header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_1 | Pages 12 - 12
1 Jan 2014
Bali N Maclean S Prem H
Full Access

Purpose. To establish the early outcome, satisfaction and complications of sinus tarsi implants in the management of symptomatic flexible flatfeet for a paediatric population. Methods and results. We included all patients aged 18 years or less who were treated for flexible flatfeet with a sinus tarsi implant between January 2010 and June 2012. We excluded patients who had a history of clubfeet or tarsal coalition. 34 patients had 59 implants. The mean age at surgery was 13.7 yrs (9–17 yrs), with mean follow-up of 22 months (range 10–35). Mean AOFAS improved from 65.7 to 87.9 (p<0.001), with an improvement in AOFAS pain scores (p=0.0001). Radiographic correction occurred in all feet, with average improvement of the anteroposterior talar-second metatarsal angle of 16 degrees, and the lateral talar-first metatarsal angle of 9 degrees. Implant placement satisfaction rate was 86%, with 81% claiming that they would have the procedure again. Complications included peroneal spasm (8%), extrusion (7%), revision (5%), and removal (5%). Peroneal spasm was recalcitrant in 3 of the 5 cases, and those with spasm had a higher average forefoot abduction measurement (35 degrees) than the remaining treated cases (25 degrees). Conclusion. In paediatric patients with flexible flatfeet, utilisation of the sinus tarsi implant has good short-term outcome, with our failure and revision rates comparable to other published studies in the adult population. We introduce the concept of isolated subtalar hyperlaxity which appeared to be a distinct etiological factor. A learning curve in assessing implant size was noted. Overcorrection and implant migration were the indications for revision surgery. Severe forefoot abduction appears to have a poorer outcome, and may be associated with peroneal spasm. Level of evidence: IV


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1048 - 1055
1 Aug 2020
Cox I Al Mouazzen L Bleibleh S Moldovan R Bintcliffe F Bache CE Thomas S

Aims

The Fassier Duval (FD) rod is a third-generation telescopic implant for children with osteogenesis imperfecta (OI). Threaded fixation enables proximal insertion without opening the knee or ankle joint. We have reviewed our combined two-centre experience with this implant.

Methods

In total, 34 children with a mean age of five years (1 to 14) with severe OI have undergone rodding of 72 lower limb long bones (27 tibial, 45 femoral) for recurrent fractures with progressive deformity despite optimized bone health and bisphosphonate therapy. Data were collected prospectively, with 1.5 to 11 years follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 273 - 276
1 Feb 2010
Ballal MS Bruce CE Nayagam S

A total of 25 children (37 legs and 51 segments) with coronal plane deformities around the knee were treated with the extraperiosteal application of a flexible two-hole plate and screws. The mean age was 11.6 years (5.5 to 14.9), the median angle of deformity treated was 8.3° and mean time for correction was 16.1 months (7 to 37.3). There was a mean rate of correction of 0.7° per month in the femur (0.3° to 1.5°), 0.5° per month in the tibia (0.1° to 0.9°) and 1.2° per month (0.1° to 2.2°) if femur and tibia were treated concurrently. Correction was faster if the child was under 10 years of age (p = 0.05). The patients were reviewed between six and 32 months after plate removal. One child had a rebound deformity but no permanent physeal tethers were encountered.

The guided growth technique, as performed using a flexible titanium plate, is simple and safe for treating periarticular deformities of the leg.