Advertisement for orthosearch.org.uk
Results 1 - 20 of 127
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 898 - 906
1 Sep 2024
Kayani B Wazir MUK Mancino F Plastow R Haddad FS

Aims. The primary objective of this study was to develop a validated classification system for assessing iatrogenic bone trauma and soft-tissue injury during total hip arthroplasty (THA). The secondary objective was to compare macroscopic bone trauma and soft-tissues injury in conventional THA (CO THA) versus robotic arm-assisted THA (RO THA) using this classification system. Methods. This study included 30 CO THAs versus 30 RO THAs performed by a single surgeon. Intraoperative photographs of the osseous acetabulum and periacetabular soft-tissues were obtained prior to implantation of the acetabular component, which were used to develop the proposed classification system. Interobserver and intraobserver variabilities of the proposed classification system were assessed. Results. The BOne trauma and Soft-Tissue Injury classification system in total Hip arthroplasty (BOSTI Hip) grades osseous acetabular trauma and periarticular muscle damage during THA. The classification system has an interclass correlation coefficient of 0.90 (95% CI 0.86 to 0.93) for interobserver agreement and 0.89 (95% CI 0.84 to 0.93) for intraobserver agreement. RO THA was associated with improved BOSTI Hip scores (p = 0.002) and more pristine osseous surfaces in the anterior superior (p = 0.001) and posterior superior (p < 0.001) acetabular quadrants compared with CO THA. There were no differences between the groups in relation to injury to the gluteus medius (p = 0.084), obturator internus (p = 0.241), piriformis (p = 0.081), superior gamellus (p = 0.116), inferior gamellus (p = 0.132), quadratus femoris (p = 0.208), and vastus lateralis (p = 0.135), but overall combined muscle injury was reduced in RO THA compared with CO THA (p = 0.023). Discussion. The proposed BOSTI Hip classification provides a reproducible grading system for stratifying iatrogenic bone trauma and soft-tissue injury during THA. RO THA was associated with improved BOSTI Hip scores, more pristine osseous acetabular surfaces, and reduced combined periarticular muscle injury compared with CO THA. Further research is required to understand if these intraoperative findings translate to differences in clinical outcomes between the treatment groups. Cite this article: Bone Joint J 2024;106-B(9):898–906


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 38 - 38
1 May 2018
Magra M McConnell J Syed F Saunders P Young S
Full Access

Introduction. Undersizing of an uncemented femoral stem is a post-operative description of a radiograph with unclear clinical importance. It may not always translate into a suboptimal clinical outcome. Aim. To describe a novel classification system of undersizing in a fully hydroxyapatite coated femoral implant, assess if it could be reliably reported between observers, and describe a simple way to assess the degree of undersizing on an AP radiograph. Methods. A retrospective review of 1000 consecutive total hip arthroplasties was conducted. Two investigators reviewed post-operative radiographs independently for stem undersizing. The data was tested for inter and intra-observer agreement using the Kappa method. Results. Undersizing was classified as:. Varus - Stem in contact proximally with medial calcar, and distally with lateral cortex. Valgus - Stem in contact proximally with lateral cortex, and distally with medial cortex. Uniform - Continuous margin around the stem of at least one-half tip width of the stem throughout. Champagne flute - Distal stem fills the narrow diaphysis with insufficient bony contact at the wide metaphysis. If varus or valgus undersizing was present we described the formation of two triangles of excess cancellous space around the implant, each having overlapping apices signifying undersizing by at least two sizes. 32% of the stems were undersized with Kappa demonstrating very good (89%) to good (86%) inter and intra observer agreement respectively. 50% of undersized stems were uniformly undersized, 36% were varus, 6% valgus, and 8% were in a champagne fluted shaped femur. A higher percentage of the lateralised (KLA) stems were undersized compared to other neck configurations (40%). 54% of these were varus undersized and this increased the offset up to 2cm. Conclusion. We describe a classification system for undersizing in hip arthroplasty. KLA stems have an increased tendency to be undersized in varus, thereby increasing the overall offset


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 1 - 1
1 May 2019
Watkins C Ghosh K Bhatnagar S Rankin K Weir D Hashmi M Holland J
Full Access

Background. Total hip arthroplasty (THA) in patients with congenital dysplasia of the hip (CDH) is complex and challenging. The Crowe and Hartofilakidis classification systems are the most commonly used. However, neither encompasses the whole spectrum of disease and deformity and therefore does not guide modern surgical options. We present a new classification system which aims to guide surgical strategy by focusing on the three main areas of disease and deformity: Cup defect; De-rotation of femoral neck ante-version; Height of femoral subluxation. Each component is graded from 1–3 based on the severity of deformity and the potential surgical strategy required (with 3 being the most severe). A total numerical score will reflect the overall degree of difficulty which may be used when assessing surgical outcomes. The aim of this study is to assess the reliability of this new adult CDH classification system in the setting of THA. Study design and Methods. A sample size calculation showed 28 evaluations were required to reach a power of 85% (based on a kappa value of 0.4). The anterior-posterior pelvis and lateral hip radiographs of 30 hips, in 26 patients were evaluated by three Consultant Orthopaedic Surgeons using the classification detailed in table 1. A second evaluation, with the case order randomised, was performed after a minimum period of 1month. Randolph's free multi-rater Kappa co-efficient was used to assess for inter and intra- observer reliability and 95% confidence intervals were calculated. Results. The results of the Inter and intra–observer reliability for each classification component and for each rater respectively are shown in table 2 and 3. Conclusions. In comparison with other studies our reliability results were poorer when compared to the Hartofilakidis and Crowe classification systems. It was reported by the participants that our system enabled a more logical breakdown of the component deformities to address when performing THA in these hips. As with the Paprosky system for revision hip arthroplasty, this X-ray classification is intended as a practical pre-op guide to planning for all eventualities. Limitations due to level of observer experience and finer intra-operative judgements may alter the final result, but the essence is to understand the anatomical pitfalls enabling appropriate surgical planning and a total score against which to judge outcomes. For any figures or tables, please contact the authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 332 - 336
1 Mar 2011
Konan S Rayan F Meermans G Witt J Haddad FS

There have been considerable recent advances in the understanding and management of femoroacetabular impingement and associated labral and chondral pathology. We have developed a classification system for acetabular chondral lesions. In our system, we use the six acetabular zones previously described by Ilizaliturri et al. The cartilage is then graded on a scale of 0 to 4 as follows: grade 0, normal articular cartilage lesions; grade 1, softening or wave sign; grade 2, cleavage lesion; grade 3, delamination; and grade 4, exposed bone. The site of the lesion is further classed as A, B or C based on whether the lesion is less than one-third of the distance from the acetabular rim to the cotyloid fossa, one-third to two-thirds of the same distance and greater than two-thirds of the distance, respectively. In order to validate the classification system, six surgeons graded ten video recordings of hip arthroscopy. Our findings showed a high intra-observer reliability of the classification system with an intraclass correlation coefficient of 0.81 and a high interobserver reliability with an intraclass correlation coefficient of 0.88. We have developed a simple reproducible classification system for lesions of the acetabular cartilage, which it is hoped will allow standardised documentation to be made of damage to the articular cartilage, particularly that associated with femoroacetabular impingement


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims. This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems. Methods. Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs. Results. Interobserver reliability percentage agreement was 58.5% and the overall kappa value was 0.442 (moderate agreement). Lowest kappa values were seen for type B fractures (0.095 to 0.360). The mean intraobserver reliability kappa value was 0.672 (0.447 to 0.867), indicating substantial agreement. Validity percentage agreement was 65.7% and the mean kappa value was 0.300 (0.160 to 0.4400) indicating only fair agreement. Conclusion. This study demonstrates that the UCS is unsatisfactory for the classification of PFFs around PTS stems, and that it has considerably lower reliability and validity than previously described for other stem types. Radiological PTS stem loosening in the presence of PFF is poorly defined and formal intraoperative testing of stem stability is recommended. Cite this article: Bone Joint J 2021;103-B(8):1339–1344


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 713 - 716
1 Jun 2014
Duncan CP Haddad FS

Periprosthetic fractures are an increasingly common complication following joint replacement. The principles which underpin their evaluation and treatment are common across the musculoskeletal system. The Unified Classification System proposes a rational approach to treatment, regardless of the bone that is broken or the joint involved. Cite this article: Bone Joint J 2014;96-B:713–16


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 43 - 43
1 Jun 2016
Mehta N Reddy G Goldsmith T Ramakrishnan M
Full Access

Background. Sub-trochanteric fractures are challenging to treat due to various anatomical and biomechanical factors. High tensile forces contribute to the challenge of fracture reduction. Intramedullary nailing has become the treatment of choice. If anatomical reduction is not achieved, any mal-alignment will predispose to implant failure. Open reduction with cerclage wires can add to construct stability and improve the quality of reduction. There is no consensus or classification to guide surgeons on when to perform open reduction, which is often performed intra-operatively when closed reduction fails often with no planning. This can lead to intraoperative delays as theatre staff would not have prepared the correct equipment necessary for open reduction. Objectives. The purpose of this study was to assess outcomes of closed and open reduction of traumatic sub-trochanteric fractures treated with intramedullary nailing and to propose a new classification system to dictate management. Methods. After a review of current classification systems, a 3-tier classification was proposed (Type 1, 2 and 3). Type 1 indicated a transverse fracture, Type 2 was a spiral fracture with an intact posterior and medial wall and a Type 3 fracture were fractures with no posterior and/or medial walls. Over a two-year period (2013–2015), patients with sub trochanteric fractures were classified into Type 1, 2 or 3 injuries based on radiographic appearances by two senior clinicians. Patients with Type 3 injuries were divided into two groups based on whether they were treated with open or closed reduction. A clinical and radiographic review was performed. The primary outcome measure was the incidence of implant failure, whereas secondary outcome measures were related to fracture reduction. Statistical analysis was performed using GraphPad Prism Version 6 (GraphPad Software Inc. California, USA). Fisher's exact test was used for independent categorical data and Mann–U Whitney for continuous nonparametric data. Statistical significance was set at p<0.05. Results. 75 patients had intramedullary nailing for subtrochanteric fractures over the study period with a mean age of 82.6 years. There were 48 patients who had a Type 3 fracture pattern with a deficient medial and/or posterior wall. Reduction was achieved open with cerclage wires in 42% of patients (n=20 and closed in 58% (n=28). Overall there were a total of 18 (37.5%) major complications. In patients treated with closed reduction, 9 patients suffered mechanical complications (6 distal locking screw failures, 3 lag screw cut outs). There was a significantly increased risk of implant failure in patients treated with closed reduction compared to open reduction (p=0.006). No cases with cerclage wire had implant failure. Open reduction with cerclage wires improved the quality of reduction (p=0.0001) compared with closed reduction. There was no significant increase in operating time in patients treated with cerclage wires (p=0.4334). Conclusions. Open reduction with cerclage wires should be considered in patients with Type 3 sub-trochanteric fractures as it has shown to significantly reduce the risk of implant failure and improve the quality of reduction with no significant increase in operating time


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 41 - 41
1 Oct 2019
Braly HL Rodriguez D Schroder S Thomas J Delgadillo LE Noble PC
Full Access

Introduction. The Vancouver Classification System presents a systematic approach to classification of periprosthetic fractures of the proximal femur (PFPFs) that has been validated in previous studies. However, with the introduction of tapered fluted stems and cable plates since the introduction of the Vancouver System, the connection between fracture class and the preferred method of treatment is often unclear. The present study was undertaken to identify fracture patterns surrounding contemporary femoral stems and the relationship between the current method of treatment and the Vancouver Class of the periprosthetic fracture. Methods. Three experienced joint surgeons collected plain radiographs (AP and lateral) and CT/MR scans (n=40) from 72 cases of Vancouver A or B periprosthetic fractures performed over the period 2016–2018. We identified the mode of primary stem fixation and the Vancouver grade of the fracture (A, B1, B2 or B3). Two independent investigators examined all imaging studies and the intraoperative records and recorded: (i) and the location and distribution of the fracture surfaces, and (ii) the presence of incomplete cortical fractures that had initiated within the femoral cortex without completing propagation and (iii) the method of operative treatment. These data were analyzed to examine the incidence of fractures within more than one femoral zone and differences in the fracture patterns corresponding to each Vancouver class. Results. One fifth (21%) of fractures were Type A with the remainder consisting predominantly of Type B2 (39%), with approximately equal proportions of Type B1 (22%) and B3 (18%) fractures. In almost half of Type B2 fractures (a loose femoral stem and a fracture adjacent to the prosthesis), fractures were also present within the metaphysis (ie. Type A+B). In the presence of a cementless femoral stem, fractures often occurred adjacent to the uncoated surface of the stem distal to the proximal ingrowth surface. Type B2 and B3 femurs had similar fracture patterns and degrees of comminution, though their method of treatment differed significantly. Incomplete fractures were identified in every Vancouver class (entire sample: 22%), especially in association with loose stems in poor quality bone (Type B3; 38% of cases). Conclusions. Approximately two-thirds of periprosthetic femoral fractures involve a loose femoral component (ie Types B2 and B3), though bone quality impacts operative treatment. In cementless stems, Vancouver Type B fractures often occur in the unbonded diaphysis between the distal edge of the ingrowth surface and immediately below the stem tip. Incomplete fractures are present in a surprising proportion of cases, suggesting that careful examination of imaging studies is needed to prevent fracture propagation due to inadequate fixation. CT scans are a useful adjunct to supplement plain radiographs. For any tables or figures, please contact the authors directly


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1472 - 1477
1 Nov 2014
Vioreanu MH Parry MC Haddad FS Duncan CP

The Unified Classification System (UCS) emphasises the key principles in the assessment and management of peri-prosthetic fractures complicating partial or total joint replacement. We tested the inter- and intra-observer agreement for the UCS as applied to the pelvis and femur using 20 examples of peri-prosthetic fracture in 17 patients. Each subtype of the UCS was represented by at least one case. Specialist orthopaedic surgeons (experts) and orthopaedic residents (pre-experts) assessed reliability on two separate occasions. For the pelvis, the UCS showed inter-observer agreement of 0.837 (95% confidence intervals (CI) 0.798 to 0.876) for the experts and 0.728 (95% CI 0.689 to 0.767) for the pre-experts. The intra-observer agreement for the experts was 0.861 (95% CI 0.760 to 0.963) and 0.803 (95% 0.688 to 0.918) for the pre-experts. For the femur, the UCS showed an inter-observer kappa value of 0.805 (95% CI 0.765 to 0.845) for the experts and a value of 0.732 (95% CI 0.690 to 0.773) for the pre-experts. The intra-observer agreement was 0.920 (95% CI 0.867 to 0.973) for the experts, and 0.772 (95% CI 0.652 to 0.892) for the pre-experts. This corresponds to a substantial and ‘almost perfect’ inter- and intra-observer agreement for the UCS for peri-prosthetic fractures of the pelvis and femur. We hope that unifying the terminology of these injuries will assist in their assessment, treatment and outcome. Cite this article: Bone Joint J 2014;96-B:1472–7


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 70 - 70
1 Oct 2018
Paprosky WG Sheth NP Melnic CM Brown NM Sporer SM
Full Access

Introduction. During revision total hip arthroplasty, successful treatment of acetabular bone loss with an associated chronic pelvic discontinuity is dependent upon the remaining bone stock, stability of the construct, potential for biologic fixation, and healing of the discontinuity. Several techniques have been described for the treatment of this clinical entity; the authors recommend the use of acetabular distraction technique in conjunction with a jumbo cup with or without augments. The authors recently evaluated the minimum two-year follow-up of acetabular distraction technique for the treatment of chronic pelvic discontinuity. In the process, a chronic pelvic discontinuity classification was created based on the type of reconstruction required. The purpose of this study is to introduce the initial observations of this novel classification system. Methods. Patients from two academic institutions undergoing acetabular distraction for chronic pelvic discontinuity were identified between January 2002 and December 2013 with minimum 2-year follow-up. Radiographs at latest follow-up were compared to serial radiographs from the index surgery. Data was collected by chart review in accordance with institutional IRB protocol from both institutions. Results. A cohort of 32 patients had minimum 2-year (range, 2.1–13.3 years) follow-up. Mean patient age was 67 years (range, 44–86) and 87% were female. All patients had a chronic pelvic discontinuity with the following bone loss patterns: 7 (22%) type IIC, 5 (15%) type IIIA and 20 (63%) type IIIB. At time of final follow-up, radiographs demonstrated 22 of 32 patients (69%) had evidence of a healed discontinuity. Chronic Pelvic Discontinuity Classification. The classification mirrors the Paprosky classification and requires a more complex reconstruction with each progressive type. For the 20 patients with a type IIIB acetabular bone loss pattern, the new classification was applied. The distribution of classification types was as follows: type I 6 (30%); type II 5 (25%); type IIIA 4 (20%); type IIIB 5 (25%); and type IV 0. Overall, 70% (14) patients required the use of an augment for acetabular reconstruction. Conclusions. Acetabular distraction has been established as an effective method by which to treat chronic pelvic discontinuity. The new classification helps to determine the complexity of reconstruction required for each discontinuity, especially when assessing the most severe acetabular defects (Paprosky IIIB). The authors advocate acetabular distraction with a jumbo cup and modular porous metal augments as the preferred treatment for acetabular bone loss with associated chronic pelvic discontinuity. According to the new classification, the likelihood of utilizing augment(s) increases with severity of bone loss. Future studies are required to validate this new chronic pelvic discontinuity classification


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 579 - 583
1 May 2008
Yiannakopoulos CK Chougle A Eskelinen A Hodgkinson JP Hartofilakidis G

Our study evaluated the reliability of the Crowe and Hartofilakidis classification systems for developmental dysplasia of the hip in adults. The anteroposterior radiographs of the pelvis of 145 patients with 209 osteoarthritic hips were examined twice by three experienced hip surgeons from three European countries and the abnormal hips were rated using both classifications. The inter- and intra-observer agreement was calculated. Interobserver reliability was evaluated using weighted and unweighted kappa coefficients and for the Crowe classification, among the three pairs there was a minimum kappa coefficient with linear weighting of 0.90 for observers A and C and a maximum kappa coefficient of 0.92 for observers B and C. For the Hartofilakidis classification, the minimum kappa value was 0.85 for observers A and B, and the maximum value was 0.93 for observers B and C. With regard to intra-observer reliability, the kappa coefficients with linear weighting between the two evaluations of the same observer ranged between 0.86 and 0.95 for the Crowe classification and between 0.80 and 0.93 for the Hartofilakidis classification. The reliability of both systems was substantial to almost perfect both for serial measurements by individual readers and between different readers, although the information offered was dissimilar


Bone & Joint Open
Vol. 3, Issue 5 | Pages 423 - 431
1 May 2022
Leong JWY Singhal R Whitehouse MR Howell JR Hamer A Khanduja V Board TN

Aims. The aim of this modified Delphi process was to create a structured Revision Hip Complexity Classification (RHCC) which can be used as a tool to help direct multidisciplinary team (MDT) discussions of complex cases in local or regional revision networks. Methods. The RHCC was developed with the help of a steering group and an invitation through the British Hip Society (BHS) to members to apply, forming an expert panel of 35. We ran a mixed-method modified Delphi process (three rounds of questionnaires and one virtual meeting). Round 1 consisted of identifying the factors that govern the decision-making and complexities, with weighting given to factors considered most important by experts. Participants were asked to identify classification systems where relevant. Rounds 2 and 3 focused on grouping each factor into H1, H2, or H3, creating a hierarchy of complexity. This was followed by a virtual meeting in an attempt to achieve consensus on the factors which had not achieved consensus in preceding rounds. Results. The expert group achieved strong consensus in 32 out of 36 factors following the Delphi process. The RHCC used the existing Paprosky (acetabulum and femur), Unified Classification System, and American Society of Anesthesiologists (ASA) classification systems. Patients with ASA grade III/IV are recognized with a qualifier of an asterisk added to the final classification. The classification has good intraobserver and interobserver reliability with Kappa values of 0.88 to 0.92 and 0.77 to 0.85, respectively. Conclusion. The RHCC has been developed through a modified Delphi technique. RHCC will provide a framework to allow discussion of complex cases as part of a local or regional hip revision MDT. We believe that adoption of the RHCC will provide a comprehensive and reproducible method to describe each patient’s case with regard to surgical complexity, in addition to medical comorbidities that may influence their management. Cite this article: Bone Jt Open 2022;3(5):423–431


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 17 - 24
1 Jul 2021
Vigdorchik JM Sharma AK Buckland AJ Elbuluk AM Eftekhary N Mayman DJ Carroll KM Jerabek SA

Aims. Patients with spinal pathology who undergo total hip arthroplasty (THA) have an increased risk of dislocation and revision. The aim of this study was to determine if the use of the Hip-Spine Classification system in these patients would result in a decreased rate of postoperative dislocation in patients with spinal pathology. Methods. This prospective, multicentre study evaluated 3,777 consecutive patients undergoing THA by three surgeons, between January 2014 and December 2019. They were categorized using The Hip-Spine Classification system: group 1 with normal spinal alignment; group 2 with a flatback deformity, group 2A with normal spinal mobility, and group 2B with a stiff spine. Flatback deformity was defined by a pelvic incidence minus lumbar lordosis of > 10°, and spinal stiffness was defined by < 10° change in sacral slope from standing to seated. Each category determined a patient-specific component positioning. Survivorship free of dislocation was recorded and spinopelvic measurements were compared for reliability using intraclass correlation coefficient. Results. A total of 2,081 patients met the inclusion criteria. There were 987 group 1A, 232 group 1B, 715 group 2A, and 147 group 2B patients. A total of 70 patients had a lumbar fusion, most had L4-5 (16; 23%) or L4-S1 (12; 17%) fusions; 51 patients (73%) had one or two levels fused, and 19 (27%) had > three levels fused. Dual mobility (DM) components were used in 166 patients (8%), including all of those in group 2B and with > three level fusions. Survivorship free of dislocation at five years was 99.2% with a 0.8% dislocation rate. The correlation coefficient was 0.83 (95% confidence interval 0.89 to 0.91). Conclusion. This is the largest series in the literature evaluating the relationship between hip-spine pathology and dislocation after THA, and guiding appropriate treatment. The Hip-Spine Classification system allows surgeons to make appropriate evaluations preoperatively, and it guides the use of DM components in patients with spinopelvic pathology in order to reduce the risk of dislocation in these high-risk patients. Cite this article: Bone Joint J 2021;103-B(7 Supple B):17–24


Bone & Joint Open
Vol. 4, Issue 8 | Pages 551 - 558
1 Aug 2023
Thomas J Shichman I Ohanisian L Stoops TK Lawrence KW Ashkenazi I Watson DT Schwarzkopf R

Aims. United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on implant survivorship, postoperative outcomes, radiological outcomes, and osseointegration following treatment of THA UCS B2 and B3 periprosthetic fractures. Methods. A retrospective review was conducted of all patients who underwent revision THA (rTHA) for periprosthetic UCS B2 and B3 periprosthetic fracture who received a single design monoblock fluted tapered titanium stem at two large, tertiary care, academic hospitals. A total of 72 patients met inclusion and exclusion criteria (68 UCS B2, and four UCS B3 fractures). Primary outcomes of interest were radiological stem subsidence (> 5 mm), radiological osseointegration, and fracture union. Sub-analysis was also done for 46 patients with minimum one-year follow-up. Results. For the total cohort, stem osseointegration, fracture union, and stem subsidence were 98.6%, 98.6%, and 6.9%, respectively, at latest follow-up (mean follow-up 27.0 months (SD 22.4)). For patients with minimum one-year of follow-up, stem osseointegration, fracture union, and stem subsidence were 97.8%, 97.8%, and 6.5%, respectively. Conclusion. Monoblock fluted stems can be an acceptable modality for the management of UCS B2 periprosthetic fractures in rTHAs due to high rates of stem osseointegration and survival, and the low rates of stem subsidence, and revision. Further research on the use of this stem for UCS B3 periprosthetic fractures is warranted to determine if the same conclusion can be made for this fracture pattern. Cite this article: Bone Jt Open 2023;4(8):551–558


Aims. The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an intracapsular hip fracture. Methods. This retrospective study included hip fracture patients aged 50 years and older treated with Exeter (PTS) bipolar hemiarthroplasty between 2019 and 2022. Patient demographics, place of domicile, fracture type, delirium status, American Society of Anesthesiologists (ASA) grade, length of stay, and mortality were collected. Reoperation and mortality were recorded up to a median follow-up of 29.5 months (interquartile range 12 to 51.4). Cox regression was performed to evaluate independent risk factors associated with reoperation and mortality. Results. The cohort consisted of 1,619 patients with a mean age of 82.2 years (50 to 104), of whom 1,100 (67.9%) were female. In total, 29 patients (1.8%) underwent a reoperation; 12 patients (0.7%) sustained a PFF during the observation period (United Classification System (UCS)-A n = 2; UCS-B n = 5; UCS-C n = 5), of whom ten underwent surgical management. Perioperative delirium was independently associated with the occurrence of PFF (hazard ratio (HR) 5.92; p = 0.013) and surgery for UCS-B PFF (HR 21.7; p = 0.022). Neither all-cause reoperation nor PFF-related surgery was independently associated with mortality (HR 0.66; p = 0.217 and HR 0.38; p = 0.170, respectively). Perioperative delirium, male sex, older age, higher ASA grade, and pre-fracture residential status were independently associated with increased mortality risk following hemiarthroplasty (p < 0.001). Conclusion. The cumulative incidence of PFF at four years was 1.1% in elderly patients following cemented PTS hemiarthroplasty for a hip fracture. Perioperative delirium was independently associated with a PFF. However, reoperation for PPF was not independently associated with patient mortality after adjusting for patient-specific factors. Cite this article: Bone Jt Open 2024;5(4):269–276


Bone & Joint Research
Vol. 9, Issue 5 | Pages 242 - 249
1 May 2020
Bali K Smit K Ibrahim M Poitras S Wilkin G Galmiche R Belzile E Beaulé PE

Aims. The aim of the current study was to assess the reliability of the Ottawa classification for symptomatic acetabular dysplasia. Methods. In all, 134 consecutive hips that underwent periacetabular osteotomy were categorized using a validated software (Hip2Norm) into four categories of normal, lateral/global, anterior, or posterior. A total of 74 cases were selected for reliability analysis, and these included 44 dysplastic and 30 normal hips. A group of six blinded fellowship-trained raters, provided with the classification system, looked at these radiographs at two separate timepoints to classify the hips using standard radiological measurements. Thereafter, a consensus meeting was held where a modified flow diagram was devised, before a third reading by four raters using a separate set of 74 radiographs took place. Results. Intrarater results per surgeon between Time 1 and Time 2 showed substantial to almost perfect agreement among the raters (κappa = 0.416 to 0.873). With respect to inter-rater reliability, at Time 1 and Time 2 there was substantial agreement overall between all surgeons (Time 1 κappa = 0.619; Time 2 κappa = 0.623). Posterior and anterior rating categories had moderate and fair agreement at Time 1 (posterior κappa = 0.557; anterior κappa = 0.438) and Time 2 (posterior κappa = 0.506; anterior κappa = 0.250), respectively. At Time 3, overall reliability (κappa = 0.687) and posterior and anterior reliability (posterior κappa = 0.579; anterior κappa = 0.521) improved from Time 1 and Time 2. Conclusion. The Ottawa classification system provides a reliable way to identify three categories of acetabular dysplasia that are well-aligned with surgical management. The term ‘borderline dysplasia’ should no longer be used. Cite this article: Bone Joint Res. 2020;9(5):242–249


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 124 - 134
1 Feb 2023
Jain S Farook MZ Aslam-Pervez N Amer M Martin DH Unnithan A Middleton R Dunlop DG Scott CEH West R Pandit H

Aims. The aim of this study was to compare open reduction and internal fixation (ORIF) with revision surgery for the surgical management of Unified Classification System (UCS) type B periprosthetic femoral fractures around cemented polished taper-slip femoral components following primary total hip arthroplasty (THA). Methods. Data were collected for patients admitted to five UK centres. The primary outcome measure was the two-year reoperation rate. Secondary outcomes were time to surgery, transfusion requirements, critical care requirements, length of stay, two-year local complication rates, six-month systemic complication rates, and mortality rates. Comparisons were made by the form of treatment (ORIF vs revision) and UCS type (B1 vs B2/B3). Kaplan-Meier survival analysis was performed with two-year reoperation for any reason as the endpoint. Results. A total of 317 periprosthetic fractures (in 317 patients) with a median follow-up of 3.6 years (interquartile range (IQR) 2.0 to 5.4) were included. The fractures were type B1 in 133 (42.0%), B2 in 170 (53.6%), and B3 in 14 patients (4.4%). ORIF was performed in 167 (52.7%) and revision in 150 patients (47.3%). The two-year reoperation rate (15.3% vs 7.2%; p = 0.021), time to surgery (4.0 days (IQR 2.0 to 7.0) vs 2.0 days (IQR 1.0 to 4.0); p < 0.001), transfusion requirements (55 patients (36.7%) vs 42 patients (25.1%); p = 0.026), critical care requirements (36 patients (24.0%) vs seven patients (4.2%); p < 0.001) and two-year local complication rates (26.7% vs 9.0%; p < 0.001) were significantly higher in the revision group. The two-year rate of survival was significantly higher for ORIF (91.9% (standard error (SE) 0.023%) vs 83.9% (SE 0.031%); p = 0.032) compared with revision. For B1 fractures, the two-year reoperation rate was significantly higher for revision compared with ORIF (29.4% vs 6.0%; p = 0.002) but this was similar for B2 and B3 fractures (9.8% vs 13.5%; p = 0.341). The most common indication for reoperation after revision was dislocation (12 patients; 8.0%). Conclusion. Revision surgery has higher reoperation rates, longer surgical waiting times, higher transfusion requirements, and higher critical care requirements than ORIF in the management of periprosthetic fractures around polished taper-slip femoral components after THA. ORIF is a safe option providing anatomical reconstruction is achievable. Cite this article: Bone Joint J 2023;105-B(2):124–134


The Paprosky acetabular bone defect classification system and related algorithms for acetabular reconstruction cannot properly guide cementless acetabular reconstruction in the presence of porous metal augments. We aimed to introduce a rim, points, and column (RPC)-oriented cementless acetabular reconstruction algorithm and its clinical and radiographic outcomes. A total of 123 patients (128 hips) were enrolled. A minimum 5-year radiographic follow-up was available for 96 (75.8%) hips. The mean clinical and radiographic follow-up durations were 6.8±0.9 (range: 5.2–9.2) and 6.3±1.9 (range: 5.0–9.2) years, respectively. Harris hip score (HHS) improved significantly from 35.39±9.91 preoperatively to 85.98±12.81 postoperatively (P<0.001). Among the fixation modes, 42 (32.8%) hips were reconstructed with rim fixation, 42 (32.8%) with three-point fixation without point reconstruction, 40 (31.3%) with three-point fixation combined with point reconstruction, and 4 (3.1%) with three-point fixation combined with pelvic distraction. Complementary medial wall reconstruction was performed in 20 (15.6%) patients. All acetabular components were radiographically stable. Nine-year cumulative Kaplan–Meier survival rates for 123 patients with the endpoint defined as periprosthetic joint infection, any reoperation, and dissatisfaction were 96.91% (confidence interval [CI]: 86.26%, 99.34%), 97.66% (CI: 92.91%, 99.24%), and 96.06% (CI: 86.4%, 98.89%), respectively. Cup stability in cementless acetabular reconstruction depends on rim or three-point fixation. The continuity of the anterior and posterior columns determines whether the points provide adequate stability to the cup. Medial wall reconstruction is an important complementary fixation method for rim or three-point fixation. The patients who underwent cementless acetabular reconstruction guided by the RPC decision-making algorithm demonstrated satisfactory mid-term clinical function, satisfaction levels, radiographic results, and complication rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 6 - 6
7 Jun 2023
Declercq J Vandeputte F Corten K
Full Access

Tenotomy of the iliopsoas tendon has been described as an effective procedure to treat refractive groin pain induced by iliopsoas tendinitis. However, the procedure forces the rectus femoris to act as the primary hip flexor and little is known about the long-term effects of this procedure on the peri-articular muscle envelope (PAME). Studies suggest that iliopsoas tenotomy results in atrophy of the iliopsoas and decreased hip flexion strength with poorer outcomes, increasing the susceptibility for secondary tendinopathy. The aim of this study is to describe changes in the PAME following psoas release. All patients who presented for clinical examination at our hospital between 2016 and 2021 were retrospectively reviewed. Patients who presented after psoas tenotomy with groin pain and who were unable to actively lift the leg against gravity, were included. Pelvic MRI was taken. Qualitative muscle evaluation was done with the Quartile classification system. Quantitative muscle evaluation was done by establishing the cross-sectional area (CSA). Two independent observers evaluated the ipsi- and contralateral PAME twice. The muscles were evaluated on the level: iliacus, psoas, gluteus minimus-medius-maximus, rectus femoris, tensor fasciae lata, piriformis, obturator externus and internus. For the qualitative evaluation, the intra- and inter-observer reliability was calculated by using kappastatistics. A Bland-Altman analysis was used to evaluate the intra- and inter-observer reliability for the quantitative evaluation. The Wilcoxon test was used to evaluate the changes between the ipsi- and contra-lateral side. 17 patients were included in the study. Following psoas tenotomy, CSA reduced in the ipsilateral gluteus maximus, if compared with the contralateral side. Fatty degeneration occurred in the tensor fascia latae. Both CSA reduction and fatty degeneration was seen for psoas, iliacus, gluteus minimus, piriformis, obturator externus and internus. No CSA reduction and fatty degeneration was seen for gluteus medius and rectus femoris. Conclusions/Discussion. Following psoas tenotomy, the PAME of the hip shows atrophy and fatty degeneration. These changes can lead to detrimental functional problems and may be associated with debilitating rectus femoris tendinopathy. In patients with psoas tendinopathy, some caution is advised when considering an iliopsoas tenotomy


Bone & Joint Open
Vol. 2, Issue 7 | Pages 466 - 475
8 Jul 2021
Jain S Lamb J Townsend O Scott CEH Kendrick B Middleton R Jones SA Board T West R Pandit H

Aims. This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type. Results. A total of 584 cases were included. Median age was 79.1 years (interquartile range 72.0 to 86.0), 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The most common AO/OTA type was spiral (352, 60.3%). Metaphyseal split fractures occurred only with PTS stems with an incidence of 10.1%. Male sex was associated with a five-fold reduction in odds of a type C fracture (OR 0.22 (95% CI 0.12 to 0.41); p < 0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51 (95% CI 3.72 to 24.34); p < 0.001) and wedge fracture (OR 3.72 (95% CI 1.16 to 11.95); p = 0.027) compared to PTS stems. Both UCS grade and AO/OTA type differed significantly (p < 0.001 and p = 0.001, respectively) between the revision and fixation groups but a similar proportion of B1 fractures underwent revision compared to fixation (45.3% vs 50.6%). Conclusion. The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems have higher odds of bending type fractures (transverse and wedge) compared to PTS stems. There is considerable variation in practice when treating B1 fractures around cemented stems. Cite this article: Bone Jt Open 2021;2(7):466–475