Advertisement for orthosearch.org.uk
Results 1 - 20 of 4048
Results per page:
Bone & Joint Research
Vol. 10, Issue 3 | Pages 192 - 202
1 Mar 2021
Slimi F Zribi W Trigui M Amri R Gouiaa N Abid C Rebai MA Boudawara T Jebahi S Keskes H

Aims. The present study investigates the effectiveness of platelet-rich plasma (PRP) gel without adjunct to induce cartilage regeneration in large osteochondral defects in a rabbit model. Methods. A bilateral osteochondral defect was created in the femoral trochlear groove of 14 New Zealand white rabbits. The right knees were filled with PRP gel and the contralateral knees remained untreated and served as control sides. Some animals were killed at week 3 and others at week 12 postoperatively. The joints were harvested and assessed by Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) MRI scoring system, and examined using the International Cartilage Repair Society (ICRS) macroscopic and ICRS histological scoring systems. Additionally, the collagen type II content was evaluated by the immunohistochemical staining. Results. After 12 weeks post-surgery, the defects of the PRP group were repaired by hyaline cartilage-like tissue. However, incomplete cartilage regeneration was observed in the PRP group for three weeks. The control groups showed fibrocartilaginous or fibrous tissue, respectively, at each timepoint. Conclusion. Our study proved that the use of PRP gel without any adjuncts could successfully produce a good healing response and resurface the osteochondral defect with a better quality of cartilage in a rabbit model. Cite this article: Bone Joint Res 2021;10(3):192–202


Bone & Joint Research
Vol. 12, Issue 9 | Pages 546 - 558
12 Sep 2023
Shen J Wei Z Wang S Wang X Lin W Liu L Wang G

Aims. This study aimed to evaluate the effectiveness of the induced membrane technique for treating infected bone defects, and to explore the factors that might affect patient outcomes. Methods. A comprehensive search was performed in PubMed, Embase, and the Cochrane Central Register of Controlled Trials databases between 1 January 2000 and 31 October 2021. Studies with a minimum sample size of five patients with infected bone defects treated with the induced membrane technique were included. Factors associated with nonunion, infection recurrence, and additional procedures were identified using logistic regression analysis on individual patient data. Results. After the screening, 44 studies were included with 1,079 patients and 1,083 segments of infected bone defects treated with the induced membrane technique. The mean defect size was 6.8 cm (0.5 to 30). After the index second stage procedure, 85% (797/942) of segments achieved union, and 92% (999/1,083) of segments achieved final healing. The multivariate analysis with data from 296 patients suggested that older age was associated with higher nonunion risk. Patients with external fixation in the second stage had a significantly higher risk of developing nonunion, increasing the need for additional procedures. The autografts harvested from the femur reamer-irrigator-aspirator increased nonunion, infection recurrence, and additional procedure rates. Conclusion. The induced membrane technique is an effective technique for treating infected bone defects. Internal fixation during the second stage might effectively promote bone healing and reduce additional procedures without increasing infection recurrence. Future studies should standardize individual patient data prospectively to facilitate research on the affected patient outcomes. Cite this article: Bone Joint Res 2023;12(9):546–558


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 613 - 622
1 Jun 2024
Shen J Wei Z Wu H Wang X Wang S Wang G Luo F Xie Z

Aims. The aim of the present study was to assess the outcomes of the induced membrane technique (IMT) for the management of infected segmental bone defects, and to analyze predictive factors associated with unfavourable outcomes. Methods. Between May 2012 and December 2020, 203 patients with infected segmental bone defects treated with the IMT were enrolled. The digital medical records of these patients were retrospectively analyzed. Factors associated with unfavourable outcomes were identified through logistic regression analysis. Results. Among the 203 enrolled patients, infection recurred in 27 patients (13.3%) after bone grafting. The union rate was 75.9% (154 patients) after second-stage surgery without additional procedures, and final union was achieved in 173 patients (85.2%) after second-stage surgery with or without additional procedures. The mean healing time was 9.3 months (3 to 37). Multivariate logistic regression analysis of 203 patients showed that the number (≥ two) of debridements (first stage) was an independent risk factor for infection recurrence and nonunion. Larger defect sizes were associated with higher odds of nonunion. After excluding 27 patients with infection recurrence, multivariate analysis of the remaining 176 patients suggested that intramedullary nail plus plate internal fixation, smoking, and an allograft-to-autograft ratio exceeding 1:3 adversely affected healing time. Conclusion. The IMT is an effective method to achieve infection eradication and union in the management of infected segmental bone defects. Our study identified several risk factors associated with unfavourable outcomes. Some of these factors are modifiable, and the risk of adverse outcomes can be reduced by adopting targeted interventions or strategies. Surgeons can fully inform patients with non-modifiable risk factors preoperatively, and may even use other methods for bone defect reconstruction. Cite this article: Bone Joint J 2024;106-B(6):613–622


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims. Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods. We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results. Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion. Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 880 - 887
1 Aug 2023
Onodera T Momma D Matsuoka M Kondo E Suzuki K Inoue M Higano M Iwasaki N

Aims. Implantation of ultra-purified alginate (UPAL) gel is safe and effective in animal osteochondral defect models. This study aimed to examine the applicability of UPAL gel implantation to acellular therapy in humans with cartilage injury. Methods. A total of 12 patients (12 knees) with symptomatic, post-traumatic, full-thickness cartilage lesions (1.0 to 4.0 cm. 2. ) were included in this study. UPAL gel was implanted into chondral defects after performing bone marrow stimulation technique, and assessed for up to three years postoperatively. The primary outcomes were the feasibility and safety of the procedure. The secondary outcomes were self-assessed clinical scores, arthroscopic scores, tissue biopsies, and MRI-based estimations. Results. No obvious adverse events related to UPAL gel implantation were observed. Self-assessed clinical scores, including pain, symptoms, activities of daily living, sports activity, and quality of life, were improved significantly at three years after surgery. Defect filling was confirmed using second-look arthroscopy at 72 weeks. Significantly improved MRI scores were observed from 12 to 144 weeks postoperatively. Histological examination of biopsy specimens obtained at 72 weeks after implantation revealed an extracellular matrix rich in glycosaminoglycan and type II collagen in the reparative tissue. Histological assessment yielded a mean overall International Cartilage Regeneration & Joint Preservation Society II score of 69.1 points (SD 10.4; 50 to 80). Conclusion. This study provides evidence supporting the safety of acellular UPAL gel implantation in facilitating cartilage repair. Despite being a single-arm study, it demonstrated the efficacy of UPAL gel implantation, suggesting it is an easy-to-use, one-step method of cartilage tissue repair circumventing the need to harvest donor cells. Cite this article: Bone Joint J 2023;105-B(8):880–887


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 54 - 58
1 May 2024
Wassilew GI Zimmerer A Fischer M Nonnenmacher L O'Hara L Hube R

Aims. The use of a porous metal shell supported by two augments with the ‘footing’ technique is one solution to manage Paprosky IIIB acetabular defects in revision total hip arthroplasty. The aim of this study was to assess the medium-term implant survival and radiological and clinical outcomes of this technique. Methods. We undertook a retrospective, two-centre series of 39 hips in 39 patients (15 male, 24 female) treated with the ‘footing’ technique for Paprosky IIIB acetabular defects between 2007 and 2020. The median age at the time of surgery was 64.4 years (interquartile range (IQR) 54.4 to 71.0). The median follow-up was 3.9 years (IQR 3.1 to 7.0). Results. The cumulative medium-term survival of the acetabular construct was 89%. Two hips (5.1%) required further revision due to shell loosening, one hip (2.6%) due to shell dislocation, and one hip (2.6%) due to infection. The median Harris Hip Score improved significantly from 47 points (IQR 41.5 to 54.9) preoperatively to 80 points (IQR 73.5 to 88.6) at the latest follow-up (p < 0.001). Conclusion. The reconstruction of Paprosky IIIB acetabular defects with porous tantalum shells and two augments using the ‘footing’ technique showed excellent medium-term results. It is a viable option for treating these challenging defects. Cite this article: Bone Joint J 2024;106-B(5 Supple B):54–58


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 82 - 88
1 May 2024
Villa JM Rajschmir K Hosseinzadeh S Manrique-Succar J Grieco P Higuera-Rueda CA Riesgo AM

Aims. Large bone defects resulting from osteolysis, fractures, osteomyelitis, or metastases pose significant challenges in acetabular reconstruction for total hip arthroplasty. This study aimed to evaluate the survival and radiological outcomes of an acetabular reconstruction technique in patients at high risk of reconstruction failure (i.e. periprosthetic joint infection (PJI), poor bone stock, immunosuppressed patients), referred to as Hip Reconstruction In Situ with Screws and Cement (HiRISC). This involves a polyethylene liner embedded in cement-filled bone defects reinforced with screws and/or plates for enhanced fixation. Methods. A retrospective chart review of 59 consecutive acetabular reconstructions was performed by four surgeons in a single institution from 18 October 2018 to 5 January 2023. Cases were classified based on the Paprosky classification, excluding type 1 cases (n = 26) and including types 2 or 3 for analysis (n = 33). Radiological loosening was evaluated by an orthopaedic surgeon who was not the operating surgeon, by comparing the immediate postoperative radiographs with the ones at latest follow-up. Mean follow-up was 557 days (SD 441; 31 to 1,707). Results. Out of the 33 cases analyzed, six (18.2%) constructs required revision, with four revisions due to uncontrolled infection, one for dislocation, and one for aseptic loosening. Among the 27 non-revised constructs, only one showed wider radiolucencies compared to immediate postoperative radiographs, indicating potential loosening. Patients who underwent revision (n = 6) were significantly younger and had a higher BMI compared to those with non-revised constructs (p = 0.016 and p = 0.026, respectively). Sex, race, ethnicity, American Society of Anesthesiologists grade, infection status (patients with postoperative PJI diagnosis (septic) vs patients without such diagnosis (aseptic)), and mean follow-up did not significantly differ between revised and non-revised groups. Conclusion. The HiRISC technique may serve as a feasible short-term (about one to two years) alternative in patients with large acetabular defects, particularly in cases of PJI. Longer follow-up is necessary to establish the long-term survival of this technique. Cite this article: Bone Joint J 2024;106-B(5 Supple B):82–88


Bone & Joint Open
Vol. 5, Issue 8 | Pages 688 - 696
22 Aug 2024
Hanusrichter Y Gebert C Steinbeck M Dudda M Hardes J Frieler S Jeys LM Wessling M

Aims. Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction. Methods. Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors. Results. Implantation was possible in all cases with a 2D centre of rotation deviation of 10 mm (SD 5.8; 1 to 29). PPR revision was necessary in eight (10%) patients. HHS increased significantly from 33 to 72 postoperatively, with a mean increase of 39 points (p < 0.001). Postoperative EQ-5D score was 0.7 (SD 0.3; -0.3 to 1). Risk factor analysis showed significant revision rates for septic indications (p ≤ 0.001) as well as femoral defect size (p = 0.001). Conclusion. Since large acetabular defects are being treated surgically more often, custom-made PPR should be integrated as an option in treatment algorithms. Monoflange PPR, with primary iliac fixation, offers a viable treatment option for Paprosky III defects with promising functional results, while requiring less soft-tissue exposure and allowing immediate full weightbearing. Cite this article: Bone Jt Open 2024;5(8):688–696


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 68 - 68
11 Apr 2023
Turnbull G Picard F Clarke J Shu W
Full Access

As arthroplasty demand grows worldwide, the need for a novel cost-effective treatment option for articular cartilage (AC) defects tailored to individual patients has never been greater. 3D bioprinting can deposit patient cells and other biomaterials in user-defined patterns to build tissue constructs from the “bottom-up,” potentially offering a new treatment for AC defects. The aim of this research was to create bioinks that can be injected or 3D bioprinted to aid osteochondral defect repair using human cells. Novel composite bioinks were created by mixing different ratios of methacrylated alginate (AlgMA) with methacrylated gelatin (GelMA). Chondrocytes or mesenchymal stem cells (MSCs) were then encapsulated in the bioinks and 3D bioprinted using a custom-built extrusion bioprinter. UV and double-ionic (BaCl2 and CaCl2) crosslinking was deployed following bioprinting to strengthen bioink stability in culture. Chondrocyte and MSC spheroids were also produced via 3D culture and then bioprinted to accelerate cell growth and development of ECM in bioprinted constructs. Excellent viability of chondrocytes and MSCs was seen following bioprinting (>95%) and maintained in culture over 28 days, with accelerated cell growth seen with inclusion of MSC or chondrocyte spheroids in bioinks (p<0.05). Bioprinted 10mm diameter constructs maintained shape in culture over 28 days, whilst construct degradation rates and mechanical properties were improved with addition of AlgMA (p<0.05). Composite bioinks were also injected into in vitro osteochondral defects (OCDs) and crosslinked in situ, with maintained cell viability and repair of osteochondral defects seen over a 14-day period. In conclusion we developed novel composite AlgMA/GelMA bioinks that can be triple-crosslinked, facilitating dense chondrocyte and MSC growth in constructs following 3D bioprinting. The bioink can be injected or 3D bioprinted to successfully repair in vitro OCDs, offering hope for a new approach to treating AC defects


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 108 - 108
11 Apr 2023
Turnbull G Picard F Clarke J Li B Shu W
Full Access

As arthroplasty demand grows worldwide, the need for a novel cost-effective treatment option for articular cartilage (AC) defects tailored to individual patients has never been greater. 3D bioprinting can deposit patient cells and other biomaterials in user-defined patterns to build tissue constructs from the “bottom-up,” potentially offering a new treatment for AC defects. The aim of this research was to create bioinks that can be injected or 3D bioprinted to aid osteochondral defect repair using human cells. Novel composite bioinks were created by mixing different ratios of methacrylated alginate (AlgMA) with methacrylated gelatin (GelMA). Chondrocytes or mesenchymal stem cells (MSCs) were then encapsulated in the bioinks and 3D bioprinted using a custom-built extrusion bioprinter. UV and double-ionic (BaCl2 and CaCl2) crosslinking was deployed following bioprinting to strengthen bioink stability in culture. Chondrocyte and MSC spheroids were also bioprinted to accelerate cell growth and development of ECM in bioprinted constructs. Excellent viability of chondrocytes and MSCs was seen following bioprinting (>95%) and maintained in culture over 28 days, with accelerated cell growth seen with inclusion of MSC or chondrocyte spheroids in bioinks (p<0.05). Bioprinted 10mm diameter constructs maintained shape in culture over 28 days, whilst construct degradation rates and mechanical properties were improved with addition of AlgMA (p<0.05). Composite bioinks were also injected into in vitro osteochondral defects (OCDs) and crosslinked in situ, with maintained cell viability and repair of osteochondral defects seen over a 14-day period. In conclusion we developed novel composite AlgMA/GelMA bioinks that can be triple-crosslinked, facilitating dense chondrocyte and MSC growth in constructs following 3D bioprinting. The bioink can be injected or 3D bioprinted to successfully repair in vitro OCDs, offering hope for a new approach to treating AC defects


Bone & Joint Research
Vol. 12, Issue 8 | Pages 467 - 475
2 Aug 2023
Wu H Sun D Wang S Jia C Shen J Wang X Hou C Xie Z Luo F

Aims. This study was designed to characterize the recurrence incidence and risk factors of antibiotic-loaded cement spacer (ALCS) for definitive bone defect treatment in limb osteomyelitis. Methods. We included adult patients with limb osteomyelitis who received debridement and ALCS insertion into the bone defect as definitive management between 2013 and 2020 in our clinical centre. The follow-up time was at least two years. Data on patients’ demographics, clinical characteristics, and infection recurrence were retrospectively collected and analyzed. Results. In total, 314 patients with a mean age of 52.1 years (SD 12.1) were enrolled. After a mean of 50 months’ (24 to 96) follow-up, 53 (16.9%) patients had infection recurrence including 32 tibiae, ten femora, ten calcanea, and one humerus. Of all patients with recurrence, 30 (9.6%) occurred within one year and 39 (12.4%) within two years. Among them, 41 patients needed reoperation, five received antibiotics treatment only, and seven ultimately required amputations. Following multivariable analysis, we found that patients infected with Gram-negative bacilli were more likely to have a recurrence (odds ratio (OR) 2.38, 95% confidence interval (CI) 1.20 to 6.94; p = 0.046) compared to Staphylococcus aureus; segmental bone defects (OR 5.25, 95% CI 1.80 to 15.26; p = 0.002) and smoking (OR 3.00, 95% CI 1.39 to 6.50; p = 0.005) were also independent risk factors for recurrence after treatment. Conclusion. Permanent ALCS might be an alternative strategy for definitive bone defect management in selected osteomyelitis cases. However, the overall high recurrence found suggests that it should be cautiously treated. Additionally, segmental defects, Gram-negative infections, and smoking were associated with an increased risk of infection recurrence. Cite this article: Bone Joint Res 2023;12(8):467–475


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 600 - 606
1 May 2002
Lietman SA Miyamoto S Brown PR Inoue N Reddi AH

Damage to articular cartilage is a common injury, for which there is no effective treatment. Our aims were to investigate the temporal sequence of the repair of articular cartilage and to define a critical-size defect. Full-thickness defects were made in adult male New Zealand white rabbits. The diameter (1 to 4 mm) of the defects was varied in order to determine the effect that the size and depth of the defect had on its healing. The defects were made in the femoral groove of the knee with one defect per knee and eight knees per group. The tissues were fixed in formalin at days 3, 7, 14, 21, 28, 42, 84 and 126 after operation and the sections stained with Toluidine Blue. These were then examined and evaluated for several parameters including the degree of metachromasia and the amount of subchondral bone which had reformed in the defect. The defects had a characteristic pattern of healing which differed at different days and for different sizes of defect. Specifically, the defects of 1 mm first peaked in terms of metachromasia at day 21, those of 2 mm at day 28, followed by defects of 3 mm and 4 mm. The healing of the subchondral bone was slowest in defects of 1 mm


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 38 - 38
1 Jun 2023
Hrycaiczuk A Biddlestone J Rooney B Mahendra A Fairbairn N Jamal B
Full Access

Introduction. A significant burden of disease exists with respect to critical sized bone defects; outcomes are unpredictable and often poor. There is no absolute agreement on what constitutes a “critically-sized” bone defect however it is widely considered as one that would not heal spontaneously despite surgical stabilisation, thus requiring re-operation. The aetiology of such defects is varied. High-energy trauma with soft tissue loss and periosteal stripping, bone infection and tumour resection all require extensive debridement and the critical-sized defects generated require careful consideration and strategic management. Current management practice of these defects lacks consensus. Existing literature tells us that tibial defects 25mm or great have a poor natural history; however, there is no universally agreed management strategy and there remains a significant evidence gap. Drawing its origins from musculoskeletal oncology, the Capanna technique describes a hybrid mode of reconstruction. Mass allograft is combined with a vascularised fibula autograft, allowing the patient to benefit from the favourable characteristics of two popular reconstruction techniques. Allograft confers initial mechanical stability with autograft contributing osteogenic, inductive and conductive capacity to encourage union. Secondarily its inherent vascularity affords the construct the ability to withstand deleterious effects of stressors such as infection that may threaten union. The strengths of this hybrid construct we believe can be used within the context of critical-sized bone defects within tibial trauma to the same success as seen within tumour reconstruction. Methodology. Utilising the Capanna technique in trauma requires modification to the original procedure. In tumour surgery pre-operative cross-sectional imaging is a pre-requisite. This allows surgeons to assess margins, plan resections and order allograft to match the defect. In trauma this is not possible. We therefore propose a two-stage approach to address critical-sized tibial defects in open fractures. After initial debridement, external fixation and soft tissue management via a combined orthoplastics approach, CT imaging is performed to assess the defect geometry, with a polymethylmethacrylate (PMMA) spacer placed at index procedure to maintain soft tissue tension, alignment and deliver local antibiotics. Once comfortable that no further debridement is required and the risk of infection is appropriate then 3D printing technology can be used to mill custom jigs. Appropriate tibial allograft is ordered based on CT measurements. A pedicled fibula graft is raised through a lateral approach. The peroneal vessels are mobilised to the tibioperoneal trunk and passed medially into the bone void. The cadaveric bone is prepared using the custom jig on the back table and posterolateral troughs made to allow insertion of the fibula, permitting some hypertrophic expansion. A separate medial incision allows attachment of the custom jig to host tibia allowing for reciprocal cuts to match the allograft. The fibula is implanted into the allograft, ensuring nil tension on the pedicle and, after docking the graft, the hybrid construct is secured with multi-planar locking plates to provide rotational stability. The medial window allows plate placement safely away from the vascular pedicle. Results. We present a 50-year-old healthy male with a Gustilo & Anderson 3B proximal tibial fracture, open posteromedially with associated shear fragment, treated using the Capanna technique. Presenting following a fall climbing additional injuries included a closed ipsilateral calcaneal and medial malleolar fracture, both treated operatively. Our patient underwent reconstruction of his tibia with the above staged technique. Two debridements were carried out due to a 48-hour delay in presentation due to remote geographical location of recovery. Debridements were carried out in accordance with BOAST guidelines; a spanning knee external fixator applied and a small area of skin loss on the proximal medial calf reconstructed with a split thickness skin graft. A revision cement spacer was inserted into the metaphyseal defect measuring 84mm. At definitive surgery the external fixator was removed and graft fixation was extended to include the intra-articular fragments. No intra-operative complications were encountered during surgeries. The patient returned to theatre on day 13 with a medial sided haematoma. 20ml of haemoserous fluid was evacuated, a DAIR procedure performed and antibiotic-loaded bioceramics applied locally. Samples grew Staphylococcus aureus and antibiotic treatment was rationalised to Co-Trimoxazole 960mg BD and Rifampicin 450mg BD. The patient has completed a six-week course of Rifampicin and continues on suppressive Co-Trimoxazole monotherapy until planned metalwork removal. There is no evidence of ongoing active infection and radiological evidence of early union. The patient is independently walking four miles to the gym daily and we believe, thus far, despite accepted complications, we have demonstrated a relative early success. Conclusions. A variety of techniques exist for the management of critical-sized bone defects within the tibia. All of these come with a variety of drawbacks and limitations. Whilst acceptance of a limb length discrepancy is one option, intercalary defects of greater than 5 to 7cm typically require reconstruction. In patients in whom fine wire fixators and distraction osteogenesis are deemed inappropriate, or are unwilling to tolerate the frequent re-operations and potential donor site morbidity of the Masqualet technique, the Capanna technique offers a novel solution. Through using tibial allograft to address the size mismatch between vascularised fibula and tibia, the possible complication of fatigue fracture of an isolated fibula autograft is potentially avoidable in patients who have high functional demands. The Capanna technique has demonstrated satisfactory results within tumour reconstruction. Papers report that by combining the structural strength of allograft with the osteoconductive and osteoinductive properties of a vascularised autograft that limb salvage rates of greater than 80% and union rates of greater than 90% are achievable. If these results can indeed be replicated in the management of critical-sized bone defects in tibial trauma we potentially have a treatment strategy that can excel over the more widely practiced current techniques


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 35 - 35
7 Nov 2023
Tsang J Epstein G Ferreira N
Full Access

The Cierny and Mader classification assists with decision-making in the management of osteomyelitis by strafying the host status and the pathoanatomy of disease. However the anatomical type IV represents a heterogenous group with regards to treatment requirements and outcomes. We propose that modification of the Cierny and Mader anatomical classification with an additional type V classifier (diffuse corticomedullary involvement with an associated critical bone defect) will allow more accurate stratification of patients and tailoring of treatment strategies. A retrospective review of 83 patients undergoing treatment for Cierny and Mader anatomical type IV osteomyelitis of the appendicular skeleton at a single centre was performed. Risk factors for the presence of a critical bone defect were female patients (OR 3.1 (95% CI 1.08– 8.92)) and requirement for soft tissue reconstruction (OR 3.35 (95% CI 1.35–8.31)); osteomyelitis of the femur was negatively associated with the presence of a critical bone defect (OR 0.13 (95% CI 0.03–0.66)). There was no statistical significant risk of adverse outcomes (failure to eradicate infection or achieve bone union) associated with the presence of a critical-sized bone defect. The median time to bone union was ten months (95% CI 7.9–12.1 months). There was a statistically significant difference in the median time to bone union between cases with a critical bone defect (12.0 months (95% 10.2–13.7 months)) and those without (6.0 months (95% CI 4.8–7.1 months)). This study provided evidence to support the introduction of a new subgroup of the Cierny and Mader anatomical classification (Type V). Using a standardised approach to management, comparable early outcomes can be achieved in patients with Cierny and Mader anatomical type V osteomyelitis. However, to achieve a successful outcome, there is a requirement for additional bone and soft tissue reconstruction procedures with an associated increase in treatment time


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 2 - 2
23 Apr 2024
Tsang SJ Epstein G Ferreira N
Full Access

Introduction. The Cierny and Mader classification assists with decision-making by stratifying host status and the pathoanatomy of the disease. However, the anatomical type IV represents a heterogenous group with regards to treatment requirements and outcomes. We propose that modification of the Cierny and Mader anatomical classification with an additional type V classifier (diffuse corticomedullary involvement with an associated critical bone defect) will allow more accurate stratification of patients and tailoring of treatment strategies. Materials & Methods. A retrospective review of 83 patients undergoing treatment for Cierny and Mader anatomical type IV osteomyelitis of the appendicular skeleton at a single centre was performed. Results. Risk factors for the presence of a critical bone defect were female patients (OR 3.1 (95% CI 1.08–8.92)) and requirement for soft tissue reconstruction (OR 3.35 (95% CI 1.35–8.31)); osteomyelitis of the femur was negatively associated with the presence of a critical bone defect (OR 0.13 (95% CI 0.03–0.66)). There was no statistically significant risk of adverse outcomes (failure to eradicate infection or achieve bone union) associated with the presence of a critical-sized bone defect. The median time to bone union was ten months (95% CI 7.9–12.1 months). There was a statistically significant difference in the median time to bone union between cases with a critical bone defect (12.0 months (95% 10.2–13.7 months)) and those without (6.0 months (95% CI 4.8–7.1 months)). Conclusions. This study provided evidence to support the introduction of a new subgroup of the Cierny and Mader anatomical classification (Type V). Using a standardised approach to management, comparable early outcomes can be achieved in patients with Cierny and Mader anatomical type V osteomyelitis. However, to achieve a successful outcome, there is a requirement for additional bone and soft tissue reconstruction procedures with an associated increase in treatment time


Bone & Joint Research
Vol. 11, Issue 6 | Pages 349 - 361
9 Jun 2022
Jun Z Yuping W Yanran H Ziming L Yuwan L Xizhong Z Zhilin W Xiaoji L

Aims. The purpose of this study was to explore a simple and effective method of preparing human acellular amniotic membrane (HAAM) scaffolds, and explore the effect of HAAM scaffolds with juvenile cartilage fragments (JCFs) on osteochondral defects. Methods. HAAM scaffolds were constructed via trypsinization from fresh human amniotic membrane (HAM). The characteristics of the HAAM scaffolds were evaluated by haematoxylin and eosin (H&E) staining, picrosirius red staining, type II collagen immunostaining, Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). Human amniotic mesenchymal stem cells (hAMSCs) were isolated, and stemness was verified by multilineage differentiation. Then, third-generation (P3) hAMSCs were seeded on the HAAM scaffolds, and phalloidin staining and SEM were used to detect the growth of hAMSCs on the HAAM scaffolds. Osteochondral defects (diameter: 3.5 mm; depth: 3 mm) were created in the right patellar grooves of 20 New Zealand White rabbits. The rabbits were randomly divided into four groups: the control group (n = 5), the HAAM scaffolds group (n = 5), the JCFs group (n = 5), and the HAAM + JCFs group (n = 5). Macroscopic and histological assessments of the regenerated tissue were evaluated to validate the treatment results at 12 weeks. Results. In vitro, the HAAM scaffolds had a network structure and possessed abundant collagen. The HAAM scaffolds had good cytocompatibility, and hAMSCs grew well on the HAAM scaffolds. In vivo, the macroscopic scores of the HAAM + JCFs group were significantly higher than those of the other groups. In addition, histological assessments demonstrated that large amounts of hyaline-like cartilage formed in the osteochondral defects in the HAAM + JCFs group. Integration with surrounding normal cartilage and regeneration of subchondral bone in the HAAM + JCFs group were better than those in the other groups. Conclusion. HAAM scaffolds combined with JCFs promote the regenerative repair of osteochondral defects. Cite this article: Bone Joint Res 2022;11(6):349–361


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 78 - 78
1 Oct 2022
Cacciola G Bruschetta A Meo FD Cavaliere P
Full Access

Aim. The primary endpoint of this study is to characterize the progression of bone defects at the femoral and tibial side in patients who sustained PJI of the knee that underwent two-stage revision with spacer implantation. In addition, we want to analyze the differences between functional moulded and hand-made spacers. Methods. A retrospective analysis of patients that underwent two-stage revision due to PJI of the knee between January 2014 and December 2021 at our institution. Diagnosis of infection was based on the criteria of the Muscoloskeletal Infection Society. The bone defect evaluation was performed intraoperatively based on the AORI classification. The basal evaluation was performed at the time the resection arthroplasty and spacer implantation surgery. The final evaluation was performed at the second-stage surgery, at the time of spacer removal and revision implant positioning. The differences between groups were characterized by using T-test student for continuous variables, and by using chi-square for categorical variables. A p-value < 0.05 was defined as significant. Results. Complete data of 37 two-stage TKAs revision were included in the study. An articulating moulded functional spacer was used in 14 (35.9%) cases, while a hand-made spacer was used in 23 (58.9%) cases. The average length of interval period (excluding the time for patients that retained the spacer) was 146.6 days. A bone defects progression based on the AORI classification was documented in 24 cases at the femoral side (61.6%), a bone defect progression was documented in 17 cases at the tibial side (43.6%), and a bone defect at both sides was documented in 13 cases (33.3%). A statistically significant greater bone defect progression at the tibial side was observed when hand-made spacers were used. A complication during the interval period was reported in five cases (12.8%) and postoperative complication was reported in 9 cases (23.1%). Conclusions. When comparing patients in which a functional articulating spacer was used, with patients in which static spacer was used, we reported a statistically significant reduced bone defect progression during the interval period at the femoral side only when moulded spacers were used. We observed a higher incidence of bone defect progression also at the tibial and both sides when hand-made spacers were used. This is the first study that documented the bone defect progression during two-stage revision of the knee, the results observed in this study are very encouraging


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1723 - 1734
1 Dec 2020
Fung B Hoit G Schemitsch E Godbout C Nauth A

Aims. The purpose of this study was to: review the efficacy of the induced membrane technique (IMT), also known as the Masquelet technique; and investigate the relationship between patient factors and technique variations on the outcomes of the IMT. Methods. A systematic search was performed in CINAHL, The Cochrane Library, Embase, Ovid MEDLINE, and PubMed. We included articles from 1 January 1980 to 30 September 2019. Studies with a minimum sample size of five cases, where the IMT was performed primarily in adult patients (≥ 18 years old), in a long bone were included. Multivariate regression models were performed on patient-level data to determine variables associated with nonunion, postoperative infection, and the need for additional procedures. Results. A total of 48 studies were included, with 1,386 cases treated with the IMT. Patients had a mean age of 40.7 years (4 to 88), and the mean defect size was 5.9 cm (0.5 to 26). In total, 82.3% of cases achieved union after the index second stage procedure. The mean time to union was 6.6 months (1.4 to 58.7) after the second stage. Our multivariate analysis of 450 individual patients showed that the odds of developing a nonunion were significantly increased in those with preoperative infection. Patients with tibial defects, and those with larger defects, were at significantly higher odds of developing a postoperative infection. Our analysis also demonstrated a trend towards the inclusion of antibiotics in the cement spacer having a protective effect against the need for additional procedures. Conclusion. The IMT is an effective management strategy for complex segmental bone defects. Standardized reporting of individual patient data or larger prospective trials is required to determine the optimal implementation of this technique. This is the most comprehensive review of the IMT, and the first to compile individual patient data and use regression models to determine predictors of outcomes. Cite this article: Bone Joint J 2020;102-B(12):1723–1734


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_6 | Pages 6 - 6
1 Jun 2022
Turnbull G Shu W Picard F Clarke J
Full Access

As arthroplasty demand grows worldwide, the need for a novel cost-effective treatment option for articular cartilage (AC) defects tailored to individual patients has never been greater. 3D bioprinting can deposit patient cells and other biomaterials in user-defined patterns to build tissue constructs from the “bottom-up,” potentially offering a new treatment for AC defects. Novel composite bioinks were created by mixing different ratios of methacrylated alginate (AlgMA) with methacrylated gelatin (GelMA) and collagen. Chondrocytes and mesenchymal stem cells (MSCs) were then encapsulated in the bioinks and 3D bioprinted using a custom-built extrusion bioprinter. UV and double-ionic (BaCl2 and CaCl2) crosslinking was deployed following bioprinting to strengthen bioink stability in culture. Chondrocyte and MSC spheroids were also bioprinted to accelerate cell growth and development of ECM in bioprinted constructs. Excellent viability of chondrocytes and MSCs was seen following bioprinting (>95%) and maintained in culture, with accelerated cell growth seen with inclusion of cell spheroids in bioinks (p<0.05). Bioprinted 10mm diameter constructs maintained shape in culture over 28 days, whilst construct degradation rates and mechanical properties were improved with addition of AlgMA (p<0.05). Composite bioinks were also injected into in vitro osteochondral defects and crosslinked in situ, with maintained cell viability and repair of osteochondral defects seen over a 14-day period. In conclusion, we developed novel composite bioinks that can be triple-crosslinked, facilitating successful chondrocyte and MSC growth in 3D bioprinted scaffolds and in vitro repair of an osteochondral defect model. This offers hope for a new approach to treating AC defects


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 86 - 86
11 Apr 2023
Souleiman F Zderic I Pastor T Varga P Gueorguiev B Richards G Osterhoff G Hepp P Theopold J
Full Access

Osteochondral glenoid loss is associated with recurrent shoulder instability. The critical threshold for surgical stabilization is multidimensional and conclusively unknown. The aim of this work was to provide a well- measurable surrogate parameter of an unstable shoulder joint for the frequent anterior-inferior dislocation direction. The shoulder stability ratio (SSR) of 10 paired human cadaveric glenoids was determined in anterior-inferior dislocation direction. Osteochondral defects were simulated by gradually removing osteochondral structures in 5%-stages up to 20% of the intact diameter. The glenoid morphological parameters glenoid depth, concavity gradient, and defect radius were measured at each stage by means of optical motion tracking. Based on these parameters, the osteochondral stability ratio (OSSR) was calculated. Correlation analyses between SSR and all morphological parameters, as well as OSSR were performed. The loss of SSR, concavity gradient, depth and OSSR with increasing defect size was significant (all p<0.001). The loss of SSR strongly correlated with the losses of concavity gradient (PCC = 0.918), of depth (PCC = 0.899), and of OSSR (PCC = 0.949). In contrast, the percentage loss based on intact diameter (defect size) correlated weaker with SSR (PCC=0.687). Small osteochondral defects (≤10%) led to significantly higher SSR decrease in small glenoids (diameter <25mm) compared to large (≥ 25mm) ones (p ≤ 0.009). From a biomechanical perspective, the losses of concavity gradient, glenoid depth and OSSR correlate strong with the loss of SSR. Therefore, especially the loss of glenoidal depth may be considered as a valid and reliable alternative parameter to describe shoulder instability. Furthermore, smaller glenoids are more vulnerable to become unstable in case of small osteochondral loosening. On the other hand, the standardly used percentage defect size based on intact diameter correlates weaker with the magnitude of instability and may therefore not be a valid parameter for judgement of shoulder instability