The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 839 - 845
1 Jun 2007
Barsoum WK Patterson RW Higuera C Klika AK Krebs VE Molloy R

Dislocation remains a major concern after total hip replacement, and is often attributed to malposition of the components. The optimum position for placement of the components remains uncertain. We have attempted to identify a relatively safe zone in which movement of the hip will occur without impingement, even if one component is positioned incorrectly. A three-dimensional computer model was designed to simulate impingement and used to examine 125 combinations of positioning of the components in order to allow maximum movement without impingement. Increase in acetabular and/or femoral anteversion allowed greater internal rotation before impingement occurred, but decreases the amount of external rotation. A decrease in abduction of the acetabular components increased internal rotation while decreasing external rotation. Although some correction for malposition was allowable on the opposite side of the joint, extreme degrees could not be corrected because of bony impingement. We introduce the concept of combined component position, in which anteversion and abduction of the acetabular component, along with femoral anteversion, are all defined as critical elements for stability


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 125 - 125
1 Mar 2021
Eggermont F van der Wal G Westhoff P Laar A de Jong M Rozema T Kroon HM Ayu O Derikx L Dijkstra S Verdonschot N van der Linden YM Tanck E
Full Access

Patients with cancer and bone metastases can have an increased risk of fracturing their femur. Treatment is based on the impending fracture risk: patients with a high fracture risk are considered for prophylactic surgery, whereas low fracture risk patients are treated conservatively with radiotherapy to decrease pain. Current clinical guidelines suggest to determine fracture risk based on axial cortical involvement of the lesion on conventional radiographs, but that appears to be difficult. Therefore, we developed a patient-specific finite element (FE) computer model that has shown to be able to predict fracture risk in an experimental setting and in patients. The goal of this study was to determine whether patient-specific finite element (FE) computer models are better at predicting fracture risk for femoral bone metastases compared to clinical assessments based on axial cortical involvement on conventional radiographs, as described in current clinical guidelines. 45 patients (50 affected femurs) affected with predominantly lytic bone metastases who were treated with palliative radiotherapy for pain were included. CT scans were made and patients were followed for six months to determine whether or not they fractured their femur. Non-linear isotropic FE models were created with the patient-specific geometry and bone density obtained from the CT scans. Subsequently, an axial load was simulated on the models mimicking stance. Failure loads normalized for bodyweight (BW) were calculated for each femur. High and low fracture risks were determined using a failure load of 7.5 × BW as a threshold. Experienced assessors measured axial cortical involvement on conventional radiographs. Following clinical guidelines, patients with lesions larger than 30 mm were identified as having a high fracture risk. FE predictions were compared to clinical assessments by means of diagnostic accuracy values (sensitivity, specificity and positive (PPV) and negative predictive values (NPV)). Seven femurs (14%) fractured during follow-up. Median time to fracture was 8 weeks. FE models were better at predicting fracture risk in comparison to clinical assessments based on axial cortical involvement (sensitivity 100% vs. 86%, specificity 74% vs. 42%, PPV 39% vs. 19%, and NPV 100% vs. 95%, for the FE computer model vs. axial cortical involvement, respectively). We concluded that patient-specific FE computer models improve fracture risk predictions of femoral bone metastases in advanced cancer patients compared to clinical assessments based on axial cortical involvement, which is currently used in clinical guidelines. Therefore, we are initiating a pilot for clinical implementation of the FE model


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 77 - 77
1 Mar 2021
Ataei A Eggermont F Baars M Linden Y Rooy J Verdonschot N Tanck E
Full Access

Patients with advanced cancer can develop bone metastases in the femur which are often painful and increase the risk of pathological fracture. Accurate segmentation of bone metastases is, amongst others, important to improve patient-specific computer models which calculate fracture risk, and for radiotherapy planning to determine exact radiation fields. Deep learning algorithms have shown to be promising to improve segmentation accuracy for metastatic lesions, but require reliable segmentations as training input. The aim of this study was to investigate the inter- and intra-operator reliability of manual segmentation of femoral metastatic lesions and to define a set of lesions which can serve as a training dataset for deep learning algorithms. F. CT-scans of 60 advanced cancer patients with a femur affected with bone metastases (20 osteolytic, 20 osteoblastic and 20 mixed) were used in this study. Two operators were trained by an experienced radiologist and then segmented the metastatic lesions in all femurs twice with a four-week time interval. 3D and 2D Dice coefficients (DCs) were calculated to quantify the inter- and intra-operator reliability of the segmentations. We defined a DC>0.7 as good reliability, in line with a statistical image segmentation study. Mean first and second inter-operator 3D-DCs were 0.54 (±0.28) and 0.50 (±0.32), respectively. Mean intra-operator I and II 3D-DCs were 0.56 (±0.28) and 0.71 (±0.23), respectively. Larger lesions (>60 cm. 3. ) scored higher DCs in comparison with smaller lesions. This study reveals that manual segmentation of metastatic lesions is challenging and that the current manual segmentation approach resulted in dissatisfying outcomes, particularly for lesions with small volumes. However, segmentation of larger lesions resulted in a good inter- and intra-operator reliability. In addition, we were able to select 521 slices with good segmentation reliability that can be used to create a training dataset for deep learning algorithms. By using deep learning algorithms, we aim for more accurate automated lesion segmentations which might be used in computer modelling and radiotherapy planning


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 62 - 62
11 Apr 2023
Preutenborbeck M Wright P Loughran G Bishop N
Full Access

Orthopaedic impaction-instruments are used to drive implants into the bone of the patient. Pre-clinical experimental testing protocols and computer models of those are used to assess robustness and functional efficiency of such instruments. This generally involves impaction of the instrument mounted on a substrate that should represent the mechanics of the patient. In this study, the effects of the substrate on stressing of the impaction-instruments were investigated using dynamic finite element analysis. Model results were compared with experimental data from lab protocols, which have been derived to recreate the mechanics of cadaveric implantations, which represent clinical conditions. FEA models of selected experimental protocols were created in which a simplified instrument was impacted on substrates with varying material properties and boundary conditions. After impaction, the instrument settled into a modal vibration which then decayed over time. The resulting axial strain data from the computational model was compared to strain-gauge data collected from experimental measurements. Strain signal amplitude, frequency and decay were compared. The damping-ratio was derived from the decay of the strain signal. The computational model slightly over-predicted the initial experimental strain amplitudes in all cases, but the frequency of the cyclic strain signals matched. However, the model underestimated the experimentally measured rate of signal decay. Inclusion of implant seating and soft-tissue conditions had little effect on decay. Clinical failures of impaction-instruments may be related to multiple fatigue cycles for each impaction and should be modelled accurately to allow failure prediction. Any soft substrate results in an impedance mismatch at the instrument interface, which reflects the pressure wave and causes vibration with a frequency related to the speed-of-sound in the instrument, and its geometry. While this could be accurately modelled computationally, signal decay was underestimated. Further experimental quantification of energy losses will be important to understand vibration decay


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 104 - 104
14 Nov 2024
Amirouche F Kim S Mzeihem M Nyaaba W Mungalpara N Mejia A Gonzalez M
Full Access

Introduction. The human wrist is a highly complex joint, offering extensive motion across various planes. This study investigates scapholunate ligament (SLL) injuries’ impact on wrist stability and arthritis risks using cadaveric experiments and the finite element (FE) method. It aims to validate experimental findings with FE analysis results. Method. The study utilized eight wrist specimens on a custom rig to investigate Scapho-Lunate dissociation. Contact pressure and flexion were measured using sensors. A CT-based 3D geometry reconstruction approach was used to create the geometries needed for the FE analysis. The study used the Friedman test with pairwise comparisons to assess if differences between testing conditions were statistically significant. Result. The study found significant variations in scaphoid and lunate bone movement based on ligament condition. Full tears increased scapholunate distance in the distal-proximal direction and decreased in the medial-lateral direction. Lunate angles shifted from flexion to extension with fully torn ligaments. Conversely, the scaphoid shifted significantly from extension to flexion with full tears. A proximal movement was observed in the distal-proximal direction in all groups, with significant differences in the partial tear group. Lateral deviation of the scaphoid and lunate occurred with ligament damage, being more pronounced in the partial tear group. All groups exhibited statistically significant movement in the volar direction, with the full tear group showing the least movement. Also, radiocarpal joint and finger contact pressure and contact area were studied. Whereas the differences in contact area were not significant, scapholunate ligament tears resulted in significantly decreased finger contact pressures. FEA confirmed these findings, showing notable peak radiocarpal contact pressure differences between intact and fully torn ligaments. Conclusion. Our study found that SLL damage alters wrist stability, potentially leading to early arthritis. The FEA model confirmed these findings, indicating the potential for the clinical use of computer models from CT scans for treatment planning


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 20 - 20
1 Dec 2021
Yang I Gammell JD Murray DW Mellon SJ
Full Access

Abstract. Background. The Oxford Domed Lateral (ODL) Unicompartmental Knee Replacement (UKR) has some advantages over other lateral UKRs, but the mobile bearing dislocation rate is high (1–6%). Medial dislocations, with the bearing lodged on the tibial component wall, are most common. Anterior/posterior dislocations are rare. For a dislocation to occur distraction of the joint is required. We have developed and validated a dislocation analysis tool based on a computer model of the ODL with a robotics path-planning algorithm to determine the Vertical Distraction required for a Dislocation (VDD), which is inversely related to the risk of dislocation. Objectives. To modify the ODL design so the risk of medial dislocation decreases to that of an anterior/posterior dislocation. Methods. The components were modified using Solidworks. For each modification the dislocation analysis tool was used to determine the VDD for medial dislocation (with bearing 0–6mm from the tibial wall). This was compared with the original implant to identify the modifications that were most effective at reducing the dislocation risk. These modifications were combined into a final design, which was assessed. Results. Modifying the tibial component plateau, changing the femoral component width and making the bearing wider medially had little effect on VDD. Shifting the femoral sphere centre medially decreased VDD. Shifting the femoral sphere laterally, increasing tibial wall height and increasing bearing width laterally increased VDD. A modified implant with a femoral sphere centre 3mm lateral, wall 2.8mm higher, and bearing 2mm wider laterally, implanted so the bearing is ≤4mm from the tibial wall with a bearing thickness ≥4mm had a minimum VDD for medial dislocation of 5.75mm, which is larger than the minimum VDD for anterior/posterior dislocation of 5.5mm. Conclusions. A modified ODL design should decrease the dislocation rate to an acceptable level, however, further testing in cadavers is required. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 95 - 95
1 Jan 2017
Rivière C Shah H Auvinet E Iranpour F Harris S Cobb J Howell S Aframian A
Full Access

Trochlear geometry of modern femoral implants is designed for mechanical alignment (MA) technique for TKA. The biomechanical goal is to create a proximalised and more valgus trochlea to better capture the patella and optimize tracking. In contrast, Kinematic alignment (KA) technique for TKA respects the integrity of the soft tissue envelope and therefore aims to restore native articular surfaces, either femoro-tibial or femoro-patellar. Consequently, it is possible that current implant designs are not suitable for restoring patient specific trochlea anatomy when they are implanted using the kinematic technique, this could cause patellar complications, either anterior knee pain, instability or accelerated wear or loosening. The aim of our study is therefore to explore the extent to which native trochlear geometry is restored when the Persona. ®. implant (Zimmer, Warsaw, USA) is kinematically aligned. A retrospective study of a cohort of 15 patients with KA-TKA was performed with the Persona. ®. prosthesis (Zimmer, Warsaw, USA). Preoperative knee MRIs and postoperative knee CTs were segmented to create 3D femoral models. MRI and CT segmentation used Materialise Mimics and Acrobot Modeller software, respectively. Persona. ®. implants were laser scanned to generate 3D implant models. Those implant models have been overlaid on the 3D femoral implant model (generated via segmentation of postoperative CTs) to replicate, in silico, the alignment of the implant on the post-operative bone and to reproduce in the computer models the features of the implant lost due to CT metal artefacts. 3D models generated from post-operative CT and pre-operative MRI were registered to the same coordinate geometry. A custom written planner was used to align the implant, as located on the CT, onto the pre-operative MRI based model. In house software enabled a comparison of trochlea parameters between the native trochlea and the performed prosthetic trochlea. Parameters assessed included 3D trochlear axis and anteroposterior offset from medial facet, central groove, and lateral facet. Sulcus angle at 30% and 40% flexion was also measured. Inter and intra observer measurement variabilities have been assessed. Varus-valgus rotation between the native and prosthetic trochleae was significantly different (p<0.001), with the prosthetic trochlear groove being on average 7.9 degrees more valgus. Medial and lateral facets and trochlear groove were significantly understuffed (3 to 6mm) postoperatively in the proximal two thirds of the trochlear, with greatest understuffing for the lateral facet (p<0.05). The mean medio-lateral translation and internal-external rotation of the groove and the sulcus angle showed no statistical differences, pre and postoperatively. Kinematic alignment of Persona. ®. implants poorly restores native trochlear geometry. Its clinical impact remains to be defined


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 140 - 146
1 Jan 1997
Robinson RP Simonian PT Gradisar IM Ching RP

A three-dimensional computer model of a total hip replacement was used to examine the relationship between the position of the components, the range of motion and the prosthetic joint contact area. Horizontal acetabular positions with small amounts of acetabular and femoral anteversion provide the largest contact areas, but result in limited joint movement. These data will allow surgeons to select implant positions that will provide the largest possible joint contact area for a given joint range of motion although these are conflicting goals. In some component positions a truncated spherical prosthetic head resulted in smaller contact areas than a completely spherical head


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 74 - 74
1 Aug 2012
Mak J Moazen M Jones A Jin Z Tsirdis E Wilcox R
Full Access

Periprosthetic femoral fractures can occur as a complication of total hip arthroplasty and are often challenging to treat as the mechanical scenario is influenced by the presence of the metal prosthesis within the bone. This research focuses on finding the optimum fixation for transverse, Vancouver type B1 periprosthetic fractures, stabilised using locking plates and secured using screws. The aim of this study was to experimentally validate a computer model of a human femur, develop that model to represent a periprosthetic femoral fracture fixation and show how the model could be used to indicate differences between plating techniques. In the first development stage, both a laboratory model and a finite element model were developed to evaluate the mechanical behaviour of an intact composite femur under axial loading. Axial strains were recorded along the medial length of the femur in both cases and compared to provide validation for the computational model predications. The computational intact femur model was then modified to include a cemented total hip replacement, and further adapted to include a periprosthetic fracture stabilised using a locking plate, with unicortical screws above, and bicortical screws below the transverse fracture. For the intact femur case, the experimental and computational strain patterns correlated well with an average difference of 16%. Following the inclusion of the stem, there was a reduction in the strain in the region of the prosthesis reducing by an average of 45%. There was also a large increase in bulk stiffness with the introduction of the prosthesis. When the fracture and plate fixation were included, there was little difference in the proximal strain where the stem dominated, and the strains in the distal region were found to be highly sensitive to the distribution of the screws. The results of this study indicate that screw configuration is an important factor in periprosthetic fracture fixation. A laboratory model of the periprosthetic facture case is now under development to further validate the computational models and the two approaches will then be used to determine optimum fixation methods for a range of clinical scenarios


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 51 - 51
1 May 2017
Frame M
Full Access

Aim. The aim of this study is to outline the steps and techniques required to create a patient specific 3D printed guide for the accurate placement of the origin of the femoral tunnel for single bundle ACL reconstruction. Introduction. Placements of the femoral tunnels for ACL reconstruction have changed over the years. Most recently there has been a trend towards placing the tunnels in a more anatomic position. There has been subsequent debate as to where this anatomic position should be. The problem with any attempt at consensus over the placement of an anatomic landmark is that each patient has some variation in their positioning and therefore a fixed point for all has compromise for all as it is an average. Our aim was to attempt to make a cost effective and quick custom guide that could allow placement of the center of the patients’ newly created femoral tunnel in the mid position of their contralateral native ACL femoral footprint. Materials & Methods. We took a standard protocol MRI scan of a patient's knee without ACL injury transferred the DICOM files to a personal computer running OsiriX (Pixmeo, Geneva, Switzerland.) and analysed it for a series of specific anatomical landmarks. OsiriX is an image processing software dedicated to DICOM images. We marked the most posterior edge of the articular cartilage on the lateral wall of the notch (1), the most anterior edge of the articular cartilage of the lateral wall of the notch (2), the most inferior edge of the articular cartilage of the lateral wall of the notch (3) and the center of the femoral footprint of the native ACL. Distances were then calculated to determine the position relative to the three articular cartilage points of the center of the ACL footprint. These measurements and points were then utilised to create a 3D computer aided design (CAD) model of a custom guide. This was done using the 3D CAD program 123Design (Autodesk Ltd., Farnbourgh, Hampshire). This 3D model was then exported as an STL file suitable for 3D printing. The STL file was then uploaded to an online 3D printing service and the physical guide was created in transparent acrylic based photopolymer, PA220 plastic and 316L stainless steel. The models created were then measured using vernier calipers to confirm the accuracy of the final guides. Results. The MRI data showed point 1 (AP), point 2 (distal-ACL), point 3 (Ant-ACL) and point 4 (Post-ACL) at a distance of 59.83, 15, 45.8 and 13.9 respectively. For the 3D CAD model, points 1, 2, 3 and 4 were at a distance of 59.83, 15, 45.8 and 13.9 respectively. For the PA220 plastic model, points 1, 2, 3 and 4 were at a distance of 59.86, 14.48, 45.85 and 13.79 respectively. For the 316L stainless steel model, points 1, 2, 3 and 4 were at a distance of 59.79, 14.67, 45.64 and 13.48 respectively. Lastly, for the photopolymer model, points 1, 2, 3 and 4 were at a distance of 59.86, 14.2, 45.4 and 13.69 respectively. The p-value comparing MRI/CAD vs. PA220 was p=0.3753; for the comparison between MRI/CAD vs. 316L, p=0.0683; lastly for the comparison between MRI/CAD Vs. Photopolymer, p=0.3450. The models produced were accurate with no statistical difference in size and positioning of the center of the ACL footprint from the original computer model and to the position of the ACL from the MRI scans. The costs for the models 3D printed were £3.50 for the PA220 plastic, £15 for the transparent photopolymer and £25 for the 316L stainless steel. The time taken from MRI to delivery for the physical models was 7 days. Discussion. Articles regarding the creation of 3D printed custom ACL guides from the patients contralateral knee do not feature in current literature. There has been much research on custom guides for other orthopaedic procedures such as in total knee arthroplasty for the accurate placement of implants. There has also been research published on the creation of custom cutting jigs from CT for complex corrective osteotomy surgery. This study serves as the first step and a proof of concept for the accurate creation of patient specific 3D printed guides for the anatomical placement of the femoral tunnel for ACL reconstruction. The guides were easy to create and produce taking only a week and with a cost of between £3.50 and £25. The design of the guides was to allow the tip of a standard Chondro Pick (Arthrex inc., Naples, Florida.) (3mm) used to mark the starting point of the femoral tunnel to enter through the guide. The next step for this research is to create guides from cadaveric matched knees and utilise the guides to carry out the creation of the femoral tunnels and to analyse of the placement of the tunnel in relation to the contralateral knee


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 75 - 75
1 Jul 2014
Farinella G Viceconti M Schileo E Falcinelli C Yang L Eastell R
Full Access

Summary. A retrospective study on 98 patients shows that FE-based bone strength from CT data (using validated FE models) is a suitable candidate to discriminate fractured versus controls within a clinical cohort. Introduction. Subject-specific Finite element models (FEM) from CT data are a promising tool to non-invasively assess the bone strength and the risk of fracture of bones in vivo in individual patients. The current clinical indicators, based on the epidemiological models like the FRAX tool, give limitation estimation of the risk of femoral neck fracture and they do not account for the mechanical determinants of the fracture. Aim of the present study is to prove the better predictive accuracy of individualised computer models based a CT-FEM protocol, with the accuracy of a widely used standard of care, the FRAX risk indicator. Patients and Methods. This retrospective cohort is individually-matched case control study composed by 98 Caucasian women who were at least 5 years post menopause. The case group consisted of 49 patients who had sustained a hip fracture (36 intra-capsular and 13 extra-capsular fractures) within the previous 90 days due to low-energy trauma. The CT datasets were segmented (using the ITK-Snap software) in order to extract the periosteal bone surface. Unstructured meshes (10-node tetrahedral elements) were generated using ANSYS mesh morphing software. Each CT dataset was calibrated using the European Spine Phantom. The inhomogeneous material properties were mapped from CT datasets into the FEM with the BoneMat_V3 software. Bone strength was evaluated in quasi-axial loading conditions, for a set of 12 different configurations sampling the cone of recorded in vivo hip joint reactions, and was defined as the minimum load inducing on the femoral neck surface an elastic principal strain value greater than a limit value. Results. There were no statistically significant difference between the fracture and the control groups for age, height and weight (p<0.05). All indices of areal bone mineral density (aBMD) and the volumetric mineral density (vBMD) between fractured and controls showed on average a lower value for fractured respect of the controls, with similar mean difference (14% for aBMD and 13% for the vBMD). FEM-predicted strength differed between fractured and non-fractured on average for 20%. To evaluate its ability to identify patients at risk of hip fracture, FEM-based strength was compared to the FRAX predictor by computing for each predictor the Receiver Operating Characteristic (ROC) curve, and the Area Under the Curve (AUC). The individualised risk predictor based on FEM bone strength was found to perform significantly better (AUC=0.76) than FRAX (AUC=0.66). When the FEM-based strength indicator was combined with available clinical information in a logistic regression, the resulting predictor achieved in this retrospective study an excellent accuracy (AUC=0.82). Discussion. This study confirms that individualised, CT- FEM, when generated using to the state-of-the-art protocols, can provide a predictor of the risk of hip fracture more accurate than those based on clinical data alone. In the integrated workflow developed in the VPHOP Project (FP7-ICT-223865) CT-based risk prediction is requested only for those patients for whom the clinical decision is uncertain


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 59 - 59
1 May 2012
Simpson DJ Kendrick B Thomas G Gill H O'Connor J Murray DW
Full Access

Introduction. The results of the original mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing because of high dislocation rates (11%). This original implant used a flat bearing articulation on the tibial tray. To address the issue of dislocation a new implant (domed tibia with biconcave bearing to increase entrapment) was introduced with a modified surgical technique. The aim of this study was to compare the risk of dislocation between a domed and flat lateral UKR. Methods. Separate geometric computer models of an Oxford mobile bearing lateral UKR were generated for the two types of articulation between the tibial component and the meniscal bearing: Flat-on-flat (flat) and Concave-on-convex (domed). Each type of mobile bearing was used to investigate three distinct dislocation modes observed clinically: lateral to medial dislocation, with the bearing resting on the tray wall (L-M-Wall); medial to lateral dislocation, out of the joint space (M-L); anterior to posterior dislocation, out of the joint space (A-P). A size C tray and a medium femoral component and bearing were used in all models. The femoral component, tibial tray and bearing were first aligned in a neutral position. For each dislocation the tibial tray was restrained in all degrees of freedom. The femoral component was restrained from moving in the anterior-posterior directions and in the medial-lateral directions. The femoral component was also restrained from rotating about the anterior-posterior, medial-lateral and superior-inferior directions. This meant that the femoral component was only able to move in the superior-inferior direction. Different bearing sizes were inserted into the model and the effect that moving the femoral component medially and laterally had on the amount of distraction required to cause bearing dislocation was investigated. Results. The average femur distraction to allow bearing dislocation in the A-P, M-L and L-M-wall directions was 1.62 mm (27%), 0.51 mm (26%) and 1.2 mm (24%) greater respectively for the domed bearing. There was a 3% increase in femoral distraction required to cause L-M-Wall dislocation, per increment of bearing thickness for both the domed and lateral bearings. There was on average a 7% increase in femoral distraction required to cause L-M-Wall dislocation per mm increment of medial femoral component movement. Discussion. Dislocation over the tray wall is a particular clinical problem and using a domed bearing can lead to an increased required femoral distraction of between 25% and 37%. This may be significant during everyday activities and demonstrates that the new domed design should reduce the incidence of bearing dislocation by increasing the amount of entrapment. Increasing the thickness of the bearing has a small effect on the distraction required to allow bearing dislocation. Lateral placement of the femoral component markedly reduced the femoral distraction required for bearing dislocation over the tray wall. Medial placement of the femoral component is advisable so long as impingement with the tray wall is avoided


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 75 - 75
1 May 2017
Koris J Blunn G Coathup M
Full Access

Background. Children suffering from primary bone cancer necessitating resection of growth plates, may suffer progressive leg length discrepancy, which can be attenuated with extendable prostheses. A serious complication is catastrophic implant failure. Over time, bone will remodel, altering the stress pattern in the implant. By using finite element analysis we can model different bone remodeling conditions to ascertain the effect that this will have on stress distribution and magnitude. A finite element analysis was performed. Simplified computer generated models were designed of a cemented femoral Stanmore growing massive endoprosthesis. Three scenarios were designed, modelled on post-operative radiographs. Scenario 1 had a gap between the end of the femur and the implant collar, scenario 2 had no gap, but with no bone attachment into the collar, and scenario 3 had growth of the bone over the length of the collar with attachment. Physiological loading conditions were applied. The resultant stress in the implant for each scenario was measured, and compared to the strength of the material. Peak stresses were recorded at the stem-collar junction. The maximum stress recorded in the implant in scenario 1 was 3104.2Mpa, compared to 1054.4Mpa in scenario 2, and 321.2Mpa in scenario 3. Conclusions. Both accurate reduction and bone growth with attachment to the stem of a massive endoprosthesis will greatly reduce the resultant stress in the implant under loading conditions. The load is redistributed throughout the length of the bone. This may help to prevent catastrophic failure in the implant under loading conditions. Further investigations of patient findings are needed to ensure the model findings are verified. Level of Evidence. IIb (Theoretical)


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 711 - 719
1 Jul 1998
Sugano N Noble PC Kamaric E Salama JK Ochi T Tullos HS

We studied the morphometry of 35 femora from 31 female patients with developmental dysplasia of the hip (DDH) and another 15 from 15 age- and sex-matched control patients using CT and three-dimensional computer reconstruction models. According to the classification of Crowe et al 15 of the dysplastic hips were graded as class I (less than 50% subluxation), ten as class II/III (50% to 100% subluxation) and ten as class IV (more than 100% subluxation). The femora with DDH had 10 to 14° more anteversion than the control group independent of the degree of subluxation of the hip. In even the most mildly dysplastic joints, the femur had a smaller and more anteverted canal than the normal control. With increased subluxation, additional abnormalities were observed in the size and position of the femoral head. Femora from dislocated joints had a short, anteverted neck associated with a smaller, narrower, and straighter canal than femora of classes I and II/III or the normal control group. We suggest that when total hip replacement is performed in the patient with DDH, the femoral prosthesis should be chosen on the basis of the severity of the subluxation and the degree of anteversion of each individual femur


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 2 - 2
1 Jul 2014
Gao B Angibaud L
Full Access

Summary Statement. The constraint behavior of total knee arthroplasty (TKA) prosthesis usually has to be physically tested. This study presents a computer simulation model using finite element analysis (FEA) and demonstrates its effectiveness in predicting the femorotibial constraint behavior of TKA implants. Introduction. TKA prostheses are semi-constrained artificial joints. A well-functioning TKA prosthesis should be designed with a good balance between stability and mobility, meaning the femorotibial constraint of the artificial joint cannot be excessive or too lax. To assess the constraint behavior of a TKA prosthesis, physical testing is usually required, and an industrial test standard has been developed for this purpose. Benefiting from technological advancement, computer simulation has become increasingly useful in many industries, including medical device research and development. FEA has been extensively used in stress analysis and structural evaluation of various orthopaedic implants. This study presented an FEA-based simulation to evaluate the femorotibial constraint behavior of TKA prosthesis, and demonstrated the effectiveness of the method by validating it through physical testing. Methods. A Cruciate Retaining (CR) TKA prosthesis design (Optetrak Logic CR, size 3, Exactech, FL, USA) was used in this study. The prosthesis system consists of a femoral component, a tibial insert, and a tibial baseplate. CAD models of the implants assembled at 0° of flexion were used for the simulation. Finite element models were generated using 10-node tetrahedral elements, with all materials considered linear elastic. Boundary conditions were set up according to the ASTM F1223 standard. The tibial baseplate was fixed distally. A constant compressive force (710 N) was applied on the femoral component. Nonlinear Surface-Surface-Contact was defined at the femorotibial articulating surfaces as well as between the tibial insert and tibial baseplate. A coefficient of friction of 0.2 determined from the physical test was input into the simulation. The femoral component was driven under a displacement-controlled scheme to slide along the anterior-posterior (AP) direction on the tibial insert. At each time step, constraint force occurring at the articulating surface was derived from the reaction force at the distal fixation of the tibial baseplate. The force-displacement curve was plotted by combining the results of all time steps to characterize the constraint behavior of the prosthesis. A nonlinear FEA solver (NX Nastran SOL601, Siemens, TX, USA) was used to solve the simulation. In addition, five samples of the prostheses were physically tested per ASTM F1223. Simulation results were compared to the physical testing. Results. The simulation successfully captured the movement of contact location and pressure along the movement of the femoral component. The force-displacement curve predicted by the simulation exhibited a very close hysteresis loop profile as the results of physical testing. Using the curve slope from 0 to 5 mm to characterise the constraint in the most relevant displacement range, the simulation predicted 45.7 N/mm anteriorly and 36.4 N/mm posteriorly, which are less than 10% different from the physical testing results (46.4 N/mm anteriorly and 39.6 N/mm posteriorly). Discussion/Conclusion. This study demonstrated that the simulation was able to closely predict the femorotibial constraint behavior of the TKA prosthesis under ASTM F1223 testing. The simulation results resembled the physical test results not only in the general profile of the curve but also in the magnitude of slope values. The increased difference at the far anterior region could be related to the fact that no material nonlinearity was considered in the current simulation, a factor that could be improved in future studies. A validated simulation method could be very useful in TKA prosthesis design. Since no physical prototypes are required, design evaluation and optimization can be achieved in a much easier and faster manner


Bone & Joint Research
Vol. 6, Issue 10 | Pages 602 - 609
1 Oct 2017
Jin A Cobb J Hansen U Bhattacharya R Reinhard C Vo N Atwood R Li J Karunaratne A Wiles C Abel R

Objectives

Bisphosphonates (BP) are the first-line treatment for preventing fragility fractures. However, concern regarding their efficacy is growing because bisphosphonate is associated with over-suppression of remodelling and accumulation of microcracks. While dual-energy X-ray absorptiometry (DXA) scanning may show a gain in bone density, the impact of this class of drug on mechanical properties remains unclear. We therefore sought to quantify the mechanical strength of bone treated with BP (oral alendronate), and correlate data with the microarchitecture and density of microcracks in comparison with untreated controls.

Methods

Trabecular bone from hip fracture patients treated with BP (n = 10) was compared with naïve fractured (n = 14) and non-fractured controls (n = 6). Trabecular cores were synchrotron scanned and micro-CT scanned for microstructural analysis, including quantification of bone volume fraction, microarchitecture and microcracks. The specimens were then mechanically tested in compression.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 35 - 35
1 Aug 2012
Ranawat A Buly RL


Bone & Joint Research
Vol. 2, Issue 12 | Pages 276 - 284
1 Dec 2013
Karlakki S Brem M Giannini S Khanduja V Stannard J Martin R

Objectives

The period of post-operative treatment before surgical wounds are completely closed remains a key window, during which one can apply new technologies that can minimise complications. One such technology is the use of negative pressure wound therapy to manage and accelerate healing of the closed incisional wound (incisional NPWT).

Methods

We undertook a literature review of this emerging indication to identify evidence within orthopaedic surgery and other surgical disciplines. Literature that supports our current understanding of the mechanisms of action was also reviewed in detail.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 676 - 682
1 May 2009
Østbyhaug PO Klaksvik J Romundstad P Aamodt A

Hydroxyapatite-coated standard anatomical and customised femoral stems are designed to transmit load to the metaphyseal part of the proximal femur in order to avoid stress shielding and to reduce resorption of bone. In a randomised in vitro study, we compared the changes in the pattern of cortical strain after the insertion of hydroxyapatite-coated standard anatomical and customised stems in 12 pairs of human cadaver femora. A hip simulator reproduced the physiological loads on the proximal femur in single-leg stance and stair-climbing. The cortical strains were measured before and after the insertion of the stems.

Significantly higher strain shielding was seen in Gruen zones 7, 6, 5, 3 and 2 after the insertion of the anatomical stem compared with the customised stem. For the anatomical stem, the hoop strains on the femur also indicated that the load was transferred to the cortical bone at the lower metaphyseal or upper diaphyseal part of the proximal femur.

The customised stem induced a strain pattern more similar to that of the intact femur than the standard, anatomical stem.