Advertisement for orthosearch.org.uk
Results 1 - 20 of 167
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 724 - 731
1 Jun 2019
Bernthal NM Upfill-Brown A Burke ZDC Ishmael CR Hsiue P Hori K Hornicek F Eckardt JJ

Aims. Aseptic loosening is a major cause of failure in cemented endoprosthetic reconstructions. This paper presents the long-term outcomes of a custom-designed cross-pin fixation construct designed to minimize rotational stress and subsequent aseptic loosening in selected patients. The paper will also examine the long-term survivorship and modes of failure when using this technique. Patients and Methods. A review of 658 consecutive, prospectively collected cemented endoprosthetic reconstructions for oncological diagnoses at a single centre between 1980 and 2017 was performed. A total of 51 patients were identified with 56 endoprosthetic implants with cross-pin fixation, 21 of which were implanted following primary resection of tumour. Locations included distal femoral (n = 36), proximal femoral (n = 7), intercalary (n = 6), proximal humeral (n = 3), proximal tibial (n = 3), and distal humeral (n = 1). Results. The median follow-up was 132 months (interquartile range (IQR) 44 to 189). In all, 20 stems required revision: eight for infection, five for structural failure, five for aseptic loosening, and two for tumour progression. Mechanical survivorship at five, ten, and 15 years was 84%, 78%, and 78%, respectively. Mechanical failure rate varied by location, with no mechanical failures of proximal femoral constructs and distal femoral survivorship of 82%, 77%, and 77% at five, ten, and 15 years. The survivorship of primary constructs at five years was 74%, with no failure after 40 months, while the survivorship for revision constructs was 89%, 80%, and 80% at five, ten, and 15 years. . Conclusion. The rate of mechanical survivorship in our series is similar to those reported for other methods of reconstruction for short diaphyseal segments, such as compressive osseointegration. The mechanical failure rate differed by location, while there was no substantial difference in long-term survival between primary and revision reconstructions. Overall, custom cross-pin fixation is a viable option for endoprosthetic reconstruction of short metaphyseal segments with an acceptable rate of mechanical failure. Cite this article: Bone Joint J 2019;101-B:724–731


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 534 - 539
1 Apr 2005
Cobb JP Ashwood N Robbins G Witt JD Unwin PS Blunn G

Massive endoprostheses using a cemented intramedullary stem are widely used to allow early resumption of activity after surgery for tumours. The survival of the prosthesis varies with the anatomical site, the type of prosthesis and the mode of fixation. Revision surgery is required in many cases because of aseptic loosening. Insertion of a second cemented endoprosthesis may be difficult because of the poor quality of the remaining bone, and loosening recurs quickly. We describe a series of 14 patients with triplate fixation in difficult revision or joint-sparing tumour surgery with a minimum follow-up of four years. The triplate design incorporated well within a remodelled cortex to achieve osseomechanical integration with all patients regaining their original level of function within five months. Our preliminary results suggest that this technique may provide an easy, biomechanically friendly alternative to insertion of a further device with an intramedullary stem, which has a shorter lifespan in revision or joint-sparing tumour surgery. A short segment of bone remaining after resection of a tumour will not accept an intramedullary stem, but may be soundly fixed using this method


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 924 - 928
1 Jul 2008
Tsuchiya H Shirai T Morsy AF Sakayama K Wada T Kusuzaki K Sugita T Tomita K

We studied the safety of external fixation during post-operative chemotherapy in 28 patients who had undergone distraction osteogenesis (17, group A) or vascularised fibular grafting (11, group B) after resection of a tumour. Four cycles of multi-agent post-operative chemotherapy were administered over a mean period of 14 weeks (6 to 27). The mean duration of external fixation for all patients was 350 days (91 to 828). In total 204 wires and 240 half pins were used. During the period of post-operative chemotherapy, 14 patients (11 in group A, 3 in group B) developed wire- and pin-track infection. A total of ten wires (4.9%) and 11 half pins (4.6%) became infected. Seven of the ten infected wires were in periarticular locations. External fixation during post-operative chemotherapy was used safely and successfully for fixation of a vascularised fibular graft and distraction osteogenesis in 27 of 28 patients. Post-operative chemotherapy for malignant bone tumours did not adversely affect the ability to achieve union or cause hypertrophy of the vascularised fibular graft and had a minimal effect on distraction osteogenesis. Only one patient developed osteomyelitis which required further surgery


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1144 - 1148
1 Aug 2013
Sternheim A Saidi K Lochab J O’Donnell PW Eward WC Griffin A Wunder JS Ferguson P

We investigated the clinical outcome of internal fixation for pathological fracture of the femur after primary excision of a soft-tissue sarcoma that had been treated with adjuvant radiotherapy. A review of our database identified 22 radiation-induced fractures of the femur in 22 patients (seven men, 15 women). We noted the mechanism of injury, fracture pattern and any complications after internal fixation, including nonunion, hardware failure, secondary fracture or deep infection. The mean age of the patients at primary excision of the tumour was 58.3 years (39 to 86). The mean time from primary excision to fracture was 73.2 months (2 to 195). The mean follow-up after fracture fixation was 65.9 months (12 to 205). Complications occurred in 19 patients (86%). Nonunion developed in 18 patients (82%), of whom 11 had a radiological nonunion at 12 months, five a nonunion and hardware failure and two an infected nonunion. One patient developed a second radiation-associated fracture of the femur after internal fixation and union of the initial fracture. A total of 13 patients (59%) underwent 24 revision operations. Internal fixation of a pathological fracture of the femur after radiotherapy for a soft-tissue sarcoma has an extremely high rate of complication and requires specialist attention. Cite this article: Bone Joint J 2013;95-B:1144–8


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated. The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221). The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°). At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 973 - 978
1 Jul 2017
Gupta S Kafchinski LA Gundle KR Saidi K Griffin AM Wunder JS Ferguson PC

Aims. Intercalary allografts following resection of a primary diaphyseal tumour have high rates of complications and failures. At our institution intercalary allografts are augmented with intramedullary cement and fixed using compression plating. Our aim was to evaluate their long-term outcomes. Patients and Methods. A total of 46 patients underwent reconstruction with an intercalary allograft between 1989 and 2014. The patients had a mean age of 32.8 years (14 to 77). The most common diagnoses were osteosarcoma (n = 16) and chondrosarcoma (n = 9). The location of the tumours was in the femur in 21, the tibia in 16 and the humerus in nine. Function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and the Toronto Extremity Salvage Score (TESS). The survival of the graft and the overall survival were assessed using the Kaplan-Meier method. Results. The median follow-up was 92 months (4 to 288). The mean MSTS 87 score was 29.1 (19 to 35), the mean MSTS 93 score was 82.2 (50 to 100) and the mean TESS score was 81.2 (43 to 100). Overall survival of the allograft was 84.8%. A total of 15 patients (33%) had a complication. Five allografts were revised for complications and one for local recurrence. Conclusion. Intercalary allografts augmented with intramedullary cement and compression plate fixation provide a reliable and durable method of reconstruction after the excision of a primary diaphyseal bone tumour, with high levels of function and satisfaction. . Cite this article: Bone Joint J 2017;99-B:973–8


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1144 - 1150
1 Sep 2019
Tsuda Y Fujiwara T Sree D Stevenson JD Evans S Abudu A

Aims

The aim of this study was to report the results of custom-made endoprostheses with extracortical plates plus or minus a short, intramedullary stem aimed at preserving the physis after resection of bone sarcomas in children.

Patients and Methods

Between 2007 and 2017, 18 children aged less than 16 years old who underwent resection of bone sarcomas, leaving ≤ 5 cm of bone from the physis, and reconstruction with a custom-made endoprosthesis were reviewed. Median follow-up was 67 months (interquartile range 45 to 91). The tumours were located in the femur in 11 patients, proximal humerus in six, and proximal tibia in one.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1093 - 1097
1 Aug 2011
Weiss KR Bhumbra R Biau DJ Griffin AM Deheshi B Wunder JS Ferguson PC

Pathological fractures of the humerus are associated with pain, morbidity, loss of function and a diminished quality of life. We report our experience of stabilising these fractures using polymethylmethacrylate and non-locking plates. We undertook a retrospective review over 20 years of patients treated at a tertiary musculoskeletal oncology centre. Those who had undergone surgery for an impending or completed pathological humeral fracture with a diagnosis of metastatic disease or myeloma were identified from our database. There were 63 patients (43 men, 20 women) in the series with a mean age of 63 years (39 to 87). All had undergone intralesional curettage of the tumour followed by fixation with intramedullary polymethylmethacrylate and plating. Complications occurred in 14 patients (22.2%) and seven (11.1%) required re-operation. At the latest follow-up, 47 patients (74.6%) were deceased and 16 (25.4%) were living with a mean follow-up of 75 months (1 to 184). A total of 54 (86%) patients had no or mild pain and 50 (80%) required no or minimal assistance with activities of daily living. Of the 16 living patients none had pain and all could perform activities of daily living without assistance. Intralesional resection of the tumour, filling of the cavity with cement, and plate stabilisation of the pathological fracture gives immediate rigidity and allows an early return of function without the need for bony union. The patient’s local disease burden is reduced, which may alleviate tumour-related pain and slow the progression of the disease. The cemented-plate technique provides a reliable option for the treatment of pathological fractures of the humerus


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee. In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1084 - 1087
1 Aug 2007
Bruns J Delling G Gruber H Lohmann CH Habermann CR

We reviewed 25 patients in whom a MUTARS megaprosthesis with a conical fluted stem had been implanted. There were three types of stem: a standard stem was used in 17 cases (three in the proximal femur, nine in the distal femur and five proximal tibia), a custom-made proximal femoral stem in four cases and a custom-made distal femoral stem in four cases. The mean age of the patients was 40.1 years (17 to 70) and the mean follow-up was for 2.5 years (0.9 to 7.4).

At follow-up two patients had died from their disease: one was alive with disease and 22 were disease-free. One of 23 prostheses had been removed for infection and another revised to a cemented stem. The mean Musculoskeletal Tumor Society score was 24.9 (12 to 30) and the mean Karnofsky index was 82% (60% to 100%).

There was no radiological evidence of loosening or subsidence. Stem stress shielding was seen in 11 patients and was marked in five of these.

There were five complications, rupture of the extensor mechanism of the knee after extra-articular resection in two patients, deep venous thrombosis in one, septic loosening in one, and dislocation of the hip in one.

The survival rate after seven years was 87% (95% confidence interval (CI) 83 to 91) for the patients and 95% (95% CI 91 to 99) for the megaprosthesis. A longer follow-up is needed to confirm these encouraging results.


Bone & Joint Open
Vol. 3, Issue 8 | Pages 648 - 655
1 Aug 2022
Yeung CM Bhashyam AR Groot OQ Merchan N Newman ET Raskin KA Lozano-Calderón SA

Aims. Due to their radiolucency and favourable mechanical properties, carbon fibre nails may be a preferable alternative to titanium nails for oncology patients. We aim to compare the surgical characteristics and short-term results of patients who underwent intramedullary fixation with either a titanium or carbon fibre nail for pathological long-bone fracture. Methods. This single tertiary-institutional, retrospectively matched case-control study included 72 patients who underwent prophylactic or therapeutic fixation for pathological fracture of the humerus, femur, or tibia with either a titanium (control group, n = 36) or carbon fibre (case group, n = 36) intramedullary nail between 2016 to 2020. Patients were excluded if intramedullary fixation was combined with any other surgical procedure/fixation method. Outcomes included operating time, blood loss, fluoroscopic time, and complications. Fisher’s exact test and Mann-Whitney U test were used for categorical and continuous outcomes, respectively. Results. Patients receiving carbon nails as compared to those receiving titanium nails had higher blood loss (median 150 ml (interquartile range (IQR) 100 to 250) vs 100 ml (IQR 50 to 150); p = 0.042) and longer fluoroscopic time (median 150 seconds (IQR 114 to 182) vs 94 seconds (IQR 58 to 124); p = 0.001). Implant complications occurred in seven patients (19%) in the titanium group versus one patient (3%) in the carbon fibre group (p = 0.055). There were no notable differences between groups with regard to operating time, surgical wound infection, or survival. Conclusion. This pilot study demonstrates a non-inferior surgical and short-term clinical profile supporting further consideration of carbon fibre nails for pathological fracture fixation in orthopaedic oncology patients. Given enhanced accommodation of imaging methods important for oncological surveillance and radiation therapy planning, as well as high tolerances to fatigue stress, carbon fibre implants possess important oncological advantages over titanium implants that merit further prospective investigation. Level of evidence: III, Retrospective study. Cite this article: Bone Jt Open 2022;3(8):648–655


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1405 - 1413
1 Aug 2021
Ogura K Fujiwara T Morris CD Boland PJ Healey JH

Aims. Rotating-hinge knee prostheses are commonly used to reconstruct the distal femur after resection of a tumour, despite the projected long-term burden of reoperation due to complications. Few studies have examined the factors that influence their failure and none, to our knowledge, have used competing risk models to do so. The purpose of this study was to determine the risk factors for failure of a rotating-hinge knee distal femoral arthroplasty using the Fine-Gray competing risk model. Methods. We retrospectively reviewed 209 consecutive patients who, between 1991 and 2016, had undergone resection of the distal femur for tumour and reconstruction using a rotating-hinge knee prosthesis. The study endpoint was failure of the prosthesis, defined as removal of the femoral component, the tibial component, or the bone-implant fixation; major revision (exchange of the femoral component, tibial component, or the bone-implant fixation); or amputation. Results. Multivariate Fine-Gray regression analyses revealed different hazards for each Henderson failure mode: percentage of femoral resection (p = 0.001) and extent of quadriceps muscle resection (p = 0.005) for overall prosthetic failure; extent of quadriceps muscle resection (p = 0.002) and fixation of femoral component (p = 0.011) for type 2 failure (aseptic loosening); age (p = 0.009) and percentage of femoral resection (p = 0.019) for type 3 failure (mechanical failure); and type of joint resection (p = 0.037) for type 4 (infection) were independent predictors. A bone stem ratio of > 2.5 reliably predicted aseptic loosening. Conclusion. We identified independent risk factors for overall and cause-specific prosthetic failure after rotating-hinge knee distal femoral arthroplasty using a competing risk Fine-Gray model. A bone stem ratio > 2.5 reliably predicts aseptic loosening. An accurate knowledge of the risks of distal femoral arthroplasty after resection for tumour assists surgical planning and managing patient expectations. Cite this article: Bone Joint J 2021;103-B(8):1405–1413


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 398 - 404
1 Feb 2021
Christ AB Fujiwara T Yakoub MA Healey JH

Aims. We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur. Methods. A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory status. ,. and Musculoskeletal Tumor Society (MSTS) score were recorded. The percentage of proximal femur remaining was calculated from follow-up radiographs. Results. All 14 at-risk native hip joints were preserved at a mean final follow-up of 6.0 years (SD 3.7), despite a short residual femur, often after proximal osteotomies through the lesser trochanter. Overall, 13 of 14 stems had long-term successful fixation. Eight patients required no reoperation. Three patients required reoperation due to implant-related issues, and three patients required reoperation for wound healing problems or infection. There were no dislocations or fractures. At final follow-up the mean MSTS score was 24.9 (SD 4.1). Nine patients required no ambulation aids, and only one had a Trendelenburg gait. Conclusion. This interlocking, reconstruction-mode stem-sideplate reliably preserves native hip joint anatomy and function after large femoral resection with a short remaining proximal femur, both in the primary and revision setting. This is particularly important for preventing or delaying total femoral arthroplasty in young patients after oncological reconstruction. Hip abductor strength and function could be maintained by this method, and the risk of dislocation eliminated. The success of this technique in this modest series should be verified in a larger collaborative study and will be of interest to revision surgeons and oncologists. Cite this article: Bone Joint J 2021;103-B(2):398–404


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1414 - 1420
1 Aug 2021
Wellings EP Houdek MT Owen AR Bakri K Yaszemski MJ Sim FH Moran SL Rose PS

Aims. Orthopaedic and reconstructive surgeons are faced with large defects after the resection of malignant tumours of the sacrum. Spinopelvic reconstruction is advocated for resections above the level of the S1 neural foramina or involving the sacroiliac joint. Fixation may be augmented with either free vascularized fibular flaps (FVFs) or allograft fibular struts (AFSs) in a cathedral style. However, there are no studies comparing these reconstructive techniques. Methods. We reviewed 44 patients (23 female, 21 male) with a mean age of 40 years (SD 17), who underwent en bloc sacrectomy for a malignant tumour of the sacrum with a reconstruction using a total (n = 20), subtotal (n = 2), or hemicathedral (n = 25) technique. The reconstructions were supplemented with a FVF in 25 patients (57%) and an AFS in 19 patients (43%). The mean length of the strut graft was 13 cm (SD 4). The mean follow-up was seven years (SD 5). Results. There was no difference in the mean age, sex, length of graft, size of the tumour, or the proportion of patients with a history of treatment with radiotherapy in the two groups. Reconstruction using an AFS was associated with nonunion (odds ratio 7.464 (95% confidence interval (CI) 1.77 to 31.36); p = 0.007) and a significantly longer mean time to union (12 months (SD 3) vs eight (SD 3); p = 0.001) compared with a reconstruction using a FVF. Revision for a pseudoarthrosis was more likely to occur in the AFS group compared with the FVF group (hazard ratio 3.84 (95% CI 0.74 to 19.80); p = 0.109); however, this was not significant. Following the procedure, 32 patients (78%) were mobile with a mean Musculoskeletal Tumor Society Score 93 of 52% (SD 24%). There was a significantly higher mean score in patients reconstructed with a FVF compared with an AFS (62% vs 42%; p = 0.003). Conclusion. Supplementation of spinopelvic reconstruction with a FVF was associated with a shorter time to union and a trend towards a reduced risk of hardware failure secondary to nonunion compared with reconstruction using an AFS. Spinopelvic fixation supplemented with a FVF is our preferred technique for reconstruction following resection of a sacral tumour. Cite this article: Bone Joint J 2021;103-B(8):1414–1420


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 1000 - 1007
1 Sep 2024
Gong T Lu M Sheng H Li Z Zhou Y Luo Y Min L Tu C

Aims

Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes.

Methods

This study involved patients who underwent implantation of an uncemented distal femoral endoprosthesis with a short and curved stem between 2014 and 2019. Functional outcomes were assessed using the 1993 version of the Musculoskeletal Tumour Society (MSTS-93) score. Additionally, we quantified five types of complications and assessed osseointegration radiologically. The survivorship of the endoprosthesis was evaluated according to two endpoints. A total of 134 patients with a median age of 26 years (IQR 16 to 41) were included in our study. The median follow-up time was 61 months (IQR 56 to 76), and the median functional MSTS-93 was 83% (IQR 73 to 91) postoperatively.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 424 - 431
5 Jun 2023
Christ AB Piple AS Gettleman BS Duong A Chen M Wang JC Heckmann ND Menendez L

Aims

The modern prevalence of primary tumours causing metastatic bone disease is ill-defined in the oncological literature. Therefore, the purpose of this study is to identify the prevalence of primary tumours in the setting of metastatic bone disease, as well as reported rates of pathological fracture, postoperative complications, 90-day mortality, and 360-day mortality for each primary tumour subtype.

Methods

The Premier Healthcare Database was queried to identify all patients who were diagnosed with metastatic bone disease from January 2015 to December 2020. The prevalence of all primary tumour subtypes was tabulated. Rates of long bone pathological fracture, 90-day mortality, and 360-day mortality following surgical treatment of pathological fracture were assessed for each primary tumour subtype. Patient characteristics and postoperative outcomes were analyzed based upon whether patients had impending fractures treated prophylactically versus treated completed fractures.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1115 - 1122
1 Oct 2023
Archer JE Chauhan GS Dewan V Osman K Thomson C Nandra RS Ashford RU Cool P Stevenson J

Aims

Most patients with advanced malignancy suffer bone metastases, which pose a significant challenge to orthopaedic services and burden to the health economy. This study aimed to assess adherence to the British Orthopaedic Oncology Society (BOOS)/British Orthopaedic Association (BOA) guidelines on patients with metastatic bone disease (MBD) in the UK.

Methods

A prospective, multicentre, national collaborative audit was designed and delivered by a trainee-led collaborative group. Data were collected over three months (1 April 2021 to 30 June 2021) for all patients presenting with MBD. A data collection tool allowed investigators at each hospital to compare practice against guidelines. Data were collated and analyzed centrally to quantify compliance from 84 hospitals in the UK for a total of 1,137 patients who were eligible for inclusion.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 317 - 323
18 Apr 2024
Zhu X Hu J Lin J Song G Xu H Lu J Tang Q Wang J

Aims

The aim of this study was to investigate the safety and efficacy of 3D-printed modular prostheses in patients who underwent joint-sparing limb salvage surgery (JSLSS) for malignant femoral diaphyseal bone tumours.

Methods

We retrospectively reviewed 17 patients (13 males and four females) with femoral diaphyseal tumours who underwent JSLSS in our hospital.


Bone & Joint Open
Vol. 5, Issue 9 | Pages 749 - 757
12 Sep 2024
Hajialiloo Sami S Kargar Shooroki K Ammar W Nahvizadeh S Mohammadi M Dehghani R Toloue B

Aims

The ulna is an extremely rare location for primary bone tumours of the elbow in paediatrics. Although several reconstruction options are available, the optimal reconstruction method is still unknown due to the rarity of proximal ulna tumours. In this study, we report the outcomes of osteoarticular ulna allograft for the reconstruction of proximal ulna tumours.

Methods

Medical profiles of 13 patients, who between March 2004 and November 2021 underwent osteoarticular ulna allograft reconstruction after the resection of the proximal ulna tumour, were retrospectively reviewed. The outcomes were measured clinically by the assessment of elbow range of motion (ROM), stability, and function, and radiologically by the assessment of allograft-host junction union, recurrence, and joint degeneration. The elbow function was assessed objectively by the Musculoskeletal Tumor Society (MSTS) score and subjectively by the Toronto Extremity Salvage Score (TESS) and Mayo Elbow Performance Score (MEPS) questionnaire.


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims

Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children.

Methods

A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score.