Advertisement for orthosearch.org.uk
Results 1 - 20 of 51
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 168 - 168
1 May 2012
Appleyard R Donnellan M Sears W
Full Access

Existing techniques of posterior multi-point C1/2 stabilisation are technically demanding and can be hazardous. The coauthors have recently reported successful atlantoaxial fusion using a novel C1/2 stabilisation technique employing C1 multi-axial posterior arch screws (MA-PAS) in a clinical series of three patients where anatomical anomalies precluded established techniques. The technically less demanding nature of this new technique, and possible wider application in patients with normal anatomy, led the authors to investigate its biomechanical stability compared to other established techniques. Twenty-four human fresh-frozen cadaveric spines were harvested C0-C5. Motion was restricted to between C0 and C4. Each spine was non-destructively tested in flexion/extension, lateral bending and axial rotation, firstly in the intact state and then after Type 2 odontoid fracture destabilisation and insertion of Magerl-Gallie, Unicortical Harms, Bicortical Harms or MA-PAS instrumentation. ROM between C1 and C2 was monitored using two digital cameras. Results for each technique were compared statistically compared using ANOVA. The C1-C2 joint of the intact spines demonstrated high flexibility in flexion/extension (16.5deg). After instrumentation all specimens showed significantly reduced ROM in flexion/extension (Magerl-Gallie FE = 4.2deg, Unicort Harms FE = 7.2deg, Bicort Harms FE = 4.4deg). Lateral bend ROM of instrumented specimens (Magerl-Gallie LB =3.8deg, Unicort Harms LB = 3.8deg, Bicort Harms LB =2.3 deg) was, however, similar or slightly greater than intact (2.7 deg) . MA-PAS showed similar ROM in flexion/extension (4.2 deg) as the Magerl-Gallie and Harms techniques but was slightly higher in lateral bend (5.3 deg). The MA-PAS technique was shown to have similar biomechanical stability to the Magerl-Gallie and Harms techniques. Given the demonstrated biomechanical stability of the MA-PAS technique, it may be a suitable alternative to the existing technically demanding, and possibly more hazardous, multi-point fixation techniques in patients with normal, as well as anomalous, C1/2 segmental anatomy


Anatomic reduction (subcapital re-alignment osteotomy) via surgical hip dislocation – increasingly popular. While the reported AVN rates are very low, experiences seem to differ greatly between centres. We present our early experience with the first 29 primary cases and a modified fixation technique. We modified the fixation from threaded Steinman pins to cannulated 6.5mm fully-threaded screws: retrograde guidewire placement before reduction of the head ensured an even spread in the femoral neck and head. The mean PSA (posterior slip angle) at presentation (between 12/2008 and 01/2011) was overall 68° (45–90°). 59% (17/29) were stable slips (mean PSA 68°), and 41% (12/29) were unstable slips unable to mobilise (mean PSA 67°). The vascularity of the femoral head was assessed postoperatively with a bone scan including tomography. The slip angle was corrected to a mean PSA of 5.8° (7° anteversion to 25° PSA). We encountered no complications related to our modified fixation technique. All cases with a well vascularised femoral head on the post-operative bone scan (15/17 stable slips and 8/12 unstable slips) healed with excellent short term results. Both stable slips with decreased vascularity on bone scan (2/17, 12%) had been longstanding severe slips with retrospectively suspected partial closure of the physis, which has been described as a factor for increased risk of avascular necrosis (AVN). One of these cases was complicated by a posterior redislocation due to acetabular deficiency. In the unstable group, 4/12 cases (33%) had avascular heads intra-operatively and cold postoperative bone scans, 3 have progressed to AVN and collapse. Anatomic reduction while sparing the blood supply of the femoral head is a promising concept with excellent short term results in most stable and many unstable SCFE cases. Extra vigilance for closed/closing physes in longstanding severe cases seems advisable. Regardless of treatment, some unstable cases inevitably go on to AVN


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 69 - 69
1 Dec 2022
Clarke M Beaudry E Besada N Oguaju B Nathanail S Westover L Sommerfeldt M
Full Access

Meniscal root tears can result from traumatic injury to the knee or gradual degeneration. When the root is injured, the meniscus becomes de-functioned, resulting in abnormal distribution of hoop stresses, extrusion of the meniscus, and altered knee kinematics. If left untreated, this can cause articular cartilage damage and rapid progression of osteoarthritis. Multiple repair strategies have been described; however, no best fixation practice has been established. To our knowledge, no study has compared suture button, interference screw, and HEALICOIL KNOTLESS fixation techniques for meniscal root repairs. The goal of this study is to understand the biomechanical properties of these fixation techniques and distinguish any advantages of certain techniques over others. Knowledge of fixation robustness will aid in surgical decision making, potentially reducing failure rates, and improving clinical outcomes. 19 fresh porcine tibias with intact medial menisci were randomly assigned to four groups: 1) native posterior medial meniscus root (PMMR) (n = 7), 2) suture button (n = 4), 3) interference screw (n = 4), or 4) HEALICOIL KNOTLESS (n = 4). In 12 specimens, the PMMR was severed and then refixed by the specified group technique. The remaining seven specimens were left intact. All specimens underwent cyclic loading followed by load-to-failure testing. Elongation rate; displacement after 100, 500, and 1000 cycles; stiffness; and maximum load were recorded. Repaired specimens had greater elongation rates and displacements after 100, 500, and 1000 cycles than native PMMR specimens (p 0.05). The native PMMR showed greater maximum load than all repair techniques (p 0.05). In interference screw and HEALICOIL KNOTLESS specimens, failure occurred as the suture was displaced from the fixation and tension was gradually lost. In suture button specimens, the suture was either displaced or completely separated from the button. In some cases, tear formation and partial failure also occurred at the meniscus luggage tag knot. Native PMMR specimens failed through meniscus or meniscus root tearing. All fixation techniques showed similar biomechanical properties and performed inferiorly to the native PMMR. Evidence against significant differences between fixation techniques suggests that the HEALICOIL KNOTLESS technique may present an additional option for fixation in meniscal root repairs. While preliminary in vitro evidence suggests similarities between fixation techniques, further research is required to determine if clinical outcomes differ


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 10 - 10
22 Nov 2024
Frank F Hotchen A Valand P Stubbs D Ferguson J McNally M
Full Access

Aim. This retrospective study evaluated the outcome of treatment for unhealed fracture-related infections (FRI). Methods. We identified a consecutive, single-centre cohort of patients having treatment for an FRI Consensus confirmed FRI. All fractures were unhealed at the time of treatment. Patients were followed up for at least one year. Successful outcome was a healed fracture without recurrent infection. Lack of union, persistent infection and/or unplanned reoperation defined failure. Results. Demographics: 183 patients (184 FRIs) with mean age 52.1 years (range 17-96) were treated and followed up for a mean of 2.8 years (range 1-9.4). Mean duration of FRI was 1.1 years with 65 (35.5 %) presenting within 6 months of injury. 118 patients had established infected non-union. FRI was most frequent in the tibia (74), femur (48) and humerus (24). 171 patients were BACH Complex. 75.5% of FRIs were culture positive, with Staph. aureus being the most frequent organism. Polymicrobial infection and Gram negative cultures were common (25.5% and 33.6%). Treatment: 98.3% of surgeries were performed in one stage with just 3 planned 2-stage procedures (2 endoprosthetic replacements and 1 free fibular flap). No bone graft was used in any surgery and all wounds were closed at first operation. 48 cases (26%) required flap coverage (29 free flaps and 19 local flaps). Local antibiotics were used in 124 cases (67.4%) of primary surgeries. All patients had sampling, debridement, systemic antibiotics and wound closure. 40 (21.7%) had DAIR, 31 (16.8%) had new internal fixation and 105 (57.1%) had external fixation (including 79 Ilizarov fixators). Outcomes: After primary surgery, 84.6% of all patients were infection-free and 77.2% had united. After further surgery, 98.8% were infection-free and 98.1% had united. External fixation techniques achieved infection eradication in 89.1% compared to 71.7% with any internal fixation (p=0.005). Primary internal fixation achieved union in 81.7% compared to 74.3% with external fixation (p=0.27). Secondary surgery after external fixation was mainly docking site fixation. Conclusion. Unhealed FRIs present a difficult challenge for treatment. This large series demonstrated that single-stage treatment, without bone grafting, gave acceptable results with few reoperations. Primary external fixation gave more certainty of infection eradication but required more reoperations to secure union. However, this difference in reoperation was not statistically significant. We strongly advocate managing these patients with a multidisciplinary team which can treat all aspects of the condition


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 89 - 89
1 Dec 2022
Kitzen J Paulson K Edwards B Bansal R Korley R Duffy P Dodd A Martin R Schneider P
Full Access

Dual plate constructs have become an increasingly common fixation technique for midshaft clavicle fractures and typically involve the use of mini-fragment plates. The goal of this technique is to reduce plate prominence and implant irritation, as these are common reasons for revision surgery. However, limited biomechanical data exist for these lower-profile constructs. The study aim was to compare dual mini-fragment orthogonal plating to traditional small-fragment clavicle plates for biomechanical non-inferiority and to determine if an optimal plate configuration could be identified, using a cadaveric model. Twenty-four cadaveric clavicles were randomized to one of six groups (n=4 per group), stratified by CT-based bone mineral content (BMC). The six different plating configurations compared were: pre-contoured superior or anterior fixation using a single 3.5-mm LC-DC plate, and four different dual-plating constructs utilizing 2.4-mm and 2.7-mm reconstruction or LC-DC plates. The clavicles were plated and then osteotomized to create an inferior butterfly fracture, which was then fixed with a single interfragmentary screw (OTA 15.2B). Axial, torsional, and bending (anterior and superior surface loading) stiffness were determined for each construct through non-destructive cyclic testing, using an MTS 858 Bionix materials testing system. This was followed by a load-to-failure test in three-point superior-surface bending. Kruskal-Wallace H and Mann-Whitney U were used to test for statistical significance. There were no significant differences in BMC (median 7.9 g, range 4.2-13.8 g) for the six groups (p=1.000). For axial stiffness, the two dual-plate constructs with a superior 2.4-mm and anterior 2.7-mm plate (either reconstruction or LC-DC) were significantly stiffer than the other four constructs (p=0.021). For both superior and anterior bending, the superior 2.4-mm and anterior 2.7-mm plate constructs were significantly stiffer when compared to the 3.5-mm superior plate (p=0.043). In addition, a 3.5-mm plate placed anterior was a stiffer construct than a superior 3.5-mm plate (p=0.043). No significant differences were found in torsional stiffness or load-to-failure between the different constructs. Dual plating using mini-fragment plates is biomechanically superior for fixation of midshaft clavicle fractures when compared to a single superior 3.5-mm plate and has similar biomechanical properties to a 3.5-mm plate placed anteriorly. With the exception of axial stiffness, no significant differences were found when different dual plating constructs were compared to each other. However, placing a 2.4-mm plate superiorly in combination with a 2.7-mm plate anteriorly might be the optimal construct, given the biomechanical superiority over the 3.5-mm plate placed superior


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_7 | Pages 2 - 2
1 May 2018
Sinnett T Sabharwal S Sinha I Griffiths D Reilly P
Full Access

We present a case series of patients who underwent 3 or 4 part proximal humerus fracture fixation using an intra-osseous suture technique. 18 patients are included in the study with follow up data obtained ranging from 1 to 4 years. Oxford Shoulder Scores (OSS) and range of movement measurements were taken for all patients. The mean OSS for the group was 50/60 with a mean forward flexion of 140°, abduction of 132°, external rotation of 48° and internal rotation to the level 10. th. thoracic vertebra. Three patients developed adhesive capsulitis, 2 requiring subsequent arthroscopic release. This data compares favourably to outcomes reported in the literature with hemiarthroplasty or locking plate fixation. An activity based costing analysis estimated that the treatment costs for proximal humerus fractures was approximately £2,055 when performing a soft tissue reconstruction, £3,114 when using a locking plate and £4,679 when performing a hemiarthroplasty. This demonstrates a significant financial saving when using intra-osseous fixation compared to other fixation techniques. We advocate the use of the intra-osseous suture fixation technique for certain 3 and 4 part fractures. It gives good functional outcomes, significant cost savings and potentially makes revision procedures easier when compared to other fixation techniques


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 22 - 22
1 Feb 2020
Van De Kleut M Athwal G Yuan X Teeter M
Full Access

Introduction. Reverse total shoulder arthroplasty (RTSA) is rapidly being adopted as the standard procedure for a growing number of shoulder arthropathies. Though short-term outcomes are promising, mid- and long-term follow-ups present a number of complications – among them, humeral stem and glenosphere component loosening. Though not the primary complication, previously reported aseptic loosening required revision in 100% of cases. As the number of patients undergoing RTSA increases, especially in the younger population, it is important for surgeons to identify and utilize prostheses with stable long-term fixation. It has previously been shown in the hip and knee literature that implant migration in the first two years following surgery is predictive of later failure due to loosening in the 5=10-year postoperative window. The purpose of this study is to, for the first time, evaluate the pattern and total magnitude of implant migration in reverse shoulder arthroplasty using the gold standard imaging technique radiostereometric analysis (RSA). Methods. Forty patients were prospectively randomized to receive either a cemented or press-fit humeral stem, and a glenosphere secured to the glenoid with either autologous bone graft or 3D printed porous titanium for primary reverse total shoulder arthroplasty. Following surgery, participants are imaged using RSA, a calibrated, stereo x-ray technique. Radiographs are acquired at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem and glenosphere at each time point is compared to baseline. Migration of the prostheses is independently compared between humeral stem fixation groups and glenosphere fixation groups using a two-way repeated measures ANOVA with Tukey's test for multiple comparisons. Results. Follow-ups are ongoing and preliminary results are presented. Significant differences were observed at the 6-month and 1-year time points for superior-inferior translation (p = 0.0067, p = 0.0048), and total three-dimensional translation (p = 0.0011, p = 0.0272) between humeral stems, with press-fit humeral stems subsiding significantly more than cemented stems. Migration between the 6-month and 1-year time points was minimal for both stem fixation groups (less than 0.2 mm). No significant differences were observed along any axis at any time point for the glenosphere fixation groups. Conclusion. There is a trend towards increased subsidence with the use of press-fit stems compared to cemented stems in the first six months postoperatively, as is expected. Both implant fixation techniques demonstrate stability from six months through one year, and this trend is expected through two-year follow-up. Similarly, both glenosphere fixation techniques demonstrate immediate and stable fixation through one year


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 32 - 32
1 Mar 2021
Lapner P McRae S Leiter J McIlquham K MacDonald P
Full Access

Controversy exists regarding the optimal technique for arthroscopic rotator cuff repair. No previous comparative trials have reported on the long-term follow-up of single and double row fixation in arthroscopic cuff repair. The purpose of this study was to compare the long-term functional outcomes of single-row and double-row suture techniques for repair of the rotator cuff 10-years post-operatively. Ninety patients undergoing arthroscopic rotator cuff repair were randomized to receive either single-row or double-row repair. The primary objective was to compare the Western Ontario Rotator Cuff Index (WORC) score 10-years post-operatively. Secondary objectives included comparison of the Constant, and American Shoulder and Elbow Surgeons (ASES) scores and supraspinatus strength between groups. Out of 90 patients originally randomized, 57 returned for the long-term 10-year follow-up. Baseline demographic data did not differ between groups. The WORC score was not significantly different between groups at long-term follow-up (p=0.13). No statistical differences were observed between groups for the Constant (p=0.51), ASES (p=0.48) scores, or strength scores (p=0.93). A significant improvement was observed between pre-operative and the final 10-year follow-up. There were no differences observed in all outcomes between two and 10-years post-operatively. No statistically significant differences in functional or quality of life outcomes were identified between single-row and double-row fixation techniques at long-term follow-up


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 10 - 10
1 Jun 2021
Van Tienen T Defoort K van de Groes S Emans P Heesterbeek P Pikaart R
Full Access

Introduction. Post-meniscectomy syndrome is broadly characterised by intractable pain following the partial or total removal of a meniscus. There is a large treatment gap between the first knee pain after meniscectomy and the eligibility for a TKA. Hence, there is a strong unmet need for a solution that will relieve this post-meniscectomy pain. Goal of this first-in-man study was to evaluate the safety and performance of an anatomically shaped artificial medial meniscus prosthesis and the accompanying surgical technique. Methods. A first-in-man, prospective, multi-centre, single arm clinical investigation was intended to be performed on 18 post-medial meniscectomy syndrome patients with limited underlying cartilage damage (Kellgren Lawrence scale 0–3) in the medial compartment and having a normal lateral compartment. Eventually 5 patients received a polycarbonate urethane mediale meniscus prosthesis (Trammpolin® medial meniscus prosthesis; ATRO Medical B.V., the Netherlands) which was clicked onto two titanium screws fixated at the native horn attachments on the tibia. PROMs were collected at baseline and at 6 weeks, 3, 6, 12 and 24 months following the intervention including X-rays at 6, 12 and 24 Months. MRI scans were repeated after 12 and 24 months. Results. The surgical technique to select the appropriately sized implant and correct positioning of the fixation screws and meniscus prosthesis onto the tibia was demonstrated feasible and reproducible. The surgeries showed that in particular the positioning of the posterior screw is crucial for correct positioning of the prosthesis. Inclusion stopped after 5 patients, who reached the 6 months evaluation. The PROMs did not improve in the first 6 months after surgery. All patients reported knee joint stiffness and slight effusion in their knee at 6 months follow-up. In case of symptomatic patients an evaluation of the device position and integrity was performed by MRI. In three patients the implants were removed because of implant failure and in one patient the implant was removed because of persistent pain and extension deficit. At present one patient has the implant still in situ. The explantations of the implants demonstrated no articular cartilage damage and the fixation screws were securely anchored. Discussion. This is the first clinical study with an artificial meniscus-like prosthesis. Except one, all implants were removed due to implant breakage or discomfort of the patient. Analysis of the torn implants showed fatigue failure resulting from the lack of loadsharing between implant and cartilage: the implant was too stiff and carried all the load in the medial compartment of the knee. Furthermore, the fixation with screws seemed too rigid which restricted the motion of the posterior horn. Based on previous in vitro and animal experiments, we expected more creep of the material and more motion on the screw fixation. Conclusion. This first-in-man clinical study demonstrates that the investigated device design is not safe and did not perform as expected. Therefore, modification of the meniscus prosthesis design and fixation technique is required to allow for more motion of the meniscus prosthesis during knee joint movement


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 58 - 58
1 Mar 2021
Dehghan N Nauth A Schemitsch E Vicente M Jenkinson R Kreder H McKee M
Full Access

Unstable chest wall injuries have high rates of mortality and morbidity. These injuries can lead to respiratory dysfunction, and are associated with high rates of pneumonia, sepsis, prolonged ICU stays, and increased health care costs. Numerous studies have demonstrated improved outcomes with surgical fixation compared to non-operative treatment. However, an adequately powered multi-centre randomized controlled study using modern fixation techniques has been lacking. We present a multi-centred, prospective, randomized controlled trial comparing surgical fixation of acute, unstable chest wall injuries with the current standard of non-operative management. Patients aged 16–85 with a flail chest (3 or more consecutive, segmental, displaced rib fractures), or severe deformity of the chest wall, were recruited from multiple trauma centers across North America. Exclusion criteria included: severe pulmonary contusion, severe head trauma, randomization>72 hours from injury, inability to perform surgical fixation within 96 hours from injury (in those randomized to surgery), fractures of the floating ribs, or fractures adjacent to the spine not amendable to surgical fixation. Patients were seen in follow-up for one year. The primary outcome was days free from mechanical ventilation in the first 28 days following injury. Secondary outcomes were days in ICU, rates of pneumonia, sepsis, need for tracheostomy, mortality, general health outcomes, pulmonary function testing, and other complications of treatment. A sample size of 206 was required to detect a difference of 2 ventilator-free days between the two groups, using a 2-tailed alpha error of 0.05 and a power of 0.80. A total of 207 patients were recruited from 15 sites across Canada and USA, from 2011–2018. Ninety-nine patients were randomized to non-operative treatment, and 108 were randomized to surgical fixation. Overall, the mean age was 53 years, and 75% of patients were male, with 25% females. The commonest mechanisms of injury were: motor vehicle collisions (34%), falls (20%), motorcycle collisions (14%), and pedestrian injuries (11%). The mean injury severity score (ISS) at admission was 26, and patients had a mean of 10 rib fractures. Eighty-nine percent of patients had pneumothorax, 76% had haemothorax, and 54% had pulmonary contusion. There were no differences between the two groups in terms of demographics. The final results will be available and presented at the COA meeting in Halifax. This is the largest randomized controlled trial to date, comparing surgical fixation to non-operative treatment of unstable chest wall and flail chest injuries. The results of this study will shed light on the best treatment options for patients with such injuries, help understand outcomes, and guide treatment. The final results will be available and presented at the COA meeting in Halifax


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 14 - 14
1 Apr 2019
Van De Kleut M Athwal G Yuan X Teeter M
Full Access

Introduction. Total shoulder arthroplasty is the fastest growing joint replacement in recent years, with projected compound annual growth rates of 10% for 2016 through 2021 – higher than those of both the hip and knee combined. Reverse total shoulder arthroplasty (RTSA) has gained particular interest as a solution for patients with irreparable massive rotator cuff tears and failed conventional shoulder replacement, for whom no satisfactory intervention previously existed. As the number of indications for RTSA continues to grow, so do implant designs, configurations, and fixation techniques. It has previously been shown that continuous implant migration within the first two years postoperatively is predictive of later loosening and failure in the hip and knee, with aseptic loosening of implant components a guaranteed cause for revision in the reverse shoulder. By identifying implants with a tendency to migrate, they can be eliminated from clinical practice prior to widespread use. The purpose of this study is to, for the first time, evaluate the pattern and magnitude of implant component migration in RTSA using the gold standard imaging technique radiostereometric analysis (RSA). Methods. Forty patients were prospectively randomized to receive either a cemented or press-fit humeral stem, and a glenosphere secured to the glenoid with either autologous bone graft or 3D printed porous titanium (Aequalis Ascend Flex, Wright Medical Group, Memphis, TN, USA) for primary reverse total shoulder arthroplasty. Following surgery, partients are imaged using RSA, a calibrated, stereo x-ray technique, at 6 weeks (baseline), 3 months, 6 months, 1 year, and 2 years. Migration of the humeral stem and glenosphere at each time point is compared to baseline. Preliminary results are presented, with 15 patients having reached the 6-month time point by presentation. Results. Implant migration of ten participants at the 3-month time point is presented. Maximum total point motion (MTPM) is a measure of translation and rotation of the point on the implant that has moved the most from baseline. Average MTPM ± SD of the humeral stem is 1.18 ± 0.65 mm and 0.98 ± 0.46 mm for press-fit (n = 6) and cemented (n = 4) stems, respectively; and 0.25 ± 0.09 mm and 0.47 ± 0.24 mm for bone graft (n = 4) and porous titanium (n = 6) glenosphere fixations, respectively, at the 3-month time point. Conclusion. There is a trend towards increased migration with the use of press-fit humeral stems and porous titanium glenosphere fixation, though no conclusions can be made from the current sample size. Further, though differences in migration magnitude may be observed at early postoperative time points, it is expected that all fixation techniques will show stability from 1 to 2 years postoperatively


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 56 - 56
1 Mar 2021
Schneider P Thoren J Cushnie D Del Balso C Tieszer C Sanders D
Full Access

Flexible fixation techniques combined with anatomic (open) syndesmosis reduction have demonstrated improved functional outcomes and rates of malreduction. Suture-button devices allow physiologic motion of the syndesmosis without need for implant removal, which may lower the risk of recurrent syndesmotic diastasis. There is limited longer-term assessment of the maintenance of reduction between static and flexible syndesmotic fixation using bilateral ankle CT evaluation. This is an a priori planned subgroup analysis of a multi-centre, randomized clinical trial comparing static syndesmosis fixation (two 3.5 mm screws) with flexible fixation (single knotless Tightrope) for patients with AO- OTA 44-C injuries. Patients who completed bilateral ankle CT scans at 3- and 12-month follow-up were included. The primary outcome measure was syndesmotic malreduction based on bilateral ankle CT scans, using the uninjured, contralateral ankle as a control. Anterior (ASD), middle (MSD), and posterior (PSD) syndesmosis distance were calculated to measure syndesmosis reduction. Secondary outcomes included re-operation, adverse events and functional outcomes including the EQ5D, Olerud-Molander Ankle Score (OM), Foot and Ankle Disability Index (FADI), and Work Productivity Activity Impairment Questionnaire (WPAI). Paired samples t-tests were used to compare injured to control ankles (R, v 3.5.1). 42 patients (24 Group S, 18 Group T) were included. ASD for Group T was 5.22mm (95%CI 4.69–5.77) at 3 months compared to 4.26mm (95%CI 3.82–4.71; p=0.007) in controls and 5.38mm (95%CI 4.72–6.04) at 12 months compared to 4.44mm (95%CI 3.73–5.16; p=0.048) in controls. ASD for Group S was 4.63mm (95%CI 4.17– 5.10) at 3 months compared to 4.67mm (95%CI 4.24–5.10; p=0.61) in controls, but significantly increased to 5.73mm (95%CI 4.81–6.66) at 12 months compared to 4.65mm (95%CI 4.15–5.15; p=0.04) in controls. MSD results were similar; Group T had a larger MSD than control ankles at 3 months (p=0.03) and 12 months (p=0.01), while the MSD in Group S was not different at 3 months (p=0.80) but increased at 12 months (p=<0.01). 88% (21/24) of Group S had broken or removed screws by 12 months. Unplanned re-operation was 15% in Group S and 4% in Group T (p=0.02), with an overall re-operation rate of 30% in Group S. There was no significant difference between treatment groups for EQ-5D, OM, FADI or WPAI at 3- or 12-month follow-up. Tightrope fixation resulted in greater diastasis of the ASD and MSD compared to contralateral, uninjured ankles at 3- and 12-months post-fixation. Group S initially had syndesmotic reduction similar to control ankles, but between 3- and 12-months post-fixation, there was significantly increased syndesmosis diastasis compared to controls. The majority of Group S (88%) had either broken screws or scheduled screw removal, which may explain the increased tibio-fibular diastasis seen at 12-months


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 34 - 34
1 Dec 2016
Pathy R Sturnick D Blanco J Dodwell E Scher D
Full Access

Fixation of tendon transfers about the foot in children typically involves creating a bone tunnel through which a suture is passed and tied over an external button. An internal suspension system, such as the Endobutton (Smith & Nephew) is an alternative fixation method which has demonstrated excellent fixation strength and minimal intraosseous tunnel displacement in various adult procedures. Application of the Endobutton technique has no risk of skin ulceration, does not require suture removal and may provide more secure fixation. The purpose of this study is to compare the biomechanical properties of the external button and Endobutton fixation techniques. Our primary outcome measure was intra-osseous displacement of the suture, during both static and dynamic loading, in cadaver feet. Nine adult cadaver feet were utilised. A bone tunnel was drilled in the lateral cuneiform and #1 braided non-absorbable suture was passed through the tunnel. One end was secured to a carabiner to be attached to the materials testing system and the other to the fixation device. The external button and Endobutton fixation techniques were tested once in each cadaver, randomising the order of testing to minimise bias. Each fixation technique underwent static and dynamic cyclic loading. A custom Matlab script was used to process video and materials testing system data. The relative displacement of the suture within the bone tunnel, as a function of time and load magnitude, was recorded during static and dynamic cyclic loading. Both fixation groups were analysed and compared for statistical significance using a paired T-test and an alpha value of 0.05. The Endobutton group had significantly less displacement within the bone tunnel, during both static and dynamic loading, than the external button. The average displacement during static loading was 0.42 mm for the Endobutton and 2.17 mm for the external button (p=0.0019). Similarly, during dynamic cyclic loading, the mean displacement was 0.32 mm for the Endobutton and 0.66 mm for the external button (p=0.0115). The Endobutton internal suspension technique demonstrates significantly less displacement during static and dynamic loading than the external button, during biomechanical testing in cadaver feet. The Endobutton may provide superior fixation than the traditional external button technique for tendon transfers in children. In addition, this technique avoids the risk of skin ulceration from the button and the need for suture removal


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 79 - 79
1 May 2019
Engh C
Full Access

The most common classification of periprosthetic femoral fractures is the Vancouver classification. The classification has been validated by multiple centers. Fractures are distinguished by location, stability of the femoral component, and bone quality. Although postoperative and intraoperative fractures are classified using the same three regions, the treatment algorithm is slightly different. Type A fractures involve the greater and lesser trochanter. Fractures around the stem or just distal to the stem are Type B and subcategorised depending on stem stability and bone quality. Type C fractures are well distal to the stem and are treated independent of the stem with standard fixation techniques. The majority of fractures are either B1 (stable stem) or B2 (unstable stem). The stem is retained and ORIF of the fracture performed for B1 fractures. B2 and B3 fractures require stem revision with primary stem fixation distal to the fracture. Intraoperative fractures use the same A, B, C regions but are subtyped 1–3 as cortical perforations, nondisplaced, and displaced unstable fractures, respectively. With the exception of A1 intraoperative fractures all other intraoperative fractures require surgical treatment. A recent publication utilizing a New York state registry highlighted the patient risk of mortality associated with periprosthetic hip fractures. One month, 6 month and 1 year mortality was 3.2%, 3.8% and 9.7%, respectively. The mortality risk was lower for periprosthetic fractures treated with ORIF at 1 and 6 months compared to fractures requiring revision total hip


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_3 | Pages 2 - 2
1 Apr 2019
Mannan A Walmsley K Mandalia V Schranz P
Full Access

Background. The meniscal deficient knee often exists in the setting of associated pathology including instability, malalignment and chondral injury. Meniscal allograft transplantation (MAT) is established to be a reliable option in restoring function and treating symptoms. The aim of this study was to establish the role of MAT as part of a staged approach to treatment of the previously menisectomised knee. Methods. This prospective study included all patients that underwent arthroscopic MAT at our institution between 2010 to 2017. Fresh frozen allograft was utilised using a soft tissue fixation technique. Further data was collected for index surgical procedures before and after MAT. Data for pre and post-operative Knee Injury and osteoarthritis outcome scores (KOOS), Tegner scores, graft survival, reoperation rates, patient satisfaction and MRI extrusion measurements were collected and details of any further surgical intervention and / or complications also documented. Results. Twenty seven MAT procedures were performed in 26 patients. Sixteen patients underwent lateral MAT and 11 patients medial. Ten patients underwent ACL reconstruction, three ACI and two, osteotomy in the pre-MAT phase. A further seven patients underwent ACI within the post-operative phase. The post-operative mean KOOS scores improved significantly in all subscales as did Tegner scores. Graft survival was 100%, satisfaction rate 92%, and mean meniscal extrusion 3.04mm. Post operatively, three patients required meniscal repair and a single patient partial menisectomy of graft. Two patients underwent arthroscopic arthrolysis following MAT. Conclusions. This series highlights the multifactorial profile of the meniscal deficient knee and the role of MAT as a safe and reliable technique in the staged and comprehensive biologic treatment available to minimise symptoms and maximise outcomes


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 9 - 9
1 Sep 2014
Badenhorst D Van der Westhuizen C
Full Access

Introduction. Fixation of the distal fibula in conjunction with ankle fractures has not changed over the last 50 years. The complication rate of these fixation techniques is as high as 30%. The fibula nail is an alternative method of fixation and uses a minimal invasive technique. This technique preserves soft tissue compared to previous techniques used, and fewer soft tissue complications. Method. We reviewed the preliminary results of 178 patients with unstable Weber B and C ankle fractures that were operated on in our unit between January 2012 and February 2013. We used the Acumed fibular nail for reduction and fixation of the lateral malleolus. Using the nail we had significant reduction in our operating time. Patients were discharged one day post operation without any POP and partial weight bearing on crutches. Various parameters were measured on all the follow- up x-rays and assessed for incongruencies compared with the normal ankle. These parameters were medial clearspace, talo-crural angle, talar tilt and fibular length. No patients thus far have had any loss of fixation. The Olerud and Molander score was used at three month and six month follow up. Results. Patients at three months scored an average of 80 and at six months an average of 85. There were no cases of non-union. 40 patients had systemic co-morbidities. We had four superficial wound complications that healed well with antibiotics and daily wound care. Conclusion. The fibula nail is an effective fixation technique for most Weber B and C ankle fractures. It causes minimal destruction of the soft tissue. Functional outcome of patients is excellent. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 110 - 110
1 May 2013
Jones R
Full Access

There are special circumstances in which revision total knee arthroplasty is not an option. The relative indications for the alternatives to revision TKA are: - Recurrent deep infection - Immunocompromised patient - Extensor mechanism loss - Extensive, non-reconstructable soft tissue loss - High functional demand, young age Remember the three A's as alternatives to revision TKA: arthrodesis, arthroplasty (resection), and amputation. Successful arthrodesis requires elimination of infection, coaptation of bone surfaces and rigid immobilisation. The proper position for arthrodesis is 15 degrees of knee flexion to allow foot clearance. If bone loss is greater than 3 cm fuse the knee in full extension. Avoid hyperextension. Achieve 5 degrees of valgus in correct rotation and use intramedullary instruments from TKA sets for best cuts. External fixation techniques as well as intramedullary internal fixation techniques will be described. Resection arthroplasty is indicated for salvage of an infected total knee when the patient is not a candidate for reimplantation. These patients usually have extensive soft and hard tissue loss. Procedure may be well tolerated and functional. Ancillary support with a long leg drop- lock KAFO increases stability and provides motion. Patients finding resection unacceptable are more likely to accept fusion or amputation; therefore resection may be a staging procedure. Amputation is indicated for failed multiple revisions, intractable or life threatening infection. Also should be indicated when there is a low chance of a successful arthrodesis. Ablate at the lowest level for infection eradication but good maintenance of function. Pedicle muscle flaps can be useful to fill dead spaces. Remember, elderly patients have limited ambulation potential because of high energy requirements of above knee amputation


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 132 - 132
1 Sep 2012
Vasarhelyi EM Yach J
Full Access

Purpose. Anterior column screw fixation has been a useful tool in the management of acetabular fractures, either alone or in combination with other fixation techniques. Percutaneous insertion may be advantageous by limiting surgical dissection but little has been reported on its safety. The purpose of this study is to report on the efficacy and safety of percutaneous anterior column stabilization. Method. In a consecutive series of 122 operatively treated acetabular fractures, 56 patients were treated with antegrade percutaneous anterior column stabilization either alone or in combination with other fixation techniques by a single surgeon (JY). The technique was selected when the anterior column portion of the fracture was undisplaced or could be reduced via indirect methods. Intraoperative fluoroscopy was used to guide the placement of either a 6.5 mm or 7.3 mm cannulated antegrade anterior column lag screw. Postoperative radiographs (anteroposterior and Judet views) were obtained in the recovery room, prior to discharge and at clinic follow up. Results. The mean age of patients in the series was 52 years (range 17 91). Mean follow up was 13 months. There was one death from associated injuries. Based on the classification system described by Letournel, there were 22 anterior column, 8 transverse, 11 transverse / posterior wall, 9 anterior column / posterior hemitransverse, 1 associated both column and 5 T-type fractures. There were no vascular, neurologic, or urologic complications in the series. There were no cases of intraarticular screw placement. In two cases, the screw did not completely cross the entire fracture line on postoperative radiographs. There were no cases of hardware failure or loss of reduction. There were two cases of hardware removal for hardware prominence. There was one case of chronic proximal femur osteomyelitis, and two cases requiring subsequent total hip arthroplasty for associated injuries. All fractures healed. Conclusion. This study supports percutaneous anterior column stabilization as a safe and effective technique in the treatment of selected acetabular fractures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 481 - 481
1 Dec 2013
Kurdziel M Wiater B Moravek J Pinkas D Wiater JM
Full Access

Purpose:. Glenoid loosening persists as a common cause of anatomic total shoulder arthroplasty (TSA) failure. Considering radiographic evidence of loosening as an endpoint, TSA has a reported survivorship of only 51.5% at 10 years. Component loosening may be related to cementation and it is postulated that poor cement penetration and heat-induced necrosis may partially be responsible. There is a growing interest among surgeons to minimize or abandon cement fixation and rely on biologic fixation to the polyethylene for long-term fixation. De Wilde et al. reported promising early clinical and radiographic results using a pegged, all-polyethylene ingrowth glenoid design implanted without cement. The goal of this study was to compare glenoid micromotion in an all-polyethylene, centrally fluted pegged glenoid using 3 cement fixation techniques. Materials and Methods:. Glenoid components (Anchor Peg Glenoid, Depuy Orthopaedics, Warsaw, IN, USA) (Figure 1) were implanted in polyurethane foam testing blocks with 3 different fixation methods (n = 5 per group). Group I glenoids were implanted with interference fit fixation with no added cement. Group II was implanted with a hybrid fixation, where only the peripheral pegs were cemented. Group III glenoids were fully cemented for implantation. Glenoid loosening was characterized according to ASTM Standard F-2028. The glenoid component and a 44 mm humeral head were mounted to a materials testing frame (858 Mini Bionix II, MTS Crop., Eden Prairie, MN, USA) with a 750N applied joint compressive force (Figure 1). A humeral head subluxation displacement of ± 0.5 mm was experimentally calculated as a value that simulates glenoid rim loading that may occur at higher load activities. For characterization of glenoid loosening, the humeral head was cycled 50,000 times along the superior-inferior glenoid axis, simulating approximately 5 years of device service. Glenoid distraction, compression, and superior-inferior glenoid migration were recorded with two differential variable reluctance transducers fixed to the glenoid prosthesis. Results:. All glenoid components completed the 50,000 cycles of humeral head translation successfully. With respect to glenoid distraction (Figure 2), interference fit fixation had significantly greater distraction compared to both hybrid and fully cemented fixation (p < 0.001). Hybrid fixation also displayed significantly higher distraction compared to fully cemented fixation (p < 0.001). In terms of glenoid compression (Figure 2), hybrid cementation had significantly greater compression compared to both interference-fit and fully cemented fixation (p < 0.001). Discussion:. This is the first biomechanics study comparing glenoid micromotion of a centrally fluted, pegged component using 3 different fixation techniques. Of all fixation methods, the fully cemented components displayed the least amount of motion in all parameters. Hybrid fixation exhibited lower distraction, higher compression, and comparable translation compared to interference-fit fixation. Results may indicate the differences in early motion and suggest little to no advantage of peripheral peg cementation over no cement with respect to initial fixation. Future studies are warranted to further evaluate interference-fit fixation as a viable option for implantation of a central fluted, all-polyethylene glenoid component


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 89 - 89
1 Feb 2017
Levy J Kurowicki J
Full Access

Background. Peri-prosthetic humerus fractures are relatively uncommon occurrences that can be difficult to manage non-operatively. Locking plate technology has enhanced the surgical management of these fractures. We describe an osteosynthesis technique utilizing a locking plate with eccentrically placed screw holes to place “skive screws” in the proximal end of the plate to achieve fixation around the stem of the implant. Methods. A retrospective review of prospectively collected data was performed for a consecutive series of patients treated with this skive screw technique from May 2011 to September 2014. Seven patients presented with postoperative type B peri-prosthetic humerus fractures. Average follow-up was 24 months. Radiographic analysis was performed on most recent postoperative imaging. Clinical outcomes were assessed using VAS pain, ASES total score, ASES functional score, SST, SANE, range of motion and strength. Results. At an average of follow-up of 24 months, all patients demonstrated fracture healing. Functional outcomes were limited with only two patients achieving forward elevation above 90 degrees and average ASES Function score was 27.5. Pain relief was nearly uniform with an average VAS Pain score of 0.5 (Figure 1). Conclusions. Peri-prosthetic humeral shaft fractures can be successfully treated with hybrid fixation technique using a locking plate with eccentric holes that facilitate placement of proximal “skive screws”. Using this technique, a 100% union rate was observed with excellent pain relief