Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 387 - 392
1 Mar 2011
Robinson CM Murray IR

Fractures and nonunions of the proximal humerus are increasingly treated by open reduction and internal fixation. The extended deltopectoral approach remains the most widely used for this purpose. However, it provides only limited exposure of the lateral and posterior aspects of the proximal humerus. We have previously described the alternative extended deltoid-splitting approach. In this paper we outline variations and extensions of this technique that we have developed in the management of further patients with these fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1107 - 1112
1 Nov 2000
Hintermann B Trouillier HH Schäfer D

In 42 elderly patients, 33 women and nine men with a mean age of 72 years, we treated displaced fractures of the proximal humerus (34 three-part, 8 four-part) using a blade plate and a standard deltopectoral approach. Functional treatment was started immediately after surgery. We reviewed 41 patients at one year and 38 at final follow-up at 3.4 years (2.4 to 4.5). At the final review, all the fractures had healed. The clinical results were graded as excellent in 13 patients, good in 17, fair in seven, and poor in one. The median Constant score was 73 ± 18. Avascular necrosis of the humeral head occurred in two patients (5%). We conclude that rigid fixation of displaced fractures of the proximal humerus with a blade plate in the elderly patient provides sufficient primary stability to allow early functional treatment. The incidence of avascular necrosis and nonunion was low. Restoration of the anatomy and biomechanics may contribute to a good functional outcome when compared with alternative methods of fixation or conservative treatment. Regardless of the age of the patients, we advocate primary open reduction and rigid internal fixation of three- and four-part fractures of the proximal humerus


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 114 - 114
1 Sep 2012
Grisch D Riede U Gerber C Jost B
Full Access

Background. In elderly patients with complex proximal humerus fractures and osteoporotic bone reconstruction is not always possible. Although hemiarthroplasty is an alternative, non-union or tuberosity migration can lead to inferior functional results. Implantation of a Reverse Total Shoulder Arthroplasty (RTSA) seems to be an interesting alternative. In the present study we retrospectively analyzed the short-term results of RTSA for complex proximal humerus fractures in the elderly. Methods. From 31.10.2005 to 20.07.2010 RTSA was performed in 29 patients (average age 80 years [67;90], 25 women, 4 man) with subcapital, three- or four-part fracture of the proximal humerus as a primary treatment. All procedures were performed using the Anatomical Inverse Shoulder (Zimmer) with fracture stem. A deltopectoral approach was used in every case with reattachment of the tuberosities. Pain, range of motion, subjected shoulder value (SSV) as well as the Constant score (CS) were used to evaluate shoulder function. Implant positioning and signs of loosening were analyzed on standard x-rays. Results. Included were 23 patients with a minimal follow-up of 12 month. The average follow-up was 17 month (12 month to 5 years). The mean SSV was 81% [40;100]. The absolute CS averaged 67 points [34;84] and the relative CS 97% [52;139]. The mean pain score (VAS) was 13.7 of 15, the mean activity score 18.4 of 20, the mean mobility score 28.6 of 40 and the mean strength score 5.1 of 25. The mean active anterior elevation was 130° [80;160], the mean active abduction 128° [80;170] and the mean active external rotation in 0° abduction 21° [-30;70]. All patients reached the same activity level as before surgery and could return to independent living. The results after 12 month were already comparable to those after 24 month (10 patients). Radiographically no signs of loosening were detected. There was a total of 3 complications and reoperations, two due to a hematoma and one because of a periprosthetic fracture. Conclusions. In elderly patients with complex proximal humerus fractures and osteoporotic bone RTSA seems to be a very satisfactory procedure. The short-term clinical results are excellent and predictable with a rapid postoperative recovery of daily comfort. The complication rate is low and acceptable


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 23 - 23
1 Sep 2012
Petroff E Petroff E Audebert S Delobelle JM
Full Access

We evaluated the results of Cementless Surface Replacement Arthroplasty (CSRA) of the shoulder in 67 patients with advanced glenohumeral destruction who have an intact rotator cuff. Between november 2002 and december 2008, 70 CSRA (32 Copeland/ Biomet and 38 SMRR/ Lima) were implanted in 67 patients. A deltopectoral approach was used in 34 cases and an anterosuperior approach in 36 cases. Patients were assessed using Constant score, a patient satisfaction score and a detailed radiographic analysis. The mean follow up was 3.4 years (range 1 to 7.5 years). The mean Constant score improved preoperatively from 17.6 points (range 2–55) to an average postoperative score of 66.1 (range 13–91). The pain score improved from 1.13 points (range 0–6) to 12.3 points (range 3–15). The forward flexion and external rotation improved from 71° (range 20 to 140) and 0° (range −40 to +45) to 143° (range 60 to180) and 34.4° (range −20 to +60) respectively. Complications included: 1 subscapularis detachment, 5 secondary rotator cuff tear, 1sepsis, 3 patients with shoulder stiffness. No shift in implant position was observed. 11 humeral components developed radiolucencies at the prosthesis-bone interface. The radiographic analysis involved a system of dividing the prosthesis/bone interface into 5 zones. The best clinical results were significantly achieved in patients with necrosis compared with osteoarthritis (Constant Score, ant. elevation, ext. Rotation). Using regression analysis we found that changes in the head-shaft angle position of the implant (valgus/varus placement of the CSRA) significantly predicted the age and sex adjusted Constant score. When the inclination angle of the humeral head decreases, the adjusted Constant score increases. In the same model, we also found that the lateral offset of the humerus significantly predicted the adjusted Constant score. When the lateral offset of the humerus decreases, the adjusted Constant score increases. The medialization of the glenoid significantly and negatively predicted the Constant score. Conclusion. CSRA of the shoulder outcomes have been comparable with those of stemmed arthroplasties. Radiolucent lines occur with follow up and most of the time located in the S1 area. Glenoid wear and humeral head lateralization negatively impact the clinical score. Cementless Shoulder resurfacing is a viable alternative to conventional shoulder arthroplasty


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1206 - 1209
1 Sep 2007
Moonot P Ashwood N Hamlet M

Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population.

This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 516 - 520
1 Apr 2007
Bufquin T Hersan A Hubert L Massin P

We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58).

The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed peri-prosthetic calcification in 36 patients (90%), displacement of the tuberosities in 19 (53%) and a scapular notch in ten (25%). Compared with conventional hemiarthroplasty, satisfactory mobility was obtained despite frequent migration of the tuberosities. However, long-term results are required before reverse shoulder arthroplasty can be recommended as a routine procedure in complex fractures of the upper humerus in the elderly.