Advertisement for orthosearch.org.uk
Results 1 - 20 of 426
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1603 - 1609
1 Dec 2013
Chana R Facek M Tilley S Walter WK Zicat B Walter WL

We report the clinical and radiological outcomes of a series of contemporary cementless ceramic-on-ceramic total hip replacements (THRs) at ten years in patients aged ≤ 55 years of age. Pre- and post-operative activity levels are described. A total of 120 consecutive ceramic cementless THRs were performed at a single centre in 110 patients from 1997 to 1999. The mean age of the patients at operation was 45 years (20 to 55). At ten years, four patients had died and six were lost to follow-up, comprising ten hips. The mean post-operative Harris hip score was 94.7 (55 to 100). Radiological analysis was undertaken in 90 available THRs of the surviving 106 hips at final review: all had evidence of stable bony ingrowth, with no cases of osteolysis. Wear was undetectable. There were four revisions. The survival for both components with revision for any cause as an endpoint was 96.5% (95% confidence interval 94.5 to 98.7). The mean modified University of California, Los Angeles activity level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6 to 10) at the ten-year post-operative period. Alumina ceramic-on-ceramic bearings in cementless primary THR in this series have resulted in good clinical and radiological outcomes with undetectable rates of wear and excellent function in the demanding younger patient group at ten years. Cite this article: Bone Joint J 2013;95-B:1603–9


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1434 - 1441
1 Nov 2018
Blakeney WG Beaulieu Y Puliero B Lavigne M Roy A Massé V Vendittoli P

Aims. This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods. Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results. There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion. LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434–41


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1012 - 1019
1 Aug 2017
Howard DP Wall PDH Fernandez MA Parsons H Howard PW

Aims. Ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) are commonly used, but concerns exist regarding ceramic fracture. This study aims to report the risk of revision for fracture of modern CoC bearings and identify factors that might influence this risk, using data from the National Joint Registry (NJR) for England, Wales, Northern Ireland and the Isle of Man. Patients and Methods. We analysed data on 223 362 bearings from 111 681 primary CoC THAs and 182 linked revisions for bearing fracture recorded in the NJR. We used implant codes to identify ceramic bearing composition and generated Kaplan-Meier estimates for implant survivorship. Logistic regression analyses were performed for implant size and patient specific variables to determine any associated risks for revision. Results. A total of 222 852 bearings (99.8%) were CeramTec Biolox products. Revisions for fracture were linked to seven of 79 442 (0.009%) Biolox Delta heads, 38 of 31 982 (0.119%) Biolox Forte heads, 101 of 80 170 (0.126%) Biolox Delta liners and 35 of 31 258 (0.112%) Biolox Forte liners. Regression analysis of implant size revealed smaller heads had significantly higher odds of fracture (chi-squared 68.0, p < 0.001). The highest fracture risk was observed in the 28 mm Biolox Forte subgroup (0.382%). There were no fractures in the 40 mm head group for either ceramic type. Liner thickness was not predictive of fracture (p = 0.67). Body mass index (BMI) was independently associated with revision for both head fractures (odds ratio (OR) 1.09 per unit increase, p = 0.031) and liner fractures (OR 1.06 per unit increase, p = 0.006). . Conclusions. We report the largest independent study of CoC bearing fractures to date. The risk of revision for CoC bearing fracture is very low but previous studies have underestimated this risk. There is good evidence that the latest generation of ceramic has greatly reduced the odds of head fracture but not of liner fracture. Small head size and high patient BMI are associated with an increased risk of ceramic bearing fracture. Cite this article: Bone Joint J 2017;99-B:1012–19


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 741 - 748
1 Jun 2017
Lee YK Ha YC Yoo J Jo WL Kim K Koo KH

Aims

We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship.

Patients and Methods

Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 333 - 338
1 Mar 2013
Jack CM Molloy DO Walter WL Zicat BA Walter WK

The practice of removing a well-fixed cementless femoral component is associated with high morbidity. Ceramic bearing couples are low wearing and their use minimises the risk of subsequent further revision due to the production of wear debris. A total of 165 revision hip replacements were performed, in which a polyethylene-lined acetabular component was revised to a new acetabular component with a ceramic liner, while retaining the well-fixed femoral component. A titanium sleeve was placed over the used femoral trunnion, to which a ceramic head was added. There were 100 alumina and 65 Delta bearing couples inserted.

The mean Harris hip score improved significantly from 71.3 (9.0 to 100.0) pre-operatively to 91.0 (41.0 to 100.0) at a mean follow up of 4.8 years (2.1 to 12.5) (p < 0.001). No patients reported squeaking of the hip.

There were two fractures of the ceramic head, both in alumina bearings. No liners were seen to fracture. No fractures were observed in components made of Delta ceramic. At 8.3 years post-operatively the survival with any cause of failure as the endpoint was 96.6% (95% confidence interval (CI) 85.7 to 99.3) for the acetabular component and 94.0% (95% CI 82.1 to 98.4) for the femoral component.

The technique of revising the acetabular component in the presence of a well-fixed femoral component with a ceramic head placed on a titanium sleeve over the used trunnion is a useful adjunct in revision hip practice. The use of Delta ceramic is recommended.

Cite this article: Bone Joint J 2013;95-B:333–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1017 - 1020
1 Aug 2011
Stafford GH Islam SU Witt JD

Ceramic-on-ceramic bearings in hip replacement have low rates of wear and are increasingly being used in young adults. Our aim was to determine the incidence of audible phenomena or other bearing-related complications. We retrospectively analysed 250 ceramic-on-ceramic hip replacements in 224 patients which had been implanted between April 2000 and December 2007. The mean age of the patients at operation was 44 years (14 to 83) and all the operations were performed using the same surgical technique at a single centre. At a mean follow-up of 59 months (24 to 94), the mean Oxford hip score was 40.89 (11 to 48). There were six revisions, three of which were for impingement-related complications. No patient reported squeaking, but six described grinding or clicking, which was usually associated with deep flexion. No radiological evidence of osteolysis or migration of the components was observed in any hip. The early to mid-term results of contemporary ceramic-on-ceramic hip replacement show promising results with few concerns in terms of noise and squeaking. Positioning of the acetabular component remains critical in regard to the reduction of other impingement-related complications


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 472 - 476
1 Apr 2006
Savarino L Greco M Cenni E Cavasinni L Rotini R Baldini N Giunti A

Modern metal-on-metal bearings produce less wear debris and osteolysis, but have the potential adverse effect of release of ions. Improved ceramic-on-ceramic bearings have the lowest wear of all, but the corrosion process has not been analysed. Our aim was to measure the serum ion release (ng/ml) in 23 patients having stable hip prostheses with a ceramic-on-ceramic coupling (group A) and to compare it with the release in 42 patients with a metal-on-metal bearing (group B) in the medium term. Reference values were obtained from a population of 47 healthy subjects (group C). The concentrations of chromium, cobalt, aluminium and titanium were measured. There was a significant increase of cobalt, chromium and aluminium levels (p < 0.05) in group B compared with groups A and C. Group A did not differ significantly from the control group. Despite the apparent advantage of a metal-on-metal coupling, especially in younger patients with a long life expectancy, a major concern arises regarding the extent and duration of ion exposure. For this reason, the low corrosion level in a ceramic-on-ceramic coupling could be advantageous


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1003 - 1005
1 Aug 2006
Grübl A Weissinger M Brodner W Gleiss A Giurea A Gruber M Pöll G Meisinger V Gottsauner-Wolf F Kotz R

In a randomised study, 28 patients with a mean age of 62.2 years (32 to 81) with osteoarthritis or avascular necrosis of the hip received either a ceramic-on-ceramic or a metal-on-metal total hip replacement. Apart from the liners the acetabular and femoral components were made of Ti-Al-Nb alloy. The serum aluminium and cobalt levels were measured before, and at one year after surgery. The 15 patients in the ceramic-on-ceramic group had a median pre-operative aluminium level of 1.3 μg/l (0.25 to 8.4) and a cobalt level below the detection limit. At one year the aluminium level was 1.1 μg/l (0.25 to 2.3) and the cobalt level was 0.4 μg/l (0.15 to 0.7). The 13 patients in the metal-on-metal group had a median pre-operative aluminium level of 1.9 μg/l (0.25 to 4.4) and a cobalt level below the detection limit. At one year the median aluminium level was 0.9 μg/l (0.25 to 3.9) whereas the cobalt level was 1.4 μg/l (0.5 to 10.5). This increase in the cobalt level at one year was significant (p < 0.001). Our findings indicate that ceramic-on-ceramic bearings do not cause elevated levels of serum aluminium in the first post-operative year


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 65 - 65
19 Aug 2024
Walter W Lin D Weinrauch P de Smet K Beaule P Young D Xu J Manktelow A
Full Access

Hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty. We present the early 2-year clinical and radiographic follow-up of a novel ceramic-on-ceramic (CoC) HRA in an international multi-centric cohort. Patients undergoing HRA between September 2018 and January 2021 were prospectively included. Patient-reported outcome measures (PROMS) in the form of the Forgotten Joint Score (FJS), HOOS Jr, WOMAC, Oxford Hip Score (OHS) and UCLA Activity Score were collected preoperatively and at 1- and 2-years post-operation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis/loosening and heterotopic ossification formation. 200 patients were identified to have reached 2-year follow-up. Of these, 185 completed PROMS follow-up at 2 years. There was significant improvement in HOOS (p< 0.001) and OHS (p< 0.001) and FJS (p< 0.001) between the pre-operative and 2-year outcomes. Patients reported improved pain (p<0.001), function (p<0.001) and reduced stiffness (p<0.001) as measured by the WOMAC score. Patients had improved activity scores on the UCLA Active Score (P<0.001) with 53% reporting return to impact activity at 2 years. There was no osteolysis and the mean acetabular cup inclination angle was 41deg and the femoral component shaft angle was 137deg. No fractures were reported over but there was one sciatic nerve palsy with partial recovery. Two patients were revised; one at 3 months for pain due to a misdiagnosed back problem and another at 33 months for loosening of the acetabular component with delamination of the titanium ingrowth surface. CoC resurfacing at 2-years post-operation demonstrate promising results with satisfactory PROMS


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 106 - 106
10 Feb 2023
Lin D Xu J Weinrauch P Yates P Young D Walter W
Full Access

Hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty. We present the early 1 and 2-year clinical and radiographical follow-up of a novel ceramic-on-ceramic (CoC) HRA in a multi-centric Australian cohort. Patient undergoing HRA between September 2018 and April 2021 were prospectively included. Patient-reported outcome measures (PROMS) in the form of the Forgotten Joint Score (FJS), HOOS Jr, WOMAC, Oxford Hip Score (OHS) and UCLA Activity Score were collected preoperatively and at 1- and 2-years post-operation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis/loosening and heterotopic ossification formation. 209 patients were identified of which 106 reached 2-year follow-up. Of these, 187 completed PROMS at 1 year and 90 at 2 years. There was significant improvement in HOOS (p< 0.001) and OHS (p< 0.001) between the pre-operative, 1-year and 2-years outcomes. Patients also reported improved pain (p<0.001), function (p<0.001) and reduced stiffness (p<0.001) as measured by the WOMAC score. Patients had improved activity scores on the UCLA Active Score (p<0.001) with 53% reporting return to impact activity at 2 years. FJS at 1 and 2-years were not significantly different (p=0.38). There was no migration, osteolysis or loosening of any of the implants. The mean acetabular cup inclination angle was 41.3° and the femoral component shaft angle was 137°. No fractures were reported over the 2-year follow-up with only 1 patient reporting a sciatic nerve palsy. There was early return to impact activities in more than half our patients at 2 years with no early clinical or radiological complications related to the implant. Longer term follow-up with increased patient numbers are required to restore surgeon confidence in HRA and expand the use of this novel product. In conclusion, CoC resurfacing at 2-years post-operation demonstrate promising results with satisfactory outcomes in all recorded PROMS


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 439 - 442
1 Apr 2011
Sexton SA Yeung E Jackson MP Rajaratnam S Martell JM Walter WL Zicat BA Walter WK

We investigated factors that were thought to be associated with an increased incidence of squeaking of ceramic-on-ceramic total hip replacements. Between June 1997 and December 2008 the three senior authors implanted 2406 primary total hip replacements with a ceramic-on-ceramic bearing surface. The mean follow-up was 10.6 years. The diagnosis was primary osteoarthritis in each case, and no patient had undergone previous surgery to the hip. We identified 74 squeaking hips (73 patients) giving an incidence of 3.1% at a mean follow-up of 9.5 years (4.1 to 13.3). Taller, heavier and younger patients were significantly more likely to have hips that squeaked. Squeaking hips had a significantly higher range of post-operative internal (p = 0.001) and external rotation (p = 0.003) compared with silent hips. Patients with squeaking hips had significantly higher activity levels (p = 0.009). A squeaking hip was not associated with a significant difference in patient satisfaction (p = 0.24) or Harris hip score (p = 0.34). Four implant position factors enabled good prediction of squeaking. These were high acetabular component inclination, high femoral offset, lateralisation of the hip centre and either high or low acetabular component anteversion. This is the largest study to date to examine patient factors and implant position factors that predispose to squeaking of a ceramic-on-ceramic hip. The results suggest that factors which increase the mechanical forces across the hip joint and factors which increase the risk of neck-to-rim impingement, and therefore edge-loading, are those that predispose to squeaking


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 41 - 41
19 Aug 2024
Cobb J Maslivec A Clarke S Halewood C Wozencroft R
Full Access

A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls. Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D Motion Capture. Statistical parametric mapping was used for analysis. cHRA improved the median Harris Hip Score from 63 to 100, Oxford Hip score from 27 to 48 and the MET from 5.7 to 10.3. cHRA improved top walking speed (5.75km vs 7.27km/hr), achieved a more symmetrical ground reaction force profile, (Symmetry Index value: 10.6% vs 0.9%) and increased hip range of motion (ROM) (31.7° vs 45.9°). Postoperative data was not statistically distinguishable from the healthy controls in any domain. This gait study sought to document the function of a novel ceramic hip resurfacing, using those features of gait commonly used to describe the shortcomings of hip arthroplasty. These features were captured before and 12 months following surgery. Preoperatively the gait patterns were typical for OA patients, while at 1 year postoperatively, this selected group of patients had gait patterns that were hard to distinguish from healthy controls despite an extended posterior approach. Applications for regulatory approval have been submitted


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1448 - 1453
1 Nov 2009
Sexton SA Walter WL Jackson MP De Steiger R Stanford T

Dislocation is a common reason for revision following total hip replacement. This study investigated the relationship between the bearing surface and the risk of revision due to dislocation. It was based on 110 239 primary total hip replacements with a diagnosis of osteoarthritis collected by the Australian Orthopaedic Association National Joint Replacement Registry between September 1999 and December 2007. A total of 862 (0.78%) were revised because of dislocation. Ceramic-on-ceramic bearing surfaces had a lower risk of requiring revision due to dislocation than did metal-on-polyethylene and ceramic-on-polyethylene surfaces, with a follow-up of up to seven years. However, ceramic-on-ceramic implants were more likely to have larger prosthetic heads and to have been implanted in younger patients. The size of the head of the femoral component and age are known to be independent predictors of dislocation. Therefore, the outcomes were stratified by the size of the head and age. There is a significantly higher rate of revision for dislocation in ceramic-on-ceramic bearing surfaces than in metal-on-polyethylene implants when smaller sizes (≤ 28 mm) of the head were used in younger patients (< 65 years) (hazard ratio = 1.53, p = 0.041) and also with larger (> 28 mm) and in older patients (≥ 65 years) (hazard ratio = 1.73, p = 0.016)


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 95 - 96
1 Mar 2010
Chang J Vegad T Yoo J Lee S
Full Access

Total Hip Arthroplasty (THA) has been more frequently performed for relatively young patients with osteonecrosis of the femoral head in Korea. Moreover, squatting and sitting with crossed legs are more common in Asian cultures than in Western cultures. Wear debris generated by conventional metal-on-PE articulations has been giving rise to extensive osteolysis. Due to these characteristics, higher incidence of pelvic osteolysis was observed after THA in Korea. As a result, interest in alternative bearings such as ceramic-on-ceramic bearing has been increased. Furthermore, the patients who require revision THA are still young in Korea. With this point of view, an application of ceramic-on-ceramic bearing throughout revision THA seems to be reasonable. The clinical and radiographical outcomes after revision THA with use of third generation ceramic-on-ceramic bearing in Korean patients were evaluated. Materials and Methods: We have analyzed 42 hips (37 patients; 17 men and 20 women), in whom revision THAs were performed using cementless cups with ceramic-on-ceramic bearing (Biolox Forte; CeramTec, Plochingen, Germany). They underwent THA at a single institution between February 2000 and December 2004, and were consecutively enrolled in this study. Their mean age was 48.8 years (32 – 59 years), and their mean weight was 61.5 ± 5.8 kg (50 – 72 kg) and BMI was 23.8. The mean interval from primary to revision THA was 9.5 ± 3.2 years (3.3 – 16.1 years). The preoperative diagnoses for primary THA were osteonecrosis of the femoral head in 31 hips, neglected femoral neck fracture in 3, rheumatoid arthritis in 2, degenerative osteoarthritis in 2, pyogenic arthritis in 2, tuberculosis arthritis in 1, and fused hip in 1. Dissociation of PE liner was observed in 21 hips (50%). For acetabular cup revision, Trilogy ceramic acetabular cups (Zimmer, Warsaw, IN) were used in 22 hips, EP-FIT plus cups (Plus Orthopedics, Rotkreuz, Switzerland) in 14 hips, and Duraloc Option Ceramic cups (DePuy, Warsaw, IN) in 6 hips. Stems were revised in all hips. The follow-up protocol included radiographic and clinical evaluations, and the mean duration of follow-up monitoring after revision THA was 5.4 ± 1.7 years (3.2 – 8.0 years). At final follow-up examination, clinical outcomes including Harris Hip Score and complications were assessed. All changes in inclination were documented radiographically. The presence of radiolucent lines, vertical or horizontal migration of acetabular cup (> 2 mm), and osteolysis were also evaluated. Results: At final follow-up evaluation after revision, the average Harris Hip Score was 91.3. There were no revised hips during follow-up period. In 6 hips (14.3%), minor complications were observed: 3 heterotopic ossifications, 2 dislocations, 1 infection. No revision was necessary for the treatment of these complications. There were no hips with radiolucent lines, vertical or horizontal acetabular cup migration or osteolysis during the follow-up period. In 21 hips with bone graft, incorporation of bone graft was observed radiographically at final follow-up examination. Conclusions: Our data showed that clinical and radiographical outcomes after revision THA using third generation ceramic-on-ceramic bearing were favorable. Revision THA with the use of ceramic-on-ceramic bearing surfaces can be preferentially considered especially in young patients. Further studies with long-term follow-up data are warranted


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 877 - 882
1 Jul 2006
Hasegawa M Sudo A Uchida A

A modular layered acetabular component (metal-polyethylene-ceramic) was developed in Japan for use in alumina ceramic-on-ceramic total hip replacement. Between May 1999 and July 2000, we performed 35 alumina ceramic-on-ceramic total hip replacements in 30 consecutive patients, using this layered component and evaluated the clinical and radiological results over a mean follow-up of 5.8 years (5 to 6.5). A total of six hips underwent revision, one for infection, two for dislocation with loosening of the acetabular component, two for alumina liner fractures and one for component dissociation with pelvic osteolysis. There were no fractures of the ceramic heads, and no loosening of the femoral or acetabular component in the unrevised hips was seen at final follow-up. Osteolysis was not observed in any of the unrevised hips. The survivorship analysis at six years after surgery was 83%. The layered acetabular component in our experience, has poor durability because of unexpected mechanical failures including alumina liner fracture and component dissociation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 5 - 5
1 Apr 2018
Pitto R
Full Access

Ceramic-on-ceramic bearings are considered in several European and Asian countries a reliable alternative to metal-on-polyethylene, ceramic-on-polyethylene, or metal-on-metal (with small diameter heads) for total hip arthroplasty (THA) management. Reduced joint wear and limited peri-prosthetic osteolytic changes are the main reasons supporting the use of ceramic. So far, the available observational data show a low rate of revision following the use of Ceramic-on-Ceramic bearings, but concern remains regarding the risk of fracture and the prevalence of squeaking noises from the joint. The objective of this study was to use a national arthroplasty registry to assess whether the choice of bearings – metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), or metal-on-metal (MoM) – is associated with differences in the risk of revision. Data from primary THAs were extracted from the New Zealand Joint Registry over a 15-year period. 97,889 hips were available for analysis. The mean age of patients was 68 years (SD +/− 11 years), and 52% were women. The median followup period in this patient population was 9 years (range, 1 to 15 years). The primary endpoint was revision for any reason. Inclusion criteria were degenerative joint disease (84,894), exclusion criteria were previous surgery, trauma, and any other diagnosis (12,566). We also excluded patients operated on with a Ceramic-on-Metal THA, because of the small recorded number (429). There were 54,409 (64.1%) MoP, 16,503 (19.4%) CoP, 9,051 (10.7%) CoC and 4,931 (5.8%) MoM hip arthroplasties. 3,555 hips were revised during the 15-year observation period. A multivariate assessment was carried out including the following risks factors available for analysis: age, gender, surgeon experience, use of cement. Analysis of bearing surface type and revision showed a statistically significant lower risk for CoC hips (265 THAs, p≤0.01) when compared with CoP (537 THAs, HR 1.07, CI 0,92–1,26), MoP (2186 THAs, HR 1.39, CI 1.19–1,62), and MoM (576 THAs, HR 2.15, CI 1.84–2.51). The 15-year follow-up Kaplan-Meier survival analysis shows a 92% revision-free rate for CoC THAs (Figure 1). In particular, CoC THAs showed the lowest rates of revision for dislocation and for deep infection, when compared with the other bearings. This registry study showed that the bearing surface is associated with the risk of revision. MoM bearing surfaces showed a high rate of revisions, while CoC THAs showed the lowest rate of revision compared to other bearing surfaces. Low wear and less osteolysis are the possible reasons for reduced risk of revision for aseptic loosening. We postulate that the healthy, fibrotic synovial-like pseudocapsule found in CoC THAs preserves the long-term stability of the joint and reduces the bio-burden for late deep infection. Future studies with larger data sets and longer follow-up should continue to investigate this query. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 15 - 15
1 Mar 2010
Colwell CW Hozack WJ Mesko JW D’Antonio JA Bierbaum BE Capello WN Jaffe WL Mai KT
Full Access

Purpose: Dislocation is one of the most common complications following total hip arthroplasty (THA), with rates reported between 1% and 3%, but as high as 6% using a posterior approach with metal on polyethylene bearing surfaces. The purpose of this study was to assess the dislocation rates in ceramic-on-ceramic THAs. Method: Primary ceramic-on-ceramic (Stryker Orthopaedics) THAs performed at 9 institutions from October 1996 through July 2005 were included in the study (1635 hips in 1485 patients). Sixty-one percent were male. The average age was 52 years (range 15–83). Osteoarthritis was the leading reason for surgical intervention (86%). A posterior approach and 32 mm or 36 mm femoral head was used in the majority of patients (90%). Patients returned for routine clinical examination or were contacted by telephone to assess for dislocations at a minimum of one year (average three years) after surgery. Results: Of the 1635 ceramic-on-ceramic THAs performed, there were 18 dislocations (1.1%). Of these, 15 were 32 mm femoral heads; 3 were 28 mm; none were 36 mm. The majority of dislocations occurred within 3 months after surgery (72%). Closed reduction was successful in 17 hips with one requiring a revision. Conclusion: A low rate of dislocations in ceramic-on-ceramic THAs occurred in this study (1.1%). Compared with reported metal-on-polyethylene bearing surfaces, the ceramic-on-ceramic articulation design appears to have fewer dislocations. Other factors associated with this low dislocation rate may be decreased femoral neck diameters and/or larger average femoral head size in patients receiving the ceramic-on-ceramic design. These results will need to be compared with contemporary THA using different articular surfaces


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 735 - 745
1 Jun 2012
Jeffers JRT Walter WL

This systematic review of the literature summarises the clinical experience with ceramic-on-ceramic hip bearings over the past 40 years and discusses the concerns that exist in relation to the bearing combination. Loosening, fracture, liner chipping on insertion, liner canting and dissociation, edge-loading and squeaking have all been reported, and the relationship between these issues and implant design and surgical technique is investigated. New design concepts are introduced and analysed with respect to previous clinical experience


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 144 - 144
1 Jul 2014
Al-Hajjar M Fisher J Hardaker C Kurring G Isaac G Williams S
Full Access

Summary Statement. The frictional torque of ceramic-on-ceramic bearings tended to increase with increasing the bearings size (32, 48, 56mm). However, the frictional torque was significantly lower than that measured on metal-on-metal bearings under well positioned and well lubricated conditions. Introduction. Larger head size in total hip replacement theoretically provides increased range of motion and enhanced stability. However, there are potential clinical concerns regarding increased frictional torques with large diameter metal-on-metal bearings causing loosening of the acetabular cups and corrosion at the taper. The aim of this study was to determine the frictional torques of large diameter BIOLOX® delta ceramic-on-ceramic bearings. Materials and Methods. The single-station pendulum friction simulator (SimSol, UK) was used to determine the frictional torque of three ceramic-on-ceramic bearing sizes: 32mm and 48mm (DeltaMotion®, DePuy Synthes Joint Reconstruction, Leeds, UK) and a 56mm prototype design. Four repeats were tested for each bearing size using 100% new-born calf serum, 25% new-born calf serum and water as lubricants. The input profiles were a simplified loading regime with a peak of 2kN and an angular motion of ±25° [1]. The frictional torque was determined under swing phase loads of 25N, 100N or 300N. The bearings were tested under standard conditions where the cup was positioned so the face was horizontal to the loading axis and at an inclination angle equivalent to 65° in vivo. Results. When lubricated with 100% serum, size 48mm bearings showed similar frictional toque to the 32mm bearings (1.5Nm and 1.7Nm respectively, p=0.28), however, the frictional torque of the 56mm prototype design bearings was significantly higher (2.2Nm, p=0.01). When using 25% serum, there was a trend of increased frictional torque (p=0.016) with increased head size; increasing from 1.2 Nm to 1.5 Nm to 1.9 Nm for the 32mm, 48mm, and 56mm bearings respectively. The frictional torque significantly decreased when water was used compared to using new-born calf serum as lubricant. There was no significant difference in the frictional torque between all bearings sizes with water as lubricant, however, there was a trend of increased frictional torque with increased swing phase load. Changing the swing phase load had no influence on the frictional torques obtained for all bearing sizes when using 100% or 25% new-born calf serum. Under a steep inclination angle, the frictional torque for all bearing sizes did not significantly change compared to the flat cup condition. Discussion and Conclusion. The frictional torque tended to increase with increased head size. The highest frictional torque measured in this study was 2.5Nm for the 56mm ceramic-on-ceramic bearing (25% serum, steep cup) compared to 5.3Nm maximum torque measured using the same method for well-positioned and well lubricated 54mm metal-on-metal bearings. The frictional torque for all ceramic-on-ceramic bearing sizes (32mm, 48mm, and 56mm) decreased as the concentration of protein decreased. This was consistent with previous work done on 28mm bearings and the understanding that for ceramic-on-ceramic bearings the adherence of proteins to the surface reduces the effectiveness of lubricant film thickness, thus resulting in higher frictional torques due to the force required to shear the proteins


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 7 - 7
1 Oct 2020
Webb ML Scanlon CM Kerbel Y Evangelista P Kamath A Nelson CL
Full Access

Introduction. The long-term survival of modern ceramic-ceramic bearings in young active patients with osteonecrosis undergoing total hip arthroplasty (THA) is unknown. A previously published study of this series at 5-year follow-up demonstrated an extremely high activity level. The purpose of this study is to examine whether this very high activity level is associated with ceramic-on-ceramic THA failure at long-term follow-up. Methods. This is a retrospective review of a single-surgeon at an academic medical center between years 2003–2010. Inclusion criteria were consecutive series of ceramic-on-ceramic articulations in patients younger than 50 with a diagnosis of osteonecrosis. Median follow-up was 12.4 years (range 10–17). Data was collected via mail, telephone, and e-mail surveys. Exclusion criteria included deceased prior to follow-up. Preoperative and postoperative Western Ontario and McMaster University Arthritis Index (WOMAC) and University of California at Los Angeles Activity scores (UCLA) were collected. Student t-tests were used as appropriate. Results. There were 108 hips in this series. Median age at THA was 37 (range 14–50). Average preoperative BMI was 27 (range 19–40). The vast majority of patients were highly active at latest follow-up (76% with UCLA scores between 7 and 10). WOMAC scores (1–100 scale) increased from preoperative mean of 41.1 to postoperative 83.8 (p<0.00.1, 98% power, effect size 1). UCLA scores (1–10 scale) improved from a preoperative mean of 3.3 to postoperative 7.2 (p<0.001, 97% power, effect size 1). At 12 years median follow-up, 4 patients had undergone revision surgery. There were no ceramic component failures. One patient underwent early revision for femoral component loosening, one was revised for chronic pain at another institution, one patient was revised for instability at 5 years post-op, and one patient was revised for periprosthetic fracture at 10 years. Conclusion. At long-term follow-up, ceramic bearings accommodate high activity level with excellent component longevity in young patients undergoing THA