Advertisement for orthosearch.org.uk
Results 1 - 20 of 286
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 846 - 850
1 Jun 2016
Hoskins W Sheehy R Edwards ER Hau RC Bucknill A Parsons N Griffin XL

Aims. Fractures of the distal femur are an important cause of morbidity. Their optimal management remains controversial. Contemporary implants include angular-stable anatomical locking plates and locked intramedullary nails (IMNs). We compared the long-term patient-reported functional outcome of fixation of fractures of the distal femur using these two methods of treatment. Patients and Methods. A total of 297 patients were retrospectively identified from a State-wide trauma registry in Australia: 195 had been treated with a locking plate and 102 with an IMN. Baseline characteristics of the patients and their fractures were recorded. Health-related quality-of-life, functional and radiographic outcomes were compared using mixed effects regression models at six months and one year. Results. There was a clinically relevant and significant difference in quality-of-life at six months in favour of fixation with an IMN (mean difference in EuroQol-5 Dimensions Score (EQ-5D) = 0.12; 95% CI 0.02 to 0.22; p = 0.025). There was weak evidence that this trend continued to one year (mean difference EQ-5D = 0.09; 95% CI -0.01 to 0.19; p = 0.073). There was a significant although very small reduction in angular deformity using an IMN (mean difference -1.02; 95% CI -1.99 to -0.06; p = 0.073). There was no evidence that there was a difference in any other outcomes at any time point. Take home message: IMN may be a superior treatment compared with anatomical locking plates for fractures of the distal femur. These findings are concordant with other data from pilot randomised studies which favour treatment of these fractures with an IMN. This study strongly supports the need for a definitive randomised trial. Cite this article: Bone Joint J 2016;98-B:846–50


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 842 - 846
1 Jun 2015
Bennett PM Sargeant ID Myatt RW Penn-Barwell JG

This is a retrospective study of survivors of recent conflicts with an open fracture of the femur. We analysed the records of 48 patients (48 fractures) and assessed the outcome. The median follow up for 47 patients (98%) was 37 months (interquartile range 19 to 53); 31 (66%) achieved union; 16 (34%) had a revision procedure, two of which were transfemoral amputation (4%). The New Injury Severity Score, the method of fixation, infection and the requirement for soft-tissue cover were not associated with a poor outcome. The degree of bone loss was strongly associated with a poor outcome (p = 0.00204). A total of four patients developed an infection; two with S. aureus, one with E. coli and one with A. baumannii. This study shows that, compared with historical experience, outcomes after open fractures of the femur sustained on the battlefield are good, with no mortality and low rates of infection and late amputation. The degree of bone loss is closely associated with a poor outcome. Cite this article: Bone Joint J 2015;97-B:842–6


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1378 - 1384
1 Oct 2014
Weiser L Korecki MA Sellenschloh K Fensky F Püschel K Morlock MM Rueger JM Lehmann W

It is becoming increasingly common for a patient to have ipsilateral hip and knee replacements. The inter-prosthetic (IP) distance, the distance between the tips of hip and knee prostheses, has been thought to be associated with an increased risk of IP fracture. Small gap distances are generally assumed to act as stress risers, although there is no real biomechanical evidence to support this. The purpose of this study was to evaluate the influence of IP distance, cortical thickness and bone mineral density on the likelihood of an IP femoral fracture. A total of 18 human femur specimens were randomised into three groups by bone density and cortical thickness. For each group, a defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing the appropriate lengths of component. The maximum fracture strength was determined using a four-point bending test. The fracture force of all three groups was similar (p = 0.498). There was a highly significant correlation between the cortical area and the fracture strength (r = 0.804, p <  0.001), whereas bone density showed no influence. This study suggests that the IP distance has little influence on fracture strength in IP femoral fractures: the thickness of the cortex seems to be the decisive factor. Cite this article: Bone Joint J 2014;96-B:1378–84


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 9 - 9
8 Feb 2024
Hall AJ Clement ND Farrow L Kennedy JW Harding T Duckworth AD Maclullich AMJ Walmsley P
Full Access

Periprosthetic femur fracture (PPF) are heterogeneous, complex, and thought to be increasingly prevalent. The aims were to evaluate PPF prevalence, casemix, management, and outcomes.

This nationwide study included all PPF patients aged >50 years from 16 Scottish hospitals in 2019. Variables included: demographics; implant and fracture factors; management factors, and outcomes.

There were 332 patients, mean age 79.5 years, and 220/332 (66.3%) were female. One-third (37.3%) were ASA1-2 and two-thirds (62.3%) were ASA3+, 91.0% were from home/sheltered housing, and median Clinical Frailty Score was 4.0 (IQR 3.0). Acute medical issues featured in 87/332 (26.2%) and 19/332 (5.7%) had associated injuries. There were 251/332 (75.6%) associated with a proximal femoral implant, of which 232/251 (92.4%) were arthroplasty devices (194/251 [77.3%] total hip, 35/251 [13.9%] hemiarthroplasty, 3/251 [1.2%] resurfacing). There were 81/332 (24.4%) associated with a distal femoral implant (76/81 [93.8%] were total knee arthroplasties). In 38/332 (11.4%) there were implants proximally and distally. Most patients (268/332; 80.7%) were treated surgically, with 174/268 (64.9%) requiring fixation only and 104/268 (38.8%) requiring an arthroplasty or combined solution. Median time to theatre was longer for arthroplasty versus fixation procedures (120 vs 46 hours), and those requiring inter-hospital transfer waited longer (94 vs 48 hours).

Barriers to investigating PPF include varied classification, coding challenges, and limitations of existing registries. This is the first study to examine a national PPF cohort and presents important data to guide service design and research. Additional findings relating to fracture patterns, implant types, surgeon skill-mix, and outcomes are reported herein.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims. Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity. Methods. A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature. Results. Quantitative MRI revealed a mean reduction of 21.2% (SD 1.3%) of arterial contribution in the lateral plating group and 25.4% (SD 3.2%) in the dual plating group (p = 0.051); representing a mean decrease in arterial contribution of 4.2%. The only significant difference found between both experimental groups was regionally, at the lateral aspect of the distal femur with a mean drop in arterial contribution in the lateral plating group of 18.9% (SD 2.6%) versus 24.0% (SD 3.2%) in the dual plating group (p = 0.048), representing a mean decrease in arterial contribution of 5.1%. Gross dissection revealed complete destruction of periosteal vessels underneath either medial or lateral plates in both groups. The network of genicular branches contributing to the posterior and distal femoral condyles was preserved in all specimens. A medial vascular pedicle was found dividing from the superficial femoral artery at a mean 12.7 cm (SD 1.7) proximal to the medial epicondyle and was undisrupted in the dual plating group. Conclusion. Lateral locking-plate application resulted in mean 21.2% reduction in distal femur vascularity. Addition of medial plates did not further markedly decrease vascularity. As such, the majority of the vascular insult occurred with lateral plating alone. Supplemental medially based fixation did not lead to marked devascularization of the distal femur, and should therefore be considered in the setting of comminution and poor bone stock in distal femoral fractures. Further clinical research is required to confirm the results of this study. Cite this article: Bone Joint J 2020;102-B(4):530–538


Bone & Joint Research
Vol. 6, Issue 3 | Pages 144 - 153
1 Mar 2017
Kharwadkar N Mayne B Lawrence JE Khanduja V

Objectives. Bisphosphonates are widely used as first-line treatment for primary and secondary prevention of fragility fractures. Whilst they have proved effective in this role, there is growing concern over their long-term use, with much evidence linking bisphosphonate-related suppression of bone remodelling to an increased risk of atypical subtrochanteric fractures of the femur (AFFs). The objective of this article is to review this evidence, while presenting the current available strategies for the management of AFFs. Methods. We present an evaluation of current literature relating to the pathogenesis and treatment of AFFs in the context of bisphosphonate use. Results. Six broad themes relating to the pathogenesis and management of bisphosphonate-related AFFs are presented. The key themes in fracture pathogenesis are: bone microdamage accumulation; altered bone mineralisation and altered collagen formation. The key themes in fracture management are: medical therapy and surgical therapy. In addition, primary prevention strategies for AFFs are discussed. Conclusions. This article presents current knowledge about the relationship between bisphosphonates and the development of AFFs, and highlights key areas for future research. In particular, studies aimed at identifying at-risk subpopulations and organising surveillance for those on long-term therapy will be crucial in both increasing our understanding of the condition, and improving population outcomes. Cite this article: N. Kharwadkar, B. Mayne, J. E. Lawrence, V. Khanduja. Bisphosphonates and atypical subtrochanteric fractures of the femur. Bone Joint Res 2017;6:144–153. DOI: 10.1302/2046-3758.63.BJR-2016-0125.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1385 - 1390
1 Oct 2005
Niva MH Kiuru MJ Haataja R Pihlajamäki HK

The purpose of this study was to describe the anatomical distribution and incidence of fatigue injuries of the femur in physically-active young adults, based upon MRI studies. During a period of 70 months, 1857 patients with exercise-induced pain in the femur underwent MRI of the pelvis, hips, femora, and/or knees. Of these, 170 patients had a total of 185 fatigue injuries, giving an incidence of 199 per 100 000 person-years. Bilateral injuries occurred in 9% of patients. The three most common sites affected were the femoral neck (50%), the condylar area (24%) and the proximal shaft (18%). A fatigue reaction was seen in 57%, and a fracture line in 22%. There was a statistical correlation between the severity of the fatigue injury and the duration of pain (p = 0.001). The location of the pain was normally at the site of the fatigue injury. Fatigue injuries of the femur appear to be relatively common in physically-active patients


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1082 - 1087
1 Aug 2020
Yiğit Ş Arslan H Akar MS Şahin MA

Aims

Osteopetrosis (OP) is a rare hereditary disease that causes reduced bone resorption and increased bone density as a result of osteoclastic function defect. Our aim is to review the difficulties, mid-term follow-up results, and literature encountered during the treatment of OP.

Methods

This is a retrospective and observational study containing data from nine patients with a mean age of 14.1 years (9 to 25; three female, six male) with OP who were treated in our hospital between April 2008 and October 2018 with 20 surgical procedures due to 17 different fractures. Patient data included age, sex, operating time, length of stay, genetic type of the disease, previous surgery, fractures, complications, and comorbidity.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 108 - 112
1 Jan 2009
Chandrasekar CR Grimer RJ Carter SR Tillman RM Abudu A Buckley L

Endoprosthetic replacement of the proximal femur may be required to treat primary bone tumours or destructive metastases either with impending or established pathological fracture. Modular prostheses are available off the shelf and can be adapted to most reconstructive situations for this purpose. We have assessed the clinical and functional outcome of using the METS (Stanmore Implants Worldwide) modular tumour prosthesis to reconstruct the proximal femur in 100 consecutive patients between 2001 and 2006. We compared the results with the published series for patients managed with modular and custom-made endoprosthetic replacements for the same conditions. There were 52 males and 48 females with a mean age of 56.3 years (16 to 84) and a mean follow-up of 24.6 months (0 to 60). In 65 patients the procedure was undertaken for metastases, in 25 for a primary bone tumour, and in ten for other malignant conditions. A total of 46 patients presented with a pathological fracture, and 19 presented with failed fixation of a previous pathological fracture. The overall patient survival was 63.6% at one year and 23.1% at five years, and was significantly better for patients with a primary bone tumour than for those with metastatic tumour (82.3% vs 53.3%, respectively at one year (p = 0.003)). There were six early dislocations of which five could be treated by closed reduction. No patient needed revision surgery for dislocation. Revision surgery was required by six (6%) patients, five for pain caused by acetabular wear and one for tumour progression. Amputation was needed in four patients for local recurrence or infection. The estimated five-year implant survival with revision as the endpoint was 90.7%. The mean Toronto Extremity Salvage score was 61% (51% to 95%). The implant survival and complications resulting from the use of the modular system were comparable to the published series of both custom-made and other modular proximal femoral implants. We conclude that at intermediate follow-up the modular tumour prosthesis for proximal femur replacement provides versatility, a low incidence of implant-related complications and acceptable function for patients with metastatic tumours, pathological fractures and failed fixation of the proximal femur. It also functions as well as a custom-made endoprosthetic replacement


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 394 - 394
1 Sep 2012
Stoeckl B
Full Access

Introduction. Total femur implantation is a rare and challenging procedure in final revision surgery of hip and knee arthroplasties. Reports of this operation technique are even rare in literature. In this study we retrospectively analyse our patients with total femur implants. Material and Methods. Between October 2002 and February 2009 we implanted 27 total femurs in hip and knee revision surgery cases. We used the modular prosthesis system–Megasystem C® by Waldemar Link–in all cases. Our 22 female and 5 male patients had a mean age of 76 years (range 45–88). Indications for the procedure were loosening of megaprosthesis of the hip in 12 cases; 2 with massive distal migration, 1 with penetration into the knee joint and 1 after two step revision procedure. In 13 cases a periprosthetic indicated a total femur implanatation due to massive bone loss; 1 breakage of a long femoral stem, 5 fracture of osteosynthesis materials, 3 after prosthesis revisions and 1 pseudoarhrosis of femur and tibia after knee arthroplasty. We analysed perioperative complications, clinical status and result and further revision within follow up time. Results. We were able to examine 16 patients at follow up time. Eight patients were lost to follow up and 2 have been died; 1 after fulminant pulmonal embolia after operation and 1 four years postoperatively. One total femur had to be exchanged due to infection after 1 year. Perioperative complications occurred as follows: 1 massive blood transfusion, 1 peroneal palsy, 1 ulcus ventriculis bleeding, 1 thrombosis of vena suclavia and vena jugularis, 1 sigmaresection due to diverticulosis, 1 luxations of the hip, and 2 wound necrosis. In 3 caese a revision operation swas performed; 1multiple luxtion of the hip and due to infection of the total femur implant. The range of motion of the hip was 85 degrees (range 30–90) and knee 92 degrees (range 30–110). In nearly all cases we found a lengthening of the revised limb. The general outcome of the patients was. Ten patient were very satisfied, 2 statisfied and 2 fair due to pain persistence. Two patient were mobile with one crutch, 3 used two crutches and one was able to walk with a rollator. One patient was unable to walk due to diplegia after spine fracture. Conclusion. Total femur procedure in final revision arthroplasty has a high potential of perioperative risks but has shown good clinical and mobility results in our patient group. With the Megasystem C® by Link we had a save and good performance while operation of this difficult patient group


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 16 - 16
1 May 2015
Lowery K Dearden P Sherman K Mahadevan V Sharma H
Full Access

Background:. Septic arthritis following intra-capsular penetration of the knee by external fixation devices is a complication of traction/fixation devices. This study aimed to demonstrate the capsular attachments and reflections of the distal femur to determine safe placements of wires. Methods:. The attachments of the capsule to the distal femur were measured in cadaveric knees. Medially and laterally measurements were expressed as percentages related to the maximal AP diameter of the distal femur. Results:. Mean distance of the anterior attachment was 79.5mm (Range 48.1–120.7mm). The medial capsular reflections were attached an average of 57% back from the anterior edge (Range 41–74%). Laterally the capsular reflections were attached an average of 48% from the anterior reference point (Range 33–57%). Discussion:. Capsular reflections varied. Medially the capsule attachment was up to 74% of diameter of distal femur at the level of the adductor tubercle. Therefore, the insertion of distal femoral traction pins or similar should be placed proximal to the adductor tubercle and no further than 25% of the distance to the anterior cortex. Care is needed to ensure pins do not travel to exit too anteriorly on the lateral side as capsular attachments were found to be up to a distance 48% of the diameter of the femur from anterior reference point


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 92 - 92
1 Apr 2013
Jung S Park CH Lee JH
Full Access

Introduction. The proximal femur fracture in children is rare. Furthermore osteoporotic fracture associated with bone tumor make it difficult to decide the proper management method. The treatment plan should include both the treatment of the fracture and management of the condition responsible for the fracture. However, the reported literatures are rare and vary. Hypothesis. We identified the results of treatment associated with pathologic fracture of proximal femur in children. Material and Method. We retrospectively reviewed 56 patients who had fracture associated with benign bone femur between May 25th, 1995 and Jan. 14th, 2012. The patients’ mean age was 11.7(2–20) years old and follow-up duration was 55.3(5–132) months. Results. Fifty-six children with pathologic proximal femur fracture due to benign tumor were treated by various methods. Surgery consisted with combination of curettage, graft and internal fixation. We had 13(23%) complication. 6(11%) of them was related with fracture and 7(12%) of them was related with tumor. In six, malunion and shortening due to varus deformity developed after follow-up. In seven, recurrence was treated by curettage and internal fixation. There is no case of nonunion. Discussion and Conclusion. To manage the osteoporotic fracture of proximal femur in children, a thorough understanding of the risks associated with it is essential for decision making of increasing successful results


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 77 - 79
1 Jan 1999
Weatherall M

In three consecutive years 462 patients over the age of 60 years presented at Waikato Hospital, Hamilton, New Zealand, with a fracture of the proximal femur. Within two years, 11 (2.4%) returned with a fracture of the contralateral femur. If the effectiveness of any form of treatment aiming at reducing the incidence of contralateral fracture were subjected to a trial, a sample size of 5000, randomly distributed equally between treatment and placebo groups, would be needed for the trial to have a power of 80% to detect a reduction


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 13 - 13
1 Jun 2017
Leung AH Duncan R
Full Access

The Fassier-Duval (FD) rod, which offers a single-entry design and allows elongation for growth, has been widely adopted in paediatric deformity correction over the past decade, although evidence is limited in literature regarding the associated complications from its use. All FD roddings carried out in a Scottish tertiary referral centre were identified. The electronic records and radiographs of each procedure were reviewed. The follow-up duration, indications for surgery, complications arisen and further operations were recorded. 21 procedures in 11 patients were identified between 2009–2016. The mean age at operation was 6 years and 2 months. The median follow-up period was 3 years and 9 months. The main underlying pathology was osteogenesis imperfecta (71.4%, n=15). The main indication of surgery was deformity correction (61.9%, n=13). 11 (52.4%) FD roddings were for femur and the remainder were for tibia. The commonest complication was proximal migration (n=6, 28.6%). In our cohort we did not have negative telescoping or non-union. Two procedures (9.5%) were complicated by deep infections which were successfully treated. There were 3 further operations (14.3%), including one revision to a locked intramedullary nail for fracture and one below knee amputation for recurrent pseudarthrosis. We compared our results with those from Birke and co (J Paediatr Orthop 2011) from Australia. Our results are comparable and with a longer follow-up period. Although FD rodding allows children to maintain their mobility and prevent fractures, there are significant complications associated with its use. We hope in the future other centres can publish their results to allow improvements in surgical practice and implant design


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 967 - 971
1 Sep 2000
Patton JT Cook RE Adams CI Robinson CM

In a consecutive series of 498 patients with 528 fractures of the femur treated by conventional interlocking intramedullary nailing, 14 fractures of the femoral neck (2.7%) occurred in 13 patients. The fracture of the hip was not apparent either before operation or on the immediate postoperative radiographs. It was diagnosed in the first two weeks after operation in three patients and after three months in the remainder. Age over 60 years at the time of the femoral fracture and female gender were significantly predictive of hip fracture on bivariate logistic regression analysis, but on multivariate analysis only the location of the original fracture in the proximal third of the femur (p = 0.0022, odds ratio = 6.96, 95% CI 2.01 to 24.14), low-energy transfer (p = 0.0264, odds ratio = 15.56, 95% CI 1.38 to 75.48) and the severity of osteopenia on radiographs (p = 0.0128, odds ratio = 7.55, 95% CI 1.54 to 37.07) were significant independent predictors of later fracture. Five of the 19 women aged over 60 years, who sustained an osteoporotic proximal diaphyseal fracture of the femur during a simple fall, subsequently developed a fracture of the neck. Eleven of the hip fractures were displaced and intracapsular and, in view of the advanced age of most of these patients, were usually treated by replacement arthroplasty. Reduction and internal fixation was used to treat the remaining three intertrochanteric fractures. Three patients developed complications requiring further surgery; five died within two years of their fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1064 - 1068
1 Aug 2009
Sankey RA Turner J Lee J Healy J Gibbons CER

An MR scan was performed on all patients who presented to our hospital with a clinical diagnosis of a fracture of the proximal femur, but who had no abnormality on plain radiographs. This was a prospective study of 102 consecutive patients over a ten-year period. There were 98 patients who fulfilled our inclusion criteria, of whom 75 were scanned within 48 hours of admission, with an overall mean time between admission and scanning of 2.4 days (0 to 10). A total of 81 patients (83%) had abnormalities detected on MRI; 23 (23%) required operative management. The use of MRI led to the early diagnosis and treatment of occult hip pathology. We recommend that incomplete intertrochanteric fractures are managed non-operatively with protected weight-bearing. The study illustrates the high incidence of fractures which are not apparent on plain radiographs, and shows that MRI is useful when diagnosing other pathology such as malignancy, which may not be apparent on plain films


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1361 - 1366
1 Oct 2006
Moroz LA Launay F Kocher MS Newton PO Frick SL Sponseller PD Flynn JM

Between 1996 and 2003 six institutions in the United States and France contributed a consecutive series of 234 fractures of the femur in 229 children which were treated by titanium elastic nailing. Minor or major complications occurred in 80 fractures. Full information was available concerning 230 fractures, of which the outcome was excellent in 150 (65%), satisfactory in 57 (25%), and poor in 23 (10%). Poor outcomes were due to leg-length discrepancy in five fractures, unacceptable angulation in 17, and failure of fixation in one. There was a statistically significant relationship (p = 0.003) between age and outcome, and the odds ratio for poor outcome was 3.86 for children aged 11 years and older compared with those below this age. The difference between the weight of children with a poor outcome and those with an excellent or satisfactory outcome was statistically significant (54 kg vs 39 kg; p = 0.003). A poor outcome was five times more likely in children who weighed more than 49 kg


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 393 - 398
1 Mar 2011
Findlay JM Keogh MJ Boulton C Forward DP Moran CG

We performed a retrospective study of a departmental database to assess the efficacy of a new model of orthopaedic care on the outcome of patients with a fracture of the proximal femur. All 1578 patients admitted to a university teaching hospital with a fracture of the proximal femur between December 2007 and December 2009 were included. The allocation of Foundation doctors years 1 and 2 was restructured from individual teams covering several wards to pairs covering individual wards. No alterations were made in the numbers of doctors, their hours, out-of-hours cover, or any other aspect of standard patient care. Outcome measures comprised 30-day mortality and cause, complications and length of stay. Mortality was reduced from 11.7% to 7.6% (p = 0.007, Cox’s regression analysis); adjusted odds ratio was 1.559 (95% confidence interval 1.128 to 2.156). Reductions were seen in Clostridium difficile colitis (p = 0.017), deep wound infection (p = 0.043) and gastrointestinal haemorrhage (p = 0.033). There were no differences in any patient risk factors (except the prevalence of chronic obstructive pulmonary disease), cause of death and length of stay before and after intervention. The underlying mechanisms are unclear, but may include improved efficiency and medical contact time. These findings may have implications for all specialties caring for patients on several wards, and we believe they justify a prospective trial to further assess this effect


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 95 - 95
1 Apr 2013
Wong M Amila MG
Full Access

Introduction. Femur neck fractures (NOF) in the young could result in mal-union, non-union and avascular necrosis of the femoral head. Osteosynthesis is the standard of management in NOFs in young patient above complications sometimes end in Arthroplasty. The aim of our study is to identify predictors of NOF failures in the young population. Method. A retrospective study conducted in a single center. Patients with NOF fractures below the age of <50y excluding pathological and osteoporotic fractures were assessed in the period from 2005–2008. The mean follow-up was 22 months (6–40). Fractures were classified according to Gardens classification. Our Aim was to identify causative factors for fixation failures. Analysis was done using SPSS 17.0. Results. Within the 4 year period we identified 41 NOF fractures, 24 (75%) fractures were displaced. 7 (25%) out of the displaced fractures went in to failure and required arthroplasty. 3 (42%) went in to avascular necrosis and 2(28.5%) went in to screw cut out and non unions. All failures were primarily fixed with cancellous screws. We identified Male sex (p=0.03), Pre-operative delay of >25h (p=0.04), Chronic alcohol intake (p=0.02) and intra operative time >107min (p=0.001) as the main predictors of NOF failures in the young. Conclusion. Early surgical intervention within 25h, restricting the operation time to less than 107min would reduce the failure rates. We would recommend arthroplasty for patients who are chronic alcoholics