Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 35 - 35
1 Nov 2021
Hartland A Islam R Teoh K Rashid M
Full Access

Introduction and Objective. There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. Materials and Methods. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included visual analogue scale (VAS), rate of cosmetic deformity (Popeye sign), range of motion, operative time, and elbow flexion strength. Results. 751 patients from 10 RCTs demonstrated (369 tenotomy vs 382 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.17 95% CI −0.02 to 0.36, p=0.09). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. Secondary outcomes including VAS, shoulder external rotation, and elbow flexion strength did not reveal any significant difference. Tenodesis resulted in a lower rate of Popeye deformity (OR 0.27 95% CI 0.16 to 0.45, p<0.00001). Conclusions. Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. This finding was irrespective of the whether the rotator cuff was intact


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 64 - 64
4 Apr 2023
Hartland A Islam R Teoh K Rashid M
Full Access

There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included pain (visual analogue scale VAS), rate of Popeye deformity, and operative time. 860 patients from 11 RCTs (426 tenotomy vs 434 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.14, 95% CI −0.04 to 0.32; p=0.13). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. There was no significant difference for pain (VAS). Tenodesis resulted in a lower rate of Popeye deformity (OR 0.29, 95% CI 0.19 to 0.45, p < 0.00001). Tenotomy demonstrated a shorter operative time (MD 15.21, 95% CI 1.06 to 29.36, p < 0.00001). Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. A large multi-centre clinical effectiveness randomised controlled trial is needed to provide clarity in this area


Cubitus varus following paediatric supra-condylar humeral fracture represents a complex three-dimensional malunion. This affects cosmesis, function and subsequent distal humeral fracture risk. Operative correction is however difficult with high complication rates. We present the 40-year Yorkhill experience of managing this deformity. From a total of 3220 supracondylar humeral fractures, 40 cases of post-traumatic cubitus varus were identified. There were ten undisplaced fractures, treated in cast, and thirty displaced fractures. Five were treated in cast, thirteen manipulated (MUA), four MUA+k-wires, seven ORIF (six k-wire, one steinman pin) and one in skeletal-traction. Sixteen malunions were treated operatively. The mean pre-operative varus was 19°. All had cosmetic concerns, three mild pain, one paraesthesia/weakness and three reduced movement (ROM). The operative indication was cosmetic in fifteen and functional in one (concern about instability). Twelve patients had lateral closing-wedge osteotomies; three complex/3D osteotomies (dome, unspecified rotational, antero-lateral wedge) and two had attempted 8-plate guided-growth correction. Complications occurred in eight patients (50 %): Fixation was lost in three (two staples, one k-wiring), incomplete correction in six (both 8-plates, both staples, two standard plates) and one early wound infection requiring metalwork removal resulting in deformity recurrence. One patient underwent revision lateral wedge osteotomy with full deformity correction but marked ROM restriction (20–100°) secondary to loose bodies. Those without complications were satisfied (50 %). All patients with residual deformity were unsatisfied. 1 patient with keloid scarring was unsatisfied despite deformity correction. Varus malunion is uncommon (1 %) but needs to be guarded against. It tended to occur in displaced fractures treated with MUA and cast alone. We therefore recommend additional pin fixation in all displaced fractures. Deformity correction should only be attempted in those with significant symptomatic deformity due to the high complication/dissatisfaction rates. Staple osteotomy fixation and 8-plate guided growth correction are not recommended


Bone & Joint 360
Vol. 11, Issue 5 | Pages 46 - 47
1 Oct 2022
Das A


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 65 - 65
1 May 2017
Alzahrani M Cota A Alkhelaifi K Harvey E
Full Access

Background. Open reduction and internal fixation using plate osteosynthesis for midshaft clavicle fractures is often associated with hardware prominance. Although clinical studies have suggested a role for the use of thinner 2.7mm plates as a means of increasing cosmetic acceptability this still remains an area of controversy. We investigated the effect of plate size (2.7mm vs. 3.5mm), plate treatment (annealed vs. cold worked) and number of screws on the stiffness and yield point. Methods. Twenty-four synthetic clavicles were randomly divided into four treatment groups - Synthes (Synthes, Paoli, PA) 2.7mm cold-worked calcaneal reconstruction plate with six or eight bicortical screws; 3.5mm LCP reconstruction plate (RP) and 3.5mm LCP pre-contoured superior-anterior clavicle plate (PCSA). After measuring the baseline stiffness of the intact specimens, all clavicles were plated, a wedge-shaped inferior defect was created and testing performed using a cantilever-bending model. Statistical analysis was performed using one-way ANOVA with Tukey's multiple comparison test with significance set at a P value <0.05. Results. The 3.5mm RP construct was significantly stiffer than both of the 2.7mm CR constructs (P < 0.0001). The yield point for the 3.5mm PCSA construct was greater than the other three constructs (P < 0.0001), while the yield point for the 2.7mm CR plate with 6 screws and with 8 screws was higher than the 3.5mm RP construct (P = 0.0002 and P = 0.0023 respectively). The amount of displacement required to reach the yield point was highest for the 2.7mm CR plate with six screws and this was significantly higher than the values for the other three constructs. Conclusion. The 3.5mm plates demonstrated increased bending stiffness compared to the 2.7mm plates. Despite the lower resistance to bending forces, the cold worked 2.7mm plate exhibited a significantly higher yield point and required significantly more superior to inferior displacement to deform


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 520 - 526
1 Apr 2008
Yau WP Leung A Liu KG Yan CH Wong LS Chiu KY

We have investigated the errors in the identification of the transepicondylar axis and the anteroposterior axis between a minimally-invasive and a conventional approach in four fresh-frozen cadaver knees. The errors in aligning the femoral prosthesis were compared with the reference transepicondylar axis as established by CT.

The error in the identification of the transepicondylar axis was significantly higher in the minimal approach (4.5° of internal rotation, sd 4) than in the conventional approach (3° of internal rotation, sd 4; p < 0.001). The errors in identifying the anteroposterior axis in the two approaches were 0° (sd 5) and 1.8° (sd 5) of internal rotation, respectively (p < 0.001).


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 971 - 976
1 Jul 2007
Kampa RJ Prasthofer A Lawrence-Watt DJ Pattison RM

In order to determine the potential for an internervous safe zone, 20 hips from human cadavers were dissected to map out the precise pattern of innervation of the hip capsule. The results were illustrated in the form of a clock face. The reference point for measurement was the inferior acetabular notch, representing six o’clock. Capsular branches from between five and seven nerves contributed to each hip joint, and were found to innervate the capsule in a relatively constant pattern. An internervous safe zone was identified anterosuperiorly in an arc of 45° between the positions of one o’clock and half past two.

Our study shows that there is an internervous zone that could be safely used in a capsule-retaining anterior, anterolateral or lateral approach to the hip, or during portal placement in hip arthroscopy.