Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 12 - 12
1 Jun 2017
Patel D Howard N Nayagam S
Full Access

Background

Temporary hemiepiphysiodesis using 8 plate guided growth has gained widespread acceptance for the treatment of paediatric angular deformities. This study aims to look at outcomes of coronal lower limb deformities corrected using temporary hemiepiphysiodesis over an extended period of follow up.

Methods

A retrospective analysis was undertaken of 56 children (92 legs) with coronal plane deformities around the knee which were treated with an extraperiosteal 2 holed titanium plate and screws between 2007 and 2015. Pre and post-op long leg radiographs and clinic letters were reviewed.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 748 - 752
1 Sep 1997
Song H Cho S Jeong S Park Y Koo K

Stable fixation after a corrective supracondylar osteotomy in adults is difficult because of the irregularity of the area of bony contact, displacement of the fragments, the predominance of cortical bone, and the need for early mobilisation.

We have used the Ilizarov apparatus for fixation in 15 patients who were treated by complex osteotomies with displacement of fragments for cubitus varus or valgus. Most patients with cubitus varus required medial displacement with rotation of the distal fragment. Those with cubitus valgus required lateral shift of the distal fragment to reduce the medial prominence of the elbow that would otherwise result.

All osteotomies united within the expected time without loss of correction, despite early mobilisation. Complications related to the fixation were few and had resolved at the long-term follow-up.


Background:

Acute deformity correction with the help of osteotomies and stabilisation with intramedullary (IM) nail is a recognised technique. We present our case series of long bong deformity correction using an innovative technique that aids accurate correction after osteotomy and insertion of IM nail.

Technique:

On preoperative measurements the distance of the joint surface from the point of intersection of the joint orientation angle with the convex cortex and also its distance from apex of deformity were noted. These distances were reproduced intraoperatively and guide pin was inserted towards premeasured point in the convex cortex. Osteotomy was performed and appropriate sized locked IM nail inserted with the help of temporary blocking screws, resulting in the correction of deformities.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 25 - 25
1 May 2018
Chilbule S Qureshi A Hill C Nicolaou N Giles SN Fernandes JA
Full Access

Purpose. Surgical correction of upper limb deformities in severe osteogenesis imperfecta (OI) is technically difficult and less absolving, hence we aimed to analyse the surgical complications of rodding the humeri in severe OI. Methods and results. Retrospective analysis was carried out for consecutive humeral roddings for severe OI in last 3 years. Surgical technique for all humeri included retrograde telescopic nailing (female or both of FD or TST rods) with entry from olecranon fossa, exploration of radial nerve followed by osteotomies. Deformities were quantified and sub-classified as per level of deformity). Variables such as number of osteotomies, radiological union, intraoperative and postoperative complications, improvement in ROM and subjective patient satisfaction were recorded. Total 18 humeri in 12 patients with type III OI (except 1) with mean age of 8.9 years underwent nailing. All patients achieved radiological union at 6–10 weeks. Total 8 complications (44.4 %) were reported within mean 8.4 months follow up. Four segments (22.2 %) had intraoperative fractures at distal third of the humerus while negotiating the nail. Significantly higher intraoperative complications were encountered in humeri fixed with both components combined and upper third level deformities, deformities > 900 and more than 2 osteotomies. Other complications were prominent implant at upper end (2) with growth and one each of contralateral fracture and distal humeral varus. All patients reported improvement in ROM and functional status. Conclusion. Significant complications are associated with humeral nailing for severe OI. Quantification of the deformity with meticulous surgical planning and execution is advised. Despite these complications outcomes show benefits of the surgical treatment. Level of evidence. Therapeutic III