Advertisement for orthosearch.org.uk
Results 1 - 20 of 893
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1484 - 1489
1 Nov 2013
Meding JB Ritter MA Davis KE Farris A

The strain on clinic and surgeon resources resulting from a rise in demand for total knee replacement (TKR) requires reconsideration of when and how often patients need to be seen for follow-up. Surgeons will otherwise require increased paramedical staff or need to limit the number of TKRs they undertake. We reviewed the outcome data of 16 414 primary TKRs undertaken at our centre to determine the time to re-operation for any reason and for specific failure mechanisms. Peak risk years for failure were determined by comparing the conditional probability of failure, the number of failures divided by the total number of TKRs cases, for each year. The median times to failure for the most common failure mechanisms were 4.9 years (interquartile range (IQR) 1.7 to 10.7) for femoral and tibial loosening, 1.9 years (IQR 0.8 to 3.9) for infection, 3.1 years (IQR 1.6 to 5.5) for tibial collapse and 5.6 years (IQR 3.4 to 9.3) for instability. The median time to failure for all revisions was 3.3 years (IQR 1.2 to 8.5), with an overall revision rate of 1.7% (n = 282). Results from our patient population suggest that patients be seen for follow-up at six months, one year, three years, eight years, 12 years, and every five years thereafter. Patients with higher pain in the early post-operative period or high body mass index (≥ 41 kg/m. 2. ) should be monitored more closely. Cite this article: Bone Joint J 2013;95-B:1484–9


Bone & Joint Open
Vol. 5, Issue 10 | Pages 911 - 919
21 Oct 2024
Clement N MacDonald DJ Hamilton DF Gaston P

Aims. The aims were to assess whether joint-specific outcome after total knee arthroplasty (TKA) was influenced by implant design over a 12-year follow-up period, and whether patient-related factors were associated with loss to follow-up and mortality risk. Methods. Long-term follow-up of a randomized controlled trial was undertaken. A total of 212 patients were allocated a Triathlon or a Kinemax TKA. Patients were assessed preoperatively, and one, three, eight, and 12 years postoperatively using the Oxford Knee Score (OKS). Reasons for patient lost to follow-up, mortality, and revision were recorded. Results. A total of 94 patients completed 12-year functional follow-up (62 females, mean age 66 years (43 to 82) at index surgery). There was a clinically significantly greater improvement in the OKS at one year (mean difference (MD) 3.0 (95% CI 0.4 to 5.7); p = 0.027) and three years (MD 4.7 (95% CI 1.9 to 7.5); p = 0.001) for the Triathlon group, but no differences were observed at eight (p = 0.331) or 12 years’ (p = 0.181) follow-up. When assessing the OKS in the patients surviving to 12 years, the Triathlon group had a clinically significantly greater improvement in the OKS (marginal mean 3.8 (95% CI 0.2 to 7.4); p = 0.040). Loss to functional follow-up (53%, n = 109/204) was independently associated with older age (p = 0.001). Patient mortality was the major reason (56.4%, n = 62/110) for loss to follow-up. Older age (p < 0.001) and worse preoperative OKS (p = 0.043) were independently associated with increased mortality risk. An age at time of surgery of ≥ 72 years was 75% sensitive and 74% specific for predicting mortality with an area under the curve of 78.1% (95% CI 70.9 to 85.3; p < 0.001). Conclusion. The Triathlon TKA was associated with clinically meaningful greater improvement in knee-specific outcome when compared to the Kinemax TKA. Loss to follow-up at 12 years was a limitation, and studies planning longer-term functional assessment could limit their cohort to patients aged under 72 years. Cite this article: Bone Jt Open 2024;5(10):911–919


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 53 - 53
7 Aug 2023
Arthur J Makovicka J Bingham J Spangehl M Clarke H Dossett HG
Full Access

Abstract. Introduction. The optimal alignment technique for total knee replacement (TKR) remains controversial. We previously reported six-month and two-year results of a randomized controlled trial comparing kinematically (KA) versus mechanically (MA) aligned TKR. In the present study, we report 12-year results from this trial. Methods. The original cohort included 88 TKRs (44 KA using Shape Match patient-specific guides and 44 MA using conventional instrumentation), performed from 2008 to 2009. After IRB approval, the health record of the original 88 patients were queried. Revisions, re-operations, and complications were recorded. The non-deceased patients were contacted via phone. Reoperation and complications were documented via the patient's history. Further, a battery of patient-reported outcome measures (including patient satisfaction, WOMAC, Oxford, KOOS Jr, Forgotten Joint Score, and M-SANE) were obtained. Results. Of the original 88 patients in the study, 15 patients had a least one reoperation (17%). Patella problems were the most common cause of reoperation accounting for 5/8 reoperations in the KA group versus 3/7 in the MA group. There was no statistically significant difference between the two alignment methods in terms of major and minor complications or reoperations. At the 12-year follow-up, 26 patients died leaving 62 patients for follow-up. Of these, 48 patients (77%) were successfully contacted. The kinematically aligned total knees self-reported better satisfaction (96% versus 82%), but no difference in other patient-reported outcome measures compared to mechanically aligned TKRs. Conclusion. KA TKR demonstrates excellent mid to long-term results compared to MA TKR with similar reoperations, complications, and patient-reported outcome measures


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 840 - 845
1 May 2021
Rossi SMP Perticarini L Clocchiatti S Ghiara M Benazzo F

Aims. In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. Methods. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis. Results. The mean follow-up was nine years (6 to 13). All scores significantly improved from preoperatively to final follow-up (mean and SD): OKS from 23.2 (8.1) to 42.5 (3.5), EQ-5D from 0.44 (0.25) to 0.815 (0.1), EQ-VAS from 46.7 (24.9) to 89.1 (9.8), KSS (Knee) from 51.4 (8.5) to 94.4 (4.2), and KSS (Function) from 48.7 (5.5) to 88.8 (5.2). The mean FJS at final follow-up was 79.2 (4.2). All failures involved the medial UKA + PFA group. Overall, survival rate was 91.5% for all the combined implants at ten years with 95% confidence intervals and 22 knees at risk. Conclusion. Excellent clinical and radiological outcomes were achieved after a third-generation PFA combined with a medial or lateral UKA. BCA with unlinked partial knee prostheses showed a good survival rate at mid- to long-term follow-up. Cite this article: Bone Joint J 2021;103-B(5):840–845


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 32 - 37
1 Jun 2021
Restrepo S Smith EB Hozack WJ

Aims. Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. Methods. This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years follow-up. Outcomes were determined by comparing pre- and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores, and pre- and postoperative 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores. Aseptic loosening and revision for any reason were the endpoints which were used to determine survivorship at five years. Results. At mid-term follow-up, the mean KOOS JR score improved significantly from 33.14 (0 t0 85, standard deviation (SD) 21.88) preoperatively to 84.12 (15.94 to 100, SD 20.51) postoperatively (p < 0.001), the mean VR/SF-12 scores improved significantly from physical health (PH), 31.21 (SD 5.32; 23.99 to 56.77) preoperatively to 42.62 (SD 10.72; 19.38 to 56.82) postoperatively (p < 0.001) and the mental health (MH), 38.15 (SD 8.17; 19.06 to 60.75) preoperatively to 55.09 (SD 9.64; 19.06 to 66.98) postoperatively (p < 0.001). A total of 11 revisions were undertaken, with an overall revision rate of 2.94%, including five for periprosthetic joint infection (1.34%), three for loosening (0.80%), two for instability (0.53%), and one for pain (0.27%). The overall survivorship was 97.06% and survivorship for aseptic loosening as the endpoint was 98.40%, with a 99.5% survivorship of the 3D-printed tibial component. Conclusion. This 3D-printed cementless total knee system shows excellent survivorship at mid-term follow-up. This design and the ability to obtain cementless fixation offers promise for excellent long-term durability. Cite this article: Bone Joint J 2021;103-B(6 Supple A):32–37


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results. The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR ≥ 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of ≥ 0.17 at final follow-up. Conclusion. Patellar height gradually decreased over five years of follow-up after TKA. The reduction in patellar height beyond measurement error following TKA was associated with lower clinical outcomes. Cite this article: Bone Jt Open 2021;2(12):1075–1081


Bone & Joint Open
Vol. 5, Issue 10 | Pages 937 - 943
22 Oct 2024
Gregor RH Hooper GJ Frampton C

Aims

The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs).

Methods

This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 50 - 50
7 Aug 2023
Bertram W Wylde V Howells N Shirkey B Peters T Zhu L Noble S Moore A Beswick A Judge A Blom A Walsh D Eccleston C Bruce J Gooberman-Hill R
Full Access

Abstract. Introduction. Approximately 15–20% of patients report chronic pain three months after total knee replacement (TKR). The STAR care pathway is a clinically important and cost-effective personalised intervention for patients with pain 3 months after TKR. The pathway comprises screening, assesment, onward referral for treatment and follow-up over one year. In a multicentre randomised controlled trial comparing the pathway with usual care, the pathway improved pain at 6 and 12 months. This study examined the longer-term clinical and cost-effectiveness of the STAR care pathway. Methodology. STAR trial participants were followed-up at a median of 4 years post-randomisation. Co-primary outcomes were self-reported pain severity and interference in the replaced knee, assessed with the Brief Pain Inventory (BPI). Resource use from electronic hospital records was valued with UK reference costs. Results. Of the 337 participants active at trial completion, 326 had confirmed vital status, and 226 (69%) provided outcome data at a median of 4 years. The between-group difference in mean BPI severity score was −0.42 (95% CI −1.07, 0.23; p=0.20) and for BPI interference was −0.64 (95% CI −1.41, 0.12; p=0.10), favouring the intervention. Multiple imputation analyses led to attenuations of about 0.2 points. Mean hospital admission costs over four years were £2461.49 (95% CI £1354.42, £3568.57) in the intervention arm and £3791.68 (95% CI £2095.12, to £5488.24) in usual care. Conclusion. These data are consistent with sustained benefits from the STAR care pathway at 4 years, albeit attenuated and with wider confidence intervals, in part attributable to attrition after 1 year


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 30 - 30
1 Jul 2022
Middleton R Jackson W Alvand A Bottomley N Price A
Full Access

Abstract. Background. Since 2012 we have routinely used the cementless Oxford medial unicompartmental knee arthroplasty (mUKA), with microplasty instrumentation, in patients with anteromedial osteoarthritis (AMOA) meeting modern indications. We report the 10-year survival of 1000 mUKA with minimum 4-year follow-up. Methods. National Joint Registry (NJR) surgeon reports were interrogated for each senior author to identify the first 1,000 mUKAs performed for osteoarthritis. A minimum of 4 years follow-up was required. There was no loss to follow-up. The NJR status of each knee was established. For each mUKA revision the indication and mechanism of failure was determined using local patient records. The 10-year implant survival was calculated using life-table analysis. Results. The 1,000 mUKA cohort represented 55% of all primary knee replacements in the period, with an average age of 67.7 years and a 54%/46% male/female split. There were 17 revisions (11 for arthritis progression, 4 infections, 1 dislocation and 1 aseptic loosening). The 10-year survival was 98% (44 at risk in 10th year). One patient sustained a periprosthetic fracture at 3 weeks, treated with buttress plate fixation. Discussion. This is the first detailed series reporting the long-term outcome of the cementless Oxford mUKA implanted using microplasty instrumentation. There was a low failure rate, with only one revision for aseptic loosening. Lateral progression was the commonest cause for revision, with an incidence of 1%. This report provides evidence that the combination of evidence-based indications, well-designed instrumentation and cementless fixation can provide excellent long-term survival for the Oxford mUKA in treating AMOA


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 132 - 136
1 Jan 2020
Hommel H Becker R Fennema P Kopf S

Aims. We report the natural course of Baker’s cysts following total knee arthroplasty (TKA) at short- and mid-term follow-up. Methods. In this prospective case series, 105 TKA patients were included. All patients who received surgery had a diagnosis of primary osteoarthritis and had preoperatively presented with a Baker’s cyst. Sonography and MRI were performed to evaluate the existence and the gross size of the cyst before TKA, and sonography was repeated at a mean follow-up time of 1.0 years (0.8 to 1.3; short-term) and 4.9 years (4.0 to 5.6; mid-term) after TKA. Symptoms potentially attributable to the Baker’s cyst were recorded at each assessment. Results. At the one-year follow-up analysis, 102 patients were available. Of those, 91 patients were available for the 4.9-year assessment (with an 86.7% follow-up rate (91/105)). At the short- and mid-term follow-up, a Baker’s cyst was still present in 87 (85.3%) and 30 (33.0%) patients, respectively. Of those patients who retained a Baker’s cyst at the short-term follow-up, 31 patients (35.6%) had popliteal symptoms. Of those patients who continued to have a Baker’s cyst at the mid-term follow-up, 17 patients (56.7%) were still symptomatic. The mean preoperative cyst size was 14.5 cm. 2. (13.1 to 15.8). At the short- and mid-term follow-up, the mean cyst size was 9.7 cm. 2. (8.3 to 11.0) and 10.4 cm. 2. (9.8 to 11.4), respectively. A significant association was found between the size of the cyst at peroperatively and the probability of resolution, with lesions smaller than the median having an 83.7% (36/43) probability of resolution, and larger lesions having a 52.1% (25/48) probability of resolution (p < 0.001). At the mid-term follow-up, no association between cyst size and popliteal symptoms was found. Conclusion. At a mean follow-up of 4.9 years (4.0 to 5.6) after TKA, the majority (67.0%, 61/91) of the Baker’s cysts that were present preoperatively had disappeared. The probability of cyst resolution was dependent on the size of the Baker’s cyst at baseline, with an 83.7% (36/43) probability of resolution for smaller cysts and 52.1% (25/48) probability for larger cysts. Cite this article: Bone Joint J. 2020;102-B(1):132–136


Abstract. Introduction. Transforming outpatient services is a key commitment set out in the NHS Long Term Plan, with particular emphasis on digital solutions to reduce outpatient follow-up (FU) by 25%. This study looks at the potential for removing knee arthroscopy FU by providing a bespoke multimedia report for each individual patient, generated using the Synergy™ Surgeon App (Arthrex). Methodology. Single District Hospital using a 3 Phase study. Phase 1 – Assessment of cost and environmental impact of outpatient follow up appointments. Phase 2 – Bench marking of existing pathways and patient experience. Phase 3 – Qualitative assessment of multimedia report feedback of 30 patients. Results. Phase 1 – Impact per year for Trust in released clinician time 135hrs. Cost avoidance £40-£60k. Reduction of the carbon footprint from reduced FU of 3132 KgCo2e2. Phase 2 – Deep dive on 2019 n. 353 procedures. 1206 outpatient appointments required. Average 1.2 post-operative appointments. Phase 3 – 87% of patients who received the e-op report needed no further FU. This compares to only 25% using a traditional post op discussion after surgery. 94% of patients felt the report aided their recovery. Conclusions. Reducing patient FU appointments is crucial to the future of the NHS. Achieving this whilst simultaneously improving the quality of patient communication is achievable as this study has demonstrated. The potential scalability of this project to be applied other arthroscopic procedures is enormous. The study has demonstrated patients are comfortable with modern technology and feel it enhances their understanding whilst decreasing the need for routine post-op FU


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 71 - 71
1 Oct 2020
Restrepo S Hozack WJ Smith EB
Full Access

Introduction. Cementless TKA offers the potential for strong fixation through biologic fixation technology as compared to cemented TKA where fixation is achieved through mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs that have used additive manufacturing (3-D printing) for component design. The purpose of this study is to present minimum 5-year clinical outcomes and implant survivorship of a specific cementless TKA using a novel 3-D printed tibial baseplate. Methods. This is a single institution registry review of the prospectively obtained data on 296 cementless TKA using a novel 3-D printed tibial baseplate with minimum 5-year follow-up. Outcomes were determined by comparing pre- and post-operative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores and pre- and post-operative 12 item Veterans RAND/Short Form Health Survey (VR/SF-12). Aseptic loosening as well as revision for any reason were the endpoints used to determine survivorship at 5 years. Results. At minimum 5-year follow-up, the KOOS JR score improved from 34.88 pre-operatively to 84.29 post-operatively (p-values = 0.0001), the VR/SF-12 scores improved from PH − 31.98 pre-operatively to 42.80 post-operatively (p-values = 0.0001) and the MH − 37.24 pre-operatively to 55.16 post-operatively (p-value = 0.0001). Eleven revisions were performed for an overall revision rate of 2.94% - including 5 PJI (1.34%), 3 loosening (0.80%), 1 instability (0.27%), 2 pain (0.53%). The overall 5-year survivorship was 97.1% and survivorship for aseptic loosening as the endpoint was 98.40%. The survivorship of the 3-D printed porous tibial component was 99.2%. Conclusion. This 3-D printed tibial baseplate and cementless total knee system shows excellent survivorship at 5-year follow-up. The design of this implant and the ability to obtain cementless fixation offers promise for excellent long-term durability


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 13 - 17
1 Jun 2021
Park KJ Chapleau J Sullivan TC Clyburn TA Incavo SJ

Aims. Infection complicating primary total knee arthroplasty (TKA) is a common reason for revision surgery, hospital readmission, patient morbidity, and mortality. Increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) is a particular concern. The use of vancomycin as prophylactic agent alone or in combination with cephalosporin has not demonstrated lower periprosthetic joint infection (PJI) rates, partly due to timing and dosing of intravenous (IV) vancomycin administration, which have proven important factors in effectiveness. This is a retrospective review of a consecutive series of primary TKAs examining incidence of PJI, adverse reactions, and complications using IV versus intraosseous (IO) vancomycin at 30-day, 90-day, and one-year follow-up. Methods. A retrospective review of 1,060 patients who underwent TKA between May 2016 to July 2020 was performed. There were 572 patients in the IV group and 488 in the IO group, with minimal 30 days of follow-up. Patients were followed up at regularly scheduled intervals (two, six, and 12 weeks). No differences between groups for age, sex, BMI, or baseline comorbidities existed. The IV group received an IV dose of 15 mg/kg vancomycin given over an hour preceding skin incision. The IO group received a 500 mg dose of vancomycin mixed in 150 ml of normal saline, injected into proximal tibia after tourniquet inflation, before skin incision. All patients received an additional dose of first generation cephalosporin. Evaluation included preoperative and postoperative serum creatinine values, tourniquet time, and adverse reactions attributable to vancomycin. Results. Incidence of PJI with minimum 90-day follow-up was 1.4% (eight knees) in the IV group and 0.22% (one knee) in IO group (p = 0.047). This preliminary report demonstrated an reduction in the incidence of infection in TKA using IO vancomycin combined with a first-generation cephalosporin. While the study suffers from limitations of a retrospective, multi-surgeon investigation, early findings are encouraging. Conclusion. IO delivery of vancomycin after tourniquet inflation is a safe and effective alternative to IV administration, eliminating the logistical challenges of timely dosing. Cite this article: Bone Joint J 2021;103-B(6 Supple A):13–17


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 89 - 89
1 Jul 2022
Rajput V Iqbal S Salim M Anand S
Full Access

Abstract. Introduction. Fractures of the articular surface of the patella or the lateral femoral condyle usually occur following acute dislocation of the patella. This study looked at the radiological and functional outcomes of fixation of osteochondral fractures. Methods. Twenty-nine patients (18 male, 11 female) sustained osteochondral fractures of the knee following patellar dislocation. All patients had detailed radiographic imaging and MRI scan of the knee preoperatively. An arthroscopic assessment was done, followed by fixation using bio-absorbable pins or headless screws either arthroscopically or mini-open arthrotomy. VMO plication or MPFL repair were done if necessary. MRI scan was done at follow-up to assess for healing of the fixed fragment prior to patient discharge. Results. The mean age of the patients was 21 yrs (9–74), 11 had osteochondral fracture of the patella (38%), while 18 were from the lateral femoral condyle (62%). 13 patients needed additional VMO plication. Mean follow up period was 7.7 years (1 to 12 years). As per Tegner activity scale, all patients returned to their pre-injury activity level (Mean score 7) and sports. None of the patients had a further episode of patellar dislocation. Mean postoperative IKDC score was 86.5 (SD 17.3), Kujala was 91.1(SD 15.5) and Tegner- lysholm was 88.7 (SD 14.4). All patients had statistically significant (p < 0.05) improvement. Post-operative MRI scan showed satisfactory union in all cases (100%). Conclusion. It is extremely important to identify this group of injury and treat them early to have satisfactory knee function and avoid long term complications of arthritis


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 7 - 7
1 Oct 2019
Catani F Ensini A Zambianchi F Illuminati A Matveitchouk N
Full Access

Introduction. Robotic technology has been applied to unicompartmental knee arthroplasty (UKA) in order to improve surgical precision in prosthetic component placement, restore knee anatomic surfaces, and provide a more physiologic ligament tensioning throughout the knee range of motion. Recent literature has demonstrated high reliability of robotic-arm assisted UKA in component placement and executing a soft-tissue tensioning plan, with excellent short-term survivorship. Few studies have investigated survivorship and patients' satisfaction at longer follow-ups. Therefore, the purpose of the present study was to determine the survivorship, clinical results and patients' satisfaction of robotic-arm assisted UKAs at a mid-term follow-up, with a minimum of 5 years of follow-up. Methods. The present retrospective study includes 252 patients (260 knees) who underwent robotic-arm assisted fixed bearing metal backed UKAs at a single centre between April 2011 and July 2013. The mean age at surgery was 66.2 years (SD 8.6). Post-operatively, patients were administered the Forgotten Joint Score-12 (FJS) and asked about their satisfaction level after knee surgery (grade from 1 to 5). Post-operative complications were recorded. Failure mechanisms, revisions and reoperations were also assessed. Kaplan-Meier survival curves were calculated, considering reoperation for all causes and revision as the events of interest. Results. A total of 223 patients (231 robotic-arm assisted UKAs) were assessed at a mean follow-up of 5.8 years post-operatively (88.5% follow-up rate, min. 60 months, max. 87 months). In 219 cases, a medial robotic-arm assisted UKA was implanted, in 12 cases a lateral implant was performed. Five medial robotic-arm assisted UKAs were revised, resulting in a survivorship of 98% (C.I. 96.0%–99.1%). One case underwent revision for prosthetic joint infection, one for tibial aseptic loosening, one for post-traumatic tibial plateau fracture, and two for unexplained pain. No lateral robotic-arm assisted UKAs were revised, resulting in a survivorship of 100%. On average, the FJS and the satisfaction level resulted 75.6 (SD 26.1) and 4.2 (SD 1.0) in medial UKAs, and 81.7 (SD 15.3) and 4.4 (SD 0.8) in lateral UKAs, respectively. In medial UKAs 83% of the examined cohort reported good/excellent FJS outcomes, while 92% of the lateral UKA patients had good/excellent FJS results. In medial UKAs, male patients resulted to have better FJS (p<0.01) and higher satisfaction level (p<0.03) compared to female patients, while no outcome differences were reported in patients with BMI>30 and among different age groups. Given the small number of lateral UKAs included in the present patients' cohort, no statistical analysis was performed on this group. Conclusion. In the present study, survivorship and clinical outcomes of a large cohort of 223 patients undergoing medial and lateral robotic-arm assisted UKAs were assessed at a mean of 5.8 years of follow-up. The overall survivorship was found to be 98%, with unexplained knee pain as the most common reason for UKA revision. The present study shows that robotic-arm assisted UKA patients had lower revision rates for aseptic loosening and osteoarthritis progression compared to conventional UKA at mid-term follow-up, as reported in the literature. The good post-operative clinical scores highlight the efficacy of robotic-arm assisted UKA in restoring knee function and relieving pain. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 62 - 62
1 Oct 2019
White PB Satalich J Ranawat AS Ranawat CS
Full Access

Background. The purpose of this study was to evaluate the clinical and radiographic outcomes of the rotating-platform, posterior-stabilized PFC Sigma at fifteen-year follow-up. Methods. Between January 2000 and November 2001, two hundred consecutive patients underwent TKA with a rotating-platform, posterior stabilized total knee arthroplasty with cement. All patients have been followed prospectively and all patients with minimum 12 year follow up were included in this analysis. Forty-nine TKAs were available for our final analysis with a mean follow up of 16.0 years. Results. The improvements in Knee Society pain and function scores were 44 to 83. The 15-year Koos Jr interval scores for cohort was 76.2. The range of motion improved from 111° to 115°. The prevalence of residual pain was 32.5%, painless crepitation was 15% and 5% reporting painful crepitation at 15-year follow up via PROMs. Kaplan-Meier analysis revealed that the survivorship was 100% due to mechanical failure as an endpoint, and 95% as reoperation as an end-point. Conclusions. At fifteen-year follow up, the rotating-platform, posterior stabilized arthroplasty demonstrated excellent survivorship and radiographic results. Peripatellar crepitation, occasionally requiring excision, remains an issue. For figures, tables, or references, please contact authors directly


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 434 - 441
1 Apr 2020
Hamilton DF Burnett R Patton JT MacPherson GJ Simpson AHRW Howie CR Gaston P

Aims. There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes. Methods. A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints. Results. The mean follow-up of the 125 patients was 8.12 years (7.3 to 9.4). There was a reduction in all assessment parameters relative to earlier assessments. Longitudinal models highlight changes over time in all parameters and demonstrate large effect sizes. Significant between-group differences were seen in measures of knee flexion (medium-effect size), lower limb power output (large-effect size), and report of worst daily pain experienced (large-effect size) favouring the Triathlon group. No longitudinal between-group differences were observed in mean OKS, average daily pain report, or timed performance test. Satisfaction with outcome in surviving patients at eight years was 90.5% (57/63) in the Triathlon group and 82.8% (48/58) in the Kinemax group, with no statistical difference between groups (p = 0.321). Conclusion. At a mean 8.12 years, this mid-term follow-up of a randomized controlled trial cohort highlights a general reduction in measures of patient function with patient age and follow-up duration, and a comparative preservation of function based on implant received at time of surgery. Cite this article: Bone Joint J 2020;102-B(4):434–441


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 54 - 54
1 Oct 2020
Hernandez NM Hinton ZW Wu CJ Ryan SP Bolognesi† MP
Full Access

Introduction. Tibial cones are often utilized in revision total knee arthroplasty (TKA) with metaphyseal defects. However, there are few studies evaluating outcomes out to five years with a sufficient cohort. The purpose of this study was to evaluate implant survivorship and complications in revision TKAs with tibial cones. Methods. A retrospective review was completed from September 2006 through March 2018 evaluating 149 revision TKAs that received a tibial cone. The mean follow-up was 5.3 years. According to the AORI classification: 8% were 1, 18% were 2A, 55% were 2B, and 19% were 3. Results. Survival analysis at 6 years showed 96% free of revision for aseptic tibial loosening, 85% free of tibial component revision for any reason, and 72% free of reoperation. Eleven knees had progressive radiolucent lines with eight having tibial construct migration on serial radiographs. Aseptic tibial loosening was associated with significant tibial bone loss, AORI 3 (p=0.0001). Tibial component revision for any reason was associated with AORI 3 (p=0.013) and a pre-revision diagnosis of reimplantation after PJI (p<0.0001). Four knees had revision for aseptic tibial loosening, 12 knees had revision of the tibial construct for reasons other than aseptic loosening (11/12 were for PJI), and 15 knees had reoperation for reasons other than tibial construct revision. Conclusions. Revision TKA with tibial cones had excellent survivorship free of revision for tibial construct aseptic loosening, 96% at 6 years. Patients receiving a tibial cone construct at the time of reimplantation for PJI were at increased risk for tibial construct revision


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 39 - 39
7 Aug 2023
Hainsworth L Lankester B
Full Access

Abstract

Introduction

Isolated patellofemoral osteoarthritis accounts for 10% of knee osteoarthritis. Many of these will not require arthroplasty solutions, but for those who are sufficiently symptomatic, patellofemoral joint (PFJ) replacement has been shown to be an effective procedure. The National Joint Registry (NJR) has shown a higher revision rate for this operation, particularly in younger patients (males <55 years 13.3% failure at 5 years, females 9.6%). The aim of this study is to report on the medium-term outcome of the Avon patellofemoral joint arthroplasty in patients under 55 from a non-design centre. There is no other published case series on this young patient cohort.

Methodology

50 Avon PFJ replacements (Stryker, Kalamazoo USA) were undertaken in 46 patients under 55 years old (range 35 – 54, mean 48.8) between 2010 and 2022 for end-stage isolated PFJ arthritis shown on Xray and MRI scan. The outcome measure was all-cause revision rate. This was assessed by review of clinical notes, imaging and NJR data.