Advertisement for orthosearch.org.uk
Results 1 - 20 of 20
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 44 - 44
1 Dec 2021
Pettit M Doran C Singh Y Saito M Kumar KHS Khanduja V
Full Access

Abstract. Objective. A higher prevalence of cam morphology has been reported in the athletic population but the development of the cam morphology is not fully understood. The purpose of this systematic review is to establish the timing of development of the cam morphology in athletes, the proximal femoral morphologies associated with its development, and other associated factors. Methods. Embase, MEDLINE and the Cochrane Library were searched for articles related to development of the cam morphology, and PRISMA guidelines were followed. Data was pooled using random effects meta-analysis. Study quality was assessed using the Downs and Black criteria and evidence quality using the GRADE framework. Results. This search identified 16 articles involving 2,028 participants. In males, alpha angle was higher in athletes with closed physes than open physes (SMD 0.71; 95% CI 0.23, 1.19). Prevalence of cam morphology was associated with age during adolescence when measured per hip (β 0.055; 95% CI 0.020, 0.091) and per individual (β 0.049; 95% CI 0.034, 0.064). Lateral extension of the epiphysis was associated with an increased alpha angle (r 0.68; 95% CI 0.63, 0.73). A dose-response relationship was frequently reported between sporting frequency and cam morphology. There was a paucity of data regarding the development of cam morphology in females. Conclusions. Very low and low quality evidence suggests that in the majority of adolescent male athletes’ osseous cam morphology developed during skeletal immaturity, and that prevalence increases with age. Very low quality evidence suggests that osseous cam morphology development was related to lateral extension of the proximal femoral epiphysis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 35 - 35
17 Apr 2023
Afzal T Jones A Williams S
Full Access

Cam-type femoroacetabular impingement is caused by bone excess on the femoral neck abutting the acetabular rim. This can cause cartilage and labral damage due to increased contact pressure as the cam moves into the acetabulum. However, the damage mechanism and the influence of individual mechanical factors (such as sliding distance) are poorly understood. The aim of this study was to identify the cam sliding distance during impingement for different activities in the hip joint. Motion data for 12 different motion activities from 18 subjects, were applied to a hip shape model (selected as most likely to cause damage, anteriorly positioned with a maximum alpha angle of 80°). The model comprised of a pointwise representation of the acetabular rim and points on the femoral head and neck where the shape deviated from a sphere (software:Matlab). The movement of each femoral point was tracked in 3D while an activity motion was applied, and impingement recorded when overlap between a cam point and the acetabular rim occurred. Sliding distance was recorded during impingement for each relevant femoral point. Angular sliding distances varied for different activities. The highest mean (±SD) sliding distance was for leg-crossing (42.62±17.96mm) and lowest the trailing hip in golf swing (2.17±1.11mm). The high standard deviation in the leg crossing sliding distances, indicates subjects may perform this activity in a different manner. This study quantified sliding distance during cam impingement for different activities. This is an important parameter for determining how much the hip moves during activities that may cause damage and will provide information for future experimental studies


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 1 - 1
2 Jan 2024
Fiordalisi M Ferreira J Pinto M Ribeiro-Machado C Pinto M Oliveira M Barbosa M Gonçalves R Caldeira J
Full Access

Intervertebral disc (IVD) degeneration occurs with aging, leading to low back pain (LBP), which is one of the leading conditions of disability worldwide. With the lack of effective treatment, decellularized extracellular matrix (dECM) – based biomaterials have been proposed for IVD regeneration. However, the impact of donor ages on tissue repair had never been explored before in the disc field. Therefore, we aimed to address this question. For that, a decellularization protocol for bovine nucleus pulposus (NP) of different aged donors (fetus, young and old) was optimized by testing several detergents (SDS and Triton). The process efficiency was evaluated in terms of DNA and cell removal, as well as ECM preservation. Afterwards, dECMs were repopulated with bovine NP cells and cultured ex vivo. At day 7, cell behavior, ECM de novo synthesis and remodeling were evaluated [1]. Moreover, dECMs’ inflammatory response was assessed after in vivo CAM assay. Finally, inflammatory and angiogenic cytokines were analyzed in the conditioned media-derived from dECMs by using a cytokine array. As results, an optimal decellularization protocol (SDS 0.1%, 1h), efficient at removing cells and DNA from bovine NPs, while preserving ECM cues of native tissues, was developed. After repopulation, aggrecan increased in younger NPs, while collagen 2 decreased which may be indicative of matrix remodeling [1]. After in vivo CAM assay, fetal dECMs showed the highest inflammatory response. Finally, no statistically significant changes of cytokines were detected in the matrices, despite for a trend of higher IFN-α, IFN-γ and LIF in fetal dECMs, IL-1β in young dECMs and Decorin in old dECMs. Overall, this work uncovered the importance of tissue donor ages for tissue regenerative purpose, opening new avenues for the development of appropriate therapeutic strategies for IVD degeneration. Acknowledgments: FCT, EUROSPINE, ON Foundation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 49 - 49
1 Nov 2018
Ng KCG
Full Access

Several previous pathoanatomical and biomechanical studies focused primarily on the cam morphology as the primary contributor to symptoms of femoroacetabular impingement (FAI) and limited range of motion. However, there is a growing population of individuals with asymptomatic cam morphologies who show no clinical signs; thus, the cam deformity, alone, may not fully delineate an individual's symptomatology or limited motion. These studies expanded beyond the cam morphology, to determine how additional anatomical characteristics could contribute to symptoms and influence functional mobility, using: 1) in vivo analyses, where we asked how specific anatomical parameters (in addition to the cam morphology) can predict individuals at risk of symptoms; 2) In silico simulations, where we examined how pathoanatomical features contributed to adverse loading conditions, resulting in higher risks of hip joint degeneration; 3) In vitro cadaveric experiments, where we examined the contributions of the cam morphology and encapsulating ligaments to joint mechanics and microinstability. This research further highlights that more emphasis should be placed on proper patient selection. There are implications of how structural anatomy can affect musculature, joint loading and stability, which should all be closely examined to improve the effectiveness of hip preservation surgery as well as the understanding of non-surgical management


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 26 - 26
1 Nov 2018
Oishi T Kobayashi N Inaba Y Kobayashi D Higashihira S Saito T
Full Access

The pathology of the posterior acetabular legion in femoroacetabular impingement (FAI) syndrome, so called “contre-coup region”, is still unclear. . 18. F-fluoride positron emission tomography (PET) is a functional imaging modality, which reflects the osteoblast activity. Recent technological advances in PET combined with computed tomography (CT) imaging allowed us to obtain detailed 3-dimensional (3D) morphological information. We evaluated the abnormal uptake of . 18. F-fluoride PET/CT on posterior acetabular lesion in FAI syndrome cases. We enrolled forty-one hips from 41 patients who were diagnosed as FAI syndrome and were performed . 18. F-fluoride PET/CT between October 2014 and October 2016. In each hip, the maximum standardized uptake value (SUV. max. ) on the posterior acetabular was measured. The cases were divided into 4 groups; cam-type (11 cases), pincer-type (7), combined-type (11), dysplastic developmental hip (DDH) with cam morphology (12). The average SUV. max. of the pincer-type was significantly smaller than that of the other 3 groups (p < .05). The percentage of the cases with SUV. max. ≥ 6 was 81.8% in cam-type, 28.6% in pincer-type, 90.9% in combined-type, 91.7% in DDH with cam morphology. Furthermore, the average degree of α angle of the cases of SUV. max. ≥ 6 was significantly higher than that of the cases of SUV. max. < 6 (p = .005). Although actual biomechanical mechanism in contre-coup region is still controversial, this result indicated that the cam morphology related to the posterior acetabular lesion with accelerated bone metabolism


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 46 - 46
1 Dec 2021
Yarwood W Kumar KHS Ng KCG Khanduja V
Full Access

Abstract. Purpose. The aim of this study was to assess how biomechanical gait parameters (kinematics, kinetics, and muscle force estimations) differ between patients with camtype FAI and healthy controls, through a systematic search. Methods. A systematic review of the literature from PubMed, Scopus, and Medline and EMBASE via OVID SP was undertaken from inception to April 2020 using PRISMA guidelines. Studies that described kinematics, kinetics, and/or estimated muscle forces in cam-type FAI were identified and reviewed. Results. The search strategy identified 404 articles for evaluation. Removal of duplicates and screening of titles and abstracts resulted in full-text review of 37 articles with 12 meeting inclusion criteria. The 12 studies reported biomechanical data on a total of 173 cam-FAI (151 cam specific, 22 mixed type) patients and 177 healthy age, sex and BMI matched controls. Cam FAI patients had reduced hip sagittal plane ROM (Mean difference −3.00 0 [−4.10, −1.90], p<0.001), reduced hip peak extension angles (Mean Difference −2.05 0[−3.58, −0.53], p=0.008), reduced abduction angles in the terminal phase of stance, and reduced iliacus and psoas muscle force production in the terminal phase of stance compared to the control groups. Cam FAI cohorts walked at a slower speed compared to controls. Conclusions. In conclusion, patients with cam-type FAI exhibit altered sagittal and frontal plane kinematics as well as altered muscle force production during level gait compared to controls. These findings will help guide future research into gait alterations in FAI and how such alterations may contribute to pathological progression and furthermore, how such alterations can be modified for therapeutic benefit


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 75 - 75
1 Nov 2021
Ramos A Matos M
Full Access

Introduction and Objective. The patients with a total hip arthroplasty is growing in world manly in Europe and USA, and this solution present a high success at 10years in several orthopaedic registers. The application of total press-fit hip fixation presents the most used solution, but presents some failures associated to the acetabular component fixation, associated to the load transfer and bone loss at long term. The aim of this work is to investigate the influence of different acetabular bone loss in the strain distribution in iliac bone. To evaluate implant fixation, an experimental study was performed using acetabular press-fit component simulating different acetabular bone loss and measuring the strain distribution. Materials and Methods. The experimental samples developed was based in an iliac bone model of Sawbones supplier and a acetabular component Titanium (Stryker) in a condition press-fit fixation and was implanted according surgical procedure with 45º inclination angle and 20º in the anteversion angle. Were developed five models with same initial bone, one with intact condition simulating the cartilage between bones and four with different bone loss around the acetabular component. These four models representing the evolution of bone support of acetabular components presented in the literature. The evolution of bone loss was imposed with a CAD CAM process in same iliac bone model. The models were instrumented with 5 rosettes in critical region at the cortical bone to measure the strain evolution along the process. Results. The results of strain gauges present the influence of acetabular component implantation, reducing the bone strains and presented the effect of the strain shielding. The acetabular component works as a shield in the load transfer. The critical region is the posterior region with highest principal strains and the strain effect was observed with different bone loss around acetabular component. The maximum value of principal strain was observed in the intact condition in the anterior region, with 950μ∊. In the posterior superior region, the effect of bone loss is more important presenting a reduction of 500% in the strains. The effect of bone loss is presented in the strains induced with acetabular implantation, in the first step of implantation the maximum strain was 950μ∊ and in the last model the value was 50μ∊, indicating lower press-fit fixation. Conclusions. The models developed allows study the effect of bone loss and acetabular implant fixation in the load transfer at the hip articulation. The results presented a critical region as the anterior-superior and the effect of strain shielding was observed in comparison with intact articulation. The results of press-fit fixation present a reduction of implant stability along bone loss. The process of bone fixation developed present some limitation associated to the bone adhesion in the interface, not considered. Acknowledgement. This work was supported by POCI-01-0145-FEDER-032486,– FCT, by the FEDER, with COMPETE2020 - (POCI), FCT/M


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 1012 - 1018
1 Jul 2005
Beck M Kalhor M Leunig M Ganz R

Recently, femoroacetabular impingement has been recognised as a cause of early osteoarthritis. There are two mechanisms of impingement: 1) cam impingement caused by a non-spherical head and 2) pincer impingement caused by excessive acetabular cover. We hypothesised that both mechanisms result in different patterns of articular damage. Of 302 analysed hips only 26 had an isolated cam and 16 an isolated pincer impingement. Cam impingement caused damage to the anterosuperior acetabular cartilage with separation between the labrum and cartilage. During flexion, the cartilage was sheared off the bone by the non-spherical femoral head while the labrum remained untouched. In pincer impingement, the cartilage damage was located circumferentially and included only a narrow strip. During movement the labrum is crushed between the acetabular rim and the femoral neck causing degeneration and ossification. Both cam and pincer impingement lead to osteoarthritis of the hip. Labral damage indicates ongoing impingement and rarely occurs alone


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 71 - 71
1 Mar 2021
Buddhdev P Vallim F Slattery D Balakumar J
Full Access

Abstract. Objective. To assess the prevalence of acetabular retroversion in patients presenting with Slipped Upper Femoral Epiphysis using both validated radiological signs and CT-angle measurements. Methods. A retrospective review of all cases involving surgical management for acute SUFE presenting to the Royal Children's Hospital, Melbourne were assessed from 2012–2018. Pre-operative plain radiographs were assessed for slip angle, validated radiological signs of retroversion (post wall/crossover/ischial spine sign) and standardised post-operative CT Scans were used to assess cranial and mid-acetabular version. Results. 116 SUFEs presented in 107 patients who underwent surgical intervention; 47 females and 60 boys, with an average age of 12.7 years (range 7.5–16.6 years). Complete radiological data was available for 91 patients (99 hips) with adequate axial CT imaging of both hips. 82% patients underwent pinning in situ (PIS) with subcapital realignment surgery (SRS) performed in 18% (slip angles >75°). Contralateral prophylactic hip PIS was performed in 72 patients (87%). On the slip side, 68% of patients had 1 or more radiological signs of retroversion in the slipped hip, with 60% on the contralateral side. The mean cranial and mid-acetabular version measurements were −8°(range −30 – 8°) and 10.5°(range −10 – 25°), respectively. Conclusions. Acetabular retroversion is rare in the normal population with studies reports ranging from 0–7%. This study showed an increased prevalence of 68% in SUFE patients, which is likely to be a primary anatomical abnormality, subsequently increasing the shear forces across the proximal femoral growth plate due to superior over-coverage. The resulting CAM lesion from SUFE in combination with the pincer lesion due to retroversion can lead to premature hip impingement and degeneration. Further larger studies are required to assess if acetabular retroversion is a true risk factor, and its role in helping guide management including prophylactic pinning. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 18 - 18
1 Mar 2021
Ng G Bankes M Grammatopoulos G Jeffers J Cobb J
Full Access

Abstract. OBJECTIVES. Cam femoroacetabular impingement (FAI – femoral head-neck deformity) and developmental dysplasia of the hip (DDH – insufficient acetabular coverage) constitute a large portion of adverse hip loading and early degeneration. Spinopelvic anatomy may play a role in hip stability thus we examined which anatomical relationships can best predict range of motion (ROM). METHODS. Twenty-four cadaveric hips with cam FAI or DDH (12:12) were CT imaged and measured for multiple femoral (alpha angles, head-neck offset, neck angles, version), acetabular (centre-edge angle, inclination, version), and spinopelvic features (pelvic incidence). The hips were denuded to the capsule and mounted onto a robotic tester. The robot positioned each hip in multiple flexion angles (Extension, Neutral 0°, Flexion 30°, Flexion 60°, Flexion 90°); and performed internal-external rotations to 5 Nm in each position. Independent t-tests compared the anatomical parameters and ROM between FAI and DDH (CI = 95%). Multiple linear regressions determined which anatomical parameters could predict ROM. RESULTS. The FAI group demonstrated restricted ROM in deep hip flexion, with DDH showing higher ROM in Flexion 30° (+20%, p = 0.03), 60° (+31%, p = 0.001), and 90° (+36%, p = 0.001). In Neutral 0° and Flexion 30°, femoral neck and version angles together predicted ROM (R. 2. = 60%, 58% respectively); whereas in Flexion 60°, pelvic incidence and femoral neck angle predicted ROM (R. 2. = 77%). In Flexion 90°, pelvic incidence and radial alpha angle together predicted ROM (R. 2. = 81%), where pelvic incidence alone accounted for 63% of this variance. CONCLUSIONS. Pelvic incidence is essential to predict hip ROM. Although a cam deformity or acetabular undercoverage can elevate risks of labral tears and progressive joint degeneration, they may not be primary indicators of restrictive hip impingement or dysplastic instability. Better delineating additional spinopelvic characteristics can formulate early diagnostic tools and improve opportunities for nonsurgical management. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 82 - 82
1 Apr 2017
Palmer J Palmer A Jones L Jackson W Glyn-Jones S Price A
Full Access

Background. Since 2011, the knee service at the Nuffield Orthopaedic Centre has been offering a neutralising medial opening wedge high tibial osteotomy (HTO) to a group of patients presenting with early medial osteoarthritis of the knee, varus alignment and symptoms for more than 2 years. During development of this practice an association was observed between this phenotype of osteoarthritis and the presence of CAM deformity at the hip. Methods. A retrospective cohort study. All patients who underwent HTO since 2011 were identified (n=30). Comparator groups were used in order to establish whether meaningful observations were being made: Control group: The spouses of a high-risk osteoarthritis cohort recruited for a different study at our unit (n=20) Pre-arthroplasty group: Patients who have undergone uni-compartmental arthroplasty (UKA) for antero-medial osteoarthritis (n=20)All patients had standing bilateral full-length radiographs available for analysis using in house developed Matlab-based software for hip measurements and MediCAD for lower limb alignment measurements. Results. A total of 140 limbs from 70 gender-matched subjects were studied. The HTO group had a significantly higher prevalence of CAM lesions defined by an Alpha angle >650. They also had a significantly greater mean alpha angle than both the pre-arthroplasty and control groups [HTO (Avg. 68.3 (±16.1)) vs Pre-arthroplasty (Avg. 59.5 (±15.5)) P=0.01; HTO vs Control (Avg. 58.2 (±13.9)) P=0.007]. Conclusions. The results of this study confirm that our HTO group have a significantly greater prevalence of CAM lesions. A feature not seen in either pre-arthroplasty or control subjects. This group demonstrate independent predictors for progression of OA in both the hip and the knee. To our knowledge this is a novel observation. Level of evidence. Observational cohort study (III)


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 613 - 618
1 May 2004
Orhan Z Ozturan K Guven A Cam K

The effects of extracorporeal shock waves (ESWT) on tendon healing were assessed by observing histological and biomechanical parameters in a rat model of injury to the tendo Achillis. The injury was created by inserting an 18-G needle through tendo Achillis in 48 adult Wistar albino rats. The animals were divided into three groups. The first group received radiation only after the operation. The second received no shock waves and the third had 500 15 KV shocks on the second post-operative day. All the rats were killed on the 21st day after surgery.

Histopathological analysis showed an increase in the number of capillaries and less formation of adhesions in the study group compared with the control group (p = 0.03). A significantly greater force was required to rupture the tendon in the study group (p = 0.028). Our findings suggest a basis for clinical trials using ESWT.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 22 - 22
1 Nov 2018
Inaba Y
Full Access

Biomechanical analysis is important to evaluate the effect of orthopaedic surgeries. CT-image based finite element method (CT-FEM) is one of the most important techniques in the computational biomechanics field. We have been applied CT-FEM to evaluate resorptive bone remodeling, secondary to stress shielding, after total hip arthroplasty (THA). We compared the equivalent stress and strain energy density to postoperative BMD (bone mineral density) change in the femur after THA, and a significant correlation was observed between the rate of changes in BMD after THA and equivalent stress. For periacetabular osteotomy cases, we investigated mechanical stress in the hip joint before and after surgery. Mechanical stress in the hip joint decreased significantly after osteotomy and correlated with the degree of the acetabular coverage. For arthroscopic osteochondroplasty cases, we examined mechanical strength of the proximal femur after cam resection using CT-FEM. The results suggested that both the depth and area of the resection at the distal part of femoral head-neck junction correlated strongly with fracture risk after osteochondroplasty. This talk consists of our results of clinical application studies using CT-FEM, and importance of application of CT-FEM to biomechanical studies to assess the effect of orthopaedic surgeries


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 50 - 50
1 Jan 2017
Petretta M Cavallo C Acciaioli A Mecca R Baleani M Baruffaldi F Lisignoli G Mariani E Grigolo B
Full Access

In clinical orthopedics suitable materials that induce and restore biological functions together with the right mechanical properties are particularly needed for the regeneration of musculoskeletal tissue. An innovative solution to answer this need is represented by tissue engineering. This technique could overcome the limits of traditional approaches involving the use of homologous, autologous or allogenetic tissue (e.g. tissue availability, immune rejection and pathogen transfer). In this field, rapid prototyping techniques are emerging as the most promising tool to realize three-dimensional tissue constructs with highly complex geometries. Based on CAD/CAM technology, rapid prototyping allows development of patient-specific 3D scaffolds from digital data obtained with latest generation imaging tools. These structures can be realized in different materials, tailoring their mechanical properties and architectural features. Most rapid prototyping techniques allow the creation of acellular 3D scaffolds, which must be subsequently seeded with cells. Conversely, 3D bioprinting can deposit bio-ink containing molecules/cells, providing desired spatial distribution of growth factors/cells within the scaffold. The need of printable materials suitable for processing with inkjet, dispensing, or laser-print technologies, forces the use of matrices within a specific range of viscosity. However, these materials have low mechanical features. To overcome this problem and to obtain a final construct with good mechanical properties, bioprinting tissue fabrication can rely on the alternate deposition of thermoplastic materials and cell-laden hydrogels. Since mechanical performance is determined not only by the material properties but also by the geometry (microarchitecture) of the structure, printing parameters can be modified to obtain the desired features. The new 3D platform available at Rizzoli Orthopaedic Institute, consisting of a Computer Tomography (GE Medical Systems, Milano, Italia) and a 3D Bio-Printer (RegenHU, Villaz-St-Pierre, Switzerland) is used to address the above-mentioned issues. Preliminary results showed that it is possible to modify the microarchitecture of the printed structures adjusting their apparent density and stiffness in the range of the trabecular bone tissue. Additionally, it has been proven that the calcium phosphate based paste, used as bioink, allows cell attachment and proliferation. Therefore, the platform allows to print scaffolds with open and interconnected porosities and suitable mechanical properties. They can be filled with different components such as cells or soluble growth factors at specific locations


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 155 - 155
1 Jul 2014
Hutchinson R Choudry Q McLauchlan G
Full Access

Summary. The 80% porous structure of trabecular metal allows for bone ingrowth in more than 90% of the available surface. The Nexgen LPS Uncemented Knee using a trabecular metal tibial component has performed well at minimum of 5 years’ follow-up. Introduction. Total Knee Arthroplasty prostheses most frequently used in today's practice have cemented components. These have shown excellent clinical results. The fixation can however weaken with time, and cement debris within the articulation can lead to accelerated wear. Cementless implants are less commonly used, but some have also shown good long-term clinical results. The potential advantages of cementless implants are retention of bone stock, less chance of third-body wear due to the absence of cement, shorter operative time, and easier treatment of periprosthetic fractures. The posterior stabilised knee replacement has been said to increase tangential shear stresses on the tibial component and increases contact stresses on the cam and post mechanism hence the great debate of cruciate retaining or cruciate sacrificing implants. Objectives. We report the results of a prospective cohort of consecutive primary total knee arthroplasties using an uncemented posterior stabilised prosthesis using a trabecular metal (tantalum) tibial component at a minimum 5-year follow-up. Methods. Prospective 5 year follow-up of patients undergone an uncemented posterior stabilised total knee replacement using a trabecular metal tibial component (NexgenLPS). Clinical examination, Oxford knee score, Knee society score, SF12 and radiological evaluation undertaken at review. Results. 81 patients, 45 female, 36 male. Left 31, Right 50. Mean age 74.3 yrs range (51–90). SF12, mean: 31.8 range (25–37). Oxford Knee Score Pre-op Mean 20.1 range (9–36) Post op: Mean 32.1 range (9–48). Knee Society score. Pain Mean 91.8; range (60–100). Functional score mean 76.2; range (30–100). Mean Range of movement 110.5 degrees range (90–125). No evidence of loosening at 5 yrs. No deep infection. No Revisions. Conclusion. Although there are a variety of methods of achieving satisfactory initial fixation in cementless components, trabecular metal has an advantage owing to its cellular structure resembling bone. The 80% porous structure of trabecular metal allows for bone ingrowth in more than 90% of the available surface. The Nexgen LPS Uncemented Knee using a trabecular metal tibial component used in this series has shown no evidence of loosening at a minimum of 5 years’ follow-up and the prosthesis as a whole has performed very well clinically. Its early results are comparable to those prostheses most commonly used as reported by the arthroplasty registers. The longer term results from this prosthesis are awaited with interest


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 343 - 343
1 Jul 2014
Speirs A Huang A Lamontagne M Beaule P
Full Access

Summary Statement. This study quantifies compositional differences in cartilage between CAM deformities of symptomatic FAI patients and normal cadaver controls. It shows a resemblance of CAM-FAI cartilage with those of osteoarthritic hips, objectively supporting previous hypothesis of abnormal contact stresses in CAM-FAI. Introduction. Degeneration of cartilage within articular joints is a pathological feature of osteoarthritis (OA). Femoroacetabular impingement (FAI), a condition of abnormal contact between the articular surfaces of the femur and acetabulum, has been widely associated with early onset OA of the hip. The purpose of this study was to quantitatively compare the proteoglycan (PG) content of the weight-bearing cartilage in surgical FAI patients versus those of cadavers without FAI. Patients and Methods. Osteochondral bone plugs were taken from the antero-superior weight-bearing surface of cam-deformities on the femoral heads of 11 surgical cam-FAI patients. These were compared to control specimens taken from 11 cadaveric hips (7 donors) at approximately the same location. The PG content of the specimens were then histologically compared using the model presented by Martin et al. In this method, Safranin-O binds to chondroitin sulfate, a PG abundant in cartilage, allowing it to be visualised and quantitatively compared. Specifically, the specimens were fixed in formalin, decalcified in EDTA and then sectioned to 7um thick. They were then stained with Safranin-O, which binds specifically and stoichiometrically with proteoglycan. This model allows for quantitative comparison of PG content whereby the red content (R. c. ) of the sample is linearly correlated with the amount of PG present in the sample when viewed under 4x microscopic magnification. Here, the red content was sampled by depth coordinate with superficial and deep zones analyzed. Results. In general, the R. C. in the cartilage of surgical patients was lower than that of the cadaveric controls in both the superficial and deep layers tested. This correlates to a decrease in the PG of the test subjects. In the surgical specimens, R. C. ranged from 0 – 31.9 in the superficial layer and 0 – 139.6 in the deep. When compared by layers, the R. C. of the superficial 30% specimens averaged an R. C. of 17.5 compared to 88.6 in the cadaveric controls. This represents an 80.2% depletion in the PG content. In the deep 70% layer, the average R. C. of the test subjects was 52.4, compared with 129.2 in the cadaveric controls. This represents a 59% depletion in the PG content of the deep layer. These results show large compositional change in the cartilage of surgical FAI versus control specimens that were statistically significant in all levels (superficial, deep, total yielding p<0.001, p=0.001, p<0.001, respectively). Discussion. The idea of abnormal cartilage at the cam deformity has been previously demonstrated through similar resection and staining techniques. Wagner et al showed cellular activity and qualitatively noted PG depletion in the cartilage on the Cam deformity, consistent with OA. However a quantitative assessment of PG content provides a better estimate of impingement severity and disease state. Results from this current study objectively corroborate previously obtained qualitative data, supporting existing hypothesis of abnormal contact stresses in cam-FAI while giving a more robust, objective quantification of cartilage breakdown at CAM sites


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 310 - 310
1 Jul 2014
Kumar N Chen Y Ahmed Q Lee V Wong H
Full Access

Summary. This is the first ever study to report the successful elimination of malignant cells from salvaged blood obtained during metastatic spine tumour surgery using a leucocyte depletion filter. Introduction. Catastrophic bleeding is a significant problem in metastatic spine tumour surgery (MSTS). However, intaoperative cell salvage (IOCS) has traditionally been contraindicated in tumour surgery because of the theoretical concern of promoting tumour dissemination by re-infusing tumour cells into the circulation. Although IOCS has been extensively investigated in patients undergoing surgery for gynaecological, lung, urological, gastrointestinal, and hepatobiliary cancers, to date, there is no prior report of the use of IOCS in MSTS. We conducted a prospective observational study to evaluate whether LDF can eliminate tumour cells from blood salvaged during MSTS. Patients & Methods. After Institutional Review Board (IRB) approval, 21 consecutive patients with metastatic spinal tumours from a known epithelial primary (defined as originating from breast, prostate, thyroid, renal, colorectal, lung, nasopharyngeal) who were scheduled for MSTS were recruited with informed consent. During surgery, a IOCS device (Dideco, Sorin Group, Italy) was used to collect shed blood from the operative field. Salvaged blood was then passed through a leucocyte depletion filter (RS1VAE, Pall Corporation, UK). 15-ml specimens of blood were taken from each of three consecutive stages: (i) operative field prior to cell saver processing (Stage A); (ii) transfusion bag post-cell saver processing (Stage B); (iii) filtered blood after passage through LDF (Stage C). Cell blocks were prepared by the pathology department using a standardised laboratory protocol. From each cell block, 1 haematoxylin and eosin (H&E) slide, and 3 slides each labelled with one of the following monoclonal mouse cytokeratin antibodies AE1/3, MNF 116 and CAM 5.2 were prepared. The cytokeratin antibodies are highly sensitive and specific markers to identify tumour cells of epithelial origin. These slides were read by one of two consultant pathologists who were provided full access to information on operative notes, but were blinded to the actual stages from which the slides were derived. Results. One case was excluded when the final diagnosis was revised to infection instead of metastatic spine tumour. Of the remaining cases, 7/21 tested positive for tumour cells in Stage A, 2 positive in Stage B. No specimen tested positive for tumour cells in Stage C. In 5 cases, posterior instrumentation without tumour manipulation was performed. Discussion/Conclusion. In this first-ever study of cell saver use in spine tumour surgery, we prove that leucocyte-depletion filters (LDF) can effectively eliminate tumour cells from blood salvaged during MSTS. It is now possible to conduct a clinical trial to evaluate IOCS-LDF use in MSTS. Our results are consistent with published results of similar studies performed on IOCS and LDF use outside the field of orthopaedic surgery. Spinal metastases originate from a myriad of primary cancers across various organ systems. If LDF can remove tumour cells from blood salvaged during surgery for spinal metastasis of different histological origin, then the finding can likely be extrapolated to several other fields of surgery where IOCS and LDF have not yet been attempted such as: neurosurgery, otolaryngology and general musculoskeletal oncology. Our results form a proof-of-concept for a paradigm shift in thinking regarding autotransfusion during spine tumour surgery


Bone & Joint Research
Vol. 5, Issue 12 | Pages 610 - 618
1 Dec 2016
Abubakar AA Noordin MM Azmi TI Kaka U Loqman MY

In vivo animal experimentation has been one of the cornerstones of biological and biomedical research, particularly in the field of clinical medicine and pharmaceuticals. The conventional in vivo model system is invariably associated with high production costs and strict ethical considerations. These limitations led to the evolution of an ex vivo model system which partially or completely surmounted some of the constraints faced in an in vivo model system. The ex vivo rodent bone culture system has been used to elucidate the understanding of skeletal physiology and pathophysiology for more than 90 years. This review attempts to provide a brief summary of the historical evolution of the rodent bone culture system with emphasis on the strengths and limitations of the model. It encompasses the frequency of use of rats and mice for ex vivo bone studies, nutritional requirements in ex vivo bone growth and emerging developments and technologies. This compilation of information could assist researchers in the field of regenerative medicine and bone tissue engineering towards a better understanding of skeletal growth and development for application in general clinical medicine.

Cite this article: A. A. Abubakar, M. M. Noordin, T. I. Azmi, U. Kaka, M. Y. Loqman. The use of rats and mice as animal models in ex vivo bone growth and development studies. Bone Joint Res 2016;5:610–618. DOI: 10.1302/2046-3758.512.BJR-2016-0102.R2.


Bone & Joint Research
Vol. 4, Issue 4 | Pages 65 - 69
1 Apr 2015
Kearney RS Parsons N Underwood M Costa ML

Objectives

The evidence base to inform the management of Achilles tendon rupture is sparse. The objectives of this research were to establish what current practice is in the United Kingdom and explore clinicians’ views on proposed further research in this area. This study was registered with the ISRCTN (ISRCTN68273773) as part of a larger programme of research.

Methods

We report an online survey of current practice in the United Kingdom, approved by the British Orthopaedic Foot and Ankle Society and completed by 181 of its members. A total of ten of these respondents were invited for a subsequent one-to-one interview to explore clinician views on proposed further research in this area.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 680 - 684
1 May 2008
Simon DWN Clarkin CE Das-Gupta V Rawlinson SCF Emery RJ Pitsillides AA

We examined cultured osteoblasts derived from paired samples from the greater tuberosity and acromion from eight patients with large chronic tears of the rotator cuff.

We found that osteoblasts from the tuberosity had no apparent response to mechanical stimulation, whereas those derived from the acromion showed an increase in alkaline phosphatase activity and nitric oxide release which is normally a response of bone cells to mechanical strain. By contrast, we found that cells from both regions were able to respond to dexamethasone, a well-established promoter of osteoblastic differentiation, with the expected increase in alkaline phosphatase activity.

Our findings indicate that the failure of repair of the rotator cuff may be due, at least in part, to a compromised capacity for mechanoadaptation within the greater tuberosity. It remains to be seen whether this apparent decrease in the sensitivity of bone cells to mechanical stimulation is the specific consequence of the reduced load-bearing history of the greater tuberosity in these patients.