Results 1 - 20 of 149
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 1 - 1
11 Apr 2023
Mischler D Knecht M Varga P
Full Access

Surgical education of fracture fixation biomechanics relies mainly on simplified illustrations to distill the essence of the underlying principles. These mostly consist of textbook drawings or hands-on exercises during courses, both with unique advantages such as broad availability and haptics, respectively. Computer simulations are suited to bridge these two approaches; however, the validity of such simulations must be guaranteed to teach the correct aspects. Therefore, the aim of this study was to validate finite element (FE) simulations of bone-plate constructs to be used in surgical education in terms of fracture gap movement and implant surface strain. The validation procedure was conducted in a systematic and hierarchical manner with increasing complexity. First, the material properties of the isolated implant components were determined via four-point bending of the plate and three-point bending of the screw. Second, stiffness of the screw-plate interface was evaluated by means of cantilever bending to determine the properties of the locking mechanism. Third, implant surface strain and fracture gap motion were measured by testing various configurations of entire fixation constructs on artificial bone (Canevasit) in axial compression. The determined properties of the materials and interfaces assessed in these experiments were then implemented into FE models of entire fixation constructs with different fracture width and screw configurations. The FE-predicted implant surface strains and fracture gap motions were compared with the experimental results. The simulated results of the different construct configurations correlated strongly with the experimentally measured fracture gap motions (R. 2. >0.99) and plate surface strains (R. 2. >0.95). In a systematic approach, FE model validation was achieved successfully in terms of fracture gap motion and implant deformation, confirming trustworthiness for surgical education. These validated models are used in a novel online education tool OSapp (. https://osapp.ch/. ) to illustrate and explain the biomechanical principles of fracture fixations in an interactive manner


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 125 - 125
1 Mar 2021
Eggermont F van der Wal G Westhoff P Laar A de Jong M Rozema T Kroon HM Ayu O Derikx L Dijkstra S Verdonschot N van der Linden YM Tanck E
Full Access

Patients with cancer and bone metastases can have an increased risk of fracturing their femur. Treatment is based on the impending fracture risk: patients with a high fracture risk are considered for prophylactic surgery, whereas low fracture risk patients are treated conservatively with radiotherapy to decrease pain. Current clinical guidelines suggest to determine fracture risk based on axial cortical involvement of the lesion on conventional radiographs, but that appears to be difficult. Therefore, we developed a patient-specific finite element (FE) computer model that has shown to be able to predict fracture risk in an experimental setting and in patients. The goal of this study was to determine whether patient-specific finite element (FE) computer models are better at predicting fracture risk for femoral bone metastases compared to clinical assessments based on axial cortical involvement on conventional radiographs, as described in current clinical guidelines. 45 patients (50 affected femurs) affected with predominantly lytic bone metastases who were treated with palliative radiotherapy for pain were included. CT scans were made and patients were followed for six months to determine whether or not they fractured their femur. Non-linear isotropic FE models were created with the patient-specific geometry and bone density obtained from the CT scans. Subsequently, an axial load was simulated on the models mimicking stance. Failure loads normalized for bodyweight (BW) were calculated for each femur. High and low fracture risks were determined using a failure load of 7.5 × BW as a threshold. Experienced assessors measured axial cortical involvement on conventional radiographs. Following clinical guidelines, patients with lesions larger than 30 mm were identified as having a high fracture risk. FE predictions were compared to clinical assessments by means of diagnostic accuracy values (sensitivity, specificity and positive (PPV) and negative predictive values (NPV)). Seven femurs (14%) fractured during follow-up. Median time to fracture was 8 weeks. FE models were better at predicting fracture risk in comparison to clinical assessments based on axial cortical involvement (sensitivity 100% vs. 86%, specificity 74% vs. 42%, PPV 39% vs. 19%, and NPV 100% vs. 95%, for the FE computer model vs. axial cortical involvement, respectively). We concluded that patient-specific FE computer models improve fracture risk predictions of femoral bone metastases in advanced cancer patients compared to clinical assessments based on axial cortical involvement, which is currently used in clinical guidelines. Therefore, we are initiating a pilot for clinical implementation of the FE model


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 105 - 105
14 Nov 2024
Spoo S Garcia F Braun B Cabri J Grimm B
Full Access

Introduction. The objective assessment of shoulder function is important for personalized diagnosis, therapies and evidence-based practice but has been limited by specialized equipment and dedicated movement laboratories. Advances in AI-driven computer vision (CV) using consumer RGB cameras (red-blue-green) and open-source CV models offer the potential for routine clinical use. However, key concepts, evidence, and research gaps have not yet been synthesized to drive clinical translation. This scoping review aims to map related literature. Method. Following the JBI Manual for Evidence Synthesis, a scoping review was conducted on PubMed and Scholar using search terms including “shoulder,” “pose estimation,” “camera”, and others. From 146 initial results, 27 papers focusing on clinical applicability and using consumer cameras were included. Analysis employed a Grounded Theory approach guided iterative refinement. Result. Studies primarily used Microsoft Kinect (infrared-based depth sensing, RGB camera; discontinued) or monocular consumer cameras with open-source CV-models, sometimes supplemented by LiDAR (laser-based depth sensing), wearables or markers. Technical validation studies against gold standards were scarce and too inconsistent for comparison. Larger range of motion (RoM) movements were accurately recorded, but smaller movements, rotations and scapula tracking remained challenging. For instance, one larger validation study comparing shoulder angles during arm raises to a marker-based gold-standard reported Pearson's R = 0.98 and a standard error of 2.4deg. OpenPose and Mediapipe were the most used CV-models. Recent efforts try to improve model performance by training with shoulder specific movements. Conclusion. Low-cost, routine clinical movement analysis to assess shoulder function using consumer cameras and CV seems feasible. It can provide acceptable accuracy for certain movement tasks and larger RoM. Capturing small, hidden or the entirety of shoulder movement requires improvements such as via training models with shoulder specific data or using dual cameras. Technical validation studies require methodological standardization, and clinical validation against established constructs is needed for translation into practice


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 557 - 560
1 Apr 2007
Davis ET Gallie P Macgroarty K Waddell JP Schemitsch E

A cadaver study using six pairs of lower limbs was conducted to investigate the accuracy of computer navigation and standard instrumentation for the placement of the Birmingham Hip Resurfacing femoral component. The aim was to place all the femoral components with a stem-shaft angle of 135°. The mean stem-shaft angle obtained in the standard instrumentation group was 127.7° (120° to 132°), compared with 133.3° (131° to 139°) in the computer navigation group (p = 0.03). The scatter obtained with computer-assisted navigation was approximately half that found using the conventional jig. Computer navigation was more accurate and more consistent in its placement of the femoral component than standard instrumentation. We suggest that image-free computer-assisted navigation may have an application in aligning the femoral component during hip resurfacing


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 26 - 26
1 Aug 2013
Young PS Bell SW Mahendra A
Full Access

The surgical management of musculoskeletal tumours is a challenging problem, particularly in pelvic and diaphyseal tumour resection where accurate determination of bony transection points is extremely important to optimise oncologic, functional and reconstructive options. The use of computer assisted navigation in these cases could improve surgical precision and achieve pre-planned oncological margins with improved accuracy. We resected musculoskeletal tumours in ten patients using commercially available computer navigation software (Orthomap 3D, Stryker UK Ltd). Of the five pelvic tumours, two underwent biological reconstruction with extra corporeal irradiation, two endoprosthetic replacement (EPR) and one did not require bony reconstruction. Three tibial diaphyseal tumours had biological reconstruction. One patient with proximal femoral sarcoma underwent extra-articular resection and EPR. One soft tissue sarcoma of the adductor compartment involving the femur was resected with EPR. Histological examination of the resected specimens revealed tumour free margins in all cases. Post-operative radiographs and CT show resection and reconstruction as planned in all cases. Several learning points were identified related to juvenile bony anatomy and intra-operative registration. The use of computer navigation in musculoskeletal oncology allows integration of local anatomy and tumour extent to identify resection margins accurately. Furthermore, it can aid in reconstruction following tumour resection. Our experience thus far has been encouraging. Further clinical trials are required to evaluate its long-term impact on functional & oncological outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 839 - 845
1 Jun 2007
Barsoum WK Patterson RW Higuera C Klika AK Krebs VE Molloy R

Dislocation remains a major concern after total hip replacement, and is often attributed to malposition of the components. The optimum position for placement of the components remains uncertain. We have attempted to identify a relatively safe zone in which movement of the hip will occur without impingement, even if one component is positioned incorrectly. A three-dimensional computer model was designed to simulate impingement and used to examine 125 combinations of positioning of the components in order to allow maximum movement without impingement. Increase in acetabular and/or femoral anteversion allowed greater internal rotation before impingement occurred, but decreases the amount of external rotation. A decrease in abduction of the acetabular components increased internal rotation while decreasing external rotation. Although some correction for malposition was allowable on the opposite side of the joint, extreme degrees could not be corrected because of bony impingement. We introduce the concept of combined component position, in which anteversion and abduction of the acetabular component, along with femoral anteversion, are all defined as critical elements for stability


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 2 - 2
1 Jul 2014
Gao B Angibaud L
Full Access

Summary Statement. The constraint behavior of total knee arthroplasty (TKA) prosthesis usually has to be physically tested. This study presents a computer simulation model using finite element analysis (FEA) and demonstrates its effectiveness in predicting the femorotibial constraint behavior of TKA implants. Introduction. TKA prostheses are semi-constrained artificial joints. A well-functioning TKA prosthesis should be designed with a good balance between stability and mobility, meaning the femorotibial constraint of the artificial joint cannot be excessive or too lax. To assess the constraint behavior of a TKA prosthesis, physical testing is usually required, and an industrial test standard has been developed for this purpose. Benefiting from technological advancement, computer simulation has become increasingly useful in many industries, including medical device research and development. FEA has been extensively used in stress analysis and structural evaluation of various orthopaedic implants. This study presented an FEA-based simulation to evaluate the femorotibial constraint behavior of TKA prosthesis, and demonstrated the effectiveness of the method by validating it through physical testing. Methods. A Cruciate Retaining (CR) TKA prosthesis design (Optetrak Logic CR, size 3, Exactech, FL, USA) was used in this study. The prosthesis system consists of a femoral component, a tibial insert, and a tibial baseplate. CAD models of the implants assembled at 0° of flexion were used for the simulation. Finite element models were generated using 10-node tetrahedral elements, with all materials considered linear elastic. Boundary conditions were set up according to the ASTM F1223 standard. The tibial baseplate was fixed distally. A constant compressive force (710 N) was applied on the femoral component. Nonlinear Surface-Surface-Contact was defined at the femorotibial articulating surfaces as well as between the tibial insert and tibial baseplate. A coefficient of friction of 0.2 determined from the physical test was input into the simulation. The femoral component was driven under a displacement-controlled scheme to slide along the anterior-posterior (AP) direction on the tibial insert. At each time step, constraint force occurring at the articulating surface was derived from the reaction force at the distal fixation of the tibial baseplate. The force-displacement curve was plotted by combining the results of all time steps to characterize the constraint behavior of the prosthesis. A nonlinear FEA solver (NX Nastran SOL601, Siemens, TX, USA) was used to solve the simulation. In addition, five samples of the prostheses were physically tested per ASTM F1223. Simulation results were compared to the physical testing. Results. The simulation successfully captured the movement of contact location and pressure along the movement of the femoral component. The force-displacement curve predicted by the simulation exhibited a very close hysteresis loop profile as the results of physical testing. Using the curve slope from 0 to 5 mm to characterise the constraint in the most relevant displacement range, the simulation predicted 45.7 N/mm anteriorly and 36.4 N/mm posteriorly, which are less than 10% different from the physical testing results (46.4 N/mm anteriorly and 39.6 N/mm posteriorly). Discussion/Conclusion. This study demonstrated that the simulation was able to closely predict the femorotibial constraint behavior of the TKA prosthesis under ASTM F1223 testing. The simulation results resembled the physical test results not only in the general profile of the curve but also in the magnitude of slope values. The increased difference at the far anterior region could be related to the fact that no material nonlinearity was considered in the current simulation, a factor that could be improved in future studies. A validated simulation method could be very useful in TKA prosthesis design. Since no physical prototypes are required, design evaluation and optimization can be achieved in a much easier and faster manner


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 33 - 33
4 Apr 2023
Pareatumbee P Yew A Koh J Zainul-Abidin S Howe T Tan M
Full Access

To quantify bone-nail fit in response to varying nail placements by entry point translation in straight antegrade humeral nailing using three-dimensional (3D) computational analysis

CT scans of ten cadaveric humeri were processed in 3D Slicer to obtain 3D models of the cortical and cancellous bone. The bone was divided into individual slices each consisting of 2% humeral length (L) with the centroid of each slice determined. To represent straight antegrade humeral nail, a rod consisting of two cylinders with diameters of 9.5mm and 8.5mm and length of 0.22L mm and 0.44L mm respectively joined at one end was modelled. The humeral head apex (surgical entry point) was translated by 1mm in both anterior-posterior and medio-lateral directions to generate eight entry points. Total nail protrusion surface area, maximum nail protrusion distance into cortical shell and top, middle, bottom deviation between nail and intramedullary cavity centre were investigated. Statistical analysis between the apex and translated entry points was conducted using paired t-test.

A posterior-lateral translation was considered as the optimal entry point with minimum protrusion in comparison to the anterior-medial translation experiencing twice the level of protrusion. Statistically significant differences in cortical protrusion were found in anterior-medial and posterior-lateral directions producing increased and decreased level of protrusion respectively compared to the apex. The bottom anterior-posterior deviation distance appeared to be a key predictor of cortical breach with the distal nail being more susceptible. Furthermore, nails with anterior translation generated higher anterior-posterior deviation (>4mm) compared to posterior translation (<3mm).

Aside from slight posterolateral translation of the entry point from the apex, inclusion of a distal posterior-lateral bend into current straight nail design could improve nail fitting within the curved humeral bone, potentially improving distal working length within the flat and narrow medullary canal of the distal humeral shaft.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 1 - 1
1 Jul 2014
Gao B Angibaud L
Full Access

Summary Statement. Femorotibial constraint is a key property of a total knee arthroplasty (TKA) prosthesis and should reflect the intended function of the device. With a validated simulation methodology, this study evaluated the constraint of two TKA prostheses designed for different intentions. Introduction. TKA prostheses are semi-constrained artificial joints. Femorotibial constraint level is a major property of a prosthesis and should be designed to match the device's intended function. Cruciate Retaining (CR) prostheses are usually indicated for patients with a functioning posterior cruciate ligament (PCL). For patients without a fully functioning PCL, CR-Constrained (CRC) prostheses with additional built-in constraint may be indicated. A CRC prosthesis usually consists of a CR femoral component and a tibial insert which has a more conforming sagittal profile to offer an increased femorotibial constraint. This study evaluated the anterior-posterior (AP) constraint behavior of two lines of prostheses (CR and CRC) from a same TKA product family. Using a validated computer simulation approach, multiple sizes of each product line were evaluated. Methods. Both the CR and CRC prostheses are from the same TKA product family (Optetrak Logic, Exactech, FL, USA) and share identical femoral components and tibial baseplates. The CRC tibial inserts have a more conforming sagittal profile than the CR tibial inserts, especially in the anterior aspect. Three sizes (sizes 1, 3, and 5) from each product line were included in this study. Computer simulations using finite element analysis (FEA) were performed to evaluate the femorotibial constraint of each prosthesis per ASTM F1223 standard [1]. The simulation has been validated by comparison with physical testing (more details submitted in a separate paper to CORS 2013). Briefly, FEA models were created using 10-node tetrahedral elements with all materials considered linear elastic. The tibial baseplate was distally fixed and a constant compressive force (710 N) was applied to the femoral component. Nonlinear Surface-Surface-Contact was established at the articulating surfaces, as well as between the tibial insert and the tibial baseplate. A coefficient of friction of 0.1 was assumed for all articulations [2]. The femoral component was driven under a displacement-controlled scheme to slide along AP direction on the tibial insert. Constraint force occurring at the articulation was derived from the reaction force at the distal fixation; thus, the force-displacement curve can be plotted to characterise the constraint behavior of the prosthesis. A nonlinear FEA solver (NX Nastran SOL601, Siemens, TX, USA) was used to solve the simulations. Results. The force-displacement curves predicted by the simulation exhibited the hysteresis loop appearance for both CR and CRC prostheses. The profile of the curves was generally consistent across different sizes for both product lines. The anterior constraint of the CRC prosthesis was significantly greater than the CR prosthesis. The posterior constraint of the CRC prosthesis was also slightly greater. Larger sizes exhibited reduced constraint compared to smaller sizes. Discussion/Conclusion. The increased constraint of the CRC prosthesis revealed in the study is consistent with the geometrical characteristics and the functional intent of the device. The CRC tibial insert is expected to provide significantly greater anterior constraint than the CR prosthesis to prevent paradoxical femoral translation when the patient's PCL is not fully functioning. The CRC tibial insert is also expected to provide slightly increased posterior constraint due to its elevated posterior lip. The observed hysteresis loop appearance is consistent with physical testing and the existence of friction. The reduced constraint on larger sizes is functionally desirable to offer proportional translation freedom. This study demonstrated the effectiveness of the simulation approach in quantifying the constraint behavior of different TKA prosthesis designs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 64 - 64
1 Mar 2013
Allen F Cooper A Grange S Davenport G Marsh D Smitham P
Full Access

Introduction. With an ageing population comes an increased prevalence of osteoporosis and associated fracture. Whilst treatment of the condition following such a fracture is partially effective, primary prevention through screening and appropriate follow-up is the ideal. In order to assess a population's risk of fracture, paper questionnaires would traditionally have to be sent, however this is an wasteful and costly. A more efficient method may be to have patients assess their own FRAX score through a modified computer application. Aim. To investigate the feasibility of patients self-reporting their FRAX score from the use of a touch screen application. Methods. A patient-friendly application based on the FRAX questionnaire was developed for use on iPad. This was then trialled on inpatients and outpatients at the RNOH, Stanmore and at 2 GP's surgeries. A paper questionnaire then was used to assess ease of use of the application. Results. 314 patients completed the iPad application with 68 patients over 55 completing the paper questionnaire. The mean useability score was 2.6 (1-easy, 10-hard). 75% of respondents preferred using a touch screen application than paper or phone surveys and 83% stated they would use the touch screen if it was offered in GP surgeries. Discussion and Conclusion. Touch screen applications are readily used to self-report fracture risk by the majority of the over 55 population. Applications such as these have the potential to collect large amounts of data quickly and cheaply, as well as engaging patients in becoming aware of the risks of osteoporosis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 58 - 58
1 Jan 2017
Varga P Jenni D Inzana J Gueorguiev B Blauth M Windolf M
Full Access

The high risk and the associated high mortality of secondary, contralateral hip fractures [1,2] could justify internal, invasive prophylactic reinforcement of the osteoporotic proximal femur to avoid these injuries in case of a low energy fall. Previous studies have demonstrated high potential of augmentation approaches [3,4,5], but to date there has no ideal solution been found. The development of optimized reinforcement strategies can be aided with validated computer simulation tools that can be used to evaluate new ideas. A validated non-linear finite element (FE) simulation tool was used here to predict the yield and fracture load of twelve osteoporotic or osteopenic proximal femora in sideways fall based on high resolution CT images. Various augmentation strategies using bone cement or novel metal implants were developed, optimized and virtually performed on the bone models. The relative strengthening compared to the non-augmented state was evaluated using case-specific FE analyses. Strengthening effect of the cement-based augmentation was linearly proportional to cement volume and was significantly affected by cement location. With the clinically acceptable 12.6 ± 1.2 ml volume and optimized location of the cement cloud, compared to the non-augmented state, 71 ± 26% (42 – 134%) and 217 ± 166% (83 – 509%) increase in yield force and energy was reached, respectively. These were significantly higher than previously published experimental results using the “central” cement location [5], which could be well predicted by our FE models. The optimized metal implant could provide even higher strengthening effect: 140 ± 39% (76 – 194%) increase in yield force and +357 ± 177% (132 – 691%) increase in yield energy. However, for metal implants, a higher risk of subcapital fractures was indicated. For both cement and metal, the originally weaker bones were strengthened exponentially more compared to the stronger ones. The ideal solution for prophylactic augmentation should provide an appropriate balance between the requirements of being clinically feasible, ethically acceptable and mechanically sufficient. Even with the optimized location, the cement-based approach may not provide enough strengthening effect and adequate reproducibility of the identified optimal cement cloud position may not be achieved clinically. While the metal implant based strategy appears to be able to deliver the required strengthening effect, the ethical acceptance of this more invasive option is questionable. Further development is therefore required to identify the ideal, clinically relevant augmentation strategy. This may involve new cement materials, less invasive metal implants, or a combination of both. The FE simulation approach presented here could help to screen the potential ideas and highlight promising candidates for experimental evaluation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 972 - 975
1 Jul 2006
Spencer JMF Day RE Sloan KE Beaver RJ

Our aim was to assess the intra- and inter-observer reliability in the establishment of the anterior pelvic plane used in imageless computer-assisted navigation. From this we determined the subsequent effects on version and inclination of the acetabular component.

A cadaver model was developed with a specifically-designed rod which held the component tracker at a fixed orientation to the pelvis, leaving the anterior pelvic plane as the only variable. Eight surgeons determined the anterior pelvic plane by palpating and registering the bony landmarks as reference points. The exact anterior pelvic plane was then established by using anatomically-placed bone screws as reference points.

The difference between the surgeons was found to be highly significant (p < 0.001). The variation was significantly larger for anteversion (sd 9.6°) than for inclination (sd 6.3°). The present method for registering pelvic landmarks shows significant inaccuracy, which highlights the need for improved methods of registration before this technique is considered to be safe.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 28 - 28
1 Dec 2020
Tekin SB Karslı B Kurt V Öğümsöğütlü E
Full Access

Evidence that L5 transverse process fracture indicates pelvic instability is insufficient and controversial. Because of unstable pelvis fractures have high mortality rate, they require urgent treatment and good follow-up. The lumbar region is also affected by high-energy traumas in the pelvis region, which causes damage to the muscles and ligamentous structures that adhere to the lumbar transverse process. For this reason, L5 transverse process fracture is thought to be an indicator showing pelvic instability. However, our study shows that this is not like that. This study was carried out in order to investigate the effect of L5 transvers process fracture on pelvic instability and lack of sufficient data in the literature.

Between 2017–2020, 86 Patient who were hospitalized and treated with a diagnosis of pelvic fracture were retrospectively studied in our clinic. Pelvic X-Ray and tomography was taken pre-op for all patient. Demographic features, pre-op and post-op hemoglobin counts, how many units of blood transfusion needed in total, fixation method, surgical intervention, presence of additional injury, mechanism of injury for all patient were analyzed and the patients were categorized by investigating L5 transvers process fracture in their tomography. Fractures of patients were classified according toTyle classification. The patients were divided into two main groups as who stabil and unstabil pelvic fractures and L5 transvers process fracture and without.

On stabil pelvic fractures and unstabil pelvic fractures, in term of instability effects of L5 transvers process fractures and those without were investigated. Also, changes in preop and post op hemoglaobin counts were investigated in pelvis with and without L5 transvers process fractures. With these, in terms of blood transfusion need the patients were evaluated whether there was a difference between those with L5 transvers process fractures and who did not. Again, whether the blood transfusion was statistically different in stable and unstable pelvis fractures was among the parameters looked at. In statistical analysis, no correlation was found between pelvic instability and L5 transvers process fracture. (p=0,933) No statistically significant difference was found in the evalution of blood transfusion between those with and without L5 transvers process fractures. (P=0,409)When the same parameter was evaluated in terms of stability and instability of the pelvis, it was seen that stability did not significantly affect the need for blood transfusion. (P=0,989) Pre-op and post-op hemoglobin changes of the patients who with L5 transvers process fracture and without were also analized. İn the analysis performed, there was no significant difference in patients with and without L5 transvers process fractures on pre-op and post-op hemoglobin values. (p=0.771/p=0.118)However, Postoperative hemoglobin values were significanly lower in patient with L5 transvers process fracture compared to preopetative hemoglobin values. (p=0.001)

L5 transvers process fracture is not a parameter to showing pelvic instability. Stabil and unstabil fractures did not change the need for blood transfusion. The literatüre still needs much more study on this topic.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 39 - 39
17 Nov 2023
FARHAN-ALANIE M Gallacher D Kozdryk J Craig P Griffin J Mason J Wall P Wilkinson M Metcalfe A Foguet P
Full Access

Abstract. Introduction. Component mal-positioning in total hip replacement (THR) and total knee replacement (TKR) can increase the risk of revision for various reasons. Compared to conventional surgery, relatively improved accuracy of implant positioning can be achieved using computer assisted technologies including navigation, patient-specific jigs, and robotic systems. However, it is not known whether application of these technologies has improved prosthesis survival in the real-world. This study aimed to compare risk of revision for all-causes following primary THR and TKR, and revision for dislocation following primary THR performed using computer assisted technologies compared to conventional technique. Methods. We performed an observational study using National Joint Registry data. All adult patients undergoing primary THR and TKR for osteoarthritis between 01/04/2003 to 31/12/2020 were eligible. Patients who received metal-on-metal bearing THR were excluded. We generated propensity score weights, using Sturmer weight trimming, based on: age, gender, ASA grade, side, operation funding, year of surgery, approach, and fixation. Specific additional variables included position and bearing for THR and patellar resurfacing for TKR. For THR, effective sample sizes and duration of follow up for conventional versus computer-guided and robotic-assisted analyses were 9,379 and 10,600 procedures, and approximately 18 and 4 years, respectively. For TKR, effective sample sizes and durations of follow up for conventional versus computer-guided, patient-specific jigs, and robotic-assisted groups were 92,579 procedures over 18 years, 11,665 procedures over 8 years, and 644 procedures over 3 years, respectively. Outcomes were assessed using Kaplan-Meier analysis and expressed using hazard ratios (HR) and 95% confidence intervals (CI). Results. For THR, analysis comparing computer-guided versus conventional technique demonstrated HR of 0.771 (95%CI 0.573–1.036) p=0.085, and 0.594 (95%CI 0.297–1.190) p=0.142, for revision for all-causes and dislocation, respectively. When comparing robotic-assisted versus conventional technique, HR for revision for all-causes was 0.480 (95%CI 0.067 –3.452) p=0.466. For TKR, compared to conventional surgery, HR for all-cause revision for procedures performed using computer guidance and patient-specific jigs were 0.967 (95% CI 0.888–1.052) p=0.430, and 0.937 (95% CI 0.708–1.241) p=0.65, respectively. HR for analysis comparing robotic-assisted versus conventional technique was 2.0940 (0.2423, 18.0995) p = 0.50. Conclusions. This is the largest study investigating this topic utilising propensity score analysis methods. We did not find a statistically significant difference in revision for all-causes and dislocation although these analyses are underpowered to detect smaller differences in effect size between groups. Additional comparison for revision for dislocation between robotic-assisted versus conventionally performed THR was not performed as this is a subset of revision for all-causes and wide confidence intervals were already observed for that analysis. It is also important to mention this NJR analysis study is of an observational study design which has inherent limitations. Nonetheless, this is the most feasible study design to answer this research question requiring use of a large data set due to revision being a rare outcome. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 102 - 102
2 Jan 2024
Ambrosio L
Full Access

In the last decades, the use of artificial intelligence (AI) has been increasingly investigated in intervertebral disc degeneration (IDD) and chronic low back pain (LBP) research. To date, several AI-based cutting-edge technologies, such as computer vision, computer-assisted diagnosis, decision support system and natural language processing have been utilized to optimize LBP prevention, diagnosis, and treatment. This talk will provide an outline on contemporary AI applications to IDD and LBP research, with a particular attention towards actual knowledge gaps and promising innovative tools


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 51 - 51
17 Apr 2023
Al-Musawi H Sammouelle E Manara J Clark D Eldridge J
Full Access

The aim is to investigate if there is a relation between patellar height and knee flexion angle. For this purpose we retrospectively evaluated the radiographs of 500 knees presented for a variety of reasons. We measure knee flexion angle using a computer-generated goniometer. Patellar height was determined using computer generated measurement for the selected ratios, namely, the Insall–Salvati (I/S), Caton–Deschamps (C/D) and Blackburne–Peel (B/P) indices and Modified I/S Ratio. A search of an NHS hospital database was made to identify the knee x rays for patients who were below the age of forty. A senior knee surgeon (DC) supervised three trainee trauma and orthopaedics doctors (HA, JM, ES) working on this research. Measurements were made on the Insall–Salvati (I/S), Caton–Deschamps (C/D) and Blackburne–Peel (B/P) indices and Modified I/S Ratio. The team leader then categorised the experimental measurement of patients’ knee flexion angle into three groups. This categorisation was according to the extent of knee flexion. The angles were specifically, 10.1 to 20, 20.1 to 30, and 30.1 to 40 degrees of knee flexion. Out of the five-hundred at the start of the investigation, four hundred and eighteen patients were excluded because they had had either an operation on the knee or traumatic fracture that was treated conservatively


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 2 - 2
2 Jan 2024
Ditmer S Dwenger N Jensen L Ghaffari A Rahbek O
Full Access

The most important outcome predictor of Legg-Calvé-Perthes disease (LCPD) is the shape of the healed femoral head. However, the deformity of the femoral head is currently evaluated by non-reproducible, categorical, and qualitative classifications. In this regard, recent advances in computer vision might provide the opportunity to automatically detect and delineate the outlines of bone in radiographic images for calculating a continuous measure of femoral head deformity. This study aimed to construct a pipeline for accurately detecting and delineating the proximal femur in radiographs of LCPD patients employing existing algorithms. To detect the proximal femur, the pretrained stateof-the-art object detection model, YOLOv5, was trained on 1580 manually annotated radiographs, validated on 338 radiographs, and tested on 338 radiographs. Additionally, 200 radiographs of shoulders and chests were added to the dataset to make the model more robust to false positives and increase generalizability. The convolutional neural network architecture, U-Net, was then employed to segment the detected proximal femur. The network was trained on 80 manually annotated radiographs using real-time data augmentation to increase the number of training images and enhance the generalizability of the segmentation model. The network was validated on 60 radiographs and tested on 60 radiographs. The object detection model achieved a mean Average Precision (mAP) of 0.998 using an Intersection over Union (IoU) threshold of 0.5, and a mAP of 0.712 over IoU thresholds of 0.5 to 0.95 on the test set. The segmentation model achieved an accuracy score of 0.912, a Dice Coefficient of 0.937, and a binary IoU score of 0.854 on the test set. The proposed fully automatic proximal femur detection and segmentation system provides a promising method for accurately detecting and delineating the proximal femoral bone contour in radiographic images, which is necessary for further image analysis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 82 - 82
2 Jan 2024
Barcik J Ernst M Buchholz T Constant C Mys K Epari D Zeiter S Gueorguiev B Windolf M
Full Access

Secondary bone healing is impacted by the extent of interfragmentary motion at the fracture site. It provides mechanical stimulus that is required for the formation of fracture callus. In clinical settings, interfragmentary motion is induced by physiological loading of the broken bone – for example, by weight-bearing. However, there is no consensus about when mechanical stimuli should be applied to achieve fast and robust healing response. Therefore, this study aims to identify the effect of the immediate and delayed application of mechanical stimuli on secondary bone healing. A partial tibial osteotomy was created in twelve Swiss White Alpine sheep and stabilized using an active external fixator that induced well-controlled interfragmentary motion in form of a strain gradient. Animals were randomly assigned into two groups which mimicked early (immediate group) and late (delayed group) weight-bearing. The immediate group received daily stimulation (1000 cycles/day) from the first day post-op and the delayed group from the 22nd day post-op. Healing progression was evaluated by measurements of the stiffness of the repair tissue during mechanical stimulation and by quantifying callus area on weekly radiographs. At the end of the five weeks period, callus volume was measured on the post-mortem high-resolution computer tomography (HRCT) scan. Stiffness of the repair tissue (p<0.05) and callus progression (p<0.01) on weekly radiographs were significantly larger for the immediate group compared to the delayed group. The callus volume measured on the HRCT was nearly 3.2 times larger for the immediate group than for the delayed group (p<0.01). This study demonstrates that the absence of immediate mechanical stimuli delays callus formation, and that mechanical stimulation already applied in the early post-op phase promotes bone healing


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 62 - 62
11 Apr 2023
Preutenborbeck M Wright P Loughran G Bishop N
Full Access

Orthopaedic impaction-instruments are used to drive implants into the bone of the patient. Pre-clinical experimental testing protocols and computer models of those are used to assess robustness and functional efficiency of such instruments. This generally involves impaction of the instrument mounted on a substrate that should represent the mechanics of the patient. In this study, the effects of the substrate on stressing of the impaction-instruments were investigated using dynamic finite element analysis. Model results were compared with experimental data from lab protocols, which have been derived to recreate the mechanics of cadaveric implantations, which represent clinical conditions. FEA models of selected experimental protocols were created in which a simplified instrument was impacted on substrates with varying material properties and boundary conditions. After impaction, the instrument settled into a modal vibration which then decayed over time. The resulting axial strain data from the computational model was compared to strain-gauge data collected from experimental measurements. Strain signal amplitude, frequency and decay were compared. The damping-ratio was derived from the decay of the strain signal. The computational model slightly over-predicted the initial experimental strain amplitudes in all cases, but the frequency of the cyclic strain signals matched. However, the model underestimated the experimentally measured rate of signal decay. Inclusion of implant seating and soft-tissue conditions had little effect on decay. Clinical failures of impaction-instruments may be related to multiple fatigue cycles for each impaction and should be modelled accurately to allow failure prediction. Any soft substrate results in an impedance mismatch at the instrument interface, which reflects the pressure wave and causes vibration with a frequency related to the speed-of-sound in the instrument, and its geometry. While this could be accurately modelled computationally, signal decay was underestimated. Further experimental quantification of energy losses will be important to understand vibration decay


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 104 - 104
14 Nov 2024
Amirouche F Kim S Mzeihem M Nyaaba W Mungalpara N Mejia A Gonzalez M
Full Access

Introduction. The human wrist is a highly complex joint, offering extensive motion across various planes. This study investigates scapholunate ligament (SLL) injuries’ impact on wrist stability and arthritis risks using cadaveric experiments and the finite element (FE) method. It aims to validate experimental findings with FE analysis results. Method. The study utilized eight wrist specimens on a custom rig to investigate Scapho-Lunate dissociation. Contact pressure and flexion were measured using sensors. A CT-based 3D geometry reconstruction approach was used to create the geometries needed for the FE analysis. The study used the Friedman test with pairwise comparisons to assess if differences between testing conditions were statistically significant. Result. The study found significant variations in scaphoid and lunate bone movement based on ligament condition. Full tears increased scapholunate distance in the distal-proximal direction and decreased in the medial-lateral direction. Lunate angles shifted from flexion to extension with fully torn ligaments. Conversely, the scaphoid shifted significantly from extension to flexion with full tears. A proximal movement was observed in the distal-proximal direction in all groups, with significant differences in the partial tear group. Lateral deviation of the scaphoid and lunate occurred with ligament damage, being more pronounced in the partial tear group. All groups exhibited statistically significant movement in the volar direction, with the full tear group showing the least movement. Also, radiocarpal joint and finger contact pressure and contact area were studied. Whereas the differences in contact area were not significant, scapholunate ligament tears resulted in significantly decreased finger contact pressures. FEA confirmed these findings, showing notable peak radiocarpal contact pressure differences between intact and fully torn ligaments. Conclusion. Our study found that SLL damage alters wrist stability, potentially leading to early arthritis. The FEA model confirmed these findings, indicating the potential for the clinical use of computer models from CT scans for treatment planning