Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 102 - 102
10 Feb 2023
White J Wadhawan A Min H Rabi Y Schmutz B Dowling J Tchernegovski A Bourgeat P Tetsworth K Fripp J Mitchell G Hacking C Williamson F Schuetz M
Full Access

Distal radius fractures (DRFs) are one of the most common types of fracture and one which is often treated surgically. Standard X-rays are obtained for DRFs, and in most cases that have an intra-articular component, a routine CT is also performed. However, it is estimated that CT is only required in 20% of cases and therefore routine CT's results in the overutilisation of resources burdening radiology and emergency departments. In this study, we explore the feasibility of using deep learning to differentiate intra- and extra-articular DRFs automatically and help streamline which fractures require a CT. Retrospectively x-ray images were retrieved from 615 DRF patients who were treated with an ORIF at the Royal Brisbane and Women's Hospital. The images were classified into AO Type A, B or C fractures by three training registrars supervised by a consultant. Deep learning was utilised in a two-stage process: 1) localise and focus the region of interest around the wrist using the YOLOv5 object detection network and 2) classify the fracture using a EfficientNet-B3 network to differentiate intra- and extra-articular fractures. The distal radius region of interest (ROI) detection stage using the ensemble model of YOLO networks detected all ROIs on the test set with no false positives. The average intersection over union between the YOLO detections and the ROI ground truth was Error! Digit expected.. The DRF classification stage using the EfficientNet-B3 ensemble achieved an area under the receiver operating characteristic curve of 0.82 for differentiating intra-articular fractures. The proposed DRF classification framework using ensemble models of YOLO and EfficientNet achieved satisfactory performance in intra- and extra-articular fracture classification. This work demonstrates the potential in automatic fracture characterization using deep learning and can serve to streamline decision making for axial imaging helping to reduce unnecessary CT scans


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 87 - 87
1 Aug 2020
Gusnowski E Schneider P
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54 degrees of flexion and 60 degrees of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and Disabilities of Arm, Shoulder and Hand (DASH) scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO-OTA distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO-OTA classification or a two-tailed independent samples t-tests for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05. After rigorous screening, six dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO-OTA classification versus six dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9 degrees, SD 9.3, n=257, volar 61.3 degrees, SD 11.5, n=1906) and extension (dorsal 60 degrees, SD 12, n=257, volar 62.8 degrees, SD 11.4, n=1906) were significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54). Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5-degrees, which is unlikely to be clinically significant. Additionally, there was no significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 105 - 105
1 Jul 2020
Gusnowski E Schneider P Thomas K
Full Access

Distal radius fractures (DRF) are the most common fracture type in all age groups combined. Unstable DRF may be surgically managed with volar or dorsal plate fixation. Dorsal plating has traditionally been associated with decreased range of motion (ROM). However, this assumption has not been recently assessed to determine whether functional ROM is achievable (approximately 54o of flexion and 60o of extension) with recent advances in lower profile dorsal plate design. The aim of this study was therefore to compare ROM and patient reported outcome measures between volar and dorsal plating methods for DRF. A meta-analysis was performed to directly compare ROM and DASH scores between dorsal and volar plate fixation for DRF. Separate literature searches for each plating method were performed using MedLine and EMBase on January 28, 2018. Exclusion criteria consisted of non-English articles, basic science articles, animal/cadaver studies, case studies/series, combined operative approaches, papers published more than 20 years ago and paediatric studies. Only articles with at least one year patient follow-up and a) ROM and AO distal radius fracture classification, or b) DASH scores were included. Raw data was extracted from all articles that met inclusion criteria to compile a comprehensive dataset for analysis. Descriptive statistics with z-score comparison for AO classification or a two-tailed independent samples t-test for ROM and DASH scores for dorsal versus volar plating were performed. Significance was defined as p < 0 .05. After rigorous screening, 6 dorsal plating and 43 volar plating articles met inclusion criteria for ROM/AO classification versus 6 dorsal plating and 44 volar plating articles for DASH scores. The weighted means of flexion (dorsal 54.9o, SD 9.3, n=257, volar 61.3o, SD 11.5, n=1906) and extension (dorsal 60.0o, SD 12, n=257, volar 62.8o, SD 11.4, n=1906) were statistically significantly different (both p < 0 .001) between the two plating methods. The volar plating group had a significantly higher proportion of AO type C fractures (dorsal 0.5, n =169, volar 0.6, n=1246, p < 0 .001). The weighted means of reported DASH scores were not significantly different between dorsal (14.01, SD 14.8) versus volar (13.6, SD 12.8) plating (p=0.54). Though mean wrist flexion and extension were statistically different between the dorsal versus volar plating methods, the difference between group means was less than 5o, which is unlikely to be clinically significant. Additionally, we did not find a significant difference in DASH scores between the two plating methods. Taken together, these findings imply that the statistical difference in ROM outcomes are likely not clinically significant and should therefore not dictate choice of plating method for fixation of DRF


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 18 - 18
1 Mar 2021
Perey B Chung K Kim H Malay S Shauver M
Full Access

To compare 24-month patient-reported outcomes after surgical treatment or casting in patients age 60 years of age or older with unstable distal radius fractures (DRF's). The Wrist and Radius Injury Surgical Trial (WRIST), is the largest randomized, multicenter trial in Hand Surgery, which enrolled 304 adults with isolated, unstable DRF's at 24 institutions. WRIST participants were followed for 24 months- longest follow-up among prospective studies comparing four treatment methods. Patients who agreed to surgical treatment (n=187) were randomized to internal fixation with volar plate (VLPS), external fixation, or percutaneous pinning; patients who preferred conservative management (n=117) received casting. The primary outcome was 24-month Michigan Hand Outcomes Questionnaire (MHQ) Summary score. Secondary outcomes were MHQ Domain scores. At 24-month assessment, participants' mean MHQ Summary score was 86 (95% CI: 83,88), representing good hand function. Participants reported good return of their Activities of Daily Living (ADLs) with a mean MHQ ADL score of 88 (95% CI: 85,91). Finally, participants were satisfied, with a mean MHQ Satisfaction score of 84 (95% CI: 80,88). There were no significant differences in score by treatment group in any MHQ domain at 24 months. Six weeks after surgery, VLPS participants scored significantly higher than the other three groups on (ADLs) and Satisfaction (both p<0.0001), whereas participants who received external fixation scored significantly lower than the casting and VLPS groups on the same domains. By the 3-month assessment, the gap between VLPS and casting had disappeared but external fixation participants continued to report significantly worse scores. External fixation participants did not report comparable ADL scores to the other three groups until 12 months after surgery. Participants reported good outcomes 24 months after DRF regardless of treatment. Casting and VLPS are both acceptable treatments for older adults. The decision between the two treatments should be made considering patient goals regarding recovery speed and desire to avoid surgical risks. External fixation should be avoided because of worse outcomes in the year after surgery and the risk of pin site infections


Distal radius fractures (DRF) are common and the indication for surgical treatment remain controversial in patients higher than 60 years old. The purpose of the study was to review and analyze the current evidence-based literature. We performed a systematic review and meta-analysis according to PRISMA guidelines in order to evaluate the efficacy of volar locking plating (VLP) and conservative treatment in DRF in patients over 60 years old. Electronic databases including MEDLINE, CENTRAL, Embase, Web of science and Clinical Trial.gov were searched from inception to October 2020 for randomized controlled trials. Relevant article reference lists were also passed over. Two reviewers independently screened and extracted the data. Main outcomes included functional status: wrist range of motion, validated scores and grip strength. Secondary outcomes include post-operative complications and radiologic assessment. From 3009 screened citations, 5 trials (539 patients) met the inclusion criteria. All trials of this random effect meta-analysis were at moderate risk of bias due to lack of blinding. Differences in the DASH score (MD −5,91; 95% CI, −8,83; −3,00), PRWE score (MD −9.07; 95% CI, −14.57, −3.57) and grip strength (MD 5,12; 95% CI, 0,59-9,65) were statistically significant and favored VLPs. No effect was observed in terms of range of motion. Adverse events are frequent in both treatment groups, reoperation rate is higher in the VLP group. VLP may provide better functional outcomes in patients higher than 60 years old. More RCT are still needed to evaluate if the risks and complications of VLP outweigh the benefits


Distal radius fractures (DRF) are common and the indication for surgical treatment remain controversial in patients higher than 60 years old. The purpose of the study was to review and analyze the current evidence-based literature. We performed a systematic review and meta-analysis according to PRISMA guidelines in order to evaluate the efficacy of volar locking plating (VLP) and conservative treatment in DRF in patients over 60 years old. Electronic databases including MEDLINE, CENTRAL, Embase, Web of science and Clinical Trial.gov were searched from inception to October 2020 for randomized controlled trials. Relevant article reference lists were also passed over. Two reviewers independently screened and extracted the data. Main outcomes included functional status: wrist range of motion, validated scores and grip strength. Secondary outcomes include post-operative complications and radiologic assessment. From 3009 screened citations, 5 trials (539 patients) met the inclusion criteria. All trials of this random effect meta-analysis were at moderate risk of bias due to lack of blinding. Differences in the DASH score (MD −5,91; 95% CI, −8,83; −3,00), PRWE score (MD −9.07; 95% CI, −14.57, −3.57) and grip strength (MD 5,12; 95% CI, 0,59-9,65) were statistically significant and favored VLPs. No effect was observed in terms of range of motion. Adverse events are frequent in both treatment groups, reoperation rate is higher in the VLP group. VLP may provide better functional outcomes in patients higher than 60 years old. More RCT are still needed to evaluate if the risks and complications of VLP outweigh the benefits


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 72 - 72
1 Dec 2022
Kendal J Fruson L Litowski M Sridharan S James M Purnell J Wong M Ludwig T Lukenchuk J Benavides B You D Flanagan T Abbott A Hewison C Davison E Heard B Morrison L Moore J Woods L Rizos J Collings L Rondeau K Schneider P
Full Access

Distal radius fractures (DRFs) are common injuries that represent 17% of all adult upper extremity fractures. Some fractures deemed appropriate for nonsurgical management following closed reduction and casting exhibit delayed secondary displacement (greater than two weeks from injury) and require late surgical intervention. This can lead to delayed rehabilitation and functional outcomes. This study aimed to determine which demographic and radiographic features can be used to predict delayed fracture displacement. This is a multicentre retrospective case-control study using radiographs extracted from our Analytics Data Integration, Measurement and Reporting (DIMR) database, using diagnostic and therapeutic codes. Skeletally mature patients aged 18 years of age or older with an isolated DRF treated with surgical intervention between two and four weeks from initial injury, with two or more follow-up visits prior to surgical intervention, were included. Exclusion criteria were patients with multiple injuries, surgical treatment with fewer than two clinical assessments prior to surgical treatment, or surgical treatment within two weeks of injury. The proportion of patients with delayed fracture displacement requiring surgical treatment will be reported as a percentage of all identified DRFs within the study period. A multivariable conditional logistic regression analysis was used to assess case-control comparisons, in order to determine the parameters that are mostly likely to predict delayed fracture displacement leading to surgical management. Intra- and inter-rater reliability for each radiographic parameter will also be calculated. A total of 84 age- and sex-matched pairs were identified (n=168) over a 5-year period, with 87% being female and a mean age of 48.9 (SD=14.5) years. Variables assessed in the model included pre-reduction and post-reduction radial height, radial inclination, radial tilt, volar cortical displacement, injury classification, intra-articular step or gap, ulnar variance, radiocarpal alignment, and cast index, as well as the difference between pre- and post-reduction parameters. Decreased pre-reduction radial inclination (Odds Ratio [OR] = 0.54; Confidence Interval [CI] = 0.43 – 0.64) and increased pre-reduction volar cortical displacement (OR = 1.31; CI = 1.10 – 1.60) were significant predictors of delayed fracture displacement beyond a minimum of 2-week follow-up. Similarly, an increased difference between pre-reduction and immediate post reduction radial height (OR = 1.67; CI = 1.31 – 2.18) and ulnar variance (OR = 1.48; CI = 1.24 – 1.81) were also significant predictors of delayed fracture displacement. Cast immobilization is not without risks and delayed surgical treatment can result in a prolong recovery. Therefore, if reliable and reproducible radiographic parameters can be identified that predict delayed fracture displacement, this information will aid in earlier identification of patients with DRFs at risk of late displacement. This could lead to earlier, appropriate surgical management, rehabilitation, and return to work and function


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 68 - 68
1 Oct 2012
Beretta E Valenti M De Momi E Ferrigno G
Full Access

The location of the hip joint center (HJC) allows correct prosthesis aligning and positioning in Computer-Assisted Orthopaedic Surgery (CAOS) applications. For the kinematic HJC localisation, the femur is moved around the pelvis with ad hoc motion trials (“pivoting”). The “Pivoting algorithm” [Siston et al., J Biomech 39 (2006) 125–130] is the functional state-of-the-art method for the hip center localisation. A source of systematic error in HJC localisation algorithms is represented by the pelvis motion during the pivoting. In computer assisted total knee arthroplasty applications, the pelvis pose is not acquired during passive movements. In motion capture applications, Kalman Filter (KF) methodology was used to estimate the pose of hidden segment for rigid body pose estimation. The purpose of this study was to validate the accuracy and robustness of a Kalman Filter algorithm, applied to a state space formulation based on two links model of the hip joint, to track the HJC position during passive movements of the articulation in CAOS procedure. The state space model describes femur and pelvis kinematics under the hypothesis of non-laxity of the articulation (ideal spherical joint). The first link models the femoral bone, while the second link models the pelvis. The femur is tracked with a Dynamic Reference Frame (DRF) attached to the distal end, composed by four active markers, while the pelvis is tracked attaching a marker to it. The kinematic relations between the state vector and the observations are non linear function. The state space has been implemented with II order linear dynamics. The position of HJC in the Femur Reference Frame is modeled with non-dynamic state variables. In order to validate the proposed algorithm, a physical model of the hip joint (femur and pelvis) was realised using SawBones models. An active optical localisation system (Certus, NDI, Ontario, Canada) was used in order to track the coordinates of two DRF rigidly connected on each segment and the coordinates of a marker attached to the pelvis segment (on the Anterior Superior Iliac Spine ASIS). The pelvis phantom is locked on a Mass-Spring-Damper platform with 2 DoFs, which mimics soft tissues behaviour. During the pivoting motion, the poses of the femur DRF and the positions of the ASIS marker of the pelvis DRF were collected. The acquired data were the observable outputs to the KF algorithm, which computes an estimation of the state parameters. The accuracy is evaluated as the Euclidean distance between respectively the estimated and Gold Standard HJC positions in FRF. The KF method performances were compared with the “Pivoting” algorithm. The localisation errors computed for both the methodologies were evaluated with respect to the HJC translation, to the Range Of pivoting Motion (ROM) and to the velocity of femur DRF trajectory (Pearson correlation analysis). The positive correlation coefficients between HJC translation and the localization errors result statistically significant (p<0.01) for both “Pivoting” (correlation index equal to 0.838) and KF (correlation index equal to 0.415) algorithms; while a negative (correlation index equal to −0.355) and positive (correlation index equal to 0.263) correlation respectively for ROM and Velocity is computed as statistically significant (p<0.05) only for KF algorithm errors. Statistically significant difference (Kruskal-Wallis, p<0.01) between “Pivoting” [median 26.71 mm and inter-quartile range (24.04, 32.18)mm] and KF [median 11.71mm and inter-quartile range (7.74, 18.82)mm] algorithms was assessed for HJC translation greater than 7 mm. The new method KF proved to be applicable in current CAOS systems. The substantial improvement of KF method is the possibility of reducing the systematical error, caused by pelvis motion during passive movement of the femur, to compute HJC position. On the other hand, tracking the HJC trajectory in real time is a nontrivial task and requires a very accurate filter parameters tuning. Further tests must be made to estimate the in-vivo range of HJC translation during passive pivoting movements and evaluate the performances of KF method with respect to others state-of-the-art methods


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 149 - 149
1 Jan 2013
Manelius I McQueen M Biant L
Full Access

Distal radius fractures are common, yet the long-term functional outcome of these patients is unknown. This study investigated the long-term functional outcomes after distal radius fracture (DRF) in adult patients 16–23 years following injury. Secondary aims were to establish morbidity, mortality and function related to pattern of injury and patient demographics. Methods. 622 consented adult patients with a DRF were enrolled in the study. Prospective data was recorded; patient age, mechanism of injury and fracture pattern. Patients were assessed 16–23 years post-injury. 275 patients were deceased. 194 patients were able to complete a Quick Dash (QD) validated upper limb pain and function Patient-Reported Outcome Measure (PROM). Five patients declined follow-up. Socioeconomic status was assessed using the Scottish Index of Multiple Deprivation (SIMD) 2009. Results. The mean age at injury was 41 years for men and 64 for women in the initial cohort. 146 women and 48 men completed final follow-up. The mean age at QD assessment was 57 years for men and 76 for women; mean and median SIMD deciles were 6.7 and 7, respectively, for both genders. The mean QD score was 10.35 for all patients, with no significant gender difference (p=0.63). 85.6% (n=166) reported no or at most, mild limitation. High socioeconomic status, absence of other injuries at DRF and age under 85 years old at follow-up was associated with better long-term function. Early function and pain predicted long-term function; comminution pattern, treatment modality as chosen by surgeon, and early complications did not. Mortality data was analysed for the deceased (n=275). The mean patient survival from DRF to death was 11 years 5 months, with no significant gender difference (p=0.43); survival was predicted by age at injury, post-treatment dorsal angulation and early function. Respiratory, cardiovascular causes and malignancy were the three most common primary causes of death


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 87 - 87
1 Jul 2020
Ashjaee N Johnston G Johnston J
Full Access

Distal radius fracture is one of the most common fractures in older women (∼70,000 cases annually in Canada). Treatment of this fracture has been shifting toward surgery (mainly volar locking plate (VLP) technology), which significantly enhances surgeon's ability to maintain correction. However, current surgical outcomes are far from perfect. There is a need for an implant which maintains the corrected position (reduction), minimizes soft tissue disruption, and is technically easy to perform. A novel internal, composite-based implant was designed to achieve these ends. It is unclear, however, whether this novel implant offers similar fracture fixation as the VLP. As such, the objective of this research was to evaluate the fracture stability (assessed by calculating change in fracture length) of the novel implant and VLP under cyclic fatigue loading. Specimens: Seven radius specimens derived from older female cadavers (mean = 82.3 years, SD = 11.3 years) were used for the experiment. Preparation: A standardized dorsal wedge was removed from the cortex. The distance from the proximal and distal transverse osteotomies was 10 mm and was positioned 20 mm proximal to the tip of the radial styloid. The osteotomy removed all load-bearing capabilities of bone, equivalent to a worst-case-scenario for DRF fixation. Simulated Loading: The proximal end of the radii was potted (fixed) and positioned in a material testing system. To mimic natural loading conditions, hands were cycled between −30°/30° flexion/extension, at 0.5 Hz, for 2000 cycles, while tension load was applied to the tendons (25-N constant force per tendon, 100-N in total). Mechanical testing outcomes: A position tracking sensor used to measure change in fracture length. This change, as a function of number of cycles, was used to assess implant resistance to fatigue loading. Statistical Analysis: A paired student t-test was used to compare the change in fracture length. Level of significance was determined as 5% (p < 0.05). Changes in fracture fracture-length for both the novel implant and plate is shown in Table 1. The paired t-test indicated significant differences between the two groups in terms of change in fracture length (p = 0.026). The outcome of the novel implant ranged from very stable (change in fracture-length = 0.01 mm) to highly un-stable (2.88 mm). We believe the reason for this variance, at least in part, originates from the surgical procedures. Presumably, given that one very strong stabilization (0.01 mm) and one acceptable stabilization (0.37 mm) was obtained, future research directed towards surgical procedures may improve fracture stability. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 134 - 134
1 Sep 2012
Drager J Carli A Matache B Harvey EJ
Full Access

Purpose. Conservative treatment of minimally displaced distal radius fractures (DFR) remains controversial. Circumferential casting (CC) in the acute setting is believed to supply superior support compared to splinting, but is generally cautioned due to the limited capacity of a cast to accommodate ongoing limb swelling possibly leading to complications. However, there is no conclusive data on which to base these beliefs. Moreover, the appropriate management of cast complications while minimizing risk to fracture integrity remains unclear. This retrospective study of distal radius fractures treated conservatively with circumferential cast in the acute setting aims to: A. Determine demographic, fracture dependant or management risk factors for CC complications. B. Determine the natural history for both patients with CC and those with CC necessitating cast modification. Method. Hospital records and radiographic data of 316 patients with DRFs treated with CC at a tertiary-care university hospital between the years 2006 to 2009 were reviewed. Our primary outcome was to access risk factors for cast complications including swelling, pressure sores, neuropathies and loss of cast immobilization. Our secondary outcome accessed reduction stability in patients undergoing cast re-manipulation. Results. 31% of patients experienced cast related complications within the first two weeks of treatment. 22% of patients had their cast manipulated (replaced, split, trimmed or windowed). Increasing patient age or polytrauma were both associated with an increased risk of developing cast complications. Polytrauma was also associated with a poor overall rate of fracture reduction following non-operative management. Patient gender, physician specialty placing the cast as well as fracture type (AO classification) did not influence risk. Overall, patients with acute cast complications had no increased risk of losing reduction compared to patients with normal management. However, patients who complained of pressure in cast had a higher risk of loss reduction if their cast was split as opposed to being replaced. Conclusion. Circumferential casting in the acute setting of minimally displaced DRF reduces the workload of an orthopedic department. No previous study has shown improved fracture outcome compared to CC using other immobilization methods. This study has identified that elderly patients and polytrauma patients are at greater risk of returning to clinic for cast complications. Furthermore, replacing a cast as opposed to splitting it when accommodating painful swelling may aid in maintaining reduction integrity


Bone & Joint Open
Vol. 1, Issue 9 | Pages 549 - 555
11 Sep 2020
Sonntag J Landale K Brorson S Harris IA

Aims

The aim of this study was to investigate surgeons’ reported change of treatment preference in response to the results and conclusion from a randomized contolled trial (RCT) and to study patterns of change between subspecialties and nationalities.

Methods

Two questionnaires were developed through the Delphi process for this cross-sectional survey of surgical preference. The first questionnaire was sent out before the publication of a RCT and the second questionnaire was sent out after publication. The RCT investigated repair or non-repair of the pronator quadratus (PQ) muscle during volar locked plating of distal radial fractures (DRFs). Overall, 380 orthopaedic surgeons were invited to participate in the first questionnaire, of whom 115 replied. One hundred surgeons were invited to participate in the second questionnaire. The primary outcome was the proportion of surgeons for whom a treatment change was warranted, who then reported a change of treatment preference following the RCT. Secondary outcomes included the reasons for repair or non-repair, reasons for and against following the RCT results, and difference of preferred treatment of the PQ muscle between surgeons of different nationalities, qualifications, years of training, and number of procedures performed per year.