Advertisement for orthosearch.org.uk
Results 1 - 20 of 103
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 55 - 55
2 May 2024
McCann C Ablett A Feng T Macaskill V Oliver W Keating J
Full Access

Subtrochanteric femoral fractures are a subset of hip fractures generally treated with cephalomedullary nail fixation\[1\]. Single lag screw devices are most commonly-used, but integrated dual screw constructs have become increasingly popular\[2,3\]. The aim of this study was to compare outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or peri-implant fracture.

Consecutive adult patients (18yrs) with subtrochanteric femoral fracture treated in a single centre were retrospectively identified using electronic records. Patients that underwent surgical fixation using either a long GN (2010–2017) or IN (2017–2022) were included. Medical records and radiographs were reviewed to identify complications of fixation. Cox regression analysis was used to determine the risk of mechanical failure and secondary outcomes by implant design. Multivariable regression models were used to identify predictors of mechanical failure.

The study included 622 patients, 354 in the GN group (median age 82yrs, 72% female) and 268 in the IN group (median age 82yrs, 69% female). The risk of any mechanical failure was increased two-fold in the GN group (HR 2.44 \[95%CI 1.13 to 5.26\]; _p=0.024_). Mechanical failure comprising screw cut-out (_p=0.032_), back-out (_p=0.032_) and nail breakage (_p=0.26_) was only observed in the GN group. Technical predictors of failure included varus >5° for cut-out (OR 19.98 \[2.06 to 193.88\]; _p=0.01_), TAD;25mm for back-out (8.96 \[1.36 to 58.86\]; p=0.022) and shortening 1cm for peri-implant fracture (7.81 \[2.92 to 20.91\]; _p=<0.001_).

Our results demonstrate that an intercalated screw construct is associated with a lower risk of mechanical failure compared with the a single lag screw device. Intercalated screw designs may reduce the risk of mechanical complications for patients with subtrochanteric femoral fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1036 - 1044
1 Aug 2012
Penny JO Brixen K Varmarken JE Ovesen O Overgaard S

It is accepted that resurfacing hip replacement preserves the bone mineral density (BMD) of the femur better than total hip replacement (THR). However, no studies have investigated any possible difference on the acetabular side.

Between April 2007 and March 2009, 39 patients were randomised into two groups to receive either a resurfacing or a THR and were followed for two years. One patient’s resurfacing subsequently failed, leaving 19 patients in each group.

Resurfaced replacements maintained proximal femoral BMD and, compared with THR, had an increased bone mineral density in Gruen zones 2, 3, 6, and particularly zone 7, with a gain of 7.5% (95% confidence interval (CI) 2.6 to 12.5) compared with a loss of 14.6% (95% CI 7.6 to 21.6). Resurfacing replacements maintained the BMD of the medial femoral neck and increased that in the lateral zones between 12.8% (95% CI 4.3 to 21.4) and 25.9% (95% CI 7.1 to 44.6).

On the acetabular side, BMD was similar in every zone at each point in time. The mean BMD of all acetabular regions in the resurfaced group was reduced to 96.2% (95% CI 93.7 to 98.6) and for the total hip replacement group to 97.6% (95% CI 93.7 to 101.5) (p = 0.4863). A mean total loss of 3.7% (95% CI 1.0 to 6.5) and 4.9% (95% CI 0.8 to 9.0) of BMD was found above the acetabular component in W1 and 10.2% (95% CI 0.9 to 19.4) and 9.1% (95% CI 3.8 to 14.4) medial to the implant in W2 for resurfaced replacements and THRs respectively. Resurfacing resulted in a mean loss of BMD of 6.7% (95% CI 0.7 to 12.7) in W3 but the BMD inferior to the acetabular component was maintained in both groups.

These results suggest that the ability of a resurfacing hip replacement to preserve BMD only applies to the femoral side.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 19 - 19
19 Aug 2024
Macheras G Kostakos T Tzefronis D
Full Access

Total hip arthroplasty (THA) for congenital hip dysplasia (CDH) presents a challenge. In high-grade CDH, key surgical targets include cup placement in the anatomical position and leg length equality. Lengthening of more than 4 cm is associated with sciatic nerve injury, therefore shortening osteotomies are necessary. We present our experience of different shortening osteotomies including advantages and disadvantages of each technique. 89 hips, in 61 pts (28 bilateral cases), for high CDH were performed by a single surgeon from 1997 to 2022. 67 patients were female and 22 were male. Age ranged from 38 to 68 yrs. In all patients 5–8cm of leg length discrepancy (LLD) was present, requiring shortening femoral osteotomy. 12 patients underwent sequential proximal femoral resection with trochanteric osteotomy, 46 subtrochanteric, 6 midshaft, and 25 distal femoral osteotomies with simultaneous valgus correction were performed. All acetabular prostheses were placed in the true anatomical position. We used uncemented high porosity cups. Patients were followed up for a minimum of 12 months. All osteotomies healed uneventfully except 3 non-unions of the greater trochanter in the proximal femur resection group. No femoral shaft fractures in proximally based osteotomies. No significant LLD compared to the unaffected or reconstructed side. 2 patients suffered 3 and 5 degrees malrotation of the femur in the oblique sub-trochanteric group. 3 patients suffered transient sciatic nerve palsies. Shortening femoral osteotomies in the treatment of DDH are necessary to avoid injury to the sciatic nerve. In our series, we found transverse subtrochanteric osteotomies to be the most technically efficient, versatile and predictable in their clinical outcome, due to the ability to correct rotation and preserve the metaphyseal bone integrity, allowing for better initial stem stability. Distal femoral osteotomies allowed for controllable correction of valgus knee deformity


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 49 - 49
19 Aug 2024
Beverland D Wong ML Robinson M Cassidy R Lamb J Diamond O
Full Access

A: - determine the incidence of intraoperative periprosthetic femoral fracture (PFF). B: - determine the incidence of, and the reoperation rate for postoperative PFF. When using either CC or PTS femoral components. Retrospective review of a consecutive series of 11,018 THAs over a ten-year period. All PFFs were identified using regional radiograph archiving and electronic care systems. Of the 11,018 THAs 4,952 were CC and 6,066 were PTS. Between groups, age, sex, and BMI did not differ. A: - 55 (0.5%) had an intraoperative PFF. 44 CC and 11 PTS (p<0.001). 3 patients in each group had a femoral shaft fracture, remaining fractures were either the calcar (20 CC and 2 group) or the greater trochanter (11 CC and 6 PTS). B: - 91(0.8%) sustained a postoperative PFF. Of those 15 were managed conservatively, 15 were revised and 61 (80.3%) had an ORIF. The CC group had both a lower overall rate of postoperative PFFs (0.7% (36/4,952) vs 0.9% (55/6,066); p = 0.341), and a lower rate of return to theatre (0.4% (22/4,952) vs 0.9% (54/6,066); p = 0.005). 1.3% of male PTS (36/2,674) had a reoperation compared to 0.3% of male CC (7/2,121) (p<0.001). With regard to stem fracture there were none in the Corail group and 5 in the Exeter group. Of these 2 were sub trunnion and 3 were basal neck. A: - There were significantly more intraoperative PFFs with CC 44 (0.8%) than PTS 11 (0.2%). However, the majority of fractures were either of the calcar or greater trochanter with no impact on early recovery or one year Oxford scores. B: - Male PTS were five times more likely to have a reoperation for postoperative PFF. Females had the same incidence of reoperation with either component type. There were 5 stem fractures in the Exeter group and none in the Corail. These results represent robust estimates, which are likely to be more accurate than revision only studies typically generated from registry data


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 18 - 18
1 Nov 2021
Sedel L Bizot P Garcia-Cimbrelo E
Full Access

Fracture risks are the most common argument against the use of Ceramic on ceramic (CoC) hip implants. Question: is ceramic material at risk in case of severe local trauma?. Over a long period, we tried to identify patients with a CoC prosthesis (Ceraver Osteal°)who did sustain a trauma. This was conducted in three different institutions. Eleven patients were found: 9 males and 2 females aged 17 to 70 years at time of index surgery. Accident occurred 6 months to 15 years after index: one car accident, five motorcycle accident, five significant trauma after a fall, including one ski board accident. Consequences of these trauma were: six fractures of the acetabulum with socket loosening in 4 that needed revision, two femoral shaft fracture, one orifed and one stem exchanged, one traumatic hip dislocation associated to loosening of the socket revised at 10 years, and one traumatic loosening of the socket. Ten had no consequence on ceramic integrity. One experienced a fracture of the patella from a dashboard trauma, a liner shipping was discovered during socket revision 2 years later. This is the only case of possible relation between trauma and ceramic fracture. In a more recent longitudinal study on 1856 CoC prosthesis performed from 2010 to 2021, 29 severe traumas were identified with no consequence on Ceramic material. From this limited case study, it can be assumed that Pure Alumina Ceramic well designed and manufactured, will not break after a significant trauma


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 65 - 65
19 Aug 2024
Walter W Lin D Weinrauch P de Smet K Beaule P Young D Xu J Manktelow A
Full Access

Hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty. We present the early 2-year clinical and radiographic follow-up of a novel ceramic-on-ceramic (CoC) HRA in an international multi-centric cohort. Patients undergoing HRA between September 2018 and January 2021 were prospectively included. Patient-reported outcome measures (PROMS) in the form of the Forgotten Joint Score (FJS), HOOS Jr, WOMAC, Oxford Hip Score (OHS) and UCLA Activity Score were collected preoperatively and at 1- and 2-years post-operation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis/loosening and heterotopic ossification formation. 200 patients were identified to have reached 2-year follow-up. Of these, 185 completed PROMS follow-up at 2 years. There was significant improvement in HOOS (p< 0.001) and OHS (p< 0.001) and FJS (p< 0.001) between the pre-operative and 2-year outcomes. Patients reported improved pain (p<0.001), function (p<0.001) and reduced stiffness (p<0.001) as measured by the WOMAC score. Patients had improved activity scores on the UCLA Active Score (P<0.001) with 53% reporting return to impact activity at 2 years. There was no osteolysis and the mean acetabular cup inclination angle was 41deg and the femoral component shaft angle was 137deg. No fractures were reported over but there was one sciatic nerve palsy with partial recovery. Two patients were revised; one at 3 months for pain due to a misdiagnosed back problem and another at 33 months for loosening of the acetabular component with delamination of the titanium ingrowth surface. CoC resurfacing at 2-years post-operation demonstrate promising results with satisfactory PROMS


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 38 - 38
1 Jul 2020
Govaers K Philips T Vandekelft A
Full Access

We report on a cadaveric study and early experience using patient specific drill guides to prevent cortex perforations and reduce the need for a trochanteric osteotomy in revision THA. Mimic software (Materialise) was used for 3D analysis of the cement mantle and cement plug. Based on the CT findings a Cannulated drill guide with the shape of the femoral stem was printed in medical graded nylon intraoperative findings and complications were recorded on videotape using a standard 5mm laparoscope for medullary inspection. Surgical Technique was to attain a pre-operative CT scan with MARS protocol of the proximal femur to evaluate the femoral stem positioning, the 3D anatomy of the cement mantle, the length of the cement plug and the quality of the surrounding bone. Subsequent a 3D printing of patient specific cannulated drill guide with the shape of the removed femoral component but an eccentric cannulation was made. Endoscopic inspection was performed of the inside of the cement mantle, then insertion of the autoclaved cannulated drill guide in the existing cement mantle. After perforation of the distal plug through the PSI drill guide using either a long drill or an ultrasound plug perforation tool (Zimmer Biomet, Warsaw) the excessive cement was removed with standard available flexible femoral shaft reamers (Zimmer Biomet). Further laproscopic examination of the femoral canal performed to verify completeness of the cement removal. Results. CT scans with 3D reconstruction of the existing cement mantle is possible using Modern CT with MARS protocols. After the training on sawbones and cadaveric bones a predictable plug perforation was obtained in all clinical cases. There were no intraoperative cortex perforations and no intraoperative femoral fractures. Conclusion. CT scan analysis of femoral cement mantles together with patient specific drill guides are promising tools to reduce the risk of femoral perforation in revision total hip arthroplasty


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 19 - 19
1 May 2019
Lamb J Matharu G van Duren B Redmond A Judge A West R Pandit H
Full Access

Introduction. Intraoperative periprosthetic femoral fractures (IOPFF) lead to reduced implant survival. A deeper understanding of predictors enables surgeons to modify techniques and patient selection to reduce the risk of IOPFF. The aim of this study was to estimate predictors of IOPFF and each anatomical subtype (calcar crack, trochanteric fracture, femoral shaft fracture) during primary THA. Methods. This retrospective cohort study included 793823 primary THAs between 2004 and 2016. Relative risks for patient, surgical and implant factors are estimated for any IOPFF fracture and for all anatomical subtypes of IOPFF. Results. Patient factors significantly increasing the risk of fracture were: female gender, American Association of Anaesthesiologists (ASA) grade 3 to 5, pre-operative diagnosis including: avascular necrosis of the hip (AVN), previous trauma, inflammatory disease, paediatric disease and previous infection. Overall risk of IOPFF associated with age was greatest in patients below 50 years and above 80 years. Risk of any fracture reduced with computer guided surgery (CGS) and in non-NHS hospitals. Non-posterior approach's increased the risk of shaft and trochanteric fracture only. Cementless implants only significantly increased the risk of calcar cracks and shaft fractures and not trochanteric fractures. Conclusions. Fracture risk increases in patients less than 50 and older than 80, females, ASA grade 3 to 5 and indications other than primary osteoarthritis. Large cumulative reduction in IOPFF risk may occur with use of cemented implants, posterior approach and CGS. IOPFF may be further reduced by future developments in cementless stem implantation and non-posterior approaches which reduce the intraoperative strain placed on the femora


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 32 - 32
1 Oct 2019
Matta J Delagramaticas D Tatka J
Full Access

Background. Total hip arthroplasty requires proper sizing and placing of implants to ensure excellent outcomes and reduce complications. Calculation of femoral offset is an important consideration for optimal reconstruction of the hip biomechanics. Femoral offset can be measured on plain films or with flouroscopy if the x-ray beam is perpendicular to the plane determined by the angle between the neck axis and femoral shaft axis. This distance is evident only with the femur in the correct degree of rotation. Though pre-operative templating for femoral component size and offset is a regular accepted practice, a consistent method for assessing correct femoral rotation on the AP x-ray view has not been established. Purpose/Hypthesis. The purpose of the current study was to establish and validate a method for identifying radiographic landmarks on the proximal femur that would reliably indicate that the femur was in the proper degree of rotation to represent the true offset from the head center to shaft center. Methods. Lead markers were placed on areas of the greater trochanter followed by xrays. Markers placed on locations on the anterior and posterior greater trochanter duplicated reliable radiographic lines. Proximal femurs were dissected to the bone and rotated about their long axis from neutral rotation, defined at the point when the anterior and posterior aspects of the greater trochanter were aligned radiographically. Radiographs were taken at 2 degree increments in both internal and external rotation until 10 degrees, then again at 30 degrees. A custom script was used to calculate the femoral offset at these rotations at these locations. Descriptive analysis was performed to assess the relationship between rotation angle and femoral offset. Results. The mean femoral offset was observed to be 38.21 mm (SD 4.93, median 37.82, range 30.52–46.27). The mean rotation of max offset was −3.6° (SD 5.6, median −6, range −10 to +8). The average underestimation error (the difference between calculated offset at neutral rotation and observed maximum femoral offset) was 0.92 mm (median 0.74, range 0 to 2.07 mm). Conclusion. Alignment of the radiographic lines created by the anterior and posterior aspects of the greater trochanter is a reliable and accurate rotational positioning method for measuring femoral offset when using plain films or fluoroscopy. It is a feasible method that can be applied preoperatively and/or intraoperatively to optimize accuracy of femoral offset for THA procedures. For any tables or figures, please contact the authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 577 - 582
1 May 2009
Duncan WW Hubble MJW Howell JR Whitehouse SL Timperley AJ Gie GA

The removal of well-fixed bone cement from the femoral canal during revision of a total hip replacement (THR) can be difficult and risks the loss of excessive bone stock and perforation or fracture of the femoral shaft. Retaining the cement mantle is attractive, yet the technique of cement-in-cement revision is not widely practised. We have used this procedure at our hospital since 1989. The stems were removed to gain a better exposure for acetabular revision, to alter version or leg length, or for component incompatibility. We studied 136 hips in 134 patients and followed them up for a mean of eight years (5 to 15). A further revision was required in 35 hips (25.7%), for acetabular loosening in 26 (19.1%), sepsis in four, instability in three, femoral fracture in one and stem fracture in one. No femoral stem needed to be re-revised for aseptic loosening. A cement-in-cement revision of the femoral stem is a reliable technique in the medium term. It also reduces the risk of perforation or fracture of the femoral shaft


Bone & Joint Open
Vol. 3, Issue 10 | Pages 795 - 803
12 Oct 2022
Liechti EF Attinger MC Hecker A Kuonen K Michel A Klenke FM

Aims

Traditionally, total hip arthroplasty (THA) templating has been performed on anteroposterior (AP) pelvis radiographs. Recently, additional AP hip radiographs have been recommended for accurate measurement of the femoral offset (FO). To verify this claim, this study aimed to establish quantitative data of the measurement error of the FO in relation to leg position and X-ray source position using a newly developed geometric model and clinical data.

Methods

We analyzed the FOs measured on AP hip and pelvis radiographs in a prospective consecutive series of 55 patients undergoing unilateral primary THA for hip osteoarthritis. To determine sample size, a power analysis was performed. Patients’ position and X-ray beam setting followed a standardized protocol to achieve reproducible projections. All images were calibrated with the KingMark calibration system. In addition, a geometric model was created to evaluate both the effects of leg position (rotation and abduction/adduction) and the effects of X-ray source position on FO measurement.


Bone & Joint Research
Vol. 13, Issue 6 | Pages 294 - 305
17 Jun 2024
Yang P He W Yang W Jiang L Lin T Sun W Zhang Q Bai X Sun W Guo D

Aims

In this study, we aimed to visualize the spatial distribution characteristics of femoral head necrosis using a novel measurement method.

Methods

We retrospectively collected CT imaging data of 108 hips with non-traumatic osteonecrosis of the femoral head from 76 consecutive patients (mean age 34.3 years (SD 8.1), 56.58% male (n = 43)) in two clinical centres. The femoral head was divided into 288 standard units (based on the orientation of units within the femoral head, designated as N[Superior], S[Inferior], E[Anterior], and W[Posterior]) using a new measurement system called the longitude and latitude division system (LLDS). A computer-aided design (CAD) measurement tool was also developed to visualize the measurement of the spatial location of necrotic lesions in CT images. Two orthopaedic surgeons independently performed measurements, and the results were used to draw 2D and 3D heat maps of spatial distribution of necrotic lesions in the femoral head, and for statistical analysis.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 92 - 94
1 Nov 2013
Gehrke T Gebauer M Kendoff D

Femoral revision after cemented total hip replacement (THR) might include technical difficulties, following essential cement removal, which might lead to further loss of bone and consequently inadequate fixation of the subsequent revision stem. . Femoral impaction allografting has been widely used in revision surgery for the acetabulum, and subsequently for the femur. In combination with a primary cemented stem, impaction grafting allows for femoral bone restoration through incorporation and remodelling of the impacted morsellized bone graft by the host skeleton. Cavitary bone defects affecting meta-physis and diaphysis leading to a wide femoral shaft, are ideal indications for this technique. Cancellous allograft bone chips of 1 mm to 2 mm size are used, and tapered into the canal with rods of increasing diameters. To impact the bone chips into the femoral canal a prosthesis dummy of the same dimensions of the definitive cemented stem is driven into the femur to ensure that the chips are very firmly impacted. Finally, a standard stem is cemented into the neo-medullary canal using bone cement. . To date several studies have shown favourable results with this technique, with some excellent long-term results reported in independent clinical centres worldwide. Cite this article: Bone Joint J 2013;95-B, Supple A:92–4


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 154 - 158
1 Feb 2008
Calder JD Hine AL Pearse MF Revell PA

Total hip replacement in patients with advanced osteonecrosis of the femoral head is often complicated by early loosening of the femoral component. Recent evidence has suggested that abnormal bone extending into the proximal femur may be responsible for the early failure of the femoral component. We aimed to identify which patients were at high risk of early failure by evaluating gadolinium-enhanced MR images of histologically-confirmed osteonecrotic lesions beyond the femoral head. Although the MR signal intensity has been shown to correlate well with osteonecrosis in the femoral head, it was found to be relatively insensitive at identifying lesions below the head, with a sensitivity of only 51% and a predictive value of a negative result of only 48%. However, the specificity was 90%, with the predictive value of a positive MRI finding being 86%. Only those patients with osteonecrosis of the femoral head secondary to sickle-cell disease, who are known to be at high risk of early loosening, had changes in the MR signal in the greater trochanter and the femoral shaft. This observation suggests that changes in the MR signal beyond the femoral head may represent osteonecrotic lesions in areas essential for the fixation of the femoral component. Pre-operative identification of such lesions in the neck of the femur may be important when considering hip resurfacing for osteonecrosis of the femoral head, following which early loosening of the femoral component and fracture of the neck are possible complications


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 435 - 441
1 May 2024
Angelomenos V Mohaddes M Kärrholm J Malchau H Shareghi B Itayem R

Aims

Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures.

Methods

Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 858 - 867
11 Oct 2024
Yamate S Hamai S Konishi T Nakao Y Kawahara S Hara D Motomura G Nakashima Y

Aims

The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy.

Methods

We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 898 - 906
1 Sep 2024
Kayani B Wazir MUK Mancino F Plastow R Haddad FS

Aims

The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system.

Methods

This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed.


Bone & Joint Open
Vol. 3, Issue 11 | Pages 877 - 884
14 Nov 2022
Archer H Reine S Alshaikhsalama A Wells J Kohli A Vazquez L Hummer A DiFranco MD Ljuhar R Xi Y Chhabra A

Aims

Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming radiological measurements are currently used to confirm HD. An artificial intelligence (AI) software named HIPPO automatically locates anatomical landmarks on anteroposterior pelvis radiographs and performs the needed measurements. The primary aim of this study was to assess the reliability of this tool as compared to multi-reader evaluation in clinically proven cases of adult HD. The secondary aims were to assess the time savings achieved and evaluate inter-reader assessment.

Methods

A consecutive preoperative sample of 130 HD patients (256 hips) was used. This cohort included 82.3% females (n = 107) and 17.7% males (n = 23) with median patient age of 28.6 years (interquartile range (IQR) 22.5 to 37.2). Three trained readers’ measurements were compared to AI outputs of lateral centre-edge angle (LCEA), caput-collum-diaphyseal (CCD) angle, pelvic obliquity, Tönnis angle, Sharp’s angle, and femoral head coverage. Intraclass correlation coefficients (ICC) and Bland-Altman analyses were obtained.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1623 - 1627
1 Dec 2015
Mounsey EJ Williams DH Howell JR Hubble MJ

Revision of a cemented hemiarthroplasty of the hip may be a hazardous procedure with high rates of intra-operative complications. Removing well-fixed cement is time consuming and risks damaging already weak bone or perforating the femoral shaft. The cement-in-cement method avoids removal of intact cement and has shown good results when used for revision total hip arthroplasty (THA). The use of this technique for the revision of a hemiarthroplasty to THA has not been previously reported. A total of 28 consecutive hemiarthroplasties (in 28 patients) were revised to a THA using an Exeter stem and the cement-in-cement technique. There were four men and 24 women; their mean age was 80 years (35 to 93). Clinical and radiographic data, as well as operative notes, were collected prospectively and no patient was lost to follow-up. Four patients died within two years of surgery. The mean follow up of the remainder was 70 months (25 to 124). Intra-operatively there was one proximal perforation, one crack of the femoral calcar and one acetabular fracture. No femoral components have required subsequent revision for aseptic loosening or are radiologically loose. . Four patients with late complications (14%) have since undergone surgery (two for a peri-prosthetic fracture, and one each for deep infection and recurrent dislocation) resulting in an overall major rate of complication of 35.7%. The cement-in-cement technique provides reliable femoral fixation in this elderly population and may reduce operating time and rates of complication. Cite this article: Bone Joint J 2015;97-B:1623–7


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.