The strain on clinic and surgeon resources resulting
from a rise in demand for total knee replacement (TKR) requires reconsideration
of when and how often patients need to be seen for
Aims. The aims were to assess whether joint-specific outcome after total knee arthroplasty (TKA) was influenced by implant design over a 12-year
Abstract. Introduction. The optimal alignment technique for total knee replacement (TKR) remains controversial. We previously reported six-month and two-year results of a randomized controlled trial comparing kinematically (KA) versus mechanically (MA) aligned TKR. In the present study, we report 12-year results from this trial. Methods. The original cohort included 88 TKRs (44 KA using Shape Match patient-specific guides and 44 MA using conventional instrumentation), performed from 2008 to 2009. After IRB approval, the health record of the original 88 patients were queried. Revisions, re-operations, and complications were recorded. The non-deceased patients were contacted via phone. Reoperation and complications were documented via the patient's history. Further, a battery of patient-reported outcome measures (including patient satisfaction, WOMAC, Oxford, KOOS Jr, Forgotten Joint Score, and M-SANE) were obtained. Results. Of the original 88 patients in the study, 15 patients had a least one reoperation (17%). Patella problems were the most common cause of reoperation accounting for 5/8 reoperations in the KA group versus 3/7 in the MA group. There was no statistically significant difference between the two alignment methods in terms of major and minor complications or reoperations. At the 12-year
Aims. In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term
Aims. Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. Methods. This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years
Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’
Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean
The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs). This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.Aims
Methods
Abstract. Introduction. Approximately 15–20% of patients report chronic pain three months after total knee replacement (TKR). The STAR care pathway is a clinically important and cost-effective personalised intervention for patients with pain 3 months after TKR. The pathway comprises screening, assesment, onward referral for treatment and
Abstract. Background. Since 2012 we have routinely used the cementless Oxford medial unicompartmental knee arthroplasty (mUKA), with microplasty instrumentation, in patients with anteromedial osteoarthritis (AMOA) meeting modern indications. We report the 10-year survival of 1000 mUKA with minimum 4-year
Aims. We report the natural course of Baker’s cysts following total knee arthroplasty (TKA) at short- and mid-term
Abstract. Introduction. Transforming outpatient services is a key commitment set out in the NHS Long Term Plan, with particular emphasis on digital solutions to reduce outpatient
Introduction. Cementless TKA offers the potential for strong fixation through biologic fixation technology as compared to cemented TKA where fixation is achieved through mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs that have used additive manufacturing (3-D printing) for component design. The purpose of this study is to present minimum 5-year clinical outcomes and implant survivorship of a specific cementless TKA using a novel 3-D printed tibial baseplate. Methods. This is a single institution registry review of the prospectively obtained data on 296 cementless TKA using a novel 3-D printed tibial baseplate with minimum 5-year
Aims. Infection complicating primary total knee arthroplasty (TKA) is a common reason for revision surgery, hospital readmission, patient morbidity, and mortality. Increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) is a particular concern. The use of vancomycin as prophylactic agent alone or in combination with cephalosporin has not demonstrated lower periprosthetic joint infection (PJI) rates, partly due to timing and dosing of intravenous (IV) vancomycin administration, which have proven important factors in effectiveness. This is a retrospective review of a consecutive series of primary TKAs examining incidence of PJI, adverse reactions, and complications using IV versus intraosseous (IO) vancomycin at 30-day, 90-day, and one-year
Abstract. Introduction. Fractures of the articular surface of the patella or the lateral femoral condyle usually occur following acute dislocation of the patella. This study looked at the radiological and functional outcomes of fixation of osteochondral fractures. Methods. Twenty-nine patients (18 male, 11 female) sustained osteochondral fractures of the knee following patellar dislocation. All patients had detailed radiographic imaging and MRI scan of the knee preoperatively. An arthroscopic assessment was done, followed by fixation using bio-absorbable pins or headless screws either arthroscopically or mini-open arthrotomy. VMO plication or MPFL repair were done if necessary. MRI scan was done at
Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated high reliability of robotic-arm assisted UKA in component placement and executing a soft-tissue tensioning plan, with excellent short-term survivorship. Few studies have investigated survivorship and patients' satisfaction at longer follow-ups. Therefore, the purpose of the present study was to determine the survivorship, clinical results and patients' satisfaction of robotic-arm assisted UKAs at a mid-term
Background. The purpose of this study was to evaluate the clinical and radiographic outcomes of the rotating-platform, posterior-stabilized PFC Sigma at fifteen-year
Aims. There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes. Methods. A mid-term
Introduction. Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. However, there are few studies evaluating outcomes out to five years with a sufficient cohort. The purpose of this study was to evaluate implant survivorship and complications in revision TKAs with tibial cones. Methods. A retrospective review was completed from September 2006 through March 2018 evaluating 149 revision TKAs that received a tibial cone. The mean
Isolated patellofemoral osteoarthritis accounts for 10% of knee osteoarthritis. Many of these will not require arthroplasty solutions, but for those who are sufficiently symptomatic, patellofemoral joint (PFJ) replacement has been shown to be an effective procedure. The National Joint Registry (NJR) has shown a higher revision rate for this operation, particularly in younger patients (males <55 years 13.3% failure at 5 years, females 9.6%). The aim of this study is to report on the medium-term outcome of the Avon patellofemoral joint arthroplasty in patients under 55 from a non-design centre. There is no other published case series on this young patient cohort. 50 Avon PFJ replacements (Stryker, Kalamazoo USA) were undertaken in 46 patients under 55 years old (range 35 – 54, mean 48.8) between 2010 and 2022 for end-stage isolated PFJ arthritis shown on Xray and MRI scan. The outcome measure was all-cause revision rate. This was assessed by review of clinical notes, imaging and NJR data.Abstract
Introduction
Methodology