Aims. The aim of this study is to evaluate the surgical treatment with the best healing rate for patients with proximal femoral unicameral bone cysts (UBCs) after initial surgery, and to determine which procedure has the lowest adverse event burden during follow-up. Methods. This multicentre retrospective study was conducted in 20 tertiary paediatric hospitals in France, Belgium, and Switzerland, and included patients aged < 16 years admitted for UBC treatment in the proximal femur from January 1995 to December 2017. UBCs were divided into seven groups based on the index treatment, which included elastic stable intramedullary nail (ESIN) insertion with or without percutaneous injection or grafting, percutaneous injection alone, curettage and grafting alone, and insertion of other orthopaedic hardware with or without curettage. Results. A total of 201 patients were included in the study. The mean age at diagnosis was 8.7 years (SD 3.9); 77% (n = 156) were male. The mean follow-up was 9.4 years (SD 3.9).
Elastic stable intramedullary nailing (ESIN)
is generally acknowledged to be the treatment of choice for displaced diaphyseal
femoral fractures in children over the age of three years, although
complication rates of up to 50% are described. Pre-bending the nails
is recommended, but there are no published data to support this.
Using synthetic bones and a standardised simulated fracture, we
performed biomechanical testing to determine the influence on the
stability of the fracture of pre-bending the nails before implantation.
Standard
Aim. The purpose of this study was to quantify the number of children treated with
End caps are intended to prevent nail migration
(push-out) in elastic stable intramedullary nailing. The aim of
this study was to investigate the force at failure with and without
end caps, and whether different insertion angles of nails and end caps
would alter that force at failure. Simulated oblique fractures of the diaphysis were created in
15 artificial paediatric femurs. Titanium Elastic Nails with end
caps were inserted at angles of 45°, 55° and 65° in five specimens
for each angle to create three study groups. Biomechanical testing
was performed with axial compression until failure. An identical
fracture was created in four small adult cadaveric femurs harvested
from two donors (both female, aged 81 and 85 years, height 149 cm and
156 cm, respectively). All femurs were tested without and subsequently
with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly
different between the three groups (p = 0.613). Push-out force was
significantly higher in the cadaveric specimens with the use of
end caps by an up to sixfold load increase (830 N, standard deviation
(SD) 280 These results indicate that the nail and end cap insertion angle
can be varied within 20° without altering construct stability and
that the risk of elastic stable intramedullary nailing push–out
can be effectively reduced by the use of end caps. Cite this article:
The management of children’s fractures has evolved
as a result of better health education, changes in lifestyle, improved
implant technology and the changing expectations of society. This
review focuses on the changes seen in paediatric fractures, including
epidemiology, the increasing problems of obesity, the mechanisms
of injury, non-accidental injuries and litigation. We also examine
the changes in the management of fractures at three specific sites:
the supracondylar humerus, femoral shaft and forearm. There has
been an increasing trend towards surgical stabilisation of these
fractures. The reasons for this are multifactorial, including societal
expectations of a perfect result and reduced hospital stay. Reduced hospital
stay is beneficial to the social, educational and psychological
needs of the child and beneficial to society as a whole, due to
reduced costs. Cite this article:
We present the results of 90 consecutive children with displaced fractures of the forearm treated by elastic stable intramedullary nailing with a mean follow-up of 6.6 months (2.0 to 17.6). Eight (9%) had open fractures and 77 (86%) had sustained a fracture of both bones. The operations were performed by orthopaedic trainees in 78 patients (86%). All fractures healed at a mean of 2.9 months (1.1 to 8.7). There was one case of delayed union of an ulnar fracture. An excellent or good functional outcome was achieved in 76 patients (84%). There was no statistical difference detected when the grade of operating surgeon, age of the patient and the diaphyseal level of the fracture were correlated with the outcome. A limited open reduction was required in 40 fractures (44%). Complications included seven cases of problematic wounds, two transient palsies of the superficial radial nerve and one case each of malunion and a post-operative compartment syndrome. At final follow-up, all children were pain-free and without limitation of sport and play activities. Our findings indicate that the functional outcome following paediatric fractures of the forearm treated by elastic stable intramedullary nailing is good, without the need for anatomical restoration of the radial bow.
Flexible intramedullary nailing is gaining popularity as an effective method of treating long-bone fractures in children. We retrospectively reviewed the records and radiographs of 56 unstable fractures of the tibia in 54 children treated between March 1997 and May 2005. All were followed up for at least two months after the removal of the nails. Of the 56 tibial fractures, 13 were open. There were no nonunions. The mean time to clinical and radiological union was ten weeks. Complications included residual angulation of the tibia, leg-length discrepancy, deep infection and failures of fixation. All achieved an excellent functional outcome. We conclude that flexible intramedullary fixation is an easy and effective method of management of both open and closed unstable fractures of the tibia in children.
Most surgeons favour removing forearm plates
in children. There is, however, no long-term data regarding the complications
of retaining a plate. We present a prospective case series of 82
paediatric patients who underwent plating of their forearm fracture
over an eight-year period with a minimum follow-up of two years.
The study institution does not routinely remove forearm plates.
A total of 116 plates were used: 79 one-third tubular plates and 37 dynamic
compression plates (DCP). There were 12 complications: six plates
(7.3%) were removed for pain or stiffness and there were six (7.3%)
implant-related fractures. Overall, survival of the plates was 85%
at 10 years. Cox regression analysis identified radial plates (odds
ratio (OR) 4.4, p = 0.03) and DCP fixation (OR 3.2, p = 0.02) to
be independent risk factors of an implant-related fracture. In contrast
ulnar plates were more likely to cause pain or irritation necessitating
removal (OR 5.6, p = 0.04). The complications associated with retaining a plate are different,
but do not occur more frequently than the complications following
removal of a plate in children.