Advertisement for orthosearch.org.uk
Results 1 - 20 of 112
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 9 - 9
23 Jun 2023
Lachiewicz PF Skalla LA Purcell KP
Full Access

Severe heterotopic ossification (grade III and IV) after contemporary total hip arthroplasty (THA) requiring excision is very uncommon. We performed a systematic review of the literature, and report a new case series with operative treatment after primary uncemented THA. A systematic review identified papers describing patients who had excision of heterotopic ossification (HO) after contemporary THA, defined as performed after 1988. Concepts of hip arthroplasty, heterotopic ossification, and surgical excision were searched in MEDLINE, Embase, and Scopus, from database inception to November 2022. Inclusion criteria were: articles that included specific patient data on grade of heterotopic ossification, operative procedure, and prophylaxis. Studies were screened for inclusion by two independent reviewers. Extracted data included demographic data, interval from index surgery to excision, clinical results, and complications. One surgeon performed reoperation for ankylosis of primary THA in three patients with severe pain and deformity. Seven case series or case report studies were included. There were 41 patients, with grade III or IV HO, that had excision, and in five patients, revision of a component was also performed. Perioperative prophylaxis was irradiation alone in 10 patients, irradiation and indomethacin in 10, and indomethacin alone in 21 patients. At a mean follow-up time of 14.8 months, definition of the results was not uniform, and range of motion was improved, but relief of pain was inconsistent. There was one dislocation, one gastrointestinal complication, and two recurrences. Treatment of the three patients, with wide excision of peri-articular bone, selective exchange of components, and peri-operative irradiation prophylaxis, was successful in improving motion and deformity. There is insufficient data on the treatment of severe symptomatic HO after contemporary THA. Prophylaxis with low-dose irradiation was successful to prevent recurrence. Multicenter studies will be needed to determine the optimum timing and prognosis for treatment


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 5 - 5
1 Aug 2021
Thompson J Corbett J Bye D Jones A Tissingh E Nolan J
Full Access

The Exeter. ™. V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems. A systematic literature search was performed adhering to PRISMA criteria. In parallel we performed a retrospective single centre study of Exeter. ™. V40 femoral stem prosthetic fractures between April 2003– June 2020. There are 25 reported cases of such prosthetic fractures confined to small case series and case reports within the literature. We report an additional 19 cases to the literature (mean age 66.3 ± 11.7 years; 12 female [63%]; body mass index 32.9 ± 5.9 kg/m. 2. ). The mean time from index procedure to fracture was 7.8 years (2.5–16.3, ±3.6). Exeter V40 stem fracture incidence was 0.27%. Incidence was significantly higher in 125 mm length stems compared to ≥150 mm length stems (1.26% vs 0.13%, respectively, p <0.001) and revision arthroplasty (1.209% vs 0.149%, p <0.001). When comparing different stem length cohorts, 125-mm short-stem were associated with stem body fractures (92% vs 29%, p = 0.0095), earlier time to fracture (6.2 vs 11.0 years, p = 0.0018), younger patient age at time of fracture (62.7 vs 72.6 years old, p = 0.037) and female sex (75% vs 43%, p = 0.33). This case series in conjunction with the systematic review provides evidence stem morphology plays a role in femoral implant fracture. This complication remains rare, although we report a significantly higher incidence at up to 17 years follow-up than in the literature. As femoral geometries remain the same, increasing BMIs in THR patients should raise concern. Short 125 mm length Exeter V40 stems undoubtedly have a role in restoring anatomy and biomechanics in smaller femoral geometries, although the surgeon has to appreciate the higher risk of stem fracture and the associated predisposing factors which may necessitate meticulous surgical technique and planning


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 53 - 53
19 Aug 2024
Hellemondt van GG Colo E Faraj SSA Hooff van M Spruit M
Full Access

The objective of this study was to assess the clinical and radiological results of patients who were revised using a new generation custom-made triflange acetabular component (CTAC) for component loosening and large acetabular defect (Paprosky 3A and 3B) after previous total hip arthroplasty (THA). New generation CTACs involve the use of patient-specific drill guides and incorporate three-dimensional printed bone models, enhancing precision during surgical implantation.

Data were extracted from a single centre prospective database of patients with large acetabular defects who were treated with a new generation CTAC. Patients were included if they had a minimum follow-up of five years. The modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at two- and five-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance (p<0.05).

A total of 49 (70%) of 70 patients with a mean age of 73.5 years (SD 7.7) had a complete follow-up of 5 years. A significant improvement was found in HOOS, mOHS, EQ-5D-3L utility and NRS, VAS pain rest and activity between baseline and final follow-up. Complications included 8 cases with loosening screws, 4 with bony fractures, 4 periprosthetic infections and 2 cases with dislocation. One patient with bilateral pelvic discontinuity had revision surgery due to recurrent dislocations. No revision surgery was performed for screw failure or implant breakage.

New generation CTAC in patients with THA acetabular loosening and massive acetabular bone loss (Paprosky 3A and 3B) can result in stable constructs and significant improvement in functioning and health-related quality of life at five years’ follow-up.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 41 - 41
1 May 2018
Evans J Sayers A Evans J Walker R Blom A Whitehouse M
Full Access

Osteoarthritis of the hip is common and the mainstay of surgical treatment for end-stage disease is total hip replacement. There are few RCTs comparing long-term outcomes between prostheses; therefore, surgeons and patients are reliant on single-centre case-series and recently, analysis of joint registries, when making evidence-based implant choices. We conducted a systematic review, conforming to PRISMA, of Medline and Embase in September 2017. Single-centre case-series and papers analysing registries were included. Series looking at disease-specific cohorts (other than OA), under 15 years follow-up or lacking survival analyses were excluded. Resurfacings, revisions and complex-primaries were also excluded. 2750 abstracts were screened, resulting in 299 full-text articles. Following full review 124 articles were excluded and 21 series added from references, resulting in 150 analyses of individual prostheses/constructs and 12 papers from registries. We also analysed annual reports of registries. Registry data indicated cemented prostheses tended to better outcomes at late follow-ups, whereas case-series showed cementless prostheses tended to have better survival past 15 years with revision for any reason (of stem, cup or either component) as the end-point. The discrepancy between results from registry data and single-centre case series is stark, and whilst the reasons for these differences may be multifactorial, single-centre case-series included in this review often lacked sufficient power to provide precise estimates of survival. This is contrasted to data from registries, which tended to have far greater numbers from multiple centres, allowing results to be generalised to the population. The difference between these two modes of analysis suggests bias exists in selection and outcomes from single-centre series. The varied quality of reporting in case-series make it difficult for a reader to adequately assess bias, and accurately inform contemporary decision making. Surgeons and patients should be cautious when interpreting single-centre case series and systems relying on data generated from them


Bone & Joint Open
Vol. 2, Issue 6 | Pages 443 - 456
28 Jun 2021
Thompson JW Corbett J Bye D Jones A Tissingh EK Nolan J

Aims. The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems. Methods. A systematic literature search was performed adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. In parallel, we performed a retrospective single centre study of Exeter V40 femoral stem prosthetic fractures between April 2003 and June 2020. Results. There are 25 reported cases of such prosthetic fractures confined to small case series and case reports within the literature. We report an additional 19 cases to the literature (mean age 66.3 years (SD 11.7); 12 (63%) females; BMI 32.9 kg/m. 2. (SD 5.9)). The mean time from index procedure to fracture was 7.8 years (SD 3.6; 2.5 to 16.3). Exeter V40 stem fracture incidence was 0.15% and 1.21% for primary and revision arthroplasty, respectively. Incidence was significantly higher in revision arthroplasty (p < 0.001) and 125 mm length stems compared to ≥ 150 mm length stems (1.25% vs 0.13%, respectively; p < 0.001). When comparing different stem length cohorts, 125 mm short-stems were associated with stem-body fractures (92% vs 29%; p = 0.0095), earlier time to fracture (6.2 years vs 11.0 years; p = 0.0018), younger patient age at time of fracture (62.7 years vs 72.6 years; p = 0.037), and female sex (75% vs 43%; p = 0.326). Conclusion. This complication remains rare, although we report a significantly higher incidence at up to 17 years follow-up than in the literature. Short 125 mm length Exeter V40 stems undoubtedly have a role in restoring anatomy and biomechanics in smaller femoral geometries, although the surgeon has to appreciate the higher risk of stem fracture and the associated predisposing factors which may necessitate particular attention to surgical technique and planning. Cite this article: Bone Jt Open 2021;2(6):443–456


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 32 - 32
19 Aug 2024
Caplash G Caplash Y Copson D Thewlis D Ehrlich A Solomon LB Ramasamy B
Full Access

Few surgical techniques to reconstruct the abductor mechanism of the hip have been reported, with outcomes reported only from case reports and small case series from the centres that described the techniques. As in many of our revision THA patients the gluteus maximus was affected by previous repeat posterior approaches, we opted to reconstruct the abductor mechanism using a vastus lateralis to gluteus medius transfer. We report the results of such reconstructions in seven patients, mean age 66 (range, 53–77), five females, presenting with severe abductor deficiency (MRC grade 1–2). Five patients had previous revision THA, two with a proximal femoral replacement, one patient had a primary THA after a failed malunited trochanteric fracture, and one patient had a native hip with idiopathic fatty infiltration of glutei of >90%. All patients had instrumented gait analysis, and surface electromyography (EMG) of the glutei, TFL, and vastus muscles simultaneously before surgery and at each post-op follow-up. Postoperatively, patients were allowed to weight bear as tolerated and were requested to wear an abduction brace for the first six weeks after surgery to protect the transfer. All patients improved after surgery and reached an abductor power of 3 or more. All patients walked without support six months after surgery and were satisfied with the result. Abductor function continued to improve beyond one year of follow-up, and some patients reached an abductor power of 5. EMG demonstrated that the transferred vastus lateralis started firing synchronously with gluteus medius after three months post-surgery, suggesting adaptation to its new function. No knee extension weakness was recorded. One patient complained of lateral thigh numbness and was dissatisfied with the cosmetic look of her thigh after surgery. Our preliminary results are encouraging and comparable with those achieved by the originators of the technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 24 - 24
1 Apr 2022
Partridge T Osborne S Marsh M Holland J
Full Access

We present a consecutive case cohort of the first 100 Birmingham Hip Resurfacing (BHR)'s in 90 patients with a minimum follow up of 20 years. All procedures were performed by a single surgeon having commenced the study in 1998. The original cohort included 68 males with 75 hips (7 bilateral) and 22 females with 25 hips (3 bilateral). The mean age at index procedure was 52. Patients were recalled to review in clinic as per Medicines and Healthcare products Regulatory Agency guidelines with x-rays, metal ions and Harris Hip Scores recorded. After a minimum of 20 year follow-up review the known overall revision rate is 11%. 11 have died and 7 have been lost to review. In males the known revision rate is 4/75 (5%), 3 of which were due to early fractures and 1 revision for infection at 5 years. The known revision rate in females is 7/25 (28%) of which 6 were due to adverse reactions to metal debris; 3 at 7–8 yrs, 1 at 15 yrs, 2 at 18 years, and 1 at 2 months for avascular necrosis. The mean 20 year metal ions results were cobalt 36.6 nmol/l (range 7.4–232.1) and chromium 32.1 nmol/l (range 6–120.8). The mean Harris hip score was 88.5 (range 38.6–99.8). This case series with 20 years follow-up demonstrates excellent long term survival of the BHRs further to registry BHR data and similar to THR for same age recipients. Applying today's strict criteria for patient selection would likely improve survival rate further. BHR has not demonstrated the catastrophic revision rates associated with some metal-on-metal resurfacing and remains a safe option for those who meet the criteria


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 41 - 41
1 Nov 2021
Rudelli S Rudelli M Giglio P Rudelli B
Full Access

Hip instability is one of the most common complications after total hip arthroplasty (THA). Among the possible techniques to treat and prevent hip dislocation, the use of constrained liners is a well-established option. However, there is concern regarding the longevity of these devices due to higher mechanical stress caused by limited hip motion. The primary aim of this paper is to analyze the failure rate of a specific constrained liner in a series of consecutive cases. This study is a retrospective consecutive case series of THA and revision hip arthroplasty (RHA), in which a constrained polyethylene insert was used to treat or prevent hip instability. Patients were divided in 3 different groups (THA for hip fracture, THA for osteoarthrosis, and RHA). Survival analysis was performed for failure, defined as at least one episode of hip dislocation or radiographical signs of acetabular loosening. Logistical regression was used to investigate risk factors for failure. A total of 103 patients were included in the study. Fourteen patients (13,6%) were THA for osteoarthrosis, 60 (58,3%) were THA for hip fracture, and 29(28,2%) were RHA. The median follow-up was 28 months (ranging 12 − 173 months). Failure occurred in 4 cases (3,9%) comprehending 2 dislocations (1,9%) and 2 early acetabular loosening (1,9%). Amongst the groups, there were no cases of failures in the THA due to osteoarthrosis, in the THA for hip fracture there were 3 cases (5%) and in the RHA one case (3,4%). Failure-free survival was not statistically different between groups. There were no risk factors statistically related to failure. The use of constrained acetabular insert to prevent or treat instability achieved an adequate survival time with a low rate of complications. Further studies are necessary to corroborate our findings


Bone & Joint Open
Vol. 2, Issue 5 | Pages 314 - 322
1 May 2021
Alcock H Moppett EA Moppett IK

Aims. Hip fracture is a common condition of the older, frailer person. This population is also at risk from SARS-CoV-2 infection. It is important to understand the impact of coexistent hip fracture and SARS-CoV-2 for informed decision-making at patient and service levels. Methods. We undertook a systematic review and meta-analysis of observational studies of older (> 60 years) people with fragility hip fractures and outcomes with and without SARS-CoV-2 infection during the first wave of the COVID-19 pandemic. The primary outcome was early (30-day or in-hospital) mortality. Secondary outcomes included length of hospital stay and key clinical characteristics known to be associated with outcomes after hip fracture. Results. A total of 14 cohort and five case series studies were included (692 SARS-CoV-2 positive, 2,585 SARS-CoV-2 negative). SARS-CoV-2 infection was associated with an overall risk ratio (RR) for early mortality of 4.42 (95% confidence interval (CI) 3.42 to 5.82). Early mortality was 34% (95% CI 30% to 38%) and 9% (95% CI 8% to 10%) in the infected and noninfected groups respectively. Length of stay was increased in SARS-CoV-2 infected patients (mean difference (MD) 5.2 days (3.2 to 7.2)). Age (MD 1.6 years (0.3 to 2.9)); female sex (RR 0.83 (95% CI 0.65 to 1.05)); admission from home (RR 0.51 (95% CI 0.26 to 1.00)); presence of dementia (RR 1.13 (95% CI 0.94 to 1.43)); and intracapsular fracture (RR 0.89 (95% CI 0.71 to 1.11)) were not associated with SARS-CoV-2 infection. There were statistically, but not clinically, significantly greater Nottingham Hip Fracture Scores in infected compared with non-infected patients (MD 0.7 (0.4 to 0.9)). Conclusion. SARS-CoV-2 infection is associated with worse outcomes after hip fracture. This is not explained by differences in patient characteristics. These data can be used to support informed decision-making and may help track the impact of widespread adoption of system-level and therapeutic changes in management of the COVID-19 pandemic. Cite this article: Bone Jt Open 2021;2(5):314–322


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 40 - 40
1 Aug 2021
Holleyman R Stamp G Board T Bankes M Khanduja V Malviya A
Full Access

Chondral hip injuries are common secondary to femoroacetabular impingement (FAI). Treatment with arthroscopic procedures including chondroplasty and microfracture is becoming increasingly common but literature is limited to case series at specialist centres. The aim of this study is to compare outcomes of arthroscopic acetabular chondral procedures using the NAHR dataset (UK) which represents the largest series to date. All adult Arthroscopies recorded in the NAHR from Jan 2012 were available for inclusion. Exclusions included significant arthritis and femoral, complex or revision chondral procedures. Patients completed iHOT-12 & EQ-5D Index pre-operatively, 6 and 12 months. Data was analysed using T-test/ANOVA for between group/within group for continuous variables, chi square test for categorical variables and linear regression model for multivariable analysis. 5,752 patients, 60% female. 27% Chondroplasty, 5% Microfracture, 68% no Chondral Procedure. Maximum acetabular Outerbridge classification 14% Grade 1, 15% Grade 2, 17% Grade 3, 8% Grade 4, 9% no damage, not recorded in 37%. Higher proportion of Cam impingement in association with chondral treatments and a larger proportion of patients with no impingement recorded in group with no chondral procedures. There was a significant improvement versus baseline for all groups in iHOT-12 and EQ-5D Index (p<0.0001) including Grade four Outerbridge. There was significantly greater improvement in pre-operative scores in the chondroplasty group compared to the microfracture group at 6 and 12 months (p<0.05). Following hip arthroscopy, patients with chondral procedures experienced improved outcome scores despite Outerbridge 4 chondral damage. Presence of cam lesions are more commonly associated with chondral treatments. Good outcomes were maintained up to 12 months for chondral procedures, regardless of age or impingement pathology however pincers improved less and patients over 40 years took longer to see improvement


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 305 - 308
1 Feb 2021
Howell M Rae FJ Khan A Holt G

Aims. Iliopsoas pathology is a relatively uncommon cause of pain following total hip arthroplasty (THA), typically presenting with symptoms of groin pain on active flexion and/or extension of the hip. A variety of conservative and surgical treatment options have been reported. In this retrospective cohort study, we report the incidence of iliopsoas pathology and treatment outcomes. Methods. A retrospective review of 1,000 patients who underwent THA over a five-year period was conducted, to determine the incidence of patients diagnosed with iliopsoas pathology. Outcome following non-surgical and surgical management was assessed. Results. In all, 24 patients were diagnosed as having developed symptomatic iliopsoas pathology giving an incidence of 2.4%. While the mean age for receiving a THA was 65 years, the mean age for developing iliopsoas pathology was 54 years (28 to 67). Younger patients and those receiving THA for conditions other than primary osteoarthritis were at a higher risk of developing this complication. Ultrasound-guided steroid injection/physiotherapy resulted in complete resolution of symptoms in 61% of cases, partial resolution in 13%, and no benefit in 26%. Eight out of 24 patients (who initially responded to injection) subsequently underwent surgical intervention including tenotomy (n = 7) and revision of the acetabular component (n = 1). Conclusion. This is the largest case series to estimate the incidence of iliopsoas pathology to date. There is a higher incidence of this condition in younger patients, possibly due to the differing surgical indications. Arthoplasty for Perthes' disease or developmental dysplasia of the hip (DDH) often results in leg length and horizontal offset being increased. This, in turn, may increase tension on the iliopsoas tendon, possibly resulting in a higher risk of psoas irritation. Image-guided steroid injection is a low-risk, relatively effective treatment. In refractory cases, tendon release may be considered. Patients should be counselled of the risk of persisting groin pain when undergoing THA. Cite this article: Bone Joint J 2021;103-B(2):305–308


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims

Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon.

Methods

A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records.


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims

Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects.

Methods

We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 523 - 531
11 Jul 2023
Passaplan C Hanauer M Gautier L Stetzelberger VM Schwab JM Tannast M Gautier E

Aims

Hyaline cartilage has a low capacity for regeneration. Untreated osteochondral lesions of the femoral head can lead to progressive and symptomatic osteoarthritis of the hip. The purpose of this study is to analyze the clinical and radiological long-term outcome of patients treated with osteochondral autograft transfer. To our knowledge, this study represents a series of osteochondral autograft transfer of the hip with the longest follow-up.

Methods

We retrospectively evaluated 11 hips in 11 patients who underwent osteochondral autograft transfer in our institution between 1996 and 2012. The mean age at the time of surgery was 28.6 years (8 to 45). Outcome measurement included standardized scores and conventional radiographs. Kaplan-Meier survival curve was used to determine the failure of the procedures, with conversion to total hip arthroplasty (THA) defined as the endpoint.


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims

The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface.

Methods

Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 336 - 343
1 Apr 2024
Haertlé M Becker N Windhagen H Ahmad SS

Aims

Periacetabular osteotomy (PAO) is widely recognized as a demanding surgical procedure for acetabular reorientation. Reports about the learning curve have primarily focused on complication rates during the initial learning phase. Therefore, our aim was to assess the PAO learning curve from an analytical perspective by determining the number of PAOs required for the duration of surgery to plateau and the accuracy to improve.

Methods

The study included 118 consecutive PAOs in 106 patients. Of these, 28 were male (23.7%) and 90 were female (76.3%). The primary endpoint was surgical time. Secondary outcome measures included radiological parameters. Cumulative summation analysis was used to determine changes in surgical duration. A multivariate linear regression model was used to identify independent factors influencing surgical time.


Bone & Joint Open
Vol. 5, Issue 10 | Pages 858 - 867
11 Oct 2024
Yamate S Hamai S Konishi T Nakao Y Kawahara S Hara D Motomura G Nakashima Y

Aims

The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy.

Methods

We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 971 - 976
5 Nov 2024
Baker G Hill J O'Neill F McChesney J Stevenson M Beverland D

Aims

In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes.

Methods

A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 53 - 59
19 Jan 2024
Bialaszewski R Gaddis J Laboret B Bergman E Mulligan EP LaCross J Stewart A Wells J

Aims

Social media is a popular resource for patients seeking medical information and sharing experiences. periacetabular osteotomy (PAO) is the gold-standard treatment for symptomatic acetabular dysplasia with good long-term outcomes. However, little is known regarding the perceived outcomes of PAO on social media. The aims of this study were to describe the perceived outcomes following PAO using three social media platforms: Facebook, Instagram, and X (formerly known as Twitter).

Methods

Facebook, Instagram, and X posts were retrospectively collected from 1 February 2023. Facebook posts were collected from the two most populated interest groups: “periacetabular osteotomy” and “PAO Australia.” Instagram and X posts were queried using the most popular hashtags: #PAOwarrior, #periacetabularosteotomy, #periacetabularosteotomyrecovery, #PAOsurgery, and #PAOrecovery. Posts were assessed for demographic data (sex, race, location), perspective (patient, physician, professional organization, industry), timing (preoperative vs postoperative), and perceived outcome (positive, negative, neutral).


Bone & Joint Open
Vol. 4, Issue 2 | Pages 53 - 61
1 Feb 2023
Faraj S de Windt TS van Hooff ML van Hellemondt GG Spruit M

Aims

The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA).

Methods

Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance.