Ilizarov ring fixator followed by limb lengthening surgery


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 29 - 29
1 Dec 2022
Pedrini F Salmaso L Mori F Sassu P Innocenti M
Full Access

Open limb fractures are typically due to a high energy trauma. Several recent studied have showed treatment's superiority when a multidisciplinary approach is applied. World Health Organization reports that isolate limb traumas have an incidence rate of 11.5/100.000, causing high costs in terms of hospitalization and patient disability. A lack of experience in soft tissue management in orthopaedics and traumatology seems to be the determining factor in the clinical worsening of complex cases. The therapeutic possibilities offered by microsurgery currently permit simultaneous reconstruction of multiple tissues including vessels and nerves, reducing the rate of amputations, recovery time and preventing postoperative complications. Several scoring systems to assess complex limb traumas exist, among them: NISSSA, MESS, AO and Gustilo Anderson. In 2010, a further scoring system was introduced to focus open fractures of all locations: OTA-OFC. Rather than using a single composite score, the OTA-OFC comprises five components grades (skin, arterial, muscle, bone loss and contamination), each rated from mild to severe. The International Consensus Meeting of 2018 on musculoskeletal infections in orthopaedic surgery identified the OTA-OFC score as an efficient catalogue system with interobserver agreement that is comparable or superior to the Gustilo-Anderson classification. OTA-OFC predicts outcomes such as the need for adjuvant treatments or the likelihood of early amputation. An orthoplastic approach reconstruction must pay adequate attention to bone and soft tissue infections management. Concerning bone management: there is little to no difference in terms of infection rates for Gustilo-Anderson types I–II treated by reamed intramedullary nail, circular external fixator, or unreamed intramedullary nail. In Gustilo-Anderson IIIA-B fractures, circular external fixation appears to provide the lowest infection rates when compared to all other fixation methods. Different technique can be used for the reconstruction of bone and soft tissue defects based on each clinical scenario. Open fracture management with fasciocutaneous or muscle flaps shows comparable outcomes in terms of bone healing, soft tissue coverage, acute infection and chronic osteomyelitis prevention. The type of flap should be tailored based on the type of the defect, bone or soft tissue, location, extension and depth of the defect, size of the osseous gap, fracture type, and orthopaedic implantation. Local flaps should be considered in low energy trauma, when skin and soft tissue is not traumatized. In high energy fractures with bone exposure, muscle flaps may offer a more reliable reconstruction with fewer flap failures and lower reoperation rates. On exposed fractures several studies report precise timing for a proper reconstruction. Hence, timing of soft tissue coverage is a critical for length of in-hospital stay and most of the early postoperative complications and outcomes. Early coverage has been associated with higher union rates and lower complications and infection rates compared to those reconstructed after 5-7 days. Furthermore, early reconstruction improves flap survival and reduces surgical complexity, as microsurgical free flap procedures become more challenging with a delay due to an increased pro-thrombotic environment, tissue edema and the increasingly friable vessels. Only those patients presenting to facilities with an actual dedicated orthoplastic trauma service are likely to receive definitive treatment of a severe open fracture with tissue loss within the established parameters of good practice. We conclude that the surgeon's experience appears to be the decisive element in the orthoplastic approach, although reconstructive algorithms may assist in decisional and planification of surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 106 - 106
1 Mar 2021
Torgutalp SS Babayeva N Kara OS Özkan Ö Güdemez G Korkusuz F
Full Access

Osteoporosis is a common disorder characterized by low bone mass and reduced bone quality that affects the bone strength negatively and leads to increased risk of fracture. Bone mineral density (BMD) has been the standard instrument for the diagnosis of osteoporosis and the determination of fracture risk. Despite the approximation of the bone mass, BMD does not provide information about the bone structure. Trabecular bone score (TBS), which provides an indirect evaluation of skeletal microarchitecture, is calculated from dual X-ray absorptiometry and a simple and noninvasive method that may contribute to the prediction of osteoporotic fractures in addition to the measure of bone density. The goal of this study was to determine the mean TBS values in healthy postmenopausal women and the overall association between TBS and demographic features, bone mineral density of the lumbar spine and femoral neck and bone mineral density to body mass index ratio (BMD/BMI) of the lumbar spine. Fifty-three postmenopausal healthy women participated. The bone mineral density of the lumbar spine and femoral neck were measured dual X-ray absorptiometry. Anteroposterior lumbar spine acquisitions were used to calculate TBS for L1-L4. Age, height, weight, BMI and the ratio of BMD to BMI, which was considered to be a simple tool for assessing fracture risk in especially obese individuals, were calculated. The relationship between TBS and other variables was examined using Spearman's rank correlation coefficients. Mean BMD of the lumbar spine and the femoral neck were 0.945 ± 0.133 and 0.785 ± 0.112 g/cm2, respectively (Table 1). Mean TBS was 1.354 ± 0.107. There was a significant positive moderate correlation between TBS and total lumbar BMD/BMI ratio (r=0.595, pTBS values of postmenopausal women were negatively correlated with age and BMI and positively with bone mineral density and BMD/BMI ratio. The ratio between lumbar BMD and BMI presented a stronger correlation with TBS than that of BMD with TBS. Because of the better correlation, the BMD/BMI ratio may be used as a simple tool for the assessment of the risk of fractures. Further investigation may be needed to evaluate the factors influencing exercise intervention on TBS on this population of patients


Bone & Joint Research
Vol. 6, Issue 10 | Pages 602 - 609
1 Oct 2017
Jin A Cobb J Hansen U Bhattacharya R Reinhard C Vo N Atwood R Li J Karunaratne A Wiles C Abel R

Objectives. Bisphosphonates (BP) are the first-line treatment for preventing fragility fractures. However, concern regarding their efficacy is growing because bisphosphonate is associated with over-suppression of remodelling and accumulation of microcracks. While dual-energy X-ray absorptiometry (DXA) scanning may show a gain in bone density, the impact of this class of drug on mechanical properties remains unclear. We therefore sought to quantify the mechanical strength of bone treated with BP (oral alendronate), and correlate data with the microarchitecture and density of microcracks in comparison with untreated controls. Methods. Trabecular bone from hip fracture patients treated with BP (n = 10) was compared with naïve fractured (n = 14) and non-fractured controls (n = 6). Trabecular cores were synchrotron scanned and micro-CT scanned for microstructural analysis, including quantification of bone volume fraction, microarchitecture and microcracks. The specimens were then mechanically tested in compression. Results. BP bone was 28% lower in strength than untreated hip fracture bone, and 48% lower in strength than non-fractured control bone (4.6 MPa vs 6.4 MPa vs 8.9 MPa). BP-treated bone had 24% more microcracks than naïve fractured bone and 51% more than non-fractured control (8.12/cm. 2. vs 6.55/cm. 2. vs 5.25/cm. 2. ). BP and naïve fracture bone exhibited similar trabecular microarchitecture, with significantly lower bone volume fraction and connectivity than non-fractured controls. Conclusion. BP therapy had no detectable mechanical benefit in the specimens examined. Instead, its use was associated with substantially reduced bone strength. This low strength may be due to the greater accumulation of microcracks and a lack of any discernible improvement in bone volume or microarchitecture. This preliminary study suggests that the clinical impact of BP-induced microcrack accumulation may be significant. Cite this article: A. Jin, J. Cobb, U. Hansen, R. Bhattacharya, C. Reinhard, N. Vo, R. Atwood, J. Li, A. Karunaratne, C. Wiles, R. Abel. The effect of long-term bisphosphonate therapy on trabecular bone strength and microcrack density. Bone Joint Res 2017;6:602–609. DOI: 10.1302/2046-3758.610.BJR-2016-0321.R1


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 121 - 121
1 Dec 2020
Haffner-Luntzer M Fischer V Ignatius A
Full Access

Mice are increasingly used for fracture healing research because of the possibility to use transgenic animals to conduct research on the molecular level. Mice from both sexes can be used, however, there is no consensus in the literature if fracture healing differs between female and male mice. Therefore, the aim of the present study was to analyze the similarities and differences in endochondral fracture healing between female and male C57BL/6J mice, since this mouse strain is mainly used in bone research. For that purpose, 12-weeks-old female and male mice received a standardized femur midshaft osteotomy stabilized by an external fixator. Mice were euthanized 10 and 21 days after fracture and bone regeneration was analyzed by biomechanical testing, µCT analysis, histology, immunohistochemistry and gene expression analysis. At day 21, male mice displayed a significantly larger fracture callus than female mice accompanied by higher number of osteoclasts, higher tissue mineral density and absolute values of bone volume, whereas relative bone volume to tissue volume ratio did not differ between the groups. Biomechanical testing revealed significantly increased bending stiffness in both fractured and intact femurs from male vs. female mice, whereas relative bending stiffness of fractured femurs related to the intact femurs did not differ. 10 days after fracture, male mice display significantly more cartilage and less fibrous tissue area in the fracture callus than female mice, whereas bone area did not differ. On the molecular level, male mice displayed increased active β-catenin expression in the fracture callus, whereas estrogen receptor α (ERα) expression was reduced. In conclusion, male mice showed more prominent cartilaginous callus formation, increased mineralization and whole callus tissue formation, whereas functional outcome after fracture did not differ from female mice. This might be due either to the heavier weight of male mice or because of differences in molecular signaling pathways


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 83 - 83
1 Nov 2018
Procter P Insley G Engqvist H Pujari-Palmer M Billstrom GH Larsson S
Full Access

There are clinical situations in fracture repair, e.g. osteochondral fragments, where current implant hardware is insufficient. The proposition of an adhesive enabling fixation and healing has been considered but no successful candidate has emerged thus far. The many preclinical and few clinical attempts include fibrin glue, mussel adhesive and even “Kryptonite” (US bone void filler). The most promising recent attempts are based on phosphorylating amino acids, part of a common cellular adhesion mechanism linking mussels, caddis fly larvae, and mammals. Rapid high bond strength development in the wetted fatty environment of fractured bone, that is sustained during biological healing, is challenging to prove both safety and efficacy. Additionally, there are no “predicate” preclinical animal and human models which led the authors to develop novel evaluations for an adhesive candidate “OsStic. tm. ” based on calcium salts and amino acids. Adhesive formulations were evaluated in both soft (6/12 weeks) and hard tissue (3,7,10,14 & 42 days) safety studies in murine models. The feasibility of a novel adhesiveness test, initially proven in murine cadaver femoral bone, is being assessed in-vivo (3,7,10,14 & 42 days) in bilateral implantations with a standard tissue glue as the control. In parallel an ex-vivo human bone model using freshly harvested human donor bone is under development to underwrite the eventual clinical application of such an adhesive. This is part of a risk mitigation project bridging between laboratory biomaterial characterisation and a commercial biomaterial development where safety and effectiveness have to meet today´s new medical device requirements


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 104 - 104
1 Jan 2017
Manjubala I Basu P Narendrakumar U
Full Access

Bone grafting utilises tissue harvesting from second anatomic location of same patient (autograft) or from a human donor (allograft) to treat bone defects. Limited availability of bone grafts, donor site morbidity and risk of disease transmission led to an alternative strategy for bone grafting as synthetic materials that can promote bone regeneration. Engineered bone grafts are biocompatible and possess sufficient mechanical strength to support fractured bone. Polymer scaffolds lack mechanical stability whereas ceramic scaffolds are stiffer resulting in loosening of implants. Combining polymer and ceramic to form scaffolds can enhance the physical and mechanical properties and can be used for bone tissue engineering. We hypothesised that the nucleation of hydroxyapatite in carboxymethyl cellulose (CMC) matrix would improve scaffold properties physically and mechanically; thus, demonstrating CMC based biomimetic process to synthesise novel CMC/ HA scaffolds with suitable physical, mechanical and biological properties for bone tissue engineering. CMC/ HA scaffolds were synthesized by in situmethod at room temperature (RT) and 60°C and are labelled as CHRT and CH60 respectively, keeping the molar ratio of Ca/P as constant ∼1.6. The nucleation of hydroxyapatite (HA) from calcium chloride (CaCl. 2. ) and sodium dihydrogen phosphate (NaH. 2. PO. 4. ) was initiated inside carboxymethyl cellulose (CMC). CaCl. 2. solution was introduced gently in aqueous solution of CMC, thereafter; NaH. 2. PO. 4. solution was added dropwise and the mixture was stirred vigorously, kept overnight for aging at RT to obtain milky white slurry. The slurry was washed with distilled water to neutralize, cast into moulds and dried in hot air oven for 72 h to obtain scaffolds. Scanning electron microscopy (SEM) was performed to determine the surface topography of the scaffolds. Mechanical properties were tested with Universal Testing Machine (UTM) and cytotoxicity was performed by MTT assay using fibroblast cells (NIH 3T3). SEM images shows that HA aggregates like beads and knitted orderly over CMC backbone. There is an increase in HA agglomerates and decrease in bead size with increase in synthesis temperature from RT to 60°C. Scaffolds synthesized at 60°C show enhanced mechanical properties. Compressive strength of CHRT and CH60 are 0.68 MPa and 0.9 MPa respectively and compressive moduli of CHRT and CH60 are 33 MPa and 69 MPa respectively. MTT assay confirmed proliferation of fibroblast cells, hence; proved the non-toxic nature of the scaffolds. MTT assay reveals the cell viability (cell exoskeleton) on the scaffolds after 24 h incubation. In this study, CMC/ HA scaffolds were synthesised by in situmethod at RT and 60°C. Enhanced mechanical properties and cytocompatibility reveal the potentiality of the scaffolds for bone tissue engineering purposes


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 84 - 84
1 Aug 2012
MacLeod A Pankaj P Simpson H
Full Access

Finite element modelling is being extensively used to evaluate the biomechanical behaviour of fractured bone treated with fixation devices. Appropriate modelling of the bone-implant interface is key to quality biomechanical prediction. The present study considers this interface modelling in the context of locking plates. A majority of previous studies assume the interface to be represented by a tied constraint or a fully bonded interface. Many other studies incorporate a frictional interface but ignore screw threads. This study compares the various interface modelling strategies. An interface with screw threads explicitly included is also considered. The study finds that interface modelling has significant impact on both the global and local behaviour. Globally, the load-deflection behaviour shows considerable difference depending on the interface model. Locally, the stress-strain environment within the bone close to the screws is significantly altered. The results show that the widely used tie constraint can overestimate stiffness of a construct which must be correctly predicted to avoid non-union or periprosthetic re-fracture, especially in osteoporotic bone. In addition, the predictions of screw loosening, bone damage and stress shielding are very different when screw threads are included in the model


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 31 - 31
1 Oct 2016
Boughton O Zhao S Arnold M Ma S Cobb J Giuliani F Hansen U Abel R
Full Access

The increase in revision joint replacement surgery and fractures of bone around orthopaedic implants may be partly addressed by keeping bone healthy around orthopaedic implants by inserting implants with mechanical properties closer to the patient's bone properties. We do not currently have an accurate way of calculating a patient's bone mechanical properties. We are therefore investigating whether microindentation can accurately calculate bone stiffness. We received ethical approval to retrieve femoral heads and necks from patients undergoing hip replacement surgery for research. Cortical bone from the medial calcar region of the femoral neck was cut into 3×3×6mm cuboid specimens. Micro-indentation testing was performed in the direction of loading of the bone using a MicroMaterials indenter. The samples were kept hydrated and were not fixed or polished. From the unloading curve after indentation, the elastic modulus was calculated, using the Oliver- Pharr method. To assess which microindentation machine settings most precisely calculate the elastic modulus we varied the loading and unloading rates, load and indenter tip shape. The most precise results were obtained by using a spherical indenter tip (rather than Berkovich tip), high load (10N), a loading rate of 100 mN/s and unloading rate of 300 mN/s with a pause of 60 seconds at maximum load and multiple load cycles with constant loads. Using these settings the mean elastic modulus over 12 cycles of testing was 13.0 GPa (+/- 2.47). By using a spherical indenter tip and fast unloading it was possible to get precise apparent modulus values. By unloading as fast as possible the effects of bone viscoelastic properties are minimised. By using a spherical indenter tip, plastic deformation at the tip is minimised (compared to the Berkovich tip). We are performing further standard compression tests on the samples to verify the accuracy of the indentation tests


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1606 - 1613
1 Nov 2010
Oshima S Ishikawa M Mochizuki Y Kobayashi T Yasunaga Y Ochi M

We used interconnected porous calcium hydroxyapatite ceramic to bridge a rabbit ulnar defect. Two weeks after inducing the defect we percutaneously injected rabbit bone marrow-derived mesenchymal stromal cells labelled with ferumoxide. The contribution of an external magnetic targeting system to attract these cells into the ceramic and their effect on subsequent bone formation were evaluated. This technique significantly facilitated the infiltration of ferumoxide-labelled cells into ceramic and significantly contributed to the enhancement of bone formation even in the chronic phase. As such, it is potentially of clinical use to treat fractures, bone defects, delayed union and nonunion


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 74 - 74
1 May 2017
ten Broeke R Rudolfina R Geurts J Arts J
Full Access

Background. Implant stability and is an important factor for adequate bone remodelling and both are crucial in the long-term clinical survival of total hip arthroplasty (THA). Assessment of early bone remodelling on X-rays during the first 2 years post-operatively is mandatory when stepwise introduction of a new implant is performed. Regardless of fixation type (cemented or cementless), early acetabular component migration is usually the weakest link in THA, eventually leading to loosening. Over the past years, a shift towards uncemented cup designs has occurred. Besides the established hydroxyapatite (HA) coated uncemented cups which provide ongrowth of bone, new uncemented implant designs stimulating ingrowth of bone have increased in popularity. These cups initiate ingrowth of bone into the implant by their open metallic structure with peripheral pores, to obtain a mechanical interlock with the surrounding bone, thereby stabilising the prosthesis in an early stage after implantation. This retrospective study assessed bone remodelling, osseointegration and occurrence of radiolucency around a new ingrowth philosophy acetabular implant. Methods. In a retrospectively, single centre cohort study all patients whom underwent primary THA with a Tritanium acetabular component in 2011 were included. Bone remodelling, osseointegration and occurrence of radiolucency were determined by two reviewers from X-ray images that were made at 6 weeks, 3–6-12 and 24 months post-operatively. Bone contact % was calculated based on the original Charnley and DeLee zones. According to Charnley and DeLee the outer surface of an acetabular cup is divided into 3 zones (1-2-3). For our analysis the original 3 zones were further divided into 2 producing 6 zones 1A to 3B. Each of these 6 zones were then further divided into 4 equal sections. We attributed 25 points per section in which complete bone contact without lucency was observed. If lucency was observed no points were attributed to the section. A fully osteointegrated cup in all 24 sections could therefore attain 600 points. The total of each section and zone was subsequently tallied and recalculated to produce the percentage of bone contact on a 1–100% score. Results. In 2011 131 patients; 54 male and 76 female with average age of 60.83 (SD 12.42) and 60.57 (SD 12.11) year respectively underwent primary THA at our institution and all where included in our study cohort. Majority of this cohort underwent primary THA due to osteoarthrosis and most patients were classified ASO I (18%) or ASA II (65%). At two year clinical follow-up two revision were performed. One constituted a femur and acetabulum revision due to leg length difference and a snapping hip phenomenon. Complications included 3 dislocations (all treated policlinic), 4 deep infections (all treated with Genta PMMA beads with prosthesis in situ and healed) and 1 removal of hematoma. In another patient the femoral component was revised due to a peri-prosthetic fracture. Mean bone contact % values for all Charnley and DeLee zones combined were calculated and improved from 68,18% (SD 22,36) at 6 weeks to 73,61% SD (16,26) at 3 months to 84,21% (SD 19,02) at 6 months to 86,90% (SD 16,0) at 1 year to 92,19% (SD 12,74) at two year follow-up. When analysing the bone contact % per individual zone a remarkable difference was found for zones 2A-B. In contrast to zone 1A-B and 3A-B the initial bone contact % was clearly although not significantly lower until two year follow-up. Conclusions. In this study, the bone apposition around Tritanium actebular component was retrospectively assessed until two year clinical. Our results show excellent bone apposition that continues to improve over time (at least until two year clinical follow-up) suggesting that the open trabecular Ti structure of the Tritanium has a positive effect on cup osseointegration. However, some recent reports have shown the development of reactive lines around cups with porous/trabecular metal surfaces, of which the meaning is still unclear. Our analysis indicated that especially acetabular zone 2A-B according to Charnley&DeLee needs time to establish a direct contact of the implant surface and the surrounding bone tissues. Perhaps this might be explained by reaming technique (underreaming vs line to line reaming) resulting in suboptimal seating of the cup. Therefore, careful follow-up of this new implant technology will remain necessary and continued in this study. We aim to improve cohort size and establish results at longer follow-up times. Furthermore we aim to correlate these results to RSA component migration analysis


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 232 - 232
1 Jul 2014
Ouellette E Elliott W Latta L Milne E Kaimrajh D Lowe J Makowski A Herndon E Kam C Sawardeker P
Full Access

Summary. For injuries to the lower leg or forearm, supplemental support from soft tissue compression (STC) with a splint or brace-like system and combined with external fixation could be done effectively and quickly with a minimal of facilities in the field. Introduction. Soft tissue compression (STC) in functional braces has been shown to provide rigidity and stability for most closed fractures, selected open fractures and can supplement some other forms of fracture fixation. However, soft tissue injuries are compromised in war injuries. This study was designed to evaluate if STC can provide adequate rigidity and stability either with, or without other forms of fixation techniques of simple fractures or bone defects after standardised soft tissue defects. The load was applied either axially or in bending as the bending configuration is more like conditions when positioned on a stretcher in the field. Methods. A simple, oblique fracture was created in 23 cadaveric femurs, 23 tibiae and fibulae, 22 humeri and 22 radii and ulnae of intact limb segments. The weight of each intact limb segment was measured. Cyclic axial loads (12 – 120N) were applied for each progressive condition: intact limb, mid shaft osteotomy, a lateral 1/4 circumferential soft tissue defect, 1/3 circumferential defect and finally, 3 cm bone defect. Limbs were randomly assigned to be stabilised be either plate and screw (PS), intramedullary rod (IR) or external fixation (EF). Testing with and without STC in a brace was performed after each condition. In an additional 36 forearms, bending rigidity was measured using a modular fracture brace with external fixation. The bone and the soft tissue weighed separately and the ratio of soft tissue to bone was calculated. ANOVA multi-variant analysis corrected for multiple comparisons was used to compare the axial rigidity between the different conditions tested. Results. There was no significant difference in axial rigidity for humerus or femoral shaft fractures treated by any of the methods related to the degree of soft tissue damage. Femurs, tibias and humeri with a 3 cm bone defect were best stabilised with IR. Forearms with a 3 cm bone defect were best stabilised with PS. Progressive increase in soft tissue defects did create progressive loss in rigidity in forearms and legs, but the most dramatic loss occurred with the bone defect and ST defect. The rigidity of IR and EF in legs decreased over 50% with bone defect, and about 20% of that was restored with STC. The rigidity of IR and EF in forearms decreased almost 79%, and about 21% of that was restored with STC. The increase in resistance to bending in the forearm was most significantly improved by STC. Discussion/Conclusions. Invasive types of surgical intervention provide the best rigidity to fractures, regardless of the presence of or size of a soft tissue defect. In general, use of PS and IR and application of conventional types of braces to achieve STC is not practical in the field. EF, however, can be applied quickly and easily with a minimal of facilities in the field and can be applied in such a way that no foreign bodies end up in the contaminated wound. For injuries to the leg or forearm, supplemental support from STC with a splint or brace-like system could be effective


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 75 - 75
1 Jul 2014
Farinella G Viceconti M Schileo E Falcinelli C Yang L Eastell R
Full Access

Summary. A retrospective study on 98 patients shows that FE-based bone strength from CT data (using validated FE models) is a suitable candidate to discriminate fractured versus controls within a clinical cohort. Introduction. Subject-specific Finite element models (FEM) from CT data are a promising tool to non-invasively assess the bone strength and the risk of fracture of bones in vivo in individual patients. The current clinical indicators, based on the epidemiological models like the FRAX tool, give limitation estimation of the risk of femoral neck fracture and they do not account for the mechanical determinants of the fracture. Aim of the present study is to prove the better predictive accuracy of individualised computer models based a CT-FEM protocol, with the accuracy of a widely used standard of care, the FRAX risk indicator. Patients and Methods. This retrospective cohort is individually-matched case control study composed by 98 Caucasian women who were at least 5 years post menopause. The case group consisted of 49 patients who had sustained a hip fracture (36 intra-capsular and 13 extra-capsular fractures) within the previous 90 days due to low-energy trauma. The CT datasets were segmented (using the ITK-Snap software) in order to extract the periosteal bone surface. Unstructured meshes (10-node tetrahedral elements) were generated using ANSYS mesh morphing software. Each CT dataset was calibrated using the European Spine Phantom. The inhomogeneous material properties were mapped from CT datasets into the FEM with the BoneMat_V3 software. Bone strength was evaluated in quasi-axial loading conditions, for a set of 12 different configurations sampling the cone of recorded in vivo hip joint reactions, and was defined as the minimum load inducing on the femoral neck surface an elastic principal strain value greater than a limit value. Results. There were no statistically significant difference between the fracture and the control groups for age, height and weight (p<0.05). All indices of areal bone mineral density (aBMD) and the volumetric mineral density (vBMD) between fractured and controls showed on average a lower value for fractured respect of the controls, with similar mean difference (14% for aBMD and 13% for the vBMD). FEM-predicted strength differed between fractured and non-fractured on average for 20%. To evaluate its ability to identify patients at risk of hip fracture, FEM-based strength was compared to the FRAX predictor by computing for each predictor the Receiver Operating Characteristic (ROC) curve, and the Area Under the Curve (AUC). The individualised risk predictor based on FEM bone strength was found to perform significantly better (AUC=0.76) than FRAX (AUC=0.66). When the FEM-based strength indicator was combined with available clinical information in a logistic regression, the resulting predictor achieved in this retrospective study an excellent accuracy (AUC=0.82). Discussion. This study confirms that individualised, CT- FEM, when generated using to the state-of-the-art protocols, can provide a predictor of the risk of hip fracture more accurate than those based on clinical data alone. In the integrated workflow developed in the VPHOP Project (FP7-ICT-223865) CT-based risk prediction is requested only for those patients for whom the clinical decision is uncertain


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 35 - 35
1 Mar 2012
Chang JS Kim JW Bae JY Jung KH Ryu JS Baek S Oh HK
Full Access

Introduction. We have evaluated the circulation of the femoral head after multiple pinning for femoral neck fractures by bone SPECT. Methods. Forty-four patients (33 women, 11 men, who had a mean age of 67 years) were enrolled prospectively. Early and late bone SPECT images were obtained on 2 to 13 days and 3 months after surgery and follow-up periods were over 12 months (average, 29 months). Results. Seventeen cases showed normal uptake on early bone SPECT and healed successfully. Twenty-seven cases showed decreased uptake on early bone SPECT. Among these 27 cases, reperfusion was confirmed in 18 cases (66.7%) by late bone SPECT. The remaining 9 cases showed no recovery and the femoral heads were collapsed eventually. According to the Garden classification, osteonecrosis was found in 4 of 28 cases (14.3%) in Type I, 2 of, 15 cases (13.3%) in Type II, 3 of 6 cases (50%) in Type III and osteonecrosis was not detected in the one Type IV case. Conclusion. In summary, bone SPECT is very sensitive and vascular insufficiency could be found even in the early post-operative period. Cases with normal uptake showed successful union. But, bone SPECT in early post-operative periods cannot be used to predict final outcome, as 66.7% of cases were recovered from ischemia. Although osteonecrosis was higher in cases with displacement, we should be careful for impacted fractures (Type I) as the incidence of osteonecrosis was not low


Bone & Joint Research
Vol. 5, Issue 10 | Pages 500 - 511
1 Oct 2016
Raina DB Gupta A Petersen MM Hettwer W McNally M Tägil M Zheng M Kumar A Lidgren L

Objectives

We have observed clinical cases where bone is formed in the overlaying muscle covering surgically created bone defects treated with a hydroxyapatite/calcium sulphate biomaterial. Our objective was to investigate the osteoinductive potential of the biomaterial and to determine if growth factors secreted from local bone cells induce osteoblastic differentiation of muscle cells.

Materials and Methods

We seeded mouse skeletal muscle cells C2C12 on the hydroxyapatite/calcium sulphate biomaterial and the phenotype of the cells was analysed. To mimic surgical conditions with leakage of extra cellular matrix (ECM) proteins and growth factors, we cultured rat bone cells ROS 17/2.8 in a bioreactor and harvested the secreted proteins. The secretome was added to rat muscle cells L6. The phenotype of the muscle cells after treatment with the media was assessed using immunostaining and light microscopy.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1534 - 1538
1 Nov 2007
Hammer TO Wieling R Green JM Südkamp NP Schneider E Müller CA

This study investigated the quality and quantity of healing of a bone defect following intramedullary reaming undertaken by two fundamentally different systems; conventional, using non-irrigated, multiple passes; or suction/irrigation, using one pass. The result of a measured re-implantation of the product of reaming was examined in one additional group. We used 24 Swiss mountain sheep with a mean tibial medullary canal diameter between 8 mm and 9 mm. An 8 mm ‘napkin ring’ defect was created at the mid-diaphysis. The wound was either surgically closed or occluded. The medullary cavity was then reamed to 11 mm. The Reamer/Irrigator/Aspirator (RIA) System was used for the reaming procedure in groups A (RIA and autofilling) and B (RIA, collected reamings filled up), whereas reaming in group C (Synream and autofilling) was performed with the Synream System. The defect was allowed to auto-fill with reamings in groups A and C, but in group B, the defect was surgically filled with collected reamings. The tibia was then stabilised with a solid locking Unreamed Humerus Nail (UHN), 9.5 mm in diameter. The animals were killed after six weeks. After the implants were removed, measurements were taken to assess the stiffness, strength and callus formation at the site of the defect.

There was no significant difference between healing after conventional reaming or suction/irrigation reaming. A significant improvement in the quality of the callus was demonstrated by surgically placing captured reamings into the defect using a graft harvesting system attached to the aspirator device. This was confirmed by biomechanical testing of stiffness and strength. This study suggests it could be beneficial to fill cortical defects with reaming particles in clinical practice, if feasible.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1402 - 1406
1 Oct 2007
Tayton K

Although much has been published on the causes of slipped upper femoral epiphysis and the results of treatment, little attention has been given to the mechanism of the slip. This study presents the results of the analysis of 13 adolescent femora, and the attempts to reproduce the radiological appearances of a typical slip. The mean age of the skeletons was 13 years (11 to 15). It was found that the internal bony architecture in the zone of the growth plate was such that a slip of the epiphysis on the metaphysis (in the normal meaning of the word slip) could not take place, largely relating to the presence of a tubercle of bone projecting down from the epiphysis. The only way that the appearance of a typical slipped upper femoral epiphysis could be reproduced was by rotating the epiphysis posteromedially on the metaphysis. The presence and size of this peg-like tubercle was shown radiologically by CT scanning in one pair of intact adolescent femurs.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1434 - 1438
1 Oct 2005
Eckardt H Ding M Lind M Hansen ES Christensen KS Hvid I

The re-establishment of vascularity is an early event in fracture healing; upregulation of angiogenesis may therefore promote the formation of bone. We have investigated the capacity of vascular endothelial growth factor (VEGF) to stimulate the formation of bone in an experimental atrophic nonunion model.

Three groups of eight rabbits underwent a standard nonunion operation. This was followed by interfragmentary deposition of 100 μg VEGF, carrier alone or autograft.

After seven weeks, torsional failure tests and callus size confirmed that VEGF-treated osteotomies had united whereas the carrier-treated osteotomies failed to unite. The biomechanical properties of the groups treated with VEGF and autograft were identical. There was no difference in bone blood flow.

We considered that VEGF stimulated the formation of competent bone in an environment deprived of its normal vascularisation and osteoprogenitor cell supply. It could be used to enhance the healing of fractures predisposed to nonunion.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 133 - 138
1 Jan 2007
Oe K Miwa M Sakai Y Lee SY Kuroda R Kurosaka M

We isolated multilineage mesenchymal progenitor cells from haematomas collected from fracture sites. After the haematoma was manually removed from the fracture site it was cut into strips and cultured. Homogenous fibroblastic adherent cells were obtained. Flow cytometry revealed that the adherent cells were consistently positive for mesenchymal stem-cell-related markers CD29, CD44, CD105 and CD166, and were negative for the haemopoietic markers CD14, CD34, CD45 and CD133 similar to bone-marrow-derived mesenchymal stem cells. In the presence of lineage-specific induction factors the adherent cells could differentiate in vitro into osteogenic, chondrogenic and adipogenic cells.

Our results indicate that haematomas found at a fracture site contain multilineage mesenchymal progenitor cells and play an important role in bone healing. Our findings imply that to enhance healing the haematoma should not be removed from the fracture site during osteosynthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 265 - 272
1 Feb 2007
Ristiniemi J Flinkkilä T Hyvönen P Lakovaara M Pakarinen H Jalovaara P

External fixation of distal tibial fractures is often associated with delayed union. We have investigated whether union can be enhanced by using recombinant bone morphogenetic protein-7 (rhBMP-7).

Osteoinduction with rhBMP-7 and bovine collagen was used in 20 patients with distal tibial fractures which had been treated by external fixation (BMP group). Healing of the fracture was compared with that of 20 matched patients in whom treatment was similar except that rhBMP-7 was not used.

Significantly more fractures had healed by 16 (p = 0.039) and 20 weeks (p = 0.022) in the BMP group compared with the matched group. The mean time to union (p = 0.002), the duration of absence from work (p = 0.018) and the time for which external fixation was required (p = 0.037) were significantly shorter in the BMP group than in the matched group. Secondary intervention due to delayed healing was required in two patients in the BMP group and seven in the matched group.

RhBMP-7 can enhance the union of distal tibial fractures treated by external fixation.