Paget's disease of bone (PDB) is characterised by increased bone resorption and development of an erratic bone structure that is highly fragile and susceptible to fracture. In addition, altered joint biomechanics lead to arthritis, more often in the hip and pelvis, resulting in disability and a Total hip Arthroplasty (THA) may be required. THA in PDB is associated with more complications compared to normal population. There is no consensus on the type of arthroplasty that performs better in people with PDB. To our knowledge, there is no meta-analysis in literature on this rare problem.

We undertook a systematic review and meta-analysis to compare the effectiveness of cemented versus cementless THA in patients with PDB. PRISMA guidelines were followed. Search strings were generated based on Boolean operators for identification of the reference articles.

31 studies were included overall. Revision rate was lower in the cementless group compared to the cemented group (chi square=4.36, p=0.04), aseptic loosening was lesser in the cementless group compared to the cemented group (chi square=4.13, p=0.04). The type of the arthroplasty did not affect the infection rate (chi square=2.51, p=0.11), pre and post op Harris Hip Score showed statistically significant difference, but there was no difference between types of arthroplasty

We conclude that THA with uncemented components is better and provided lower revision and aseptic loosening when compared to cemented groups in patients with PDB.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 69 - 69
1 Feb 2017
Kim J Cho H
Full Access

Purpose. We evaluated the clinical and radiographic outcomes of cementless bipolar hemiarthroplasty using rectangular cross-section stem for femoral neck fracture in elderly patients more than 80 years of age with osteoporosis. Material and Methods. 76(cemented 46, cementless 30) bipolar hemiarthroplasties for femur neck fracture were performed in elderly patients more than 80 years old. The mean follow-up period was 4.3 years (2 to 7 years). The Harris hip score at last follow-up and pre-postoperative daily living activity scale according to Kitamura methods were analyzed clinically. The radiological results were assessed using stability of femoral stem and other complications were evaluated. Results: At last follow-up, there were no significant differences of Harris hip score and daily living activity between two groups. Stem loosening and instability were not observed in cementless arthroplasty. There were 18 cases of osseous fixation in radiologic study. There were 1 case of dislocation and 1 case of superficial infection in cemented arthroplasty and 1 case of deep infection in cementless arthroplasty. Conclusion. Cementless bipolar hemiarthroplasty using rectangular cross-section stem for elderly patients with a femoral neck fracture showed satisfactory short-term clinical and radiological results compared to using cement stem


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 36 - 36
1 Dec 2015
Lepetsos P Stylianakis A Leonidou A Argyris D Anastasopoulos P Lelekis M Tsiridis E Macheras G
Full Access

In spite of its incidence decreasing to 1% nowadays, prosthesis-related infections remain a research, diagnostic, therapeutic and cost-related problem. Early diagnosis, selection of an appropriate surgical strategy, accurate identification of the responsible microorganisms and construction of an appropriate antibiotic regimen are essential elements of any management strategy. Our study aim was firstly to compare the diagnostic accuracy of conventional periprosthetic tissue culture and culture of fluid derived from vortexing and bath sonication of the explanted hardware and secondly to investigate the role of possible metabolic factors affecting the sensitivity of the sonication method. We investigated 70 patients undergoing revision hip or knee arthroplasty because of loosening of the prostheses, at our institution, between October 2011 and November 2013. Patients’ medical history and demographic characteristics were recorded. We compared the culture of samples obtained by sonication of explanted hip and knee prostheses with conventional culture of periprosthetic tissue for the microbiological diagnosis of prosthetic-joint infection. Infectious Diseases Society of America (IDSA) Guidelines were used for the definition of prosthetic-joint infection. Thirty-two patients had septic loosening and 38 aseptic loosening (48 hip prostheses and 22 knee prostheses). The sensitivity of sonication fluid culture was 81.25% and the sensitivity of conventional tissue cultures was 56.25% (p-value = 0.043). The sensitivity of the sonication method was statistically higher in obese, diabetic patients, with age above 60, in uncemented arthroplasties and in arthroplasties because of primary osteoarthritis (p-values < 0.05). The sonication method represents a reliable test for the diagnosis of prosthetic – joint infections with a greater sensitivity than the conventional periprosthetic tissue cultures, especially in obese, diabetic patients, with age above 60, in uncemented arthroplasties and in arthroplasties because of primary osteoarthritis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 56 - 56
1 Sep 2012
Geesink R
Full Access

Cementless arthroplasty has progressed substantially in the recent decades from pressfit implantation to porous-coated and later HA-coated implant fixation as its ultimate current state-of-the-art incarnation. As a consequence ever younger and older patients have received the benefits of hip and other arthroplasty although attention to age-related factors is key to success. Key factors for success, from the implant perspective, are adequate primary stability of the device in the bone supported by design and surface structure variables that together with optimal implant biocompatibility result in durable osseo-integration of the device. The high activity levels of younger patients but similarly the generally inferior muscular condition of elderly patients require special attention for the stability of the hip joint with avoidance of impingement. Also bone quality may be a topic for consideration to avoid problems. Excellent survival rates past twenty years are documented in both literature and registries with quantitative studies confirming the excellent implant stability and bone quality. With an optimal consideration for patient related factors as well as anatomic reconstruction of the arthroplasty, modern cementless arthroplasty provides every patient an outlook on both excellent long term functionality and survival


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 35 - 35
1 May 2016
Shin T Kang K Park S Kwon S Lim Y Lim D
Full Access

Introduction. Cementless arthroplasty has been widely used for younger patients with osteoarthritis and other joint pathology. Cementless arthroplasty will be required to porous surface which is to similar to the trabecular bone for bone ingrowth. Titanium Plasma Spray (TPS) has been worldwide used for the porous coating method on arthroplasty. However, TPS coating is limited that would not to establish optimal porosity for bone ingrowth due to arbitary position of melted powder by plasma gas on substrate. Therefore, it is reported coating detached from its substrate (i.e. arthroplasty) is induced implant loosening. Thus, a novel Laser-aided Direct Metal Tooling (DMT) based on Additive Manufacturing (AM) was developed to overcome these limitations. In this study, we were done to assess stereological analysis, static tensile, shear, abrasion test, and physical analysis for evaluation of the efficacy of DMT which was newly-developed coating technology. Then, mechanical characteristics of DMT coating were compared to commercial TPS coating's. Materials and Methods. First, porosity of the DMT coating was evaluated using Microphotography and Scanning Electron Microscopy (SEM), as described in Figure 1. Static tensile and shear test for assessment of mechanical characteristic in relation to the DMT and TPS coating specimens were conducted on the basis of ASTM F1147 and F1044 using universal testing machine (Endolab®, Servohydraulic Test Frame, DE). Maximum tensile strength and maximum shear strength were evaluated for each specimen (n=5). Abrasion test was performed based on ASTM F1978 using Taber® Rotary Platform Abraser Model 5135 (TABER®Industries, USA). Abrasion losses for each specimen (n=6) were measured at 2, 5, 10, and 100 cycles, respectively. Results. Porosity of the DMT coating was found to be 64 ± 11%. Maximum tensile strength (mean ± SD) of the DMT coating (48.6 ± 4.3 MPa) was lower than TPS's (51.5 ± 11.6 MPa) about 5.6%, but detached position of one of the TPS specimens was observed at coating layer not in adhesive layer. Maximum shear strength of the DMT coating (46.3 ± 1.9 MPa) was 10.2% higher, compared to TPS's (42.0 ± 0.6 MPa). Abrasion losses of the DMT (2 cycles, 1.0 ± 0.5 mg; 5 cycles, 2.5 ± 0.9 mg; 10 cycles, 4.2 ± 0.7 mg; 100 cycles, 20 ± 1.4 mg) were significantly higher (71.9% – 77.8% higher) than that of TPS's (2 cycles, 4.5 ± 1.4 mg; 5 cycles, 9.8 ± 2.8 mg; 10 cycles, 17.0 ± 3.4 mg; 100 cycles, 71.1 ± 4.2 mg), as shown in Figure 2. Roughness of the DMT coating was Ra 62.5 ± 2 μm, Rz 316.1 ± 8.1 μm which were 33.5%, 40.6% (Ra, Rz sequence) higher than that of TPS coating (Ra 46.8 ± 8.9 μm, Rz 224.9 ± 28.8 μm), as shown in Figure 3. Conclusions. Our results suggested that a novel DMT coating technology was feasible to apply coating method on the surface of the arthroplasty in terms of outstanding mechanical characteristics which were compared to commercial TPS coating


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 33 - 33
1 Jun 2018
Callaghan J
Full Access

Successful nonarthroplasty solutions for the treatment of osteonecrosis of the femoral head continued to be sought. However, no definitive nonarthroplasty solutions have to date been found. Hence, even in the best of hands a large number of patients with osteonecrosis end up with debilitating end-stage osteoarthritis. In the inception of total hip arthroplasty (THA), the results of treatment of femoral head osteonecrosis by THA were inferior to total hip replacement performed for osteoarthritis. Reasons for this included the young age of many osteonecrosis patients, the high numbers of comorbidities in this population (SLE, sickle cell anemia, alcoholism), and the poor bone quality at the time of surgery. Arthroplasty considerations included bipolar replacement, hemiresurfacing, resurfacing (non metal-on-metal and later metal-on-metal), cemented total hip arthroplasty and cementless total hip arthroplasty. Previous to the use of cementless arthroplasty, all of these procedures had a relatively high 5 to 10 year failure rate of 10–50%. Even our own 10-year results using contemporary cementing techniques demonstrated 10% failure compared to 1–2% failure in our nonosteonecrosis patients. For this reason, it made sense to continue exploring nonarthroplasty solutions for osteonecrosis of the hip. The introduction of cementless fixation for total hip arthroplasty changed the entire thinking about hip osteonecrosis treatment for many of us. Although initially we were concerned about whether bone would grow into the prosthesis in the environment of relatively poor bone, the early results demonstrated that it can and does. Most recently, with the use of crosslinked polyethylene, the cementless construct gives many of us hope that with cementless fixation, the treatment of many patients including the young (especially if followed closely to exchange bearing surfaces if necessary) will last a lifetime with THA being the only and definitive procedure. Our most recent 10-year results demonstrated a femoral stem revision rate of 1.5% will all other stems (other than the stem revised) bone ingrown. Acetabular fixation was also 100% and although 6% required liner exchange, our own and others' results with crosslinked polyethylene would suggest that this problem should be markedly reduced


Aim. To assess the survivorship of a tapered fluted Titanium monoblock stem in conjunction with subtrochanteric shortening for patients with High Dislocation performed at 2 centres. Methods. This was a retrospective study of 84 hips in 52 patients between two centres. All patients had a high dislocation. Thirty five patients had bilateral dysplasia. All patients had total hip arthroplasty with a subtrochanteric shortening osteotomy. The acetabular component was placed at the level of the anatomic hip centre. The femoral component was the “Wagner Cone prosthesis” which is a monoblock Titnium Alloy stem, tapered and fluted. The acetabular component varied. All patients had a follow up examination with a Harris Hip Score and a plain radiograph. The radiographs were assessed for osteotomy complications, change in stem position, evidence of loosening, heterotopic ossification & stress shielding if any. Notes were reviewed for complications. Results. The mean age at operation was 55 yrs (range 20–83). The mean follow up was 9 years (range3–20). Eight patients were lost to follow up (16%). All the rest of the femoral components survived that were available for follow up −84% (worst case scenario). Six patients (7.8%) had an early complication that needed a reoperation. The Mean Harris Hip Score (HHS) improved from 42 points to 88 points. Conclusion. The success rate of patients undergoing Cementless Arthroplasty using the Wagner cone stem in conjunction with a subtrochanteric shortening osteotomy is very high. The complication rate is however larger than in the normal population


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 452 - 452
1 Dec 2013
Lee Y Nho J Lee K Ha Y Koo K
Full Access

Background:. Two-stage reconstruction, reimplantation after removal of an infected prosthesis, has been considered to be the gold standard for treatment of infected hip arthroplasty. However, during the removal of a well-fixed femoral stem, the proximal femur can be damaged and a sequestrum can be formed, which might lead to chronic osteomyelitis and difficulty in reimplantation. We wanted to determine whether infection after hip arthroplasty can be treated without removal of a well-fixed stem. Materials and Methods:. We treated 19 patients who had an infection after hip replacement, but a well-fixed cementless stem, with 2-stage reconstruction. At the first stage, we removed the acetabular cup, the liner and the head, but not the stem. We then implanted a cup of cement spacer. After control of infection, we reimplanted the acetabular component and head. Results:. 2 patients did not undergo second-stage reconstruction because they were satisfied with the pain relief and the activity that they had with the cement-spacer implantation. The remaining 17 patients underwent the second-stage of the reconstruction using cementless arthroplasty. At a mean follow-up time of 4 (2–8) years, 15 of the patients had no recurrence of infection, with satisfactory clinical and radiographic outcome. Discussion:. This second-stage reconstruction after retention of the stem could be an alternative treatment option for periprosthetic infection with a well-fixed stem


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 269 - 272
1 Mar 2002
Conn KS Clarke MT Hallett JP

Templates are used in the preoperative planning of many orthopaedic procedures. The magnification of the bones on preoperative radiographs can vary despite using standardised radiological techniques. Templates will give misleading measurements unless this magnification is quantified. A coin may be used to calculate the magnification, with significant improvement in the accuracy of templating (p = 0.05). A group of patients undergoing uncemented arthroplasty of the hip was at high risk for intraoperative fracture of the femur because the magnification of the radiograph was larger than that of the template


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 1 - 1
1 Jan 2016
Giardina F Guerra G Stea S Bordini B Sudanese A Toni A
Full Access

After a few years from its introduction, the limits of the THA became evident, mainly due to high rates of mobilization for polyethylene wear and to the release of metal ions from MOM and MOP couplings. Ceramic bearings were thus introduced in surgery to obtain lower levels of friction and wear. These issues have now been well recognized by several studies, which show that ceramic-on-ceramic joint has the lowest wear rate among various articulations and that ceramic particles induce less macrophage reaction and decrease cytokine secretion, allowing to have little periprosthetic osteolysis. After the first results in the late 70′s and early 80′s, the mechanical reliability was improved due to the manufacturers' efforts to reduce the ceramic fragility evolving average grain microstructure and lowering the degree of impurity. Betterment and standardization of production have led to 3. rd. generation alumina, Biolox Forte in 1994, that achieved a lower incidence of fracture. The purpose of our study has been to assess long-term follow-up results of alumina-on-alumina 3. rd. generation ceramic total hip cementless arthroplasty performed at our institution from January 1995 to December 2000. We prospectively followed more than 200 patients operated of THA for primary or secondary hip osteoarthritis analyzing clinical and radiographs features. In this period, the total hip replacement were performed by a single surgeon, who is the senior author (A.T.) in our Institution. All patients were clinically examined to confirm the diagnosis and all of them were checked with a standard plain radiographs in two projections and, when necessary, the radiographic examination was completed by CT scans. The same prosthesis was used in all patients, a 3. rd. generation alumina COC articulation, composed of a hemispherical titanium alloy cup and a 28-mm alumina ceramic femoral head. The modular ceramic head was fixed to a 12/14 taper cone. Proximally plasma-spray hydroxyapatite coated Ti alloy stems completes the implant features. Modular necks were used in retro or anteversion and varus or valgus offset, allowing changes in neck-shaft angle and giving a perfect intraoperative stability. Clinical assessment was performed using the Merle-D'Aubigne and Postel hip score. Each patient was assessed before surgery, after 30 days, afterwards at 4 months and annually after surgery. The mode of femoral component fixation was radiographically classified as bone ingrowth fixation, stable fibrous fixation or unstable fixation, according to the criteria Engh-Bobyn. Osteolysis was evaluated on the femoral side at each Gruen zone. Osteolysis on the acetabular side was evaluated by DeLee and Chanley zone. Our study has concluded that cementless modular hip arthroplasty with 3. rd. generation ceramic-on-ceramic bearing, with a 13 to 18 years follow-up, shows an excellent survivorship, in particular for the very low volume release of microparticles during friction, which consequently reduction of cytokine release, thus diminishing the risk of periprosthetic osteolysis and loosening of implant components


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 32 - 32
1 May 2013
Mont M
Full Access

Osteonecrosis is a pathologic bone condition caused by a disruption in the osseous circulation and impairment of normal cellular function which ultimately leads to bone infarction, osteocyte death, and joint degeneration. The incidence of osteonecrosis in the general population has been reported to be approximately 3 per 100,000 people. Up to 20,000 new cases are diagnosed each year and this condition is the indication for surgery in approximately 10% of all total hip arthroplasties performed in the United States. The hip is the most common joint affected, with approximately 75% of cases occurring in this joint, although multifocal osteonecrosis (defined as involvement of more than 3 joints) can also occur. Other commonly observed locations for osteonecrotic lesions include the knee, shoulder, wrist, and ankle. Joint preserving procedures may be performed for early stages without evidence of collapse, while intermediate lesions (e.g. femoral head collapse < 2 mm) may be candidates for joint preserving procedures such as bone grafting and rotational or proximal femoral varus osteotomies. However, total hip arthroplasty is usually required in advanced cases where there are large lesions, deformation of the femoral head, or acetabular involvement. Osteonecrosis has been traditionally associated with poor outcomes following total hip arthroplasty. However, recent studies using newer implant designs and surgical techniques have demonstrated outcomes comparable to the general total hip arthroplasty population. Johansson and colleagues, in a systematic reviewed of the literature, observed a decrease in the revision rate from 17% to 3% for arthroplasties performed later than 1990. The clinical outcomes were also comparable between patients who had osteoarthritis and those who had osteonecrosis. The young age at which these patients often present makes bearing surface choice challenging. Bearings that have low liner wear rates, such as ceramic bearings, had concerns with implant durability following reports of chipping and fracture of the ceramic. However, recent studies evaluating ceramic bearings in young patients with osteonecrosis have demonstrated that newer third and fourth generation ceramics have solved many of these issues. Byun et al. evaluated the clinical outcomes of ceramic bearings in patients younger than 30 years who had osteonecrosis and observed that at six year follow-up, none of the bearings had failed and that 95% of patients were able to continue with their prior occupation. Similar results at even longer follow-up periods were reported by Kim and colleagues who observed no failures in 93 ceramic hips at a mean follow-up of 11 years. Polyethylene wear continues to be a concern for these younger, more active patients. Early studies with non-highly cross linked polyethylene demonstrated high wear rates in these patients. Although newer polyethylene designs have become available which have demonstrated substantially lower wear than the traditional ultra high molecular weight polyethylene cups of the recent past, further studies are needed with these newer polyethylene bearings in the osteonecrosis population. The goal of treatment for femoral head osteonecrosis remains early diagnosis and joint preservation. For patients who present with femoral head collapse or acetabular involvement, total hip arthroplasty often is the only treatment option left. Although clinical outcomes for these patients were initially poor in earlier reports, the advent of modern cementless arthroplasty components, refined surgical techniques, and newer bearing designs have greatly improved the outcomes of this procedure


Bone & Joint 360
Vol. 5, Issue 1 | Pages 12 - 14
1 Feb 2016