Advertisement for orthosearch.org.uk
Results 1 - 20 of 119
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 657 - 662
1 Jun 2022
Barlow T Coco V Shivji F Grassi A Asplin L Thompson P Metcalfe A Zaffagnini S Spalding T

Aims. Meniscal allograft transplantation (MAT) for patients with symptomatic meniscal loss has demonstrated good clinical results and survivorship. Factors that affect both functional outcome and survivorship have been reported in the literature. These are typically single-centre case series with relatively small numbers and conflicting results. Our aim was to describe an international, two-centre case series, and identify factors that affect both functional outcome and survival. Methods. We report factors that affect outcome on 526 patients undergoing MAT across two sites (one in the UK and one in Italy). Outcomes of interest were the Knee injury and Osteoarthritis Outcome Score four (KOOS4) at two years and failure rates. We performed multiple regression analysis to examine for factors affecting KOOS, and Cox proportional hazards models for survivorship. Results. Our results indicate that baseline KOOS4 score affects functional outcome at two years, but no other included factors were significantly related to functional outcome. The only factor that affected failure rate was the presence of cartilage lesions down to bone on both the femur and tibia, decreasing the five-year survivorship from 95% (95% confidence interval (CI) 91 to 99) to 84% (95% CI 74 to 94). Conclusion. To our knowledge, this is the largest international cohort reporting on MAT. Our results indicate that factors such as age, BMI, and cartilage lesions down to bone on both the femur and tibia of the affected compartment should not present barriers to offering MAT. Baseline KOOS4 score and the presence of bone-on-bone arthritis can be used to help counsel patients regarding the expected risks and rewards of surgery. Cite this article: Bone Joint J 2022;104-B(6):657–662


Bone & Joint Open
Vol. 4, Issue 10 | Pages 776 - 781
16 Oct 2023
Matar HE Bloch BV James PJ

Aims. The aim of this study was to evaluate medium- to long-term outcomes and complications of the Stanmore Modular Individualised Lower Extremity System (SMILES) rotating hinge implant in revision total knee arthroplasty (rTKA) at a tertiary unit. It is hypothesized that this fully cemented construct leads to satisfactory clinical outcomes. Methods. A retrospective consecutive study of all patients who underwent a rTKA using the fully cemented SMILES rotating hinge prosthesis between 2005 to 2018. Outcome measures included aseptic loosening, reoperations, revision for any cause, complications, and survivorship. Patients and implant survivorship data were identified through both prospectively collected local hospital electronic databases and linked data from the National Joint Registry/NHS Personal Demographic Service. Kaplan-Meier survival analysis was used at ten years. Results. Overall, 69 consecutive patients (69 knees) were included with a median age of 78 years (interquartile range 69 to 84), and there were 46 females (66.7%). Indications were septic revisions in 26 (37.7%), and aseptic aetiology in the remining 43 (62.3%). The mean follow-up was 9.7 years (4 to 18), and the overall complication was rate was 7.24%, all with patellofemoral complications. Failure rate with ‘any cause revision’ was 5.8%. There was one case of aseptic loosening of the femoral component. At ten years, 17/69 patients (24.63%) had died, and implant survivorship was 92.2%. Conclusion. In our experience, the SMILES rotating hinge prosthesis achieves satisfactory long-term outcomes with ten-year implant survivorship of 92.2% and a patellofemoral complication rate of 7.24%. Cite this article: Bone Jt Open 2023;4(10):776–781


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1067 - 1073
1 Oct 2024
Lodge CJ Adlan A Nandra RS Kaur J Jeys L Stevenson JD

Aims. Periprosthetic joint infection (PJI) is a challenging complication of any arthroplasty procedure. We reviewed our use of static antibiotic-loaded cement spacers (ABLCSs) for staged management of PJI where segmental bone loss, ligamentous instability, or soft-tissue defects necessitate a static construct. We reviewed factors contributing to their failure and techniques to avoid these complications when using ABLCSs in this context. Methods. A retrospective analysis was conducted of 94 patients undergoing first-stage revision of an infected knee prosthesis between September 2007 and January 2020 at a single institution. Radiographs and clinical records were used to assess and classify the incidence and causes of static spacer failure. Of the 94 cases, there were 19 primary total knee arthroplasties (TKAs), ten revision TKAs (varus-valgus constraint), 20 hinged TKAs, one arthrodesis (nail), one failed spacer (performed elsewhere), 21 distal femoral endoprosthetic arthroplasties, and 22 proximal tibial arthroplasties. Results. A total of 35/94 patients (37.2%) had spacer-related complications, of which 26/35 complications (74.3%) were because of mechanical failure of the spacer construct, while 9/35 (25.7%) were due to recurrence of infection. Risk factors for internal failure were a construct where the total intramedullary spacer length was less than twice the length of the central osseous defect (p = 0.009), where proximal or distal intraosseous spacer contact was < 10%, and after tibial tubercle osteotomy (p = 0.005). The incidence of spacer complications significantly increased the time to second stage: mean 157 days (42 to 458) in those without complications versus 227 days (11 to 528) with complications (p = 0.014). Conclusion. The failure rate of static antibiotic-loaded cement spacers is much higher than anticipated. Complications of the spacer significantly increased the time to second-stage revision. The risk of mechanical failure is significantly increased if the spacer is less than double the size of the segmental defect, or if inadequate reinforcement is inserted into the residual bone. These findings serve as a guide for surgeons to avoid mechanical complications with static spacers. Cite this article: Bone Joint J 2024;106-B(10):1067–1073


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1279 - 1285
1 Dec 2023
Baker JF Nadar AC Jouflas AC Smith LS Sachdeva S Yakkanti MR Malkani AL

Aims. The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods. This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m. 2. (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results. A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion. The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years. Cite this article: Bone Joint J 2023;105-B(12):1279–1285


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 47 - 47
7 Aug 2023
Reason L Jonas S Evans JT Eyres KS Toms AD Kalson NS Phillips JR
Full Access

Abstract. Introduction. Choosing a hinged implant in the revision knee arthroplasty (rTKA) setting is challenging and limited data on implant performance exists. We present the survivorship and reason for failure in rTKA performed at our institution using the LINK hinge prosthesis, predominantly the cemented modular Endo-Model prosthesis. Methodology. 260 consecutive revision knee cases performed between 2012 and 2020 were reviewed retrospectively. Mean follow up was 27 months (range 0 to 107). Survivorship was analysed in Stata using a Log Rank test to compare performance in patients stratified according to age (≥80 years old (76 cases), 70–79 years (104 cases) and ≤70 years (80 cases). Results. 53 patients died and 48/207 (23%) cases in 40 patients underwent re-revision. Reasons for re-revision were aseptic loosening (21), infection (12), instability (4), extensor failure (1), stiffness (1), fracture (1) and other (8). Loosening was seen in the femur (8), tibia (5), and both the femur and tibia (8). Sub-group analysis of patients according to age showed a significantly higher failure rate in younger patients (6 failures (8%) in patients ≥80, 27 failures (26%) in 70–79 and 15 (19%) in ≤70 (p = 0.02). Failure in patients ≤70 was predominantly due to aseptic loosening (8/15). Conclusion. Here we report a significantly higher rate of LINK hinge prostheses failure in patients <70 undergoing rTKA. Consent should consider the risk of re-revision in this patient group


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 18 - 18
7 Aug 2023
Joseph V Boktor J Bajada S Coupe B
Full Access

Abstract. Introduction. Secondary osteonecrosis of the knee affects young population and causes bilateral extensive lesions. Arthroplasty is the last resort in younger population and joint preserving options questionable in pathological bone. Conservative measures have shown failure in multiple studies and hence no gold standard treatment advocated. We aimed at identifying and analysing various treatment options for secondary osteonecrosis with respect to the outcomes and studying features of symptomatic secondary osteonecrosis with regards to demographic pattern, radiological features and causative factors. Methods. A systematic review of literature was performed in accordance with the Cochrane handbook for systematic reviews and reported according to the PRISMA guidelines. Results. Six studies which included a total of 192 patients with data on 240 knee joints were included in the final review. Follow up period ranged from 1 year to 16 years. The mean age of the patients was 34.7. 3 studies were on arthroplasty and 3 on joint preserving interventions. Majority of patients were in Stage 2 or Stage 4 of osteonecrosis. Steroid induced osteonecrosis was the majority followed by SLE and sickle cell disease. The pooled analysis showed an improvement of pre-operative knee score from 50.47 to 89.21 post-operatively. The pooled effect size for failure rate was 8.7% in joint preserving interventions and 9.2% in joint replacement group. Conclusion. Joint preserving techniques with bone marrow aspirate infiltration showed promising functional outcome and to a certain extent reversal of the pathological process. For advanced stages with subchondral collapse cemented arthroplasty showed satisfactory functional outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 75 - 75
7 Aug 2023
Mackay N Bausch N McGoldrick N Krishnan H Shah F Smith N Thompson P Metcalfe A Spalding T
Full Access

Abstract. Background. Osteochondral allograft (OCA) transplantation is a clinically and cost-effective option for symptomatic cartilage defects. In 2017 we initiated a program for OCA transplantation for complex chondral and osteochondral defects as a UK tertiary referral centre. Aim. To characterise the complications, re-operation rate, graft survivorship and clinical outcomes of knee OCA transplantation. Methodology. Analysis of a prospectively maintained database of patients treated with primary OCA transplantation from 2017 to 2021 with a minimum of one-year follow-up. Patient reported outcome measures (PROMs), complications, re-operations and failures were evaluated. Results. 37 patients with 37 knee OCA procedures were included (mean age 31.6 years [16–49 years]). Mean BMI 26.6 kg/m2 (19.1–35.9 kg/m2). The mean chondral defect size was 3cm2 (1.2–7.3 cm2). Mean duration of follow-up was 3.1 years (1–5.3 years). 16 patients underwent meniscal allograft transplantation (MAT), 6 underwent osteotomy and 4 underwent ligament reconstruction as concurrent procedures. Significant improvements in mean PROMs were noted at 12 months. 16 patients had reoperations of which 5 had more than one surgery. Of these patients 6 were related to OCA (mainly debridement and revision OCA in one patient), and the remainder were related to additional procedures including removal of plate in 2 patients. The overall failure rate was 1 in 37 patients (3%). Conclusions. Early experience of OCA as a treatment option for complex chondral and osteochondral lesions in the knee shows satisfactory results. The reoperation rate is high but at mean follow-up of 3.1 years the survival rate was 97%


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 31 - 31
7 Aug 2023
Myatt D Marshall M Ankers T Robb C
Full Access

Abstract. Unicompartment knee replacement (UKR) has been an effective treatment of isolated medial compartment osteoarthritis (OA). There has been several studies which suggest that patellofemoral (PFJ) wear may not be a relative contraindication for UKR with no statistical difference in failure rates. There is currently conflicting evidence on the role of BMI. We will review if BMI and PFJ wear impacts on the post operative functional scores following UKR. A retrospective review of a prospectively collected database was performed. Data was collected between 26/6/2014 and 25/8/2022. 159 UKR procedures were identified. BMI and PFJ cartilage wear were collected. Oxford knee scores (OKS) were collected at > 2 years. PFJ wear was split into International Cartilage Research Society (ICRS) grades I&II and III&IV. 159 UKR procedures were identified, of these 115 had 2 year follow up. There were 77 who had OKS recorded at 2 years. For PFJ wear there was no statistical difference in the median OKS at 2 years 45 vs 43.5 (p=0.408). Assessing the BMI the median was 29kg/m. 2. , range 20–43kg/m. 2. Spearman's rank was performed to assess the correlation between BMI and >2 year OKS, this demonstrated a moderately negative correlation p(df)=−0.339 (CI 95% −0.538, −0.104) p=0.004. There is no statistically significant difference in >2 year OKS following UKR regardless of PFJ wear. There is a moderately negative correlation between BMI and >2 year OKS which was significant p=0.004. Therefore BMI is a more important consideration when counselling patients for UKR


Abstract. INTRODUCTION. The anatomic distal femoral locking plate (DF-LCP) has simplified the management of supracondylar femoral fractures with stable knee prostheses. Osteoporosis and comminution seem manageable, but at times, the construct does not permit early mobilization. Considerable soft tissue stripping during open reduction and internal fixation (ORIF) may delay union. Biological plating offsets this disadvantage, minimizing morbidity. Materials. Thirty comminuted periprosthetic supracondylar fractures were operated from October 2010 to August 2016. Fifteen (group A) were treated with ORIF, and fifteen (group B) with closed (biological) plating using the anatomical DF-LCP. Post-operatively, standard rehabilitation protocol was followed in all, with hinged-knee-brace supported physiotherapy. Clinico-radiological follow-up was done at 3 months, 6 months, and then yearly (average duration, 30 months), and time to union, complications, failure rates and function were evaluated. Results. Average time to union was 4.5 months (range, 3–6 months) in group A, and 3.5 months (range, 2.5–5 months) in group B. Primary bone grafting was done in twelve patients (all group A). At final follow-up, all fractures had healed, and all (but two) patients were walking unsupported, with no pain or deformity, with average knee range of motion (ROM) of 90° (range, 55 to 100°). Two patients had superficial infection (group A), two had knee stiffness (group A), one had shortening of 1.5cm (group B) and one had valgus malalignment of 10 degrees (group B). Conclusion. Biological plating in comminuted supracondylar fractures about stable TKA prostheses is an excellent option, may obviate need for bone grafting, and reducing complications


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 76 - 76
1 Jul 2022
Borque K Jones M Laughlin M Webster E Williams A
Full Access

Abstract. Introduction. The popularity of all-inside meniscal repair devices has led to a shift away from inside-out meniscus repair without comparative studies to support the change. The aim of this study was to compare the failure rate and time to failure of all-inside and inside-out meniscus repair performed in elite athletes. Methodology. A retrospective review was performed of all elite athletes who underwent meniscal repair, with a minimum of two-year follow-up between 2013 and 2019. Repairs were classified as all-inside or inside-out according to the repair technique. Failure was defined as undergoing a subsequent surgery to address a persistent meniscal tear. Results. 192 (135 lateral and 57 medial) meniscal repairs in elite athletes were included and 41 (21%) failed. Medial meniscus tears repaired with the all-inside technique failed at a significantly higher rate (58%) than medial meniscus tears repaired with the inside-out (23%) or lateral meniscus tears repaired with the all-inside (12%) or inside-out (14%) technique (p<.001). At 1 year following repair, 8% of lateral meniscus repairs had failed regardless of technique. Medial meniscus repairs failed at an approximate rate of 15% for inside-out technique and 42% for all-inside technique. By 2 years, approximately 54% of all-inside medial meniscus repairs had failed and by 5 years over 60% of repairs had failed. Conclusion. All-inside medial meniscal repair led to a higher rate of failure compared to inside-out medial or lateral meniscus repair in elite athletes. Medial meniscus repairs failed at a high rate than lateral meniscal repairs


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 97 - 97
1 Jul 2022
Khalefa MA Aujla R Aslam N D'Alessandro P Malik SS
Full Access

Abstract. Introduction. Anterior cruciate ligament reconstruction (ACLR) can be performed with a number of different autografts including all soft tissue quadriceps autograft. (QT). QT has several advantages including decreased donor site morbidity, reduced anterior knee pain and comparable revision rates compared to other autografts. The primary aim of this review was to assess all complications of QT in adult population. Methodology. A systematic review of the literature was conducted on in accordance with the PRISMA guidelines using the online databases Medline and EMBASE. Clinical studies or reporting on soft tissue QT were included and appraised using the Methodological Index for Non-Randomized Studies (MINORS) tool. Results. Twelve studies were eligible, giving a total of 774 cases of QT ACLR. The mean age ranged from 18 to 45 years. The mean follow-up ranged from 12 to 55.6 months. Nine studies report on patients’ functional outcomes with mean IKDC score was 90.9 ±22.6 and Lysholm score of 88.6 ±6.5. Seven studies reported on complications which was overall 12.3% including 4.1% for graft site morbidity. Infection was reported in 0.4% of the patients. Seven studies reported on failure rate which was reported in 5.3%. Re-operation rate for any reason was 3.2 %. Conclusion. All soft tissue QT for ACLR has a low complication rate and revision rate. There is less graft site morbidity


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 1 - 1
1 Jul 2022
Clarke H Antonios J Bozic K Spangehl M Bingham J Schwartz A
Full Access

Abstract. Introduction. Periprosthetic joint infection (PJI) is a common cause of revision total knee surgery. Although debridement and implant retention (DAIR) has lower success rates in the chronic setting, it is an accepted treatment for acute PJI. There are two broad DAIR strategies: single debridement or a planned double debridement performed days apart. The purpose of this study is to evaluate the cost-effectiveness of single versus double DAIR with antibiotic beads for acute PJI in total knee arthroplasty (TKA). Methodology. A decision tree using single or double DAIR as treatment strategies for acute PJI was constructed. Quality Adjusted Life Years (QALYs) and costs associated with the two treatment arms were calculated. Treatment success rates, failure rates, and mortality rates were derived from the literature. Medical costs were derived from both the literature and Medicare data. A cost-effectiveness plane was constructed from multiple Monte Carlo trials. A sensitivity analysis identified parameters most influencing the optimal strategy decision. Results. Double DAIR with antibiotic beads was the optimal treatment strategy both in terms of the health utility state (82% of trials), and medical cost (97% of trials). Strategy tables demonstrated that as long as the success rate of double debridement is 10% or greater than the success rate of a single debridement, the two-stage protocol is cost-effective. Conclusions. This Markov analysis demonstrates that in the setting of acute PJI following TKA, a double DAIR with antibiotic beads is more cost effective than single DAIR from a societal perspective


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 30 - 30
1 Jul 2022
Middleton R Jackson W Alvand A Bottomley N Price A
Full Access

Abstract. Background. Since 2012 we have routinely used the cementless Oxford medial unicompartmental knee arthroplasty (mUKA), with microplasty instrumentation, in patients with anteromedial osteoarthritis (AMOA) meeting modern indications. We report the 10-year survival of 1000 mUKA with minimum 4-year follow-up. Methods. National Joint Registry (NJR) surgeon reports were interrogated for each senior author to identify the first 1,000 mUKAs performed for osteoarthritis. A minimum of 4 years follow-up was required. There was no loss to follow-up. The NJR status of each knee was established. For each mUKA revision the indication and mechanism of failure was determined using local patient records. The 10-year implant survival was calculated using life-table analysis. Results. The 1,000 mUKA cohort represented 55% of all primary knee replacements in the period, with an average age of 67.7 years and a 54%/46% male/female split. There were 17 revisions (11 for arthritis progression, 4 infections, 1 dislocation and 1 aseptic loosening). The 10-year survival was 98% (44 at risk in 10th year). One patient sustained a periprosthetic fracture at 3 weeks, treated with buttress plate fixation. Discussion. This is the first detailed series reporting the long-term outcome of the cementless Oxford mUKA implanted using microplasty instrumentation. There was a low failure rate, with only one revision for aseptic loosening. Lateral progression was the commonest cause for revision, with an incidence of 1%. This report provides evidence that the combination of evidence-based indications, well-designed instrumentation and cementless fixation can provide excellent long-term survival for the Oxford mUKA in treating AMOA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 46 - 46
1 Jul 2022
Soumpasis K Duncan K Wilson AJ Risebury MJ Yasen SK
Full Access

Abstract. Introduction. We present a case series of patients that underwent knee ligament reconstruction with graft reinforcement using FibreTape (Arthrex), a 2mm wide non-biodegradable polyethylene tape. Outcomes and safety of this novel technique are reported. Methods. Data were collected from a prospectively maintained database from 03/2011 to 11/2019. All skeletally mature patients that underwent reinforced knee ligament reconstruction surgery at Basingstoke and North Hampshire Hospital were included. The cohort was interrogated for outcomes including failure, complications, and subjective patient reported outcomes at 6,12 and 24 months postoperatively. Results. 438 patients were eligible. The mean age was 33.4 years and 68% of them were males. This included 171 ACL reconstructions, 96 ACL with anterolatreal ligament reconstructions, 59 bicruciate reconstructions, 30 ACL with posterolateral corner, 49 posterior cruciate ligament with one other ligament and 33 other ligament reconstruction. Allograft was used for 125 patients. 338 cases related to primary reconstruction. The overall complication rate was 5.3%, with a 2.1% re-rupture rate. There were 9 patients with a re-rupture and 5 of them had undergone multiligament reconstruction. We found a statistically significant improvement in all subjective scoring indices post-operatively up to 2 years. There were no complications directly related to the use of ligament reinforcement. Conclusion. Graft reinforcement is a safe option in the management of knee ligament injuries. Encouraging results were observed in patient reported outcomes. Reinforcement is technically reproducible and may represent an answer for graft failure rates, especially in multiligament reconstructions. Further application and evaluation is necessary to confirm its benefit


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 5 - 5
1 Oct 2020
Zamora T Garbuz DS Greidanus NV Masri BA
Full Access

Introduction. Our objective is to describe early and midterm results with the use of a new knee prosthesis as an articulating spacer in planned two-stage management for infected total knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a completed 2-stage revision. Methods. Forty-seven patients (48 knees) from January 2012 and November 2017 underwent a 2-stage exchange with an articulating spacer with new implants was used for a chronic knee periprosthetic joint infection with a mean follow-up of 3.7 years (2–6.5 years). The most frequently identified infecting organism was MSSA (31%), MRSA (21%) or MRSE (20%). At the first stage, a new PS femoral component and a new all-polyethylene posterior stabilized (PS) tibial component or a standard PS tibial liner were cemented with antibiotic-cement, typically 3.6 gm tobramycin and vancomycin 1.5 gm. IV antibiotics for six weeks were administered. The planned reimplantation was at 3 months, but ninetteen spacers (14 all poly tibias and 5 tibial liner) were retained for over 12 months. Postoperative assessment included knee range of motion (ROM), quality of life (QOL) scores (SF-12, WOMAC, KOOS, Oxford, and UCLA scores), and a satisfaction scale from 0–100%. Results. Of the 48 knees, 8 failed due to lack of infection control, and 2 died within the first year for medical reasons (4%), giving a failure rate of 17% (8/46). One of these knees was not revised due to poor medical status. Of the remaining 7, 2 had a repeat 2-stage exchange, one a single stage revision and 4 irrigation and debridement with retained implants. All 7 had a successful outcome with infection control after this, leaving a permanent failure rate of 2% (1/46). Five of the 19 knees with initially retained implants were revised to a second stage after 12 months for continued pain or instability (1/14 all poly tibia and 4/5 PS liner). There were no significant differences in final range of motion or QOL scores between patients with a retained first stage procedure and those who underwent a second stage operation. Also, there was no statistically significant difference in the initial failure rate due to infection between patients with a complete 2-stage revision and those with a retained first stage (19% (6/31) vs. 14% (2/14), respectively; p=0.613). Conclusions. When an all poly tibial implant is used a spacer in two-stage exchange arthroplasty, it may be retained for over 12 months, with no difference in infection control, range of motion, and quality of life assessment to patients with complete 2-stage revision surgery. With this technique, the second stage may be delayed in patients who are doing well, and may never need to be revised, hence we propose the new term “one-and-a-half stage exchange”


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 635 - 640
1 Jun 2023
Karczewski D Siljander MP Larson DR Taunton MJ Lewallen DG Abdel MP

Aims. Knowledge on total knee arthroplasties (TKAs) in patients with a history of poliomyelitis is limited. This study compared implant survivorship and clinical outcomes among affected and unaffected limbs in patients with sequelae of poliomyelitis undergoing TKAs. Methods. A retrospective review of our total joint registry identified 94 patients with post-polio syndrome undergoing 116 primary TKAs between January 2000 and December 2019. The mean age was 70 years (33 to 86) with 56% males (n = 65) and a mean BMI of 31 kg/m. 2. (18 to 49). Rotating hinge TKAs were used in 14 of 63 affected limbs (22%), but not in any of the 53 unaffected limbs. Kaplan-Meier survivorship analyses were completed. The mean follow-up was eight years (2 to 19). Results. The ten-year survivorship free from revision was 91% (95% confidence interval (CI) 81 to 100) in affected and 84% (95% CI 68 to 100) in unaffected limbs. There were six revisions in affected limbs: three for periprosthetic femoral fractures and one each for periprosthetic joint infection (PJI), patellar clunk syndrome, and instability. Unaffected limbs were revised in four cases: two for instability and one each for PJI and tibial component loosening. The ten-year survivorship free from any reoperation was 86% (95% CI 75 to 97) and 80% (95% CI 64 to 99) in affected and unaffected limbs, respectively. There were three additional reoperations among affected and two in unaffected limbs. There were 12 nonoperative complications, including four periprosthetic fractures. Arthrofibrosis occurred in five affected (8%) and two unaffected limbs (4%). Postoperative range of motion decreased with 31% achieving less than 90° knee flexion by five years. Conclusion. TKAs in post-polio patients are complex cases associated with instability, and one in four require constraint on the affected side. Periprosthetic fracture was the main mode of failure. Arthrofibrosis rates were high and twice as frequent in affected limbs. Cite this article: Bone Joint J 2023;105-B(6):635–640


Introduction. Treatment of prosthetic joint infection (PJI) following total knee arthroplasty (TKA) may guided by PJI classification, taking into account infection duration and potential for biofilm formation. Debridement, antibiotics and implant retention (DAIR) is recommended for ‘post-operative’ and ‘acute’ haematogenous PJI. However, the time cut-off for ‘post-operative’ PJI varies across classification systems. Furthermore, poor DAIR success rates have been reported in acute haematogenous PJIs. This study aimed to determine the success of DAIR in a large cohort of PJIs, and assess the utility of current classification systems for predicting DAIR outcomes. Method. In this multicentre retrospective, cohort study, we identified 230 patients undergoing DAIR for first episode PJI following primary TKA. Patient demographics, disease and surgical factors were identified, and PJI subtype, post-operative antibiotic regime and treatment outcomes were recorded. Statistical analysis was performed to identify factors associated with failed DAIR, and success rates were analysed by multiple classification systems using receiver operating characteristic (ROC) curves. Results. At average follow-up of 6.9 years, DAIR failed in 46% of cases. ROC analysis found 3 month and 1 year cut-offs for ‘post-operative’ PJIs were equally predictive of outcomes (AUC=0.63). On multivariate survival analysis, DAIR failed in 63% of late haematogenous PJIs (implant age>1 year) compared to 36% of early (<1year) PJIs (OR=1.78, p=0.01). Staphylococcus aureus (OR=4.70, p<0.001) and gram negative infections (OR=2.56, p=0.031) were risk factors for DAIR failure in late PJIs. Conclusions. We found a high failure rate in late infections following TKA, irrespective of their classification as ‘acute haematogenous’ or ‘chronic’. Higher DAIR success rates were seen with implant age <1year. These findings call into question the utility of current classification systems based on duration of bacterial presence. For late infections (>1year), PJI caused by S. aureus or gram negative bacteria have a higher failure rate when treated with DAIR


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1373 - 1379
1 Aug 2021
Matar HE Bloch BV Snape SE James PJ

Aims. Single-stage revision total knee arthroplasty (rTKA) is gaining popularity in treating chronic periprosthetic joint infections (PJIs). We have introduced this approach to our clinical practice and sought to evaluate rates of reinfection and re-revision, along with predictors of failure of both single- and two-stage rTKA for chronic PJI. Methods. A retrospective comparative cohort study of all rTKAs for chronic PJI between 1 April 2003 and 31 December 2018 was undertaken using prospective databases. Patients with acute infections were excluded; rTKAs were classified as single-stage, stage 1, or stage 2 of two-stage revision. The primary outcome measure was failure to eradicate or recurrent infection. Variables evaluated for failure by regression analysis included age, BMI, American Society of Anesthesiologists grade, infecting organisms, and the presence of a sinus. Patient survivorship was also compared between the groups. Results. A total of 292 consecutive first-time rTKAs for chronic PJI were included: 82 single-stage (28.1%); and 210 two-stage (71.9%) revisions. The mean age was 71 years (27 to 90), with 165 females (57.4%), and a mean BMI of 30.9 kg/m. 2. (20 to 53). Significantly more patients with a known infecting organism were in the single-stage group (93.9% vs 80.47%; p = 0.004). The infecting organism was identified preoperatively in 246 cases (84.2%). At a mean follow-up of 6.3 years (2.0 to 17.6), the failure rate was 6.1% in the single-stage, and 12% in the two-stage groups. All failures occurred within four years of treatment. The presence of a sinus was an independent risk factor for failure (odds ratio (OR) 4.97; 95% confidence interval (CI) 1.593 to 15.505; p = 0.006), as well as age > 80 years (OR 5.962; 95% CI 1.156 to 30.73; p = 0.033). The ten-year patient survivorship rate was 72% in the single-stage group compared with 70.5% in the two-stage group. This difference was not significant (p = 0.517). Conclusion. Single-stage rTKA is an effective strategy with a high success rate comparable to two-stage approach in appropriately selected patients. Cite this article: Bone Joint J 2021;103-B(8):1373–1379


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 852 - 860
1 Jul 2020
Zamora T Garbuz DS Greidanus NV Masri BA

Aims. Our objective is to describe our early and mid-term results with the use of a new simple primary knee prosthesis as an articulating spacer in planned two-stage management for infected knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a complete two-stage revision. Methods. We included 47 patients (48 knees) with positive criteria for infection, with a minimum two-year follow-up, in which a two-stage approach with an articulating spacer with new implants was used. Patients with infection control, and a stable and functional knee were allowed to retain the initial first-stage components. Outcomes recorded included: infection control rate, reoperations, final range of motion (ROM), and quality of life assessment (QoL) including Western Ontario and McMaster Universities osteoarthritis index, Knee Injury and Osteoarthritis Outcome Score, Oxford Knee Score, 12-Item Short-Form Health Survey questionnaire, and University of California Los Angeles (UCLA) activity score and satisfaction score. These outcomes were evaluated and compared to additional cohorts of patients with retained first-stage interventions and those with a complete two-stage revision. Mean follow-up was 3.7 years (2.0 to 6.5). Results. Eight knees failed directly related to lack of infection control (16%), and two patients (two knees) died within the first year for causes not directly related, giving an initial success rate of 79% (38/48). Secondary success rate after a subsequent procedure was 91% (44/48 knees). From the initially retained spacers, four knees (22%) required a second-stage revision for continuous symptoms and one (5%) for an acute infection. There were no significant differences regarding the failure rate due to infection, ROM, and QoL assessment between patients with a retained first-stage procedure and those who underwent a second-stage operation. Conclusion. Our protocol of two-stage exchange for infected knee arthroplasties with an articulating spacer and using new primary knee implants achieves adequate infection control. Retained first-stage operations achieve comparable results in selected cases, with no difference in infection control, ROM, and QoL assessment in comparison to patients with completed two-stage revision surgery. Cite this article: Bone Joint J 2020;102-B(7):852–860


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 62 - 62
1 Oct 2020
Garceau SP Warschawski YS Tang A Sanders EB Schwarzkopf R Backstein D
Full Access

Introduction. The effect of using thicker liners in primary total knee arthroplasty (TKA) on functional outcomes and aseptic failure rates remains largely unknown. As such, we devised a multicenter study to assess both the clinical outcomes and survivorship of thick vs thin liners after primary TKA. Methods. A search of our institutional databases was performed for patients having undergone bilateral (simultaneous or staged) primary TKA with similar preoperative and surgical characteristics between both sides. Two cohorts were created: thick liners and thin liners. Outcomes collected were as follows: change in Knee Society Score (DKSS), change in range of motion, and aseptic revision. Ad hoc power analysis was performed for DKSS (α ¼ 0.05; power ¼ 80%). Differences between cohorts were assessed. Results. 195 TKAs were identified for each cohort. DKSS and change in range of motion in the thin vs thick cohorts were similar: 51.4 vs 51.6 (P ¼ .86) and 11.1 vs 10.0 (P ¼ .66), respectively. No difference in aseptic revision rates were observed between thin and thick cohorts: all cause (4.1%, 3.1%; P ¼ .59), aseptic loosening (0.5%, 0.5%; P ¼ 1.0), instability (0.5%, 0.5%; P ¼ 1.0), all-cause revision for stiffness (3.1%, 2.1%; P ¼ .52), manipulation under anesthesia (2.1%, 2.1%; P ¼ 1.0), and liner exchange (0.5%, 0%; P ¼ .32). Conclusion. The results of this study suggest that both rates of revision surgery and clinical outcomes are similar for TKAs performed with thick and thin liners. Preoperative factors are likely to play an important role in liner thickness selection, and emphasis should be placed on ensuring sound surgical technique