Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 123 - 123
1 Sep 2012
Dhollander A Verdonk P Verdonk R Verbruggen G Almqvist K
Full Access

Aim. The present study was designed to evaluate the implantation of alginate beads containing human mature allogenic chondrocytes for the treatment of symptomatic cartilage defects in the knee. Methods. A biodegradable, alginate-based biocompatible scaffold containing human mature allogenic chondrocytes was used for the treatment of chondral and osteochondral lesions in the knee. Twenty-one patients were clinically prospectively evaluated with use of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and a Visual Analogue Scale (VAS) for pain preoperatively and at 3, 6, 9, 12, 24 and 36 months of follow-up. Results. A statistically significant clinical improvement became apparent after 6 months and patients continued to improve during the 36 months of follow-up. Adverse reactions to the alginate/fibrin matrix seeded with the allogenic cartilage cells were not observed. Two of the procedures failed. One of the patients had loosening of the periosteal flap, which was attributed to a failure of the surgical procedure. The other failure case was the result of the poor quality and quantity of the repair tissue itself. Discussion. The results of this pilot study show that the alginate-based scaffold containing human mature allogenic chondrocytes is feasible for the treatment of symptomatic cartilage defects in the knee. The described technique provides clinical outcomes equal to those of other cartilage repair techniques


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 182 - 182
1 Sep 2012
Martinez Carranza N Nurmi-Sandh H Lagerstedt A Hultenby K Berg H Ryd L
Full Access

Single focal grade IV cartilage lesion in the knee has a poor healing capacity. Instead these lesions often progress to severe and generalized osteoarthritis that may result in total knee replacement. Current treatment modalities aim at biological repair and, although theoretically appealing, the newly formed tissue is at the best cartilage-like, often fibrous or fibrocartilaginous. This at the expense of sophisticated laboratory resources, delicate surgery and strict compliance from patients. An alternative may be small implants of biomaterial inserted to replace the damaged cartilage. We investigated the response of the opposing tibia cartilage to a metallic implant inserted at different depth into the surrounding cartilage level. Methods. The medial femoral condyle of both knees of 12 sheep, 70–90kg, 2 year of age and from the same breeder, was operated. A metallic implant with an articulating surface of 316L stainless steel, diameter of 7mm, HA plasma sprayed press-fit peg and a tailored radius and contour to the sheep femoral condyle was placed at the most weight-bearing position. The level of the implant was aimed flush, 0,3 and 0,8 mm below surrounding cartilage. The animals were stabled indoors, allowed to move freely and euthanized after 6 and 12 weeks. Postoperatively the knees were high resolution photographed for macroscopic evaluation. The position and depth of the implant were analysed using a laser scan device. Tibial and femoral condyles specimen were decalcified and slices were prepared for microscopic evaluation. Implant position and cartilage damage was assessed from two independent observers using a macroscopic ICRS score and a modified histologic score according to Mankin. Results. 22 tibia condyles showed a variety of cartilage damage ranging from severe damage down to subchondral bone to an almost pristine condition. There was a strong correlation between implant position and damage to opposing cartilage surface. Mankin score correlated significantly with implant position (p<0.001 regression analysis, r. 2. =.45) as did the ICRS score (p<0.001, regression analysis, r. 2. =.67). Implants sitting proud were associated with poor Mankin score. There was no difference between 6-week and 3-months knees. Conclusion. By precise postoperative measurement we have shown that significant imprecision occur; this has never before been studied. We found a distinct correlation between implant position and cartilage damage. These results suggest that further studies of metallic implants, inserted into cartilage defects with the utmost precision regarding the surrounding cartilage, may be warranted


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 86 - 86
1 Sep 2012
Negrin L Vécsei V
Full Access

Objective. To provide a best estimate of the average treatment effect when microfracture was chosen as the intervention of choice in patients with full-thickness cartilage defects of the knee. Design. We focussed on controlled studies which either referred to microfracture alone or in comparison with any other surgical treatment of articular cartilage of the knee. Papers including patients who had been treated by microfracture and concomitant adjuvant procedures like ACL reconstruction or meniscus repair were accepted too, whereas papers reporting on the microfracture technique combined with the implantation of a scaffold were excluded. To achieve a best estimate of the average, to be expected treatment effect we pooled pooled before–after data of study arms using microfracture. Because cartilage studies employ various scales to measure functional improvements, we standardized treatment effects using Hedges' g. To provide clinically meaningful estimates we converted the pooled summary effect back into the respective scales by multiplying the pooled effect with pooled standard deviations of each included clinical scale. Results. A systematic review of the literature revealed six papers including 200 patients with a mean age of 32 years, a mean defect size of 3 cm. 2. and a follow up period from 2 to 5 years. Four of the studies compared microfracture to autologous chondrocyte implantation and two of them to osteochondral autologous transplantation. All patients were treated by the microfracture technique as described by Steadman and by a similar rehabilitation protocol which only allowed crutch-assisted touchdown weight bearing initially. Referring to the individual studies, a comparison of the pooled estimates of Hedges' g revealed that the two papers which evaluated the youngest patients provided the highest treatment effect. On the contrary, those two papers which focussed on the largest lesions, reported the worst improvement. Finally, the remaining two papers whose patients were characterized by similar age and defect size presented comparable results. The individual standardized effect sizes were combined into an overall best estimate. Its value was 1.678, measured in units of standard deviation, with the 95% confidence interval of [1.016; 2.340] resulting in different values of the average, to be expected treatment effect when it is measured in Lysholm Score (22.1), IKDC Score (26.5) and KOOS (15.2) points. Conclusions. Our results offer a clinically intuitive estimation of the average treatment effects on common clinical scales. Compared to the preoperative situation, a significant clinical improvement can be expected for each patient. Nevertheless, the magnitudes of these treatment effects are an approximation and must be interpreted cautiously. Furthermore, we did not succeed to confirm that young age and small lesion size have a beneficial effect on the clinical outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 842 - 852
1 Jun 2010
Tannast M Krüger A Mack PW Powell JN Hosalkar HS Siebenrock KA

Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9).

Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports.

Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 778 - 785
1 Jun 2008
Varitimidis SE Basdekis GK Dailiana ZH Hantes ME Bargiotas K Malizos K

In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant.

Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome.