Advertisement for orthosearch.org.uk
Results 1 - 20 of 132
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 192 - 192
1 Sep 2012
Tomaszewski P Verdonschot N Bulstra S Verkerke G
Full Access

For amputated patients, direct attachment of upper leg prosthesis to the skeletal system by a percutaneous implant is an alternative solution to the traditional socket fixation. Currently available implants, the OPRA system (Integrum AB, Göteborg, Sweden) and the ISP Endo/Exo prosthesis (ESKA Implants AG, Lübeck, Germany) [1-2] allow overcoming common soft tissue problems of conventional socket fixation and provide better control of the prosthetic limb [3], higher mobility and comfort [2, 4]. However, restraining issues such as soft-tissue infections, peri-prosthetic bone fractures [3, 5–8] and considerable bone loss around the stem [9], which might lead to implant's loosening, are present. Finally, a long a residual limb is required for implant fitting. In order to overcome the limiting biomechanical issues of the current designs, a new concept of the direct intramedullary fixation was developed. The aim was to restore the natural load transfer in the femur and allow implantations in short femur remnants (Figure 1). We hypothesize that the new design will reduce the peri-prosthetic bone failure risk and adverse bone remodeling. Generic CT-based finite element models of an intact femoral bone and amputated bones implanted with 3 analyzed implants were created for the study. Models were loaded with two loading cases from a normal walking obtained from the experimental measurements with the OPRA device [10-11]. Periprosthetic bone failure risk was evaluated by considering the von Mises stress criterion [12-14]. Subsequently the strain adaptive bone remodeling theory was used to predict long-term changes in bone mineral density (BMD) around the implants. The bone mineral content (BMC) change was measured around implants and the results were visualized in the form of DXA scans. The OPRA and the ISP implants induced the high stress concentration in the proximal region decreasing in the distal direction to values below physiological levels as compared with the intact bone. The stresses around the new design were more uniformly distributed along the cortex and resembled better the intact case. Consequently, the bone failure risk was reduced as compared to the OPRA and the ISP implants. The adaptive bone remodeling simulations showed high bone resorption around distal parts of the OPRA and the ISP implants in the distal end of the femur (on average −75% ISP to −78% OPRA after 60 months). The bone remodeling simulation did not reveal any bone loss around the new design, but more bone densification was seen (Figure 2). In terms of total bone mineral content (BMC) the OPRA and the ISP implants induced only a short-term bone densification in contrast to the new design, which provoked a steady increase in the BMC over the whole analyzed period (Figure 3). In conclusion, we have seen that the new design offers much better bone maintenance and lower failure probability than the current osseointegrated trans-femoral prostheses. This positive outcome should encourage further developments of the presented concept, which in our opinion has a potential to considerably improve safety of the rehabilitation with the direct fixation implants and allow treatment of patients with short stumps


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1210 - 1215
1 Sep 2017
Parker MJ Cawley S

Aims

To compare the outcomes for trochanteric fractures treated with a sliding hip screw (SHS) or a cephalomedullary nail.

Patients and Methods

A total of 400 patients with a trochanteric hip fracture were randomised to receive a SHS or a cephalomedullary nail (Targon PFT). All surviving patients were followed up to one year from injury. Functional outcome was assessed by a research nurse blinded to the implant used.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 679 - 682
1 Jul 1991
Bostman O

We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 592 - 596
1 Jul 1990
Bostman O Hirvensalo E Makinen J Rokkanen P

Biodegradable rods of polyglycolide or lactide-glycolide copolymer were used in the internal fixation of a variety of fractures and osteotomies in 516 patients. A clinically manifest foreign-body reaction occurred in 41 patients (7.9%), producing a fluctuant swelling at the implantation site after an average of 12 weeks. Spontaneous sinus formation or surgical drainage yielded a sterile exudate containing liquid remnants of the degrading implants. After prompt drainage this discharge subsided within three weeks. Histological examination showed a typical nonspecific foreign-body reaction with abundant giant cells both in patients with the reaction and in some patients with an uneventful clinical course. The factors determining the nature of the reaction were probably related to the local capacity of the tissues to clear the polymeric debris. The reactions did not influence the clinical or radiographic results, but recognition of the incidence and the features of the reaction is necessary in view of the increasing use of such implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 725 - 731
1 Jul 1999
Overgaard S Bromose U Lind M Bünger C Søballe K

We inserted two hydroxyapatite (HA)-coated implants with crystallinities of either 50% (HA-50%) or 75% (HA-75%) bilaterally into the medial femoral condyles of the knees of 16 dogs. The implants were allocated to two groups with implantation periods of 16 and 32 weeks. They were weight-bearing and subjected to controlled micromovement of 250 μm during each gait cycle. After 16 weeks, mechanical fixation of the HA-50% implants was increased threefold as compared with the HA-75% implants. After 32 weeks there was no difference between HA-50% and HA-75%. Fixation of HA-75% increased from 16 to 32 weeks whereas that of HA-50% was unchanged. HA-50% implants had 100% more bone ingrowth than HA-75% implants after 16 weeks. More HA coating was removed on HA-50% implants compared with HA-75% implants after both 16 and 32 weeks. No further loss of the HA coating was shown from 16 to 32 weeks. Our study suggests that the crystallinity of the HA coating is an important factor in its bioactivity and resorption during weight-bearing conditions. Our findings suggest two phases of coating resorption, an initial rapid loss, followed by a slow loss. Resorbed HA coating was partly replaced by bone ingrowth, suggesting that implant fixation will be durable


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 410 - 410
1 Apr 2004
Omizu N Ito H Tanino H Matsuno T
Full Access

The use of prostheses with porous surfaces in cementless total hip arthroplasty now predominates. Beads are popular for use as a porous coating, but their mechanical strength may be insufficient because of displacement of some of the beads from the coating. In this study, we propose a new porous surface, created by making direct holes in the metal surface using a YAG laser. A titanium-alloy (Ti-6Al-4V) rod was used. A Bead-type prosthesis was made by diffusion bonding pure titanium beads to the rod; it was 5 mm in diameter and 35% in porosity. A Laser type was made by directly creating holes in the same rod surface using a YAG laser; it was 5 mm in diameter and 33.7% in porosity. Both implants were evaluated in vivo using the hemitranscortical cylindrical model in two beagle dogs. Four prostheses were implanted into each femur through the lateral cortex, for a total of eight of each type, and remained in place for 12 weeks. Except for the proximal implant, push-out tests were performed to measure the shear strength of fixation of the implants to the cortical bone. For observations of the implant-bone interface, decalcified specimens of the proximal femur were stained with toluidine blue and observed with an optical microscope. The mean push-out strength of the Laser type was approximately 10.2 MPa and that of the Beads type was approximately 10.7 MPa. There was no significant difference in interface push-out strength between the groups. Bone ingrowth into both types was sufficient, however, some specimens of the Beads type demonstrated displacement of some of the beads from the rod surface. This study indicates that a porous surface created with a YAG laser might be useful not only for its shear strength, but also for the strength of the surface itself.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 121 - 126
1 Jan 2007
Jensen TB Overgaard S Lind M Rahbek O Bünger C Søballe K

Impacted bone allograft is often used in revision joint replacement. Hydroxyapatite granules have been suggested as a substitute or to enhance morcellised bone allograft. We hypothesised that adding osteogenic protein-1 to a composite of bone allograft and non-resorbable hydroxyapatite granules (ProOsteon) would improve the incorporation of bone and implant fixation. We also compared the response to using ProOsteon alone against bone allograft used in isolation. We implanted two non-weight-bearing hydroxyapatite-coated implants into each proximal humerus of six dogs, with each implant surrounded by a concentric 3 mm gap. These gaps were randomly allocated to four different procedures in each dog: 1) bone allograft used on its own; 2) ProOsteon used on its own; 3) allograft and ProOsteon used together; or 4) allograft and ProOsteon with the addition of osteogenic protein-1. After three weeks osteogenic protein-1 increased bone formation and the energy absorption of implants grafted with allograft and ProOsteon. A composite of allograft, ProOsteon and osteogenic protein-1 was comparable, but not superior to, allograft used on its own. ProOsteon alone cannot be recommended as a substitute for allograft around non-cemented implants, but should be used to extend the volume of the graft, preferably with the addition of a growth factor


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 41 - 41
2 Jan 2024
Singh S Dhar S Kale S
Full Access

The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria. A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics. Comminuted metaphyseal fractures might differ in pattern and presentation with every patient and there can be no standard treatment for all. The cantilever technique of fracture fixation is based on the principle of cantilever mechanism used in bridges and helps achieve good anatomical reduction and fixation. It provides a decent alternative when standard modes of fixation don't give desired result owing to comminuted nature of fractures and deficiency of bone stock


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 7 - 7
1 Dec 2023
Jones M Pinheiro V Church S Ball S Williams A
Full Access

Introduction. To determine if elite athletes can return to professional sport after MCL or posterolateral (PLC) reconstruction using LARS ligaments. The secondary aims are to demonstrate the safety and efficacy of LARS by reporting sport longevity, subsequent surgeries, and complications. Methods. A retrospective review of all extra-articular knee ligament reconstructions, utilising a LARS synthetic ligament, by 3 sports knee surgeons between 2013 and 2020 was undertaken. All elite athletes aged over 16 years and a minimum of 2 years post reconstruction were included. No LARS were used for ACL reconstructions, and they were excluded if a LARS ligament was used for a PCL reconstruction. Return to play (RTP) was defined as competing at professional level or national/ international level in amateur sport. Results. Sixty-four (84.2%) MCL reconstructions and 12 (15.8%) PLC reconstructions were included. 52 (68.4%) underwent concomitant autograft cruciate(s) reconstruction including 6 (7.8%) bicruciate reconstructions. The mean age was 25.1 years (SD +/− 4.50). 35 (46.1%) were footballers and 35 (46.1%) were rugby players. Sixty-seven athletes (88.2%) returned to elite sport, 7 (9.2%) did not RTP and RTP status was unknown for 2 (2.6%) (Figure 1). 65 out of 67 (97.0%) RTP at the same/higher Tegner level. 56 (83.6%) and 20 (57.1%) were still playing at 2- and 5-years post-surgery Six (7.9%) players required further surgery due to irritation from the metal fixation implants. One had an inflammation adjacent to the synthetic material at the femoral end and the other cases involved the tibial staples. All six cases were able to RTP. One athlete, following bicruciate /MCL surgery had the LARS removed due to laxity. There was one MCL re-rupture, sustained while jumping, 4 years after returning to football. Conclusions. Utilising LARS in extra-articular knee ligament reconstructions allows 88.2% of athletes with a variety of knee ligament injuries to return to elite sport. The results compare well regarding RTP, complication, and revision rates with the published evidence for other types of MCL and PLC grafts. This, coupled with 57% of athletes still playing 5 years post-surgery suggests the LARS is safe and effective in these cases. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 80 - 80
1 Dec 2022
Reeves J Spangenberg G Elwell J Stewart B Vanasse T Roche C Langohr GD Faber KJ
Full Access

Shoulder arthroplasty is effective at restoring function and relieving pain in patients suffering from glenohumeral arthritis; however, cortex thinning has been significantly associated with larger press-fit stems (fill ratio = 0.57 vs 0.48; P = 0.013)1. Additionally, excessively stiff implant-bone constructs are considered undesirable, as high initial stiffness of rigid fracture fixation implants has been related to premature loosening and an ultimate failure of the implant-bone interface2. Consequently, one objective which has driven the evolution of humeral stem design has been the reduction of stress-shielding induced bone resorption; this in-part has led to the introduction of short stems, which rely on metaphyseal fixation. However, the selection of short stem diametral (i.e., thickness) sizing remains subjective, and its impact on the resulting stem-bone construct stiffness has yet to be quantified. Eight paired cadaveric humeri (age = 75±15 years) were reconstructed with surgeon selected ‘standard’ sized and 2mm ‘oversized’ short-stemmed implants. Standard stem sizing was based on a haptic assessment of stem and broach stability per typical surgical practice. Anteroposterior radiographs were taken, and the metaphyseal and diaphyseal fill ratios were quantified. Each humerus was then potted in polymethyl methacrylate bone cement and subjected to 2000 cycles of compressive loading representing 90º forward flexion to simulate postoperative seating. Following this, a custom 3D printed metal implant adapter was affixed to the stem, which allowed for compressive loading in-line with the stem axis (Fig.1). Each stem was then forced to subside by 5mm at a rate of 1mm/min, from which the compressive stiffness of the stem-bone construct was assessed. The bone-implant construct stiffness was quantified as the slope of the linear portion of the resulting force-displacement curves. The metaphyseal and diaphyseal fill ratios were 0.50±0.10 and 0.45±0.07 for the standard sized stems and 0.50±0.06 and 0.52±0.06 for the oversized stems, respectively. Neither was found to correlate significantly with the stem-bone construct stiffness measure (metaphysis: P = 0.259, diaphysis: P = 0.529); however, the diaphyseal fill ratio was significantly different between standard and oversized stems (P < 0.001, Power = 1.0). Increasing the stem size by 2mm had a significant impact on the stiffness of the stem-bone construct (P = 0.003, Power = 0.971; Fig.2). Stem oversizing yielded a construct stiffness of −741±243N/mm; more than double that of the standard stems, which was −334±120N/mm. The fill ratios reported in the present investigation match well with those of a finite element assessment of oversizing short humeral stems3. This work complements that investigation's conclusion, that small reductions in diaphyseal fill ratio may reduce the likelihood of stress shielding, by also demonstrating that oversizing stems by 2mm dramatically increases the stiffness of the resulting implant-bone construct, as stiffer implants have been associated with decreased bone stimulus4 and premature loosening2. The present findings suggest that even a small, 2mm, variation in the thickness of short stem humeral components can have a marked influence on the resulting stiffness of the implant-bone construct. This highlights the need for more objective intraoperative methods for selecting stem size to provide guidelines for appropriate diametral sizing. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 64 - 64
2 May 2024
Lamb J West R Relton S Wilkinson M Pandit H
Full Access

Current estimates of periprosthetic fracture risk associated with femoral implants is mostly limited to revision only estimates and does not accurately represent stem performance. The aim of this study was to estimate the risk of surgically treated post-operative periprosthetic femoral fracture (POPFF) more accurately associated with frequently used femoral implants used for total hip arthroplasty (THA). A cohort study of patients who underwent primary THA in England between January 1, 2004, and December 31, 2020. Periprosthetic fractures were identified from prospectively collected revision records and national procedure coding records. Survival modelling was used to estimate POPFF incidence rates, adjusting for potential confounders. Subgroup analyses were performed for patients over 70 years, with non-osteoarthritic indications, and neck of femur fracture. POPFF occurred in 0.6% (5100/809,832) of cases during a median (IQR) follow up of 6.5 (3.9 to 9.6) years. The majority of POPFF were treated with fixation after implantation of a cemented stem. Adjusted patient time incidence rates (PTIR) for POPFF varied by stem design, regardless of cement fixation. Cemented composite beam stems (CB stems) demonstrated the lowest risk of POPFF. Collared cementless stems had an equivalent or lower rate of POPFF versus the current gold standard polished taper slip cemented stem. POPFF account for a quarter of all revisions following primary THA. Cemented CB stems are associated with the lowest POPFF risk. Stem design is strongly associated with POPFF risk, regardless of the presence of cement. Surgeons, policymakers, and patients should consider these findings when recommending femoral implants in those most at risk of POPFF


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 83 - 83
1 Dec 2022
Van Meirhaeghe J Vicente M Leighton R Backstein D Nousiainen M Sanders DW Dehghan N Cullinan C Stone T Schemitsch C Nauth A
Full Access

The management of periprosthetic distal femur fractures is an issue of increasing importance for orthopaedic surgeons. Because of the expanding indications for total knee arthroplasty (TKA) and an aging population with increasingly active lifestyles there has been a corresponding increase in the prevalence of these injuries. The management of these fractures is often complex because of issues with obtaining fixation around implants and dealing with osteopenic bone or compromised bone stock. In addition, these injuries frequently occur in frail, elderly patients, and the early restoration of function and ambulation is critical in these patients. There remains substantial controversy with respect to the optimal treatment of periprosthetic distal femur fractures, with some advocating for Locked Plating (LP), others Retrograde Intramedullary Nailing (RIMN) and finally those who advocate for Distal Femoral Replacement (DFR). The literature comparing these treatments, has been infrequent, and commonly restricted to single-center studies. The purpose of this study was to retrospectively evaluate a large series of operatively treated periprosthetic distal femur fractures from multiple centers and compare treatment strategies. Patients who were treated operatively for a periprosthetic distal femur fracture at 8 centers across North America between 2003 and 2018 were retrospectively identified. Baseline characteristics, surgical details and post-operative clinical outcomes were collected from patients meeting inclusion criteria. Inclusion criteria were patients aged 18 and older, any displaced operatively treated periprosthetic femur fracture and documented 1 year follow-up. Patients with other major lower extremity trauma or ipsilateral total hip replacement were excluded. Patients were divided into 3 groups depending on the type of fixation received: Locked Plating, Retrograde Intramedullary Nailing and Distal Femoral Replacement. Documented clinical follow-up was reviewed at 2 weeks, 3 months, 6 months and 1 year following surgery. Outcome and covariate measures were assessed using basic descriptive statistics. Categorical variables, including the rate of re-operation, were compared across the three treatment groups using Fisher Exact Test. In total, 121 patients (male: 21% / female: 79%) from 8 centers were included in our analysis. Sixty-seven patients were treated with Locked Plating, 15 with Retrograde Intramedullary Nailing, and 39 were treated with Distal Femoral Replacement. At 1 year, 64% of LP patients showed radiographic union compared to 77% in the RIMN group (p=0.747). Between the 3 groups, we did not find any significant differences in ambulation, return to work and complication rates at 6 months and 1 year (Table 1). Reoperation rates at 1 year were 27% in the LP group (17 reoperations), 16% in the DFR group (6 reoperations) and 0% in the RIMN group. These differences were not statistically significant (p=0.058). We evaluated a large multicenter series of operatively treated periprosthetic distal femur fractures in this study. We did not find any statistically significant differences at 1 year between treatment groups in this study. There was a trend towards a lower rate of reoperation in the Retrograde Intramedullary Nailing group that should be evaluated further with prospective studies. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 18 - 18
1 Jun 2023
Hoellwarth J Oomatia A Al Muderis M
Full Access

Introduction. Transtibial osseointegration (TFOI) for amputees has limited but clear literature identifying superior quality of life and mobility versus a socketed prosthesis. Some amputees have knee arthritis that would be relieved by a total knee replacement (TKR). No other group has reported performing a TKR in association with TTOI (TKR+TTOI). We report the outcomes of nine patients who had TKR+TTOI, followed for an average 6.5 years. Materials & Methods. Our osseointegration registry was retrospectively reviewed to identify all patients who had TTOI and who also had TKR, performed at least two years prior. Four patients had TKR first the TTOI, four patients had simultaneous TKR+TTOI, and one patient had 1 OI first then TKR. All constructs were in continuity from hinged TKR to the prosthetic limb. Outcomes were: complications prompting surgical intervention, and changes in daily prosthesis wear hours, Questionnaire for Persons with a Transfemoral Amputation (QTFA), and Short Form 36 (SF36). All patients had clinical follow-up, but two patients did not have complete survey and mobility tests at both time periods. Results. Six (67%) were male, average age 51.2±14.7 years. All primary amputations were performed to manage traumatic injury or its sequelae. No patients died. Five patients (56%) developed infection leading to eventual transfemoral amputation 36.0±15.3 months later, and 1 patient had a single debridement six years after TTOI with no additional surgery in the subsequent two years. All patients who had transfemoral amputation elected for and received transfemoral osseointegration, and no infections occurred, although one patient sustained a periprosthetic fracture which was managed with internal fixation and implant retention and walks independently. The proportion of patients who wore their prosthesis at least 8 hours daily was 5/9=56%, versus 7/9=78% (p=.620). Even after proximal level amputation, the QTFA scores improved versus prior to TKR+TTOI, although not significantly: Global (45.2±20.3 vs 66.7±27.6, p=.179), Problem (39.8±19.8 vs 21.5±16.8, p=.205), Mobility (54.8±28.1 vs 67.7±25.0, p=.356). SF36 changes were also non-significant: Mental (58.6±7.0 vs 46.1±11.0, p=.068), Physical (34.3±6.1 vs 35.2±13.7, p=.904). Conclusions. TKR+TTOI presents a high risk for eventual infection prompting subsequent transfemoral amputation. Although none of these patients died, in general, TKR infection can lead to patient mortality. Given the exceptional benefit to preserving the knee joint to preserve amputee mobility and quality of life, it would be devastating to flatly force transtibial amputees with severe degenerative knee joint pain and unable to use a socket prosthesis to choose between TTOI but a painful knee, or preemptive transfemoral amputation for transfemoral osseointegration. Therefore, TTOI for patients who also request TKR must be considered cautiously. Given that this frequency of infection does not occur in patients who have total hip replacement in association with transfemoral osseointegration, the underlying issue may not be that linked joint replacement with osseointegrated limb replacement is incompatible, but may require further consideration of biological barriers to ascending infection and/or significant changes to implant design, surgical technique, or other yet-uncertain factors


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 19 - 26
1 Jan 2022
Sevaldsen K Schnell Husby O Lian ØB Farran KM Schnell Husby V

Aims. Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. Methods. In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis. Results. Results from mixed model analyses revealed a lower mean retroversion for line-to-line (0.72° (95% confidence interval (CI) 0.38° to 1.07°; p < 0.001), but no significant differences in subsidence between the techniques (-0.15 mm (95% CI -0.53 to 0.227; p = 0.429) at 24 months. Radiolucent lines measuring < 2 mm wide were found in three and five arthroplasties cemented by the standard and line-to-line method, respectively. Conclusion. The cemented Corail stem with a force-closed design seems to settle earlier and better with the line-to-line cementing method, although for subsidence the difference was not significant. However, the lower rate of migration into retroversion may reduce the wear and cement deformation, contributing to good long-term fixation and implant survival. Cite this article: Bone Joint J 2022;104-B(1):19–26


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 154 - 154
1 Nov 2021
Elbahi A Thomas O Dungey M Menon DK
Full Access

Introduction and Objective. When using radiation intraoperatively, a surgeon should aim to maintain the dose as low as reasonably achievable to obtain the diagnostic or therapeutic goal. The UK Health Protection Agency reported mean radiation dose-area-product (DAP) of 4 Gy cm2 for hip procedures. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures. Materials and Methods. We assessed 369 neck of femur fractures between April 2019 and April 2020 in one district general hospital. Fractures were classified as extracapsular or intracapsular and into subtypes as per AO classification. Data was collected on type of fractures, implants used, level of surgeon, duration of surgery and DAP. Types of fractures were subclassified as complex (multifragmentary, subtrochanteric and reverse oblique) or simple. Results. Patients with fractures fixed with DHS, short PFNA, long PFNA and cannulated screws were included. 50% of our patients were fixed with hemiarthroplasty or total hip replacement and were therefore excluded. 184 patients were included in the analysis. There was a significant association of higher DAP with fracture subtype (P=0.001), fracture complexity (P<0.001), if an additional implant was used (P=0.001), if fixation was satisfactory (P=0.002) and the operative time (P<0.001). DAP was higher in PFNA than DHS and greatest in Long PFNA. There was some evidence of association between the level of the surgeon and DAP, although this was not statistically significant (P=0.069) and remained not significant after adjusting for the variables (fracture complexity, fixation or implant used) (p=0.32). Conclusions. Increased radiation in proximal femur fractures is seen in fixation of complex fractures, certain subtypes, the type of implant used and if an additional implant was required. Seniority of surgeon did not result in less radiation exposure even when adjusting for other factors, which is in contrast to other published studies


Bone & Joint Open
Vol. 5, Issue 3 | Pages 236 - 242
22 Mar 2024
Guryel E McEwan J Qureshi AA Robertson A Ahluwalia R

Aims

Ankle fractures are common injuries and the third most common fragility fracture. In all, 40% of ankle fractures in the frail are open and represent a complex clinical scenario, with morbidity and mortality rates similar to hip fracture patients. They have a higher risk of complications, such as wound infections, malunion, hospital-acquired infections, pressure sores, veno-thromboembolic events, and significant sarcopaenia from prolonged bed rest.

Methods

A modified Delphi method was used and a group of experts with a vested interest in best practice were invited from the British Foot and Ankle Society (BOFAS), British Orthopaedic Association (BOA), Orthopaedic Trauma Society (OTS), British Association of Plastic & Reconstructive Surgeons (BAPRAS), British Geriatric Society (BGS), and the British Limb Reconstruction Society (BLRS).


Aims

The primary objective of this study was to compare the five-year tibial component migration and wear between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts of the uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary objectives included clinical outcomes and patient-reported outcome measures (PROMs).

Methods

A double-blinded, randomized study was conducted including 96 TKAs. Tibial component migration and insert wear were measured with radiostereometric analysis (RSA) at three, six, 12, 24, and 60 months postoperatively. PROMS were collected preoperatively and at all follow-up timepoints.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims

A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis.

Methods

Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits.


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 66 - 73
1 May 2024
Chaudhry F Daud A Greenberg A Braunstein D Safir OA Gross AE Kuzyk PR

Aims

Pelvic discontinuity is a challenging acetabular defect without a consensus on surgical management. Cup-cage reconstruction is an increasingly used treatment strategy. The present study evaluated implant survival, clinical and radiological outcomes, and complications associated with the cup-cage construct.

Methods

We included 53 cup-cage construct (51 patients) implants used for hip revision procedures for pelvic discontinuity between January 2003 and January 2022 in this retrospective review. Mean age at surgery was 71.8 years (50.0 to 92.0; SD 10.3), 43/53 (81.1%) were female, and mean follow-up was 6.4 years (0.02 to 20.0; SD 4.6). Patients were implanted with a Trabecular Metal Revision Shell with either a ZCA cage (n = 12) or a TMARS cage (n = 40, all Zimmer Biomet). Pelvic discontinuity was diagnosed on preoperative radiographs and/or intraoperatively. Kaplan-Meier survival analysis was performed, with failure defined as revision of the cup-cage reconstruction.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims

The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery.

Methods

A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series.