Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 62 - 62
22 Nov 2024
Mueller MM Kowald B Gerlach U Grimme C Schulz A Frosch K Schoop-Schmetgens R
Full Access

Aim

Aim of this study was to establish the first clinical results after implantation of ultrathin silver-polysiloxane-coated1 plates in the treatment of infected non-union of the femoral shaft.

Method

As part of the REFECT study, a prospective, non-interventional analysis was conducted encompassing all patients who received internal stabilization with a silver-coated1 plate from 01/2023 to 09/2024 as part of the treatment for infected non-union of the femur. Standardized clinical follow-ups including PROMs (WOMAC-Index, LEF-S, EQ-5D, VAS) and X-rays were performed 3, 6, 12 (and 24) months postoperatively.

For comparison, a retrospective analysis of 76 patients with infected femoral non-union, who had received a stabilization with an uncoated plate in the past 10 years, was performed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 54 - 54
1 Nov 2016
Birch C Blankstein M Bartlett C
Full Access

Periprosthetic femoral shaft fractures are a significant complication of total hip arthroplasty. Plate osteosynthesis with or without onlay strut allograft has been the mainstay of treatment around well-fixed stems. Nonunions are a rare, challenging complication of this fixation method. The number of published treatment strategies for periprosthetic femoral nonunions are limited. In this series, we report the outcomes of a novel orthogonal plating surgical technique for addressing nonunions in the setting of Vancouver B1 and C-type periprosthetic fractures that previously failed open reduction internal fixation (ORIF). A retrospective chart review of all patients from 2010 to 2014 with Vancouver B1/C total hip arthroplasty periprosthetic femoral nonunions was performed. All patients were treated primarily with ORIF. Nonunion was defined as no radiographic signs of fracture healing nine months post-operatively, with or without hardware failure. Exclusion criteria included open fractures and periprosthetic infections. The technique utilised a mechanobiologic strategy of atraumatic exposure, resection of necrotic tissue, bone grafting with adjuvant recombinant growth factor and revision open reduction internal fixation. Initially, compression was achieved using an articulated tensioning device and application of an anterior plate. This was followed by locked lateral plating. Patients remained non-weight bearing for eight weeks. Six Vancouver B1/C periprosthetic femoral nonunions were treated. Five patients were female with an average age of 80.3 years (range 72–91). The fractures occurred at a mean of 5.8 years (range 1–10) from their initial arthroplasty procedure. No patients underwent further revision surgery; there were no wound dehiscence, hardware failures, infections, or surgical complications. All patients had a minimum of nine months follow up (mean 16.6, range 9–36). All fractures achieved osseous union, defined as solid bridging callus over at least two cortices and pain free, independent ambulation, at an average of 24.4 weeks (range 6.1–39.7 weeks). To our knowledge, this is the first case series describing 90–90 locked compression plating using modern implants for periprosthetic femoral nonunions. This is a rare but challenging complication of total hip arthroplasty and we present a novel solution with satisfactory preliminary outcomes. Orthogonal locked compression plating utilising an articulated tensioning device and autograft with adjuvant osteoinductive allograft should be considered in periprosthetic femur fractures around a well-fixed stem. Further biomechanical and clinical research is needed to improve our treatment strategies in this population


Bone & Joint Open
Vol. 1, Issue 6 | Pages 287 - 292
19 Jun 2020
Iliadis AD Eastwood DM Bayliss L Cooper M Gibson A Hargunani R Calder P

Introduction

In response to the COVID-19 pandemic, there was a rapidly implemented restructuring of UK healthcare services. The The Royal National Orthopaedic Hospital, Stanmore, became a central hub for the provision of trauma services for North Central/East London (NCEL) while providing a musculoskeletal tumour service for the south of England, the Midlands, and Wales and an urgent spinal service for London. This study reviews our paediatric practice over this period in order to share our experience and lessons learned. Our hospital admission pathways are described and the safety of surgical and interventional radiological procedures performed under general anaesthesia (GA) with regards to COVID-19 in a paediatric population are evaluated.

Methods

All paediatric patients (≤ 16 years) treated in our institution during the six-week peak period of the pandemic were included. Prospective data for all paediatric trauma and urgent elective admissions and retrospective data for all sarcoma admissions were collected. Telephone interviews were conducted with all patients and families to assess COVID-19 related morbidity at 14 days post-discharge.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 178 - 188
1 Feb 2019
Chaudhary MM Lakhani PH

Aims

Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator.

Patients and Methods

A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.