Advertisement for orthosearch.org.uk
Results 1 - 20 of 619
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 357 - 360
1 Mar 2009
Dalury DF Mason JB Murphy JA Adams MJ

Gender-specific total knee replacement has generated much interest recently. We reviewed 1970 Sigma knees implanted in 920 women and 592 men with a mean age of 69.7 years.

At a mean follow-up of 7.3 years (minimum, five years), we found minimal differences in the outcome between genders. At the final follow-up, men had a higher overall Knee Society score and more osteolysis (3.8% vs 1.1%). However, there were no significant differences between men and women in terms of complications or improvements in knee function, pain score or range of movement. The estimated ten-year survivorship was 97% in women and 98% in men (p = 0.96).

We concluded that there was little difference in outcome between the genders treated by a modern unisex design of total knee replacement in this large multicentre study.


Bone & Joint Research
Vol. 13, Issue 6 | Pages 279 - 293
7 Jun 2024
Morris JL Letson HL McEwen PC Dobson GP

Aims. Adenosine, lidocaine, and Mg. 2+. (ALM) therapy exerts differential immuno-inflammatory responses in males and females early after anterior cruciate ligament (ACL) reconstruction (ACLR). Our aim was to investigate sex-specific effects of ALM therapy on joint tissue repair and recovery 28 days after surgery. Methods. Male (n = 21) and female (n = 21) adult Sprague-Dawley rats were randomly divided into ALM or Saline control treatment groups. Three days after ACL rupture, animals underwent ACLR. An ALM or saline intravenous infusion was commenced prior to skin incision, and continued for one hour. An intra-articular bolus of ALM or saline was also administered prior to skin closure. Animals were monitored to 28 days, and joint function, pain, inflammatory markers, histopathology, and tissue repair markers were assessed. Results. Despite comparable knee function, ALM-treated males had reduced systemic inflammation, synovial fluid angiogenic and pro-inflammatory mediators, synovitis, and fat pad fibrotic changes, compared to controls. Within the ACL graft, ALM-treated males had increased expression of tissue repair markers, decreased inflammation, increased collagen organization, and improved graft-bone healing. In contrast to males, females had no evidence of persistent systemic inflammation. Compared to controls, ALM-treated females had improved knee extension, gait biomechanics, and elevated synovial macrophage inflammatory protein-1 alpha (MIP-1α). Within the ACL graft, ALM-treated females had decreased inflammation, increased collagen organization, and improved graft-bone healing. In articular cartilage of ALM-treated animals, matrix metalloproteinase (MMP)-13 expression was blunted in males, while in females repair markers were increased. Conclusion. At 28 days, ALM therapy reduces inflammation, augments tissue repair patterns, and improves joint function in a sex-specific manner. The study supports transition to human safety trials. Cite this article: Bone Joint Res 2024;13(6):279–293


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 672 - 679
1 Jun 2022
Tay ML Young SW Frampton CM Hooper GJ

Aims. Unicompartmental knee arthroplasty (UKA) has a higher risk of revision than total knee arthroplasty (TKA), particularly for younger patients. The outcome of knee arthroplasty is typically defined as implant survival or revision incidence after a defined number of years. This can be difficult for patients to conceptualize. We aimed to calculate the ‘lifetime risk’ of revision for UKA as a more meaningful estimate of risk projection over a patient’s remaining lifetime, and to compare this to TKA. Methods. Incidence of revision and mortality for all primary UKAs performed from 1999 to 2019 (n = 13,481) was obtained from the New Zealand Joint Registry (NZJR). Lifetime risk of revision was calculated for patients and stratified by age, sex, and American Society of Anesthesiologists (ASA) grade. Results. The lifetime risk of revision was highest in the youngest age group (46 to 50 years; 40.4%) and decreased sequentially to the oldest (86 to 90 years; 3.7%). Across all age groups, lifetime risk of revision was higher for females (ranging from 4.3% to 43.4% vs males 2.9% to 37.4%) and patients with a higher ASA grade (ASA 3 to 4, ranging from 8.8% to 41.2% vs ASA 1 1.8% to 29.8%). The lifetime risk of revision for UKA was double that of TKA across all age groups (ranging from 3.7% to 40.4% for UKA, and 1.6% to 22.4% for TKA). The higher risk of revision in younger patients was associated with aseptic loosening in both sexes and pain in females. Periprosthetic joint infection (PJI) accounted for 4% of all UKA revisions, in contrast with 27% for TKA; the risk of PJI was higher for males than females for both procedures. Conclusion. Lifetime risk of revision may be a more meaningful measure of arthroplasty outcomes than implant survival at defined time periods. This study highlights the higher lifetime risk of UKA revision for younger patients, females, and those with a higher ASA grade, which can aid with patient counselling prior to UKA. Cite this article: Bone Joint J 2022;104-B(6):672–679


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 444 - 451
1 Apr 2022
Laende EK Mills Flemming J Astephen Wilson JL Cantoni E Dunbar MJ

Aims. Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA. Methods. Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients). Longitudinal analysis of data using marginal models was performed to examine the associations of patient factors (age, sex, BMI, smoking status) and implant factors (cemented or uncemented, the size of the implant) with maximum total point motion (MTPM) migration. Analyses were also performed on subgroups based on sex and fixation. Results. In the overall group, only fixation was significantly associated with migration (p < 0.001). For uncemented tibial components in males, smoking was significantly associated with lower migration (p = 0.030) and BMI approached significance (p = 0.061). For females with uncemented components, smoking (p = 0.081) and age (p = 0.063) approached significance and were both associated with increased migration. The small number of self-reported smokers in this study warrants cautious interpretation and further investigation. For cemented components in females, larger sizes of tibial component were significantly associated with increased migration (p = 0.004). No factors were significant for cemented components in males. Conclusion. The migration of uncemented tibial components was more sensitive to patient factors than cemented implants. These differences were not consistent by sex, suggesting that it may be of value to evaluate female and male patients separately following TKA. Cite this article: Bone Joint J 2022;104-B(4):444–451


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 15 - 15
7 Aug 2023
Deo S Jonas S Jhaj J
Full Access

Abstract. INTRODUCTION. The most frequent mode of aseptic failure of primary total knee replacements is tibial baseplate loosening. This is influenced by stresses across the implant-bone interface which can be increased in obese patients leading to potentially higher rates of early failure. The evidence is mixed as to the true effect of elevated BMI (body mass index) on revision rates. We present the experience of early tibial failures in our department and how our implant choices have evolved. METHODOLOGY. We retrospectively reviewed our unit's arthroplasty database and identified all patients who had sustained mechanical tibial failure. Data were collected on patient demographics, operative details of primary and revision operations, components used, alignment pre and post operatively and indication. Complications and further surgery performed were recorded. RESULTS. 12 patients were identified who had been revised for mechanical tibial failure. All were female, mean age 60 years (46–76). Mean BMI was 11/12 had significant comorbidities and 6/12 had risk factors for reduced bone density (inflammatory arthritis, diabetes, hypothyroid). CONCLUSION. In our consecutive series of 12 patients who presented with tibial mechanical failure, all were female and had a high BMI with the majority over 40. We recommend that a stemmed tibia construct should be used in female patients with an elevated BMI, particularly if it is over 40


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 7 - 7
7 Aug 2023
Abdul W Moore I Robertson A
Full Access

Abstract. Introduction. Perception of ACL injury prevention programs amongst professional netball players and coaches has not been studied. We investigated (1) level of awareness and experience of ACL injury prevention programs; (2) use of ACL injury prevention programs; and (3) barriers to implementing ACL injury prevention program in netball. Methodology. Female netball players representing Welsh senior and under-21 teams and elite and amateur coaches were invited electronically to this web-based study between 1st May–31st July 2021. Information on ACL injury susceptibility and seriousness, knowledge, experience, and implementation of ACL injury prevention programs were ascertained. Results. Twenty-eight players (77.8%) and 29 coaches (13.2%) completed the questionnaire. Seventeen (60.7%) players and 15 (51.7%) coaches reported female athletes were at greater risk for sustaining ACL injuries. Over 90% of respondents identified netball as high-risk, whilst 89% of players and 76% of coaches reported these injuries to be preventable. Two (7.1%) players and 6 (20.7%) coaches utilised ACL injury prevention programs with lack of time and engagement from coaches and players identified. Majority of respondents indicated that their club has neither promoted, advocated nor demonstrated exercises for ACL injury prevention. Over 90% of respondents would utilise such programs if it minimised players risk with appropriate training and information. Conclusion. Study highlights limited knowledge of female athletes’ increased susceptibility of ACL injuries with lack of communication and education of ACL injury prevention programs between sporting associations, coaches and players. Results demonstrate willingness of players and coaches to implement ACL injury prevention programs in Welsh netball


Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Methods. Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95. th. percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone. Results. Peak tensile strains occurred on the anterior portion of the medial sagittal cut in all simulations. Lateral translation of the medial implant in Bi-UKA had the largest increase in ROF of any of the implant positions (43%). Overstuffing the joint by 2 mm had a much larger effect, resulting in a six-fold increase in ROF. Bi-UKA had ~10% increased ROF compared to UKA-M for both the male and female models, although the smaller, less dense female model had a 1.4 times greater ROF compared to the male model. Removal of anterior bone akin to BCR-TKA doubled ROF compared to Bi-UKA. Conclusion. Tibial eminence avulsion fracture has a similar risk associated with Bi-UKA to UKA-M. The risk is higher for smaller and less dense tibiae. To minimize risk, it is most important to avoid overstuffing the joint, followed by correctly positioning the medial implant, taking care not to narrow the bone island anteriorly. Cite this article: Bone Joint Res 2022;11(8):575–584


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 613 - 619
2 May 2022
Ackerman IN Busija L Lorimer M de Steiger R Graves SE

Aims. This study aimed to describe the use of revision knee arthroplasty in Australia and examine changes in lifetime risk over a decade. Methods. De-identified individual-level data on all revision knee arthroplasties performed in Australia from 2007 to 2017 were obtained from the Australian Orthopaedic Association National Joint Replacement Registry. Population data and life tables were obtained from the Australian Bureau of Statistics. The lifetime risk of revision surgery was calculated for each year using a standardized formula. Separate calculations were undertaken for males and females. Results. In total, 43,188 revision knee arthroplasty procedures were performed in Australia during the study period, with a median age at surgery of 69 years (interquartile range (IQR) 62 to 76). In 2017, revision knee arthroplasty rates were highest for males aged 70 to 79 years (102.9 procedures per 100,000 population). Lifetime risk of revision knee arthroplasty for females increased slightly from 1.61% (95% confidence interval (CI) 1.53% to 1.69%) in 2007 to 2.22% (95% CI 2.13% to 2.31%) in 2017. A similar pattern was evident for males, with a lifetime risk of 1.43% (95% CI 1.36% to 1.51%) in 2007 and 2.02% (95% CI 1.93% to 2.11%) in 2017. A decline in procedures performed for loosening/lysis (from 41% in 2007 to 24% in 2017) and pain (from 14% to 9%) was evident, while infection became an increasingly common indication (from 19% in 2007 to 29% in 2017). Conclusion. Well-validated national registry data can help us understand the epidemiology of revision knee arthroplasty, including changing clinical indications. Despite a small increase over a decade, the lifetime risk of revision knee arthroplasty in Australia is low at one in 45 females and one in 50 males. These methods offer a population-level approach to quantifying revision burden that can be used for ongoing national surveillance and between-country comparisons. Cite this article: Bone Joint J 2022;104-B(5):613–619


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 77 - 77
1 Jul 2022
Sabah S Sina J Alvand A Beard D Price A
Full Access

Abstract. Introduction. Anxiety and depression are risk factors for poor outcome following knee replacement surgery. The aim of this study was to investigate the prevalence of anxiety and depression before and after primary (pKR) and revision knee replacement (rKR). Methodology. Retrospective cohort study. 315,720 pKR and 12,727 rKR recruited from the NHS Patient Reported Outcome Measures (PROMs) programme from 2013–2021. Anxiety and depression were defined using: (i) Survey question: “Have you been told by a doctor that you have depression? Yes/No”; (ii) EQ-5D anxiety/depression domain. Rates of EQ-5D anxiety/depression were investigated at baseline and at 6-months following surgery. The prevalence of depression was investigated by patient age and gender. Results. Overall, 28,434/315,720 (9.0%) pKR and 1,536/12,727 (12.0%) rKR reported pre-operative depression. For all age groups, depression was more common in female than male patients. Prevalence of depression reduced with age (<60 years: 16.8% pKR, 22.7% rKR; 80+ years: 5.3% pKR, 5.2% rKR). Depression was most prevalent in female patients, under 60 years undergoing rKR (25.6%). Pre-operation, 109,000/303,998 (35.9%) pKR and 5,433/12,216 rKR (44.5%) reported moderate or extreme EQ-5D anxiety/depression. Post-operation, 65,351/308,914 (21.2%) pKR and 4,176/12,409 rKR (33.7%) reported moderate or extreme EQ-5D anxiety/depression. Conclusion. Anxiety and depression were prevalent in patients undergoing knee replacement surgery. Patients undergoing revision procedures, female patients and younger patients had the highest rates of depression. Large improvements in anxiety/depression were observed at early follow-up after pKR and rKR


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims. The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with ‘any cause revision’ was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion. In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%. Cite this article: Bone Jt Open 2023;4(10):776–781


Bone & Joint Research
Vol. 12, Issue 1 | Pages 58 - 71
17 Jan 2023
Dagneaux L Limberg AK Owen AR Bettencourt JW Dudakovic A Bayram B Gades NM Sanchez-Sotelo J Berry DJ van Wijnen A Morrey ME Abdel MP

Aims. As has been shown in larger animal models, knee immobilization can lead to arthrofibrotic phenotypes. Our study included 168 C57BL/6J female mice, with 24 serving as controls, and 144 undergoing a knee procedure to induce a contracture without osteoarthritis (OA). Methods. Experimental knees were immobilized for either four weeks (72 mice) or eight weeks (72 mice), followed by a remobilization period of zero weeks (24 mice), two weeks (24 mice), or four weeks (24 mice) after suture removal. Half of the experimental knees also received an intra-articular injury. Biomechanical data were collected to measure passive extension angle (PEA). Histological data measuring area and thickness of posterior and anterior knee capsules were collected from knee sections. Results. Experimental knees immobilized for four weeks demonstrated mean PEAs of 141°, 72°, and 79° after zero, two, and four weeks of remobilization (n = 6 per group), respectively. Experimental knees demonstrated reduced PEAs after two weeks (p < 0.001) and four weeks (p < 0.0001) of remobilization compared to controls. Following eight weeks of immobilization, experimental knees exhibited mean PEAs of 82°, 73°, and 72° after zero, two, and four weeks of remobilization, respectively. Histological analysis demonstrated no cartilage degeneration. Similar trends in biomechanical and histological properties were observed when intra-articular violation was introduced. Conclusion. This study established a novel mouse model of robust knee contracture without evidence of OA. This was appreciated consistently after eight weeks of immobilization and was irrespective of length of remobilization. As such, this arthrofibrotic model provides opportunities to investigate molecular pathways and therapeutic strategies. Cite this article: Bone Joint Res 2023;12(1):58–71


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims. Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length. Results. The algorithm measured 1,078 radiographs at a rate of 12.6 s/image (2,156 unique measurements in 3.8 hours). There was no significant difference or bias between reader and algorithm measurements for the FMAA (p = 0.130 to 0.563). The FMAA was 6.3° (SD 1.0°; 25% outside range of 5.0° (SD 2.0°)) using definition one and 4.6° (SD 1.3°; 13% outside range of 5.0° (SD 2.0°)) using definition two. Differences between males and females were observed using definition two (males more valgus; p < 0.001). Conclusion. We developed a rapid and accurate DL tool to quantify the FMAA. Considerable variation with different measurement approaches for the FMAA supports that patient-specific anatomy and surgeon-dependent technique must be accounted for when correcting for the FMAA using an intramedullary guide. The angle between the mechanical and anatomical axes of the femur fell outside the range of 5.0° (SD 2.0°) for nearly a quarter of patients. Cite this article: Bone Jt Open 2024;5(2):101–108


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 14 - 14
1 Jul 2022
Ragab A Gwyn R Davies A
Full Access

Abstract. Introduction. Patella Baja is a known complication of TKR. In this study, we report the effect of the senior author's change of practice from total excision to minimal resection of Hoffa's fat pad on patellar height. Methods. Retrospective analysis of a prospective series of TKRs performed or directly supervised by the senior author. Group 1 included 72 patients performed before April 2011 who had complete excision of Hoffa's fat pad to improve exposure during their TKR procedures. Group 2 included 138 patients performed after April 2011 who had the minimum excision of Hoffa's fat pad to allow exposure. There were no other changes in surgical technique, implant choice or rehabilitation protocol during this time. Patellar height was measured using the Caton–Deschamps Index (CDI) on standard lateral radiographs immediately postoperative and at a minimum follow up of 1 year. Results. Group 1 included 28 males, 44 females with mean age 68.36 years. The mean CDI in this group changed from 0.54 immediately post-operatively to 0.46 at minimum one year follow-up (P=0.001) indicating progressive Patella Baja. Group 2 included 56 males, 82 females with mean age 65 years. The mean CDI changed from 0.67 immediately post-operative to 0.68 at minimum one year post follow-up (P= 0.32) indicating no statistically or clinically relevant post-operative change in patellar height. Conclusions. Total excision of Hoffa's fat pad is associated with progressive post-operative patella baja which can be avoided by resecting the minimum amount of fat pad to allow adequate exposure


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 71 - 71
1 Jul 2022
Santini A Jamal J Wong P Lane B Wood A Bou-Gharios G Frostick S Roebuck M
Full Access

Abstract. Introduction. Risk factors for osteoarthritis include raised BMI and female gender. Whether these two factors influenced synovial gene expression was investigated using a triangulation and modelling strategy which generated 12 datasets of gene expression in synovial tissue from three knee pathologies with matching BMI groups, obese and overweight, and gender distributions. Methodology. Intra-operative synovial biopsies were immersed in RNAlater at 4oC before storage at -80oC. Total RNA was extracted using RNAeasy with gDNA removal. Following RT- PCR and quality assessment, cDNA was applied to Affymetrix Clariom D microarray gene chips. Bioinformatics analyses were performed. Linear models were prepared in limma with gender and BMI factors incorporated sequentially for each pathology comparison, generating 12 models of probes differentially expressed at FDR p<0.05 and Bayes number, B>0. Data analysis of differently expressed genes utilized Ingenuity Pathway Analysis and Cytoscape with Cluego and Cytohubba plug-ins. Results. Expression of 453 synovial genes was influenced by BMI and gender, 360 encode proteins such as HIF-1a, HSF1, HSPA4, HSPA5. Top canonical pathways include Unfolded protein response, Protein Ubiquiitation and Clathrin mediated endocytosis signalling linked by modulation of heat shock proteins, comparable to pathology dependent regulation. In addition BMI and gender modulate gene expression in the NRF2-mediated oxidative stress response pathway with down regulation of Glutathione-S-transferases potentially down regulating antioxidant defences. Conclusion. The enhanced risk of osteoarthritis induced by an elevated BMI and female gender maybe include differential expression of heat shock proteins and genes in the NRF2 pathway


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 84 - 84
1 Jul 2022
Rahman A Dangas K Mellon S Murray D
Full Access

Abstract. Introduction. After remodelling, loss of bone density beside the keel of cementless UKR tibial components has been observed as a potential cause of concern. How this affects patient-reported outcomes, and further clinical implications, is unclear. This study aims to assess the effect of cementless UKR implantation on tibial bone density, and to explore its relationship to patient demographics and outcomes. Method. This prospective study assesses 115 anterior-posterior radiographs from cementless UKR postoperatively and five years after surgery. Grey values from nine regions around each keel were collected and standardised to enable inter-radiograph comparison. Change between the post-operative and 5-year radiographs (indicating bone density) was calculated, and effect on 5-year patient demographics and pain and functional outcomes was assessed. Repeat measurements were performed by two operators to assess reliability. Results. There was excellent inter-operator correlation. There was increased bone density directly below the keel (9.1% vs 3.3%: p<0.0001), and reduced density beside the keel (−5.9% vs -1.0%, p<0.0001); comparisons to adjacent regions. Overall remodelling was significantly greater in smaller tibias (p=0.006), and females (p=0.01). Remodelling was unrelated to outcomes (OKS, ICOAP-A/B, TAS), age, and BMI. Conclusion. Remodelling patterns suggest increased loading below and decreased loading adjacent to the tibial keel. Remodelling is greater in smaller tibias and females. Remodelling is not related to any patient-reported pain or function five years after surgery, suggesting that remodelling is successful in removing any mechanical source of bone pain. Therefore, clinicians viewing such remodelling patterns can ignore them as they are of no consequence


Bone & Joint Open
Vol. 4, Issue 3 | Pages 210 - 218
28 Mar 2023
Searle HKC Rahman A Desai AP Mellon SJ Murray DW

Aims. To assess the incidence of radiological lateral osteoarthritis (OA) at 15 years after medial unicompartmental knee arthroplasty (UKA) and assess the relationship of lateral OA with symptoms and patient characteristics. Methods. Cemented Phase 3 medial Oxford UKA implanted by two surgeons since 1998 for the recommended indications were prospectively followed. A 15-year cumulative revision rate for lateral OA of 5% for this series was previously reported. A total of 163 unrevised knees with 15-year (SD 1) anterior-posterior knee radiographs were studied. Lateral joint space width (JSW. L. ) was measured and severity of lateral OA was classified as: nil/mild, moderate, and severe. Preoperative and 15-year Oxford Knee Scores (OKS) and American Knee Society Scores were determined. The effect of age, sex, BMI, and intraoperative findings was analyzed. Statistical analysis included one-way analysis of variance and Kruskal-Wallis H test, with significance set at 5%. Results. The mean age was 80.6 years (SD 8.3), with 84 females and 79 males. The mean JSW. L. was 5.6 mm (SD 1.4), and was not significantly related to age, sex, or intraoperative findings. Those with BMI > 40 kg/m. 2. had a smaller JSW. L. than those with a ‘normal’ BMI (p = 0.039). The incidence of severe and moderate lateral OA were both 4.9%. Overall, 2/142 (1.4%) of those with nil/mild lateral OA, 1/8 (13%) with moderate, and 2/8 (25%) with severe subsequently had a revision. Those with severe (mean OKS 35.6 (SD 9.3)) and moderate OA (mean OKS 35.8 (SD 10.5)) tended to have worse outcome scores than those with nil/mild (mean OKS 39.5 (SD 9.2)) but the difference was only significant for OKS-Function (p = 0.044). Conclusion. This study showed that the rate of having severe or moderate radiological lateral OA at 15 years after medial UKA was low (both 4.9%). Although patients with severe or moderate lateral OA had a lower OKS than those with nil/mild OA, their mean scores (OKS 36) would be classified as good. Cite this article: Bone Jt Open 2023;4(3):210–218


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 365 - 372
15 Mar 2023
Yapp LZ Scott CEH MacDonald DJ Howie CR Simpson AHRW Clement ND

Aims. This study investigates whether primary knee arthroplasty (KA) restores health-related quality of life (HRQoL) to levels expected in the general population. Methods. This retrospective case-control study compared HRQoL data from two sources: patients undergoing primary KA in a university-teaching hospital (2013 to 2019), and the Health Survey for England (HSE; 2010 to 2012). Patient-level data from the HSE were used to represent the general population. Propensity score matching was used to balance covariates and facilitate group comparisons. A propensity score was estimated using logistic regression based upon the covariates sex, age, and BMI. Two matched cohorts with 3,029 patients each were obtained for the adjusted analyses (median age 70.3 (interquartile range (IQR) 64 to 77); number of female patients 3,233 (53.4%); median BMI 29.7 kg/m. 2. (IQR 26.5 to 33.7)). HRQoL was measured using the three-level version of the EuroQol five-dimension questionnaire (EQ-5D-3L), and summarized using the Index and EuroQol visual analogue scale (EQ-VAS) scores. Results. Patients awaiting KA had significantly lower EQ-5D-3L Index scores than the general population (median 0.620 (IQR 0.16 to 0.69) vs median 0.796 (IQR 0.69 to 1.00); p < 0.001). By one year postoperatively, the median EQ-5D-3L Index score improved significantly in the KA cohort (mean change 0.32 (SD 0.33); p < 0.001), and demonstrated no clinically relevant differences when compared to the general population (median 0.796 (IQR 0.69 to 1.00) vs median 0.796 (IQR 0.69 to 1.00)). Compared to the general population cohort, the postoperative EQ-VAS was significantly higher in the KA cohort (p < 0.001). Subgroup comparisons demonstrated that older age groups had statistically better EQ-VAS scores than matched peers in the general population. Conclusion. Patients awaiting KA for osteoarthritis had significantly poorer HRQoL than the general population. However, within one year of surgery, primary KA restored HRQoL to levels expected for the patient’s age-, BMI-, and sex-matched peers. Cite this article: Bone Joint J 2023;105-B(4):365–372


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 47 - 55
1 Jan 2023
Clement ND Avery P Mason J Baker PN Deehan DJ

Aims. The aim of this study was to identify variables associated with time to revision, demographic details associated with revision indication, and type of prosthesis employed, and to describe the survival of hinge knee arthroplasty (HKA) when used for first-time knee revision surgery and factors that were associated with re-revision. Methods. Patient demographic details, BMI, American Society of Anesthesiologists (ASA) grade, indication for revision, surgical approach, surgeon grade, implant type (fixed and rotating), time of revision from primary implantation, and re-revision if undertaken were obtained from the National Joint Registry data for England, Wales, Northern Ireland, and the Isle of Man over an 18-year period (2003 to 2021). Results. There were 3,855 patient episodes analyzed with a median age of 73 years (interquartile range (IQR) 66 to 80), and the majority were female (n = 2,480, 64.3%). The median time to revision from primary knee arthroplasty was 1,219 days (IQR 579 to 2,422). Younger age (p < 0.001), decreasing ASA grade (p < 0.001), and indications for revision of sepsis (p < 0.001), unexplained pain (p < 0.001), non-polyethylene wear (p < 0.001), and malalignment (p < 0.001) were all associated with an earlier time to revision from primary implantation. The median follow-up was 4.56 years (range 0.00 to 17.52), during which there were 410 re-revisions. The overall unadjusted probability of re-revision for all revision HKAs at one, five, and ten years after surgery were 2.7% (95% confidence interval (CI) 2.2 to 3.3), 10.7% (95% CI 9.6 to 11.9), and 16.2% (95% CI 14.5 to 17.9), respectively. Male sex (p < 0.001), younger age (p < 0.001), revision for septic indications (p < 0.001) or implant fracture (p = 0.010), a fixed hinge (p < 0.001), or surgery performed by a non-consultant grade (p = 0.023) were independently associated with an increased risk of re-revision. Conclusion. There were several factors associated with time to first revision. The re-revision rate was 16.2% at ten years; however, the risk factors associated with an increased risk of re-revision could be used to counsel patients regarding their outcome. Cite this article: Bone Joint J 2023;105-B(1):47–55


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1126 - 1131
1 Oct 2022
Hannon CP Kruckeberg BM Pagnano MW Berry DJ Hanssen AD Abdel MP

Aims. We have previously reported the mid-term outcomes of revision total knee arthroplasty (TKA) for flexion instability. At a mean of four years, there were no re-revisions for instability. The aim of this study was to report the implant survivorship and clinical and radiological outcomes of the same cohort of of patients at a mean follow-up of ten years. Methods. The original publication included 60 revision TKAs in 60 patients which were undertaken between 2000 and 2010. The mean age of the patients at the time of revision TKA was 65 years, and 33 (55%) were female. Since that time, 21 patients died, leaving 39 patients (65%) available for analysis. The cumulative incidence of any re-revision with death as a competing risk was calculated. Knee Society Scores (KSSs) were also recorded, and updated radiographs were reviewed. Results. The cumulative incidence of any re-revision was 13% at a mean of ten years. At the most recent-follow-up, eight TKAs had been re-revised: three for recurrent flexion instability (two fully revised to varus-valgus constrained implants (VVCs), and one posterior-stabilized (PS) implant converted to VVC, one for global instability (PS to VVC), two for aseptic loosening of the femoral component, and two for periprosthetic joint infection). The ten-year cumulative incidence of any re-revision for instability was 7%. The median KSS improved significantly from 45 (interquartile range (IQR) 40 to 50) preoperatively to 70 (IQR 45 to 80) at a mean follow-up of ten years (p = 0.031). Radiologically, two patients, who had not undergone revision, had evidence of loosening (one tibial and one patellar). The remaining components were well fixed. Conclusion. We found fair functional outcomes and implant survivorship at a mean of ten years after revision TKA for flexion instability with a PS implant. Recurrent instability and aseptic loosening were the most common indications for re-revision. Components with increased constraint, such as a VVC or hinged, should be used in these patients in order to reduce the risk of recurrent instability. Cite this article: Bone Joint J 2022;104-B(10):1126–1131


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods. This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m. 2. (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results. Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion. This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants. Cite this article: Bone Joint J 2024;106-B(8):808–816