Background

Procedural sedation (PS) requires two suitably qualified clinicians and a dedicated monitored bed space. We present the results of intra-articular haematoma blocks (IAHB), using local anaesthetic, for the manipulation of closed ankle fracture dislocations and compared resource use with PS.

Methods

Patients received intra-articular ankle haematoma blocks for displaced ankle fractures requiring manipulation between October 2020 to April 2021. The technique used 10ml of 1% lignocaine injected anteromedially into the tibiotalar joint. Pain scores (VAS), time from first x-ray to reduction, and acceptability of reduction were recorded. A comparison was made by retrospective analysis of patients who had undergone PS for manipulation of an ankle fracture over the six month period March – August 2020.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 4 - 4
17 Jun 2024
Carter T Oliver W Bell K Graham C Duckworth A White T Heinz N
Full Access

Introduction

Unstable ankle fractures are routinely managed operatively. Due to soft-tissue and implant related complications, there has been recent literature reporting on the non-operative management of well-reduced medial malleolus fractures following fibular stabilisation, but with limited evidence supporting routine application. This trial assessed the superiority of internal fixation of well-reduced (displacement ≤2mm) medial malleolus fractures compared with non-fixation following fibular stabilisation.

Methods and participants

Superiority, pragmatic, parallel, prospective randomised clinical trial conducted over a four year period. A total of 154 adult patients with a bi- or trimalleolar fractures were recruited from a single centre. Open injuries and vertical medial malleolar fractures were excluded. Following fibular stabilisation, patients were randomised intra-operatively on a 1:1 basis to fixation or non-fixation after satisfactory fluoroscopic fracture reduction was confirmed. The primary outcome was the Olerud Molander Ankle Score (OMAS) at one-year post-randomisation. Complications and radiographic outcomes were documented over the follow-up period.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 6 - 6
1 Dec 2017
O'Dowd D Brewer P Davies M leese K Chadwick C Howard D Blundell C
Full Access

Introduction

Standard teaching of dislocated ankles was always reduce then x-ray. However the 2016 BOAST guidelines stated “Reduction and splinting should be performed urgently for clinically deformed ankles. Radiographs should be obtained before reduction unless this will cause an unacceptable delay”. We aimed to audit our practice against the BOAST guidelines and look at time from attendance to reduction.

Methods

We retrospectively reviewed all case notes of patients admitted via A&E at the Northern General Hospital with a fractured ankle between August 2016 and January 2017. Time of arrival, time to x-ray and time to reduction were recorded in a database for analysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 2 - 2
1 Dec 2017
Agarwal S Iliopoulos E Khaleel A
Full Access

Aim

Anatomical reduction and Stable fixation of Lisfranc injuries is considered the gold standard. There is controversy about how it is best achieved. Some surgeons would advocate routine open anatomical reduction, which as a concept was popular in 1980s but the same anatomical reduction and fixation can be achieved percutaneously. We describe our method of close reduction and percutaneous fixation and present our results.

Materials and methods

22 patients with a minimum follow up of 12 months were included. We achieved satisfactory anatomical reduction percutaneously in all patients and internal fixation was performed using cannulated screws for medial and middle columns. Functional outcome was evaluated using Foot and Ankle Disability Index (FADI) and components of this score were analysed individually to assess which domain was most affected. Vertical ground reaction forces were measured using a force plate in a walking platform.