Advertisement for orthosearch.org.uk
Results 1 - 20 of 63
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1369 - 1374
1 Oct 2005
Athwal GS Chin PY Adams RA Morrey BF

We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months (1 to 192). Five patients (25%) were alive at the final follow-up; 14 (70%) had died of their disease and one of unrelated causes. Local control was achieved in 15 patients (75%). The mean Mayo Elbow Performance Score improved from 22 (5 to 45) to 75 points (55 to 95). Four reconstructions (20%) failed and required revision. Seven patients (35%) had early complications, the most frequent being nerve injury (25%). There were no infections or wound complications although 18 patients (90%) had radiotherapy, chemotherapy or both. The Coonrad-Morrey total elbow arthroplasty provides good relief from pain and a good functional outcome after resection of tumours of the elbow. The rates of complications involving local recurrence of tumour (25%) and nerve injury (25%) are of concern


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 509 - 514
1 Apr 2006
Aldridge JM Lightdale NR Mallon WJ Coonrad RW

There have been few reports in the literature of total elbow arthroplasty extending beyond 10 to 15 years. We reviewed 40 patients (41 elbows) with a mean age of 56 years (19 to 83) who had undergone a Coonrad/Coonrad-Morrey elbow arthroplasty by one surgeon for various diagnoses between 1974 and 1994. Surgical selection excluded patients with previous elbow infection or who refused to accept a sedentary level of elbow activity postoperatively. Objective data were collected from charts, radiographs, clinical photographs and supplemented by the referring orthopaedic surgeons’ records and radiographs if health or distance prevented a patient from returning for final review. Subjective outcome was defined by patient satisfaction. Of the 41 elbows, 21 were functional between 10 and 14 years after operation, ten between 15 and 19 years and ten between 20 and 31 years. There were 14 complications and 13 revisions, but no cases of acute infection, or permanent removal of any implant


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 47
1 Mar 2002
Mansat P Head S Rongières M Bellumore Y Bonnevialle P Mansat M
Full Access

Purpose: We report our experience with 23 Coonrad-Morrey total elbow prostheses. Material and methods: Between July 1997 and February 2001, we implanted 34 Coonrad-Morrey total elbow pros-theses in 33 patients. Twenty-three patients (23 implants) were reviewed at a mean 24 months follow-up, maximum 40 months. There were three men and 20 women, mean age 62 years (42–69). Twelve patients had rheumatoid polyarthritis, the principal indication. There were also four recent fractures of the distal humerus, two nonunions, and one patient with post-traumatic osteoarthritis. One patient had sequelar osteoarthritis since childhood. Finally three revisions were performed for loosening of a GUEPAR prosthesis in two cases and a GSBIII prosthesis in one. Results were assessed with the Mayo Clinic score. We searched for lucent lines around the implants, polyethylene wear, and incorporation of the bone graft behind the anterior wing of the implant on plain radiographs. Results: At last follow-up, the mean Mayo Clinic score had improved from 25 to 89 points (70–100). Before surgery, 17 patients had severe pain. At last follow-up, eight patients had occasional pain. Extension was improved by 10°, flexion by 27° giving a postoperative amplitude of 29° to 132°. Prona-tion supination progressed by 37° giving a rotation amplitude of 127°. The function score improved from 4 to 21 points. Sixteen of the 23 patients had normal elbow function. Outcome was excellent in 13 patients, good in eight, and fair in two. There were no lucent lines visible on the radiographs. There was no sign of polyethylene wear. The bon graft was incorporated behind the implant in 20 cases and was not visible in three. Complications included one peroperative fracture, one cutaneous dehiscence, one post-operative fracture of the olecranon due to a fall, and persistent ulnar paresthesia in four patients requiring secondary neurolysis in one. Discussion, conclusion: The Coonrad-Morrey semi-constrained prosthesis provides a response to a large range of situations. The dominant indication is rheumatoid polyarthritis, but trauma patients can benefit from this reliable therapeutic solution giving a satisfactory rate of success. A satisfactory functional amplitude is generally achieved with this implant and the elbow is generally pain free


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 59 - 59
1 Jan 2004
Delattre O Dintimille H Gottin M Rouvillain J Catonne Y
Full Access

Purpose: Loosening remains a problem with semi-constrained total elbow prostheses. The trend in recent years has been to improve prosthesis design to achieve stability of the humeral implant. We report a small series of nine Coonrad-Morrey total elbow prostheses where three early loosenings were observed in the ulnar implant. We attempt to analyse the causes and present a review of the recent literature. Material and methods: Nine patients, mean age 60 years, age range 57–63 years, underwent total elbow arthroplasty with a Coonrad-Morrey prosthesis for rheumatoid disease (n=5), stiff degenerative joints after trauma (n=3, flexion-extension 20°), floating joint after trauma (n=1). The posterolateral approach described by Bryan and Morrey was used for eight elbows and the posterior approach for one. Clinical and radiological results were assessed with the performance index and the Mayo clinic score respectively. Results: Mean follow-up was 3.6 years (1.5–4.7). Outcome was very good or good for seven elbows (score > 75 and > 50), fair for one (< 50) and poor for one (< 25). Three elbows were pain free, two presented pain during movement against force. Flexion was greater than 120° in four elbows (all four rheumatoid polyarthritis). Radiologically, we observed three cases of ulnar implant loosening with two type IV lucent lines, and one type III line. There was one humeral implant with a lucent line which did not change over time (type I). The two cases of type IV lines were associated with radial and anterior translation migration of the prosthetic stem with effraction or lysis of the ulnar cortical. The three ulnar loosenings appeared between the second and third postoperative year on two post-trauma stiff degenerative elbows (flexion-extension < 20°) and one rheumatoid elbow. At last follow-up, there was one poor result requiring revision surgery, one fair result, and one very good result (totally asymptomatic type 4 lucent line). Discussion: The causes of these loosenings were studied: difficult cementing technique in a tight canal, mediocre primary stability of the ulnar implant opposing the excellent fit of the humeral implant with an encased graft under the anterior wing, excessive constraint. Our results are similar to those reported by Hilebrand who had 30% evolving ulnar lucent lines and suggest that we should reserve this prosthesis for unstable elbows


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 381 - 386
1 Mar 2016
Prasad N Ali A Stanley D

Aims. We review our experience of Coonrad-Morrey total elbow arthroplasty (TEA) for fractures of the distal humerus in non-rheumatoid patients with a minimum of ten years follow-up. Patients and Methods. TEA through a triceps splitting approach was peformed in 37 non-rheumatoid patients for a fracture of the distal humerus between 1996 and 2004. One patient could not be traced and 17 had died before the tenth anniversary of their surgery. This left 19 patients with a minimum follow-up of ten years to form the study group. Of these, 13 patients were alive at the time of final review. The other six had died, but after the tenth anniversary of their elbow arthroplasty. Their clinical and radiological data were included in the study. . Results. The mean follow-up of the 19 patients was 156 months (120 to 210). Two patients in the study group had undergone revision. One further patient had undergone a two-stage revision for infection but died before ten-year follow-up. Six other patients in the study group had evidence of loosening or wear of their bushings. Two were clinically symptomatic and were offered revision surgery. Male patients showed higher incidence of loosening and wear. Survivorship, with revision and definite loosening as end-points, was 89.5% at ten years in those patients followed for a minimum of ten years and 86% in the whole group of 36 patients. Conclusion. This study shows that only 53% of non-rheumatoid patients who undergo TEA for a fracture of the distal humerus survive to the tenth anniversary of their index procedure. For those that survive, TEA provides acceptable outcomes in terms of function and implant survival. Take home message: The surgeons undertaking these procedures should be aware of the long-term revision rates and also the gender difference in the rates of loosening. Cite this article: Bone Joint J 2016;98-B:381–6


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 102 - 102
1 Mar 2012
Sivardeen Z Ali A Thiagarajah S Kato H Stanley D
Full Access

Total elbow arthroplasty (TEA) has been shown to be a treatment option for elderly patients with complex distal humeral fractures and osteoporotic bone. The published results have often included rheumatoid patients who traditionally would be expected to do well from elbow arthroplasty. Only short-term results have been published using this technique in non-rheumatoid patients.

The current study contains the largest number and longest follow-up of non-rheumatoid patients whose fractures have been treated with a non-custom TEA. In total there were 26 patients, mean age 72 years, 22 female and 4 male, 25% dominant arm. The mean follow-up was of 5 years. There was 1 case of loosening, 1 radial nerve palsy and 2 cases of heterotrophic ossification. At final review the mean range of flexion/extension was 97.5 degrees and the mean range of pronation/supination was 151.75 degrees. The mean Mayo Elbow Performance score was 92.

We would suggest that TEA provides a very satisfactory outcome in elderly patients with complex distal humeral fractures, the benefit of which can be observed at a mean of 5 years.


Bone & Joint 360
Vol. 13, Issue 5 | Pages 34 - 37
1 Oct 2024

The October 2024 Shoulder & Elbow Roundup360 looks at: Proximal humeral fractures with vascular compromise; Outcomes and challenges of revision arthroscopic rotator cuff repair: a systematic review; Evaluating treatment effectiveness for lateral elbow tendinopathy: a systematic review and network meta-analysis; Tendon transfer techniques for irreparable subscapularis tears: a comparative review; Impact of subscapularis repair in reverse shoulder arthroplasty; Isolated subscapularis tears strongly linked to shoulder pseudoparesis; Nexel and Coonrad-Morrey total elbow arthroplasties show comparable revision rates in New Zealand study; 3D MRI matches 3D CT in assessing bone loss and shoulder morphology in dislocation cases


Bone & Joint 360
Vol. 11, Issue 6 | Pages 31 - 34
1 Dec 2022

The December 2022 Shoulder & Elbow Roundup. 360. looks at: Biceps tenotomy versus soft-tissue tenodesis in females aged 60 years and older with rotator cuff tears; Resistance training combined with corticosteroid injections or tendon needling in patients with lateral elbow tendinopathy; Two-year functional outcomes of completely displaced midshaft clavicle fractures in adolescents; Patients who undergo rotator cuff repair can safely return to driving at two weeks postoperatively; Are two plates better than one? A systematic review of dual plating for acute midshaft clavicle fractures; Treatment of acute distal biceps tendon ruptures; Rotator cuff tendinopathy: disability associated with depression rather than pathology severity; Coonrad-Morrey total elbow arthroplasty implications in young patients with post-traumatic sequelae


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 78 - 83
1 Jan 2006
Sneftrup SB Jensen SL Johannsen HV Søjbjerg JO

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 points (40 to 100) at the latest follow-up. There was a marked relief of pain, but the range of movement showed no overall improvement. Two patients had a second revision because of infection and two for aseptic loosening. The estimated five-year survival rate of the prosthesis was 83.1% (95% confidence interval 61.1 to 93.3). Revision elbow arthroplasty using the Coonrad-Morrey implant provided satisfactory results but with complications occurring in 13 cases


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 2 - 2
1 Mar 2013
Alizadehkhaiyat O Vishwanathan K Frostick S Al Mandhari A
Full Access

Background. The quest for the perfectly designed elbow prosthesis continues as instability and loosening remain the foremost reasons for the failure of total elbow replacement (TER). The Discovery® Elbow System (Biomet, UK) (Figure 1), which has been used in UK since 2003, is one of the latest generations of linked prosthesis. This system was designed to decrease polyethylene-bushing wear, improve anatomic stem design, restore elbow joint biomechanics, and produce a hinge that could be easily revised. This report describes the short term outcome of TER using the Discovery® Elbow System. Patients and Methods. A total of 60 TERs including 48 primary and 12 revisions were performed between 2003 and 2008. Patients included 21 males (37%) and 36 females (63%) with a mean age of 63 years. The indications for primary TER were advanced rheumatoid arthritis (n=19), osteoarthritis (n=16), post traumatic osteoarthritis (n=9), acute fractures (n=3), and haemophilic arthropathy (n=1). The outcome was assessed using pain score, Liverpool Elbow Score (LES), and range of movement during a mean follow-up of 26 months. Associated complications were documented. Radiological assessment included evaluation for loosening, instability and periprosthetic fractures. Results. The mean LES was significantly (p<0.001) improved from 3.8 (±1) pre-operatively to 6.9 (±2) at the final follow- up. Significant improvements were noted in elbow flexion from 100° (±22) to 120° (±15), supination from 41° (±28) to 65° (±20) and pronation from 52° (±22) to 72° (±18). There was no significant change in elbow extension. Mean improvement in flexion-extension and pronation-supination arc was 22° and 44°, respectively. 46 cases (77%) were completely pain-free at the final follow-up. The main complications included deep infection (4 cases – treated with staged revision TER), postoperative ulnar neuropathy (3 cases–treated with decompression), intra-operative fractures of medial condyle (3 cases – treated non-operatively with brace), and elbow haemarthrosis (1 case). Discussion. TER with Discovery® Elbow System resulted in either no pain or mild pain in 87% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 22° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSB III (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 44° in pronation-supination arc in our series is also comparable to that of 31–67° reported for GSB III and higher than the Coonrad-Morrey prosthesis (21–28°). In terms of complications, an infection rate of 6.7% is consistent with those reported for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy was lower compared to GSB III TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%). While the survival of Discovery TER was 93%, the survival of GSB III (5–6 years) and Coonrad-Morrey (5 years) has been reported as 71–85% and 72–90%. The results indicate that Discovery® Elbow System is an effective device for total elbow arthroplasty in terms of functional improvement, pain relief and range of motion at short-term follow-up


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 273 - 273
1 Jul 2014
Alizadehkhaiyat O Vishwanathan K Frostick S
Full Access

Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of TER using this system. Methods. A total of 100 TERs (75 primary, 25 revisions) were performed between 2003 and 2010. The main primary underlying pathologies for TER were advanced rheumatoid arthritis (N=58), osteoarthritis (N=35), acute fractures (N=7). There were 60 female and 40 male patients with an average age of 62 years. The outcome assessment included pain, patient satisfaction, Liverpool Elbow Score (LES), range of movement, and imaging during a mean follow-up period of 48.5 months. Major complications are also reported. Results. For the whole patient group (primary + revision), the LES was significantly (p<0.001) improved from 3.79+/−1.71 to 6.36+/−1.85There were significant improvements in elbow flexion from 100°+/−24 to 118°+17, supination from 38°+/−26 to 50°+/−25 and pronation from 48°+/−22 to 61°+/−21. Mean improvement in flexion-extension and pronation-supination arc was 20° and 25°, respectively. 64% of cases were completely pain-free and at the final follow-up (compared to 7% preoperatively). Only 6% of patients scored “Not Satisfied” at the final follow-up. LES improvement was significantly higher in the primary TER compared to revision TER (p<0.05). Imaging reviewed for 60 cases showed loosening in 4% of patients. Other main complications included deep infection (N=2), ulnar neuropathy (N=3), pre-prosthetic fracture (N=2), and prosthetic failure (N=1). Discussion. TER using the Discovery Elbow System is an effective arthroplasty in terms of functional improvement, pain relief and range of motion in both primary and revision patients. TER resulted in no/mild pain in 78% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 20° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSBIII (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 25° in pronation-supination arc in our series is also comparable to that of 21–28° reported the Coonrad-Morrey and 27–33° for Discovery prostheses. An infection rate of 2% is lower than several other reports for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy (3%) was lower compared to GSBIII TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%)


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 163 - 163
1 Apr 2005
Little C Graham A Ionanides G Carr A
Full Access

A systematic review of the English language literature has suggested that the performance of linked and unlinked elbow replacement implants differ in terms of function, survival and mode of failure; however, in this review, only one comparative series using contemporary implants was identified. We have performed a cohort study of Kudo, Souter-Strathclyde and Coonrad-Morrey elbow replacements performed at a single centre by or under the direct supervision of a single Consultant shoulder and elbow surgeon to see if these findings were reflected in clinical practice. The first forty implantations in patients with Rheumatoid arthritis for each device have been reviewed with respect to surgical complications, elbow function and implant survival. The follow-up was shorter for the Coonrad-Morrey cohort. In terms of pain relief and range of motion, the performance of the implants was comparable. The mode of failure was different, with no dislocations/ instability seen with the linked Coonrad-Morrey implants. The loosening rate of the Coonrad-Morrey implants (both clinical and radiographic) was lower, albeit with a shorter follow-up period. The loosening rates seen in this series were higher than those previously reported in the English language literature. We conclude that the functional performance of the implants, at similar stages of the surgical learning curves, are similar in patients with Rheumatoid arthritis, but that use of a linked implant removes the risk of post-operative instability and may reduce the risk of the radiographic and clinical loosening


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 592 - 592
1 Dec 2013
Wright T Gunsallus K Lipman J Hotchkiss R Figgie MP
Full Access

Implant designs for hip and knee arthroplasty have undergone a continual improvement process, but development of implants for total elbow arthroplasty (TEA) have lagged behind despite the marked mechanical burden placed on these implants. TEA is not as durable with failure rates approaching thirty percent at five years. The Coonrad-Morrey (Zimmer, Warsaw, IN), a linked design, remains the standard-bearer, employing polyethylene bushings through which a metal axle passes. A common failure mode is bushing wear and deformation, causing decreased joint function as the bushing-axle constraint decreases and osteolysis secondary to release of large volumes of wear debris. Improving upon this poor performance requires determining which factors most influence failure, so that failure can be avoided through design improvements. The approach integrates clinical observations of failed TEAs with implant retrieval analysis, followed by measurements of loads across the elbow for use in stress analyses to assess the performance of previous designs, and, finally, new design approaches to improve performance. Examination of the clinical failures of more than seventy Coonrad-Morrey TEAs revealed patterns of decreased constraint and stem loosening. Implant retrieval analysis from more than thirty of these cases showed excessive bushing deformation and wear and burnishing of the fixation stems consistent with varus moments across the joint. To determine loads across the elbow, motion analysis data were collected from eight TEA patients performing various activities of daily living. The kinematic data were input into a computational model to calculate contact forces on the total elbow replacement. The motion that produced the maximum contact force was a feeding motion with the humerus in 90° of abduction. For this motion, the joint reaction forces and moments at the point of maximum contact were determined from a computational model. We applied these loads to numerical models of the articulating bushings and axle of the Coonrad-Morrey to examine polyethylene strains as measures of damage and wear. Strain patterns in response to the large varus moment applied to the elbow during feeding activities showed extensive plastic deformation in the locations at which deformation and wear damage were observed in our retrieved implants (Fig. 1). Finally, we examined a new semi-constrained design concept intended to meet two goals: transfer contact loads away from the center of the joint, thus allowing contact to provide a larger internal moment to resist the large external varus moment; and reduce polyethylene strains by utilizing curved contacting surfaces on both the axle and the bushings (Fig. 2). After a sensitivity analysis to determine optimal dimensional choices (e.g., bushing and axle radii), we compared the resulting polyethylene strains between the Coonrad-Morrey and new design at locations that experienced the largest strains (Fig. 3). Substantial decreases were achieved, suggesting far less deformation and wear, which should relate to marked improvements in performance. Currently, we are incorporating this new design concept, along with alterations in stem design achieved from examination of load transfer at the fixation interfaces based on the same loading conditions, to achieve an implant system intended to improve the performance of TEA


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 134 - 134
1 Mar 2006
Thomas S Simon J Nikhi T Lech S Rymaszewski
Full Access

Background: Flail or unstable elbow presents a difficult challenge for the elbow surgeon. This study reports the medium-term follow-up of 30 elbows in 25 patients, treated with two different designs of sloppy-hinged prosthesis: the Coonrad-Morrey and the snap-fit Souter-Strathclyde. Methods: All patients treated over a 12 year period by a single surgeon were identified and reviewed. This included a detailed history of indications, complications, and subjective assessment (including Mayo Elbow Performance Scores, subjective satisfaction score, and SF-12 mental and physical disability questionnaire), as well as examination and radiographic review of preoperative and most recent xrays. Results: 30 elbows in 25 surviving patients were assessed at an average postoperative period of 5.7 years. 17 Coonrad-Morrey and 13 snap-fit Souter-Strathclyde prostheses were implanted. 4 elbows (13.3%) have been revised. Average Mayo Elbow Performance score was 78.8 out of a top score of 100, with 15 classed as excellent, 5 good, 4 fair and 6 poor. Average subjective satisfaction with the operation was 4.5 out of a top score of 5. There was an average flexion arc of 104.7°, with 18 elbows ≥100°. 3 of the 17 Coonrad-Morrey elbows (17.6%) and 3 of the 13 snap-fit Souter-Strathclyde elbows (23.1%) demonstrated at least Grade 3 humeral radiolucency at the bone-cement interface. In the ulna, these figures were 6 out of 17 (35.3%) for Coonrad-Morrey elbows and 2 out of 13 (15.4%) for snap-fit Souter-Strathclyde elbows. Conclusions: Sloppy-hinged elbow replacement is a safe procedure with a high subjective satisfaction level. Its main indication is as a salvage operation in patients with a functionally useless elbow due to failed primary replacement or non-union of distal humeral fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 62 - 65
1 Jan 2007
Ito H Matsumoto T Yoshitomi H Kakinoki R Nakamura T

We compared the outcome of peri-operative humeral condylar fractures in patients undergoing a Coonrad-Morrey semiconstrained total elbow replacement with that of patients with rheumatoid arthritis undergoing the same procedure without fractures. In a consecutive series of 40 elbows in 33 patients, 13 elbows had a fracture in either condyle peri-operatively, and 27 elbows were intact. The fractured condyle was either fixed internally or excised. We found no statistical difference in the patients’ background, such as age, length of follow-up, immobilisation period, Larsen’s radiological grade, or Steinbrocker’s stage and functional class. There was also no statistical difference between the groups in relation to the Mayo Elbow Performance Score, muscle strength, range of movement, or radiolucency around the implants at a mean of 4.8 years (1.1 to 8.0) follow-up. We conclude that fractured condyles can be successfully treated with either internal fixation or excision, and cause no harmful effect


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 144 - 144
1 Jan 2016
Yonemoto Y Okamura K Takeuchi K Hosokawa T Kaneko T Matsushita M Okura C Kobayashi T Takagishi K
Full Access

Background. Previously, the Coonrad-Morrey elbow system has typically been performed using linked-type total elbow arthroplasty (TEA) implants. However, this implant have been reported to be associated with some problems, such as wearing down, loosening, the complexity of the necessary surgical techniques and inappropriate implant size for Asian people. The Discovery elbow system (Biomet Inc., Warsaw, US) has recently been developed and it has many advantages when compared to Coonrad-Morrey implant, but the treatment outcome for this system is unclear in patients with rheumatoid arthritis (RA). Objectives. The aim of this study was to clarify the outcome of TEA using the Discovery elbow system. Methods. Eleven RA patients (13 elbows) who underwent TEA using the Discovery elbow system were investigated in this study. Two patients (3 elbows) were males, and 9 patients (10 elbows) were females. Ten were right elbows, and 3 were left elbows. Two elbows has Larsen grade “disease, 7 had grade” disease and 4 elbows underwent revision surgery. The surgical approach used for all cases was Campbell's posterior approach. The Discovery elbow system was installed using cemented fixation. Two weeks after the operation, ROM exercise was started. The elbow ROM, Mayo elbow performance score (MEPS), and any complications observed at baseline, 6 months and 24 months after surgery were assessed. Results. The preoperative elbow ROM (mean±SD) was −33.4±4.4° in extension, 133.5±3.4° in flexion, 48.5±8.4° pronation and 67.7±5.7° in supination. The postoperative elbow ROM (mean±SD) was −18.5±6.2° in extension, 112.7±6.1° in flexion, 70.0±3.4° in pronation and 73.7±1.6° in supination. As a result, a significant improvement was observed in extension, flexion and pronation. The MEPS improved significantly at 6 months and 24 months after surgery. In addition, no implant loosening was found or revision surgery was required at 24 months after surgery. Conclusions. In this study, the elbow function was observed to significantly improve by TEA using the Discovery elbow system based on the short-time outcome. However, further study is still needed to clarify the long-term outcome of this implant in RA patients


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 343 - 348
1 Mar 2008
Prasad N Dent C

We analysed the outcome of the Coonrad-Morrey total elbow replacement used for fracture of the distal humerus in elderly patients with no evidence of inflammatory arthritis and compared the results for early versus delayed treatment. We studied a total of 32 patients with 15 in the early treatment group and 17 in the delayed treatment group. The mean follow-up was 56.1 months (18 to 88). The percentage of excellent to good results based on the Mayo elbow performance score was not significantly different, 84% in the early group and 79% in the delayed group. Subjective satisfaction was 92% in both the groups. One patient in the early group developed chronic regional pain syndrome and another type 4 aseptic loosening. Two elbows in the early group also showed type 1 radiological loosening. Two patients in the delayed group had an infection, two an ulnar nerve palsy, one developed heterotopic ossification and one type 4 aseptic loosening. Two elbows in this group also showed type 1 radiological loosening. The Kaplan-Meier survivorship analysis for the early and delayed treatment groups was 93% at 88 months and 76% at 84 months, respectively. No significant difference was found between the two groups


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 348 - 348
1 Jul 2008
Adeeb M Raza N Thomas M
Full Access

To date there has been only one published series of elbow arthroplasty in patients with Juvenile Idiopathic arthritis. These patients pose particular problems because of the size and variable shape of the humerus and ulna together with the soft tissue contractures and bony erosion which can sometimes be severe. We have reviewed the results of elbow arthroplasty using the unlinked Kudo 5 and the linked Coonrad-Morrey implants which in our practice have different indications dependent upon bone stock and stability. Methods 19 total elbow replacements in 13 patients with juvenile idiopathic arthritis were performed by 1 specialist elbow surgeon, the senior author. 13 of these are Kudo 5 and 6 are Coonrad-Morrey implants. The mean age at operation was 39 years. 6 of the elbow replacements had undergone previous surgery, 4 had an interposition arthroplasty and 2 a synovectomy and radial head excision. No patients were lost to follow up. All were evaluated at a mean follow up of 49 months [6–84 months] using the Mayo Clinic Performance Index. Postoperative radiographs were also reviewed for loosening using standard anteroposterior and lateral films. Results Preoperatively 7 had moderate pain and 12 had severe pain. Postoperatively the pain was rated as none by 13 and mild by 6. The average Mayo Elbow Score improved from 26 preoperatively to 81 postoperatively. The mean arc of flexion/extension improved from 85 to 108 degrees.12 elbow replacements had intra and post-operative complications and 2 elbows have been revised. Conclusions The medium-term results of Total Elbow Replacements in patients with Juvenile Chronic Arthritis are acceptable and comparable to the only other published series which also records a high complication rate


Bone & Joint Open
Vol. 4, Issue 1 | Pages 19 - 26
13 Jan 2023
Nishida K Nasu Y Hashizume K Okita S Nakahara R Saito T Ozaki T Inoue H

Aims

There are concerns regarding complications and longevity of total elbow arthroplasty (TEA) in young patients, and the few previous publications are mainly limited to reports on linked elbow devices. We investigated the clinical outcome of unlinked TEA for patients aged less than 50 years with rheumatoid arthritis (RA).

Methods

We retrospectively reviewed the records of 26 elbows of 21 patients with RA who were aged less than 50 years who underwent primary TEA with an unlinked elbow prosthesis. The mean patient age was 46 years (35 to 49), and the mean follow-up period was 13.6 years (6 to 27). Outcome measures included pain, range of motion, Mayo Elbow Performance Score (MEPS), radiological evaluation for radiolucent line and loosening, complications, and revision surgery with or without implant removal.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 216 - 216
1 May 2006
Adeeb MM Raza NN Thomas MM
Full Access

Background: To date there has been only one published series of elbow arthroplasty in patients with Juvenile Idiopathic arthritis. These patients pose particular problems because of the size and variable shape of the humerus and ulna together with the soft tissue contractures and bony erosion which can sometimes be severe. We have reviewed the results of elbow arthroplasty using the unlinked Kudo 5 and the linked Coonrad-Morrey implants which in our practice have different indications dependent upon bone stock and stability. Methods: 19 total elbow replacements in 13 patients with juvenile idiopathic arthritis were performed by 1 specialist elbow surgeon, the senior author. 13 of these are Kudo 5 and 6 are Coonrad-Morrey implants. The mean age at operation was 39 years. 6 of the elbow replacements had undergone previous surgery, 4 had an interposition arthroplasty and 2 a synovectomy and radial head excision. No patients were lost to follow up. All were evaluated at a mean follow up of 49 months [6–84 months] using the Mayo Clinic Performance Index. Postoperative radiographs were also reviewed for loosening using standard anteroposterior and lateral films. Results: Preoperatively 7 had moderate pain and 12 had severe pain. Postoperatively the pain was rated as none by 13 and mild by 6. The average Mayo Elbow Score improved from 26 preoperatively to 81 postoperatively. The mean arc of flexion/extension improved from 85 to 108 degrees.12 elbow replacements had intra and postoperative complications. 2 elbows have been revised, 1 for malalignment resulting in instability and 1 for aseptic loosening of the ulna component. 1 customised extra small implant has radiographic loosening of both components with minimal pain and a further aseptic loose implant awaits revision at 7 years. Conclusions: The medium-term results of Total Elbow Replacements in patients with Juvenile Chronic Arthritis are acceptable and comparable to the only other published series which also records a high complication rate similar to that reported by ourselves