The clinical diagnosis of distal radioulnar joint (DRUJ) instability remains challenging. The current diagnostic gold standard is a dynamic computerized topography (CT) scan. This investigation compares the affected and normal wrists in multiple static positions of forearm rotation.. However, its accuracy has been questioned, as the wrist is unloaded and not placed under stress. This may fail to capture DRUJ instability that does not result in static malalignment between the ulnar head and sigmoid notch. The purpose of this biomechanical study was to evaluate the effectiveness of both dynamic and stress CT scans in detecting DRUJ instability. A customized DRUJ arthrometer was designed that allows for both static positioning, as well as dorsal and volar loading at the DRUJ in various degrees of forearm rotation. Ten fresh frozen cadavers were prepared and mounted in the apparatus. CT scans were performed both in the unloaded condition (dynamic CT) and with each arm subjected to a standardized 50N volar and dorsal force (stress CT) in neutral and maximum pronation/ supination. The TFCC (triangular fibrocartilage complex)was then sectioned peripherally to simulate DRUJ instability and the methodology was repeated. CT scans were then evaluated for displacement using the radioulnar ratio method. When calculating the radioulnar ratio for intact wrists using the
Nearly one quarter of ankle fractures have a recognized syndesmosis injury. An intact syndesmosis ligament complex stabilizes the distal tibio-fibular joint while allowing small, physiologic amounts of relative motion. When injured, malreduction of the syndesmosis has been found to be the most important independent factor that contributes to inferior functional outcomes. Despite this, significant variability in surgical treatment remains. This may be due to a poor understanding of normal dynamic syndesmosis motion and the resultant impact of static and dynamic fixation on post-injury syndesmosis kinematics. As the syndesmosis is a dynamic structure, conventional CT static images do not provide a complete picture of syndesmosis position, giving potentially misleading results.
The syndesmosis ligament complex stabilizes the distal tibiofibular joint, while allowing for the subtle fibular motion that is essential for ankle congruity. Flexible fixation with anatomic syndesmosis reduction results in substantial improvements in functional outcomes. New
FAI has been implicated in the progression of osteoarthritis (OA) and early detection may allow for treatment, which can slow or halt progression. FAI is a difficult condition to image and there is little objective evidence about imaging accuracy. We aim to measure the accuracy of five imaging modalities. Three blinded observers retrospectively reviewed five different modalities from two age and sex matched groups: A patient group referred to the outpatient clinic with a clinical diagnosis of FAI and a control group who had had CT scans of the pelvis for suspected trauma, where the Pelvic scan had been reported as showing no injuries. The imaging modalities were: Standard x-ray; Antero-Posterior, Lateral; Condition-specific x-ray projections; Dunn view, lateral internal rotation; Standard Computer Tomography (CT) multiplanar reconstruction (MPR); axial, sagittal and coronal; Condition-specific CT MPR; angled axial, angled coronal; 3D modelling; and surface rendered dynamic. We found marked variations in the sensitivity, specificity, Positive Predictive Value (PPV) and Negative Predictiive Value (NPV) for each of the following imaging modalities: Standard X-ray; Sensitivity 51.9; Specificity; 57.1; PPV; 40; NPV; 68.3 Special X-rays; Sensitivity; 66.7; Specificity; 57.1; PPV; 46.1; NPV; 75.7. Standard CT MPR; Sensitivity; 40.7; Specificity; 75.5; PPV; 47.8; NPV; 69.8 Special CT MPR; Sensitivity; 48.1; Specificity; 57.1; PPV; 46.4; NPV; 70.8