Many different designs of total hip arthroplasty
(THA) with varying performance and cost are available. The identification
of those which are the most cost-effective could allow significant
cost-savings. We used an established Markov model to examine the
cost
The aim of this study was to compare the cost-effectiveness of cemented hemiarthroplasty (HA) versus hydroxyapatite-coated uncemented HA for the treatment of displaced intracapsular hip fractures in older adults. A within-trial economic evaluation was conducted based on data collected from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized controlled trial in the UK. Resource use was measured over 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from the NHS and personal social service perspective. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was represented graphically using confidence ellipses and cost-effectiveness acceptability curves.Aims
Methods
There is little evidence on the cost effectiveness
of different brands of hip prostheses. We compared lifetime cost effectiveness
of frequently used brands within types of prosthesis including cemented
(Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite
Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed)
and hybrid (Exeter V40 Trilogy, Exeter V40 Trident, and CPT Trilogy).
We used data from three linked English national databases to estimate
the lifetime risk of revision, quality-adjusted life years (QALYs)
and cost. . For women with osteoarthritis aged 70 years, the Exeter V40 Elite
Plus Ogee had the lowest risk of revision (5.9% revision risk, 9.0
QALYs) and the CPT Trilogy had the highest QALYs (10.9% revision
risk, 9.3 QALYs). Compared with the Corail Pinnacle (9.3% revision
risk, 9.22 QALYs), the most commonly used brand, and assuming a
willingness-to-pay of £20 000 per QALY gain, the CPT Trilogy is
most cost effective, with an incremental net monetary benefit of £876.
Differences in cost
This trial aims to assess the
We used 99 strains of organisms representative of orthopaedic infections to examine the
We investigated whether blood metal ions could effectively identify bilateral metal-on-metal hip patients at risk of adverse reactions to metal debris (ARMD). This single-centre, prospective study involved 235 patients (185 bilateral Birmingham Hip Resurfacings (BHRs) and 50 bilateral Corail-Pinnacles) undergoing whole blood metal ion sampling (mean time=6.8 years from latest implant to sampling). Patients were divided into ARMD (revised or ARMD on imaging; n=40) and non-ARMD groups (n=195). Metal ion parameters (cobalt; chromium; maximum cobalt or chromium; cobalt-chromium ratio) were compared between groups. Optimal metal ion thresholds for identifying ARMD patients were determined using receiver operating characteristic (ROC) analysis, which compares the performance of different tests using the area under the curve (AUC) (higher AUC=more discriminatory).Introduction
Patients and methods
Recent studies have demonstrated that implant-specific blood metal ion thresholds exist in unilateral and bilateral metal-on-metal (MoM) hip arthroplasty patients, with these thresholds being most effective for identifying patients at low-risk of adverse reactions to metal debris (ARMD). We investigated whether these new blood metal ion thresholds could effectively identify patients at risk of ARMD in an external cohort of MoM hip arthroplasty patients. We performed a validation study involving 803 MoM hip arthroplasties implanted in 710 patients at three European centres (323=unilateral Birmingham Hip Resurfacing (BHR); 93=bilateral BHR; 294=unilateral Corail-Pinnacle). All patients underwent whole blood metal ion sampling. Patients were divided into those with ARMD (revised for ARMD or ARMD on imaging; n=75), and those without ARMD (n=635). Previously devised implant-specific blood metal ion thresholds (cobalt=2.15μg/l for unilateral BHR; maximum cobalt or chromium=5.5μg/l for bilateral BHR; cobalt=3.57μg/l for unilateral Corail-Pinnacle) were applied to the validation cohort, with receiver operating characteristic curve analysis used to establish the discriminatory characteristics for each respective threshold. The area under the curve, sensitivity, specificity, positive predictive value and negative predictive value for distinguishing between patients with and without ARMD for each implant-specific threshold were respectively: unilateral BHR=89.4% (95% CI=82.8%-96.0%), 78.9%, 86.7%, 44.1%, 96.9%; bilateral BHR=89.2% (95% CI=81.3%-97.1%), 70.6%, 86.8%, 54.5%, 93.0%; unilateral Corail-Pinnacle=76.9% (95% CI=63.9%-90.0%), 65.0%, 85.4%, 24.5%, 97.1%. The 7μg/l UK MHRA threshold missed significantly more patients with ARMD compared with the implant-specific thresholds (4.9% vs. 2.8%; p=0.0003). This external multi-centre validation study has confirmed that MoM hip arthroplasty patients with blood metal ion levels below newly devised implant-specific thresholds have a low-risk of ARMD. Compared to implant-specific thresholds, the currently proposed fixed MHRA threshold missed more patients with ARMD. We recommend using implant-specific thresholds over fixed thresholds when managing MoM hip arthroplasty patients.
The objective of this study is to evaluate the
Securing the osteotomized greater trochanter (GT) during total hip arthroplasty (THA) for dislocated dysplastic hips (DDH) poses a significant challenge. This study evaluates the union rate and
Dislocation is still one of the more common reasons for revision of THR.Registry and large institutional data has demonstrated the
In-hospital length of stay (LOS) and discharge disposition following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, we wished to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge disposition following robotic-arm assisted (RO THA) versus conventional technique Total Hip Arthroplasty (CO THA). This large-scale, single institution study included patients of any age undergoing primary THA (N = 1,732) for any cause between May 2019 and January 2023. Data extracted included patient demographics, LOS, need for Post Anaesthesia Care Unit (PACU) admission, anaesthesia type, readmission within 30 days and discharge dispositions. Univariate and multivariate logistic regression models were also employed to identify factors and patient characteristics related to delayed discharge. The median LOS in the RO THA group was 54 hours (34, 78) versus 60 (51, 100) in the CO THA group, p<0.001. Discharge disposition was comparable between the two groups. In the multivariate model, age, need for PACU admission, ASA score > 2, female gender, general anaesthesia and utilisation of the conventional technique were significantly associated with LOS > 2 days. Our study showed that robotic-arm assistance was associated with a shorter LOS in patients undergoing primary THA and no difference in discharge destination. Our results suggest that robotic-arm assistance could be advantageous in partly addressing the upsurge of hip arthroplasty procedures and the concomitant health care burden; however, this needs to be corroborated by long-term cost
MCID and PASS are thresholds driven from PROMS to reflect clinical
As patient data continues to grow, the importance of efficient and precise analysis cannot be overstated. The employment of Generative Artificial Intelligence (AI), specifically Chat GPT-4, in the realm of medical data interpretation has been on the rise. However, its
Preoperative anaemia and intraoperative blood loss result in ∼90% of individuals being anaemic following hip and knee arthroplasty. Reducing blood loss offers the opportunity to improve outcomes and reduce the risk of transfusion and costs. This review's aim was to determine the
The development and implementation of Enhanced Recovery After Surgery (ERAS) protocols are of particular interest in elective orthopaedics due to clinical benefits and cost
Aims. Two-stage exchange revision total hip arthroplasty (THA) performed in case of periprosthetic joint infection (PJI) has been considered for many years as being the gold standard for the treatment of chronic infection. However, over the past decade, there have been concerns about its safety and its
Aims. This study aims to assess the feasibility of conducting a pragmatic, multicentre randomized controlled trial (RCT) to test the clinical and cost-effectiveness of an informal caregiver training programme to support the recovery of people following hip fracture surgery. Methods. This will be a mixed-methods feasibility RCT, recruiting 60 patients following hip fracture surgery and their informal caregivers. Patients will be randomized to usual NHS care, versus usual NHS care plus a caregiver-patient dyad training programme (HIP HELPER). This programme will comprise of three, one-hour, one-to-one training sessions for the patient and caregiver, delivered by a nurse, physiotherapist, or occupational therapist. Training will be delivered in the hospital setting pre-patient discharge. It will include practical skills for rehabilitation such as: transfers and walking; recovery goal setting and expectations; pacing and stress management techniques; and introduction to the HIP HELPER Caregiver Workbook, which provides information on recovery, exercises, worksheets, and goal-setting plans to facilitate a ‘good’ recovery. After discharge, patients and caregivers will be supported in delivering rehabilitation through three telephone coaching sessions. Data, collected at baseline and four months post-randomization, will include: screening logs, intervention logs, fidelity checklists, quality assurance monitoring visit data, and clinical outcomes assessing quality of life, physical, emotional, adverse events, and resource use outcomes. The acceptability of the study intervention and RCT design will be explored through qualitative methods with 20 participants (patients and informal caregivers) and 12 health professionals. Discussion. A multicentre recruitment approach will provide greater external validity across population characteristics in England. The mixed-methods approach will permit in-depth examination of the intervention and trial design parameters. The findings will inform whether and how a definitive trial may be undertaken to test the
The clinical success of THA is accepted, however wide variation in implant usage and outcomes is reported across the world. The Getting It Right First Time initiative in the UK has recommended increased use of cemented constructs in patients over 70. A clear clinical directive has been proposed aiming to reduce revision rates, improve outcomes and increase cost
Aims. Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical
Aims. Although periarticular injection plays an important role in multimodal pain management following total hip arthroplasty (THA), there is no consensus on the optimal composition of the injection. In particular, it is not clear whether the addition of a corticosteroid improves the pain relief achieved nor whether it is associated with more complications than are observed without corticosteroid. The aim of this study was to quantify the safety and