Advertisement for orthosearch.org.uk
Results 1 - 20 of 25
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 67 - 67
1 Dec 2020
Debnath A Rathi N Suba S Raju D
Full Access

Introduction. Intraarticular calcaneal fractures often need open reduction and internal fixation (ORIF) with plate osteosynthesis. The wound complication is one of the common problems encountered following this and affects the outcome adversely. Our study was done to assess how far postoperative slab/cast can avert wound complications. Methods. Out of 42 patients with unilateral intraarticular calcaneal fractures, 20 were offered postoperative slab/cast and this was continued for six weeks. The remaining 22 patients were not offered any plaster. All patients were followed-up for two years. Results. The incidence of wound dehiscence was 2 in the plaster group as well as 8 in the non-plaster group and this was statistically significant (p = 0.02). Also, significantly lower heel widening was reported in the plaster group (p = 0.03). Although, there was no significant difference in the patient-reported outcome (Maryland Foot Score) and the incidence of pain between the two groups, the occurrence of neurological deficit following surgery and the postoperative range of movements were comparable in these two groups. Conclusion. Thus, it may be concluded that postoperative plaster application for the initial six weeks could be a low-cost yet effective way to reduce wound complications following plate osteosynthesis in intraarticular calcaneal fractures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 85 - 85
1 Dec 2020
Stefanov A Ivanov S Zderic I Baltov A Rashkov M Gehweiler D Richards G Gueorguiev B Enchev D
Full Access

Treatment of comminuted intraarticular calcaneal fractures remains controversial and challenging. Anatomic reduction with stable fixation has demonstrated better outcomes than nonoperative treatment of displaced intraarticular fractures involving the posterior facet and anterior calcaneocuboid joint (CCJ) articulating surface of the calcaneus. The aim of this study was to investigate the biomechanical performance of three different methods for fixation of comminuted intraarticular calcaneal fractures. Comminuted calcaneal fractures, including Sanders III-AB fracture of the posterior facet and Kinner II-B fracture of the CCJ articulating calcaneal surface, were simulated in 18 fresh-frozen human cadaveric lower legs by means of osteotomies. The ankle joint, medial soft tissues and midtarsal bones along with the ligaments were preserved. The specimens were randomized according to their bone mineral density to 3 groups for fixation with either (1) 2.7 mm variable-angle locking anterolateral calcaneal plate in combination with one 4.5 mm and one 6.5 mm cannulated screw (Group 1), (2) 2.7 mm variable-angle locking lateral calcaneal plate (Group 2), or (3) interlocking calcaneal nail with 3.5 mm screws in combination with 3 separate 4.0 mm cannulated screws (Group 3). All specimens were biomechanically tested until failure under axial loading with the foot in simulated midstance position. Each test commenced with an initial quasi-static compression ramp from 50 N to 200 N, followed by progressively increasing cyclic loading at 2Hz. Starting from 200 N, the peak load of each cycle increased at a rate of 0.2 N/cycle. Interfragmentary movements were captured by means of optical motion tracking. In addition, mediolateral X-rays were taken every 250 cycles with a triggered C-arm. Varus deformation between the tuber calcanei and lateral calcaneal fragments, plantar gapping between the anterior process and tuber fragments, displacement at the plantar aspect of the CCJ articular calcaneal surface, and Böhler angle were evaluated. Varus deformation of 10° was reached at significantly lower number of cycles in Group 2 compared to Group 1 and Group 3 (P ≤ 0.017). Both cycles to 10° plantar gapping and 2 mm displacement at the CCJ articular calcaneal surface revealed no significant differences between the groups (P ≥ 0.773). Böhler angle after 5000 cycles (1200 N peak load) had significantly bigger decrease in Group 2 compared to both other groups (P ≤ 0.020). From biomechanical perspective, treatment of comminuted intraarticular calcaneal fractures using variable-angle locked plate with additional longitudinal screws or interlocked nail in combination with separate transversal screws seems to provide superior stability as opposed to variable-angle locked plating only


Bone & Joint Research
Vol. 5, Issue 11 | Pages 538 - 543
1 Nov 2016
Weeks BK Hirsch R Nogueira RC Beck BR

Objectives. The aim of the current study was to assess whether calcaneal broadband ultrasound attenuation (BUA) can predict whole body and regional dual-energy x-ray absorptiometry (DXA)-derived bone mass in healthy, Australian children and adolescents at different stages of maturity. Methods. A total of 389 boys and girls across a wide age range (four to 18 years) volunteered to participate. The estimated age of peak height velocity (APHV) was used to classify children into pre-, peri-, and post-APHV groups. BUA was measured at the non-dominant heel with quantitative ultrasonometry (QUS) (Lunar Achilles Insight, GE), while bone mineral density (BMD) and bone mineral content (BMC) were examined at the femoral neck, lumbar spine and whole body (DXA, XR-800, Norland). Associations between BUA and DXA-derived measures were examined with Pearson correlations and linear regression. Participants were additionally ranked in quartiles for QUS and DXA measures in order to determine agreement in rankings. Results. For the whole sample, BUA predicted 29% of the study population variance in whole body BMC and BMD, 23% to 24% of the study population variance in lumbar spine BMC and BMD, and 21% to 24% of the variance in femoral neck BMC and BMD (p < 0.001). BUA predictions were strongest for the most mature participants (pre-APHV R. 2. = 0.03 to 0.19; peri-APHV R. 2. = 0.05 to 0.17; post-APHV R. 2. = 0.18 to 0.28) and marginally stronger for girls (R. 2. = 0.25-0.32, p < 0.001) than for boys (R. 2. = 0.21-0.27, p < 0.001). Agreement in quartile rankings between QUS and DXA measures of bone mass was generally poor (27.3% to 38.2%). Conclusion. Calcaneal BUA has a weak to moderate relationship with DXA measurements of bone mass in children, and has a tendency to misclassify children on the basis of quartile rankings. Cite this article: B. K. Weeks, R. Hirsch, R. C. Nogueira, B. R. Beck. Is calcaneal broadband ultrasound attenuation a valid index of dual-energy x-ray absorptiometry-derived bone mass in children? Bone Joint Res 2016;5:538–543. DOI: 10.1302/2046-3758.511.BJR-2016-0116.R1


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 77 - 77
1 Dec 2020
Ivanov S Stefanov A Zderic I Gehweiler D Richards G Raykov D Gueorguiev B
Full Access

Displaced intraarticular calcaneal fractures are debilitating injuries with significant socioeconomic and psychological effects primarily affecting patients in active age between 30 and 50 years. Recently, minimally and less invasive screw fixation techniques have become popular as alternative to locked plating. The aim of this study was to analyze biomechanically in direct comparison the primary stability of 3 different cannulated screw configurations for fixation of Sanders type II-B intraarticular calcaneal fractures. Fifteen fresh-frozen human cadaveric lower limbs were amputated mid-calf and through the Chopart joint. Following, soft tissues at the lateral foot side were removed, whereas the medial side and Achilles tendon were preserved. Reproducible Sanders type II-B intraarticular fracture patterns were created by means of osteotomies. The proximal tibia end and the anterior-inferior aspect of the calcaneus were then embedded in polymethylmethacrylate. Based on bone mineral density measurements, the specimens were randomized to 3 groups for fixation with 3 different screw configurations using two 6.5 mm and two 4.5 mm cannulated screws. In Group 1, two parallel longitudinal screws entered the tuber calcanei above the Achilles tendon insertion and proceeded to the anterior process, and two transverse screws fixed the posterior facet perpendicular to the fracture line. In Group 2, two parallel screws entered the tuber calcanei below the Achilles tendon insertion, aiming at the anterior process, and two transverse screws fixed the posterior facet. In Group 3, two screws were inserted along the bone axis, entering the tuber calcanei above the Achilles tendon insertion and proceeding to the central-inferior part of the anterior process. In addition, one transverse screw was inserted from lateral to medial for fixation of the posterior facet and one oblique screw – inserted from the posterior-plantar part of the tuber calcanei – supported the posterolateral part of the posterior facet. All specimens were tested in simulated midstance position under progressively increasing cyclic loading at 2 Hz. Starting from 200N, the peak load of each cycle increased at a rate of 0.1 N/cycle. Interfragmentary movements were captured by means of optical motion tracking and triggered mediolateral x-rays. Plantar movement, defined as displacement between the anterior process and the tuber calcanei at the most inferior side was biggest in Group 2 and increased significantly over test cycles in all groups (P = 0.001). Cycles to 2 mm plantar movement were significantly higher in both Group 1 (15847 ± 5250) and Group 3 (13323 ± 4363) compared to Group 2 (4875 ± 3480), P = 0.048. Medial gapping after 2500 cycles was significantly bigger in Group 2 versus Group 3, P = 0.024. No intraarticular displacement was observed in any group during testing. From biomechanical perspective, screw configuration implementing one oblique screw seems to provide sufficient hindfoot stability in Sanders Type II-B intraarticular calcaneal fractures under dynamic loading. Posterior facet support by means of buttress or superiorly inserted longitudinal screws results in less plantar movement between the tuber calcanei and anterior fragments. On the other hand, inferiorly inserted longitudinal screws seem to be associated with bigger interfragmentary movements


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1257 - 1263
1 Sep 2006
Richter M Droste P Goesling T Zech S Krettek C

Different calcaneal plates with locked screws were compared in an experimental model of a calcaneal fracture. Four plate models were tested, three with uniaxially-locked screws (Synthes, Newdeal, Darco), and one with polyaxially-locked screws (90° ± 15°) (Rimbus). Synthetic calcanei were osteotomised to create a fracture model and then fixed with the plates and screws. Seven specimens for each plate model were subjected to cyclic loading (preload 20 N, 1000 cycles at 800 N, 0.75 mm/s), and load to failure (0.75 mm/s). During cyclic loading, the plate with polyaxially-locked screws (Rimbus) showed significantly lower displacement in the primary loading direction than the plates with uniaxially-locked screws (mean values of maximum displacement during cyclic loading: Rimbus, 3.13 mm (. sd. 0.68); Synthes, 3.46 mm (. sd. 1.25); Darco, 4.48 mm (. sd. 3.17); Newdeal, 5.02 mm (. sd. 3.79); one-way analysis of variance, p < 0.001). The increased stability of a plate with polyaxially-locked screws demonstrated during cyclic loading compared with plates with uniaxially-locked screws may be beneficial for clinical use


Bone & Joint Research
Vol. 4, Issue 5 | Pages 78 - 83
1 May 2015
Martinkevich P Rahbek O Møller-Madsen B Søballe K Stilling M

Objectives. Lengthening osteotomies of the calcaneus in children are in general grafted with bone from the iliac crest. Artificial bone grafts have been introduced, however, their structural and clinical durability has not been documented. Radiostereometric analysis (RSA) is a very accurate and precise method for measurements of rigid body movements including the evaluation of joint implant and fracture stability, however, RSA has not previously been used in clinical studies of calcaneal osteotomies. We assessed the precision of RSA as a measurement tool in a lateral calcaneal lengthening osteotomy (LCLO). Methods. LCLO was performed in six fixed adult cadaver feet. Tantalum markers were inserted on each side of the osteotomy and in the cuboideum. Lengthening was done with a plexiglas wedge. A total of 24 radiological double examinations were obtained. Two feet were excluded due to loose and poorly dispersed markers. Precision was assessed as systematic bias and 95% repeatability limits. Results. Systematic bias was generally below 0.10 mm for translations. Precision of migration measurements was below 0.2 mm for translations in the osteotomy. Conclusion. RSA is a precise tool for the evaluation of stability in LCLO. Cite this article: Bone Joint Res 2015;4:78–83


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 78 - 78
1 Apr 2018
Peiffer M Burssens A Verstraete M Boey H Clockaerts S Leenders T Victor J
Full Access

Background. A calcaneal medial osteotomy (CMO) is a surgical procedure frequently performed to correct a valgus alignment of the hindfoot. However currently little is known on its accurate influence on hindfoot alignment (HA). Aim. To assess the influence of a CMO on HA in both 2D and 3D measurements using weightbearing CT (WBCT). Methods. Twelve patients with a mean age of 49,4 years (range 18–67yrs) were prospectively included. Indications for surgical correction by a CMO with a solitary translation of the calcaneus consisted of an adult acquired flat foot stage II (N=10) and a talocalcaneal coalition (N=2). Fixation of the osteotomy was performed either using a step plate or double screw. A WBCT was obtained pre- and post-operative. HA was assessed by an angle between the anatomical tibia axis and the axis connecting the inferior calcaneus point and the middle of the talus in the coronal plane (HA. 2D. ) using Curvebeam® software. The tibia in the HA was separately assessed by the anatomical tibia axis (TA. X 2D. ). The same method was translated in 3D using 3-Matic® software with a Cartesian coordinate system originating in the inferior point of the calcaneus (HA. 3D. and TA. x 3D. ). Results. Both the mean pre-op HA. 2D. =12.8°± 4.5 and HA. 3D. =21.1°± 8.4 of valgus improved significantly post-operatively to a HA. 2D. =4.2°±4.5 and a HA. 3D. =11,9°± 6.1 (P < 0.001). Additionally, the mean pre-op TA. X 2D. = 4°± 2.6 and TA. X 3D. = 7,2 °± 3.2 showed a significant improvement to a TA. X 2D. = 3.1°± 2.7 and a TA. X 3D. = 6.1 °± 3.4 post-operatively (P < 0.05). The inter-rater reliability of the 2D measurement method with a mean ICC. HA2D. =0.74 and a mean ICC. TA2D. = 0.77 showed to be lower when compared to the 3D measurement method with a mean ICC. HA3D. =0.94 and a mean ICC. TA3D. =0.89. Conclusion. This study shows an effective correction of the valgus position from the calcaneus measured both in 2D and 3D when using a surgical CMO. The novelty is the marked influence on the tibia, which could now be accurately assessed using a weightbearing CT and additional 3D measurements. This resulted in 10% of the achieved HA correction, when analyzed both in 2D and 3D. This information could be of use when performing a pre-operative planning of a hindfoot deformity


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 22 - 22
1 May 2017
Farrell B Lin C Moon C
Full Access

Background

Surgical management of calcaneus fractures is demanding and has a high risk of wound complications. Traditionally these fractures are managed with splinting until swelling has subsided. We describe a novel protocol for the management of displaced intra-articular calcaneus fractures utilising a temporizing external fixator and staged conversion to plate fixation through a sinus tarsi approach. The goal of this technique is to allow for earlier treatment with open reduction and internal fixation, minimise the amount of manipulation required at the time of definitive fixation and reduce the wound complication rate seen with the extensile approach.

Methods

The records of patients with displaced calcaneus fractures from 2010–2014 were retrospectively reviewed. A total of 10 patients with 12 calcaneus fractures were treated with this protocol. All patients underwent ankle-spanning medial external fixation within 48 hours of injury. Patients underwent conversion to open plate fixation through a sinus tarsi approach when skin turgor had returned to normal. Time to surgery, infection rate, wound complications, radiographic alignment, and time to radiographic union were recorded.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 44 - 45
1 Feb 2024
Marson BA

This edition of the Cochrane Corner looks at the three reviews that were published in the second half of 2023: surgical versus non-surgical interventions for displaced intra-articular calcaneal fractures; cryotherapy following total knee arthroplasty; and physical activity and education about physical activity for chronic musculoskeletal pain in children and adolescents


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 91 - 91
1 Dec 2020
Hanberg P Bue M Öbrink-Hansen K Thomassen M S⊘balle K Stilling M
Full Access

Tourniquet is widely used in extremity surgery. In order to prevent surgical site infection, correct timing of antimicrobial prophylaxis and tourniquet inflation is important. We aimed to evaluate the time for which the free drug concentration of cefuroxime is maintained above the minimal inhibitory concentration (T>MIC) in subcutaneous tissue and calcaneal cancellous bone during three clinically relevant tourniquet application scenarios. Twenty-four female pigs were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in calcaneal cancellous bone and subcutaneous tissue, and a tourniquet cuff was applied on a randomly picked leg of each pig. Subsequently, the pigs were randomized into three groups to receive 1.5 g of cefuroxime by intravenous injection 15 min prior to tourniquet inflation (Group A), 45 min prior to tourniquet inflation (Group B), and at the tourniquet release (Group C). The tourniquet duration was 90 min in all groups. Dialysates and venous blood samples were collected eight-hours postcefuroxime administration. Cefuroxime concentrations were maintained above the clinical breakpoint MIC for Staphylococcus aureus (4 μg/mL) in calcaneal cancellous bone and subcutaneous tissue throughout the 90 min tourniquet duration in Group A and B. Cefuroxime administration at tourniquet release (Group C) resulted in concentrations above 4 μg/mL for a minimum of 3.5 hours in the tissues on the tourniquet side. There were no significant differences in the T>MIC (4 μg/mL) in subcutaneous tissue or calcaneal cancellous bone between the three groups. However, Group A tended toward shorter T>MIC in tourniquet calcaneal cancellous bone compared to Group C (p=0.08). We conclude that administration of cefuroxime (1.5 g) in the 15–45 min window prior to tourniquet inflation resulted in sufficient calcaneal cancellous bone and subcutaneous tissue concentrations throughout the 90 min tourniquet application. If the target is to maintain postoperative cefuroxime concentrations above relevant MIC values, our results suggest that a second dose of cefuroxime should be administered at tourniquet release


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 7 - 7
2 Jan 2024
Raes L Peiffer M Kvarda P Leenders T Audenaert EA Burssens A
Full Access

A medializing calcaneal osteotomy (MCO) is one of the key inframalleolar osteotomies to correct progressive collapsing foot deformity (PCFD). While many studies were able to determine the hind- and midfoot alignment after PCFD correction, the subtalar joint remained obscured by superposition on plain radiography. Therefore, we aimed to perform a 3D measurement assessment of the hind- and subtalar joint alignment pre- compared to post-operatively using weightbearing CT (WBCT) imaging. Fifteen patients with a mean age of 44,3 years (range 17-65yrs) were retrospectively analyzed in a pre-post study design. Inclusion criteria consisted of PCFD deformity correct by MCO and imaged by WBCT. Exclusion criteria were patients who had concomitant midfoot fusions or hindfoot coalitions. Image data were used to generate 3D models and compute the hindfoot - and talocalcaneal angle as well as distance maps. Pre-operative radiographic parameters of the hindfoot and subtalar joint alignment improved significantly relative to the post-operative position (HA, MA. Sa. , and MA. Co. ). The post-operative talus showed significant inversion, abduction, and dorsiflexion of the talus (2.79° ±1.72, 1.32° ±1.98, 2.11°±1.47) compared to the pre-operative position. The talus shifted significantly different from 0 in the posterior and superior direction (0.62mm ±0.52 and 0.35mm ±0.32). The distance between the talus and calcaneum at the sinus tarsi increased significantly (0.64mm ±0.44). This study found pre-dominantly changes in the sagittal, axial and coronal plane alignment of the subtalar joint, which corresponded to a decompression of the sinus tarsi. These findings demonstrate the amount of alternation in the subtalar joint alignment that can be expected after MCO. However, further studies are needed to determine at what stage a calcaneal lengthening osteotomy or corrective arthrodesis is indicated to obtain a higher degree of subtalar joint alignment correction


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 92 - 92
1 Dec 2020
Hanberg P Bue M Kabel J J⊘rgensen AR Jessen C S⊘balle K Stilling M
Full Access

Tourniquet is widely used in orthopedic surgery to reduce intraoperative bleeding and improve visualization. We evaluated the effect of tourniquet application on both peri- and postoperative cefuroxime concentrations in subcutaneous tissue, skeletal muscle, calcaneal cancellous bone, and plasma. The primary endpoint was the time for which the free drug concentration of cefuroxime was maintained above the clinical breakpoint minimal inhibitory concentration (T>MIC) forStaphylococcus aureus (4 µg/mL). Ten patients scheduled for hallux valgus or hallux rigidus surgery were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in subcutaneous tissue, skeletal muscle, and calcaneal cancellous bone. A tourniquet was applied on the thigh of the leg scheduled for surgery. Cefuroxime (1.5 g) was administered intravenously as a bolus 15 minutes prior to tourniquet inflation, followed by a second dose 6 hours later. The mean tourniquet duration (range) was 65 (58; 77) minutes. Dialysates and venous blood samples were collected for 12 hours. For cefuroxime the T>MIC (4 μg/mL) ranged between 4.8–5.4 hours across compartments, with similar results for the tourniquet and non-tourniquet leg. Comparable T>MIC and penetration ratios were found for the first and second dosing intervals. We concluded that administration of cefuroxime (1.5 g) 15 minutes prior to tourniquet inflation is safe in order to achieve tissue concentrations above 4 µg/mL throughout surgery. A tourniquet application time of approximately 1 hour did not affect the cefuroxime tissue penetration in the following dosing interval


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 25 - 25
1 Apr 2018
de Bot R Stevens J Hermus J Staal H van Rhijn L Witlox A
Full Access

Purpose. Flat feet are an important cause of foot problems in children. The flexible flat foot is the most common form and is normally physiological and asymptomatic. Further assessment is necessary when a symptomatic flat foot persists. Surgical interventions are indicated when conservative therapies have failed. The Kalix arthroereisis is a surgical option and is placed in the subtalar joint of the foot, thereby preventing hyperpronation, and stabilizes the foot against excessive movements. The purpose of this study was to evaluate the functional and radiological outcomes of pediatric patients who had undergone a Kalix implantation for the treatment of a symptomatic flexible flat foot. Methods. Patient files of our institution were searched for patients who underwent a Kalix implantation between 2009 and 2014. Sixteen patients (26 feet) with symptomatic flexible flat feet were clinically and radiographically evaluated in this retrospective study. The calcaneal pitch and Meary”s angle were measured on the pre-, and postoperative follow-up radiographs and patient satisfaction survey was performed at follow-up to gain insight into functional outcome and satisfaction after the intervention. Results. Surgery was performed on an average age at 12.5 (range:10–15) years with a mean time from surgery to follow-up of 45.1±3.16 (range:18–78) months. There was a statistically significant increase in calcaneal pitch of 2.9° (11.7°to14.6°) and decrease in Meary”s angle of 15.8° (23.2° to7.85°) after surgery. The postoperative angles were maintained during follow-up, for both the calcaneal pitch (13.89°) and Meary”s angle (8.67°) in patients with the Kalix in situ (n=9/26) and in patients with the Kalix removed (15.4° and 7.8° respectively, n=17/26). The patient satisfaction survey shows that the majority of patients were satisfied regarding the state (81%) and appearance (75%) of their feet at follow-up. The majority never complained about their feet (81%) and heavy exercise was the major cause of complaints (23%). Limitations during walking were usually not the case (81%), though some patient experienced limitations during running (57%). Most reported preoperative complaints were pain, walking problems or a combination of both. The majority of these are relieved after surgery and patients were still asymptomatic at follow up. Conclusion. Kalix implantation improves the calcaneal pitch and Meary”s angle, thereby restoring foot anatomy towards a normal anatomy. These improvements were observed directly postoperatively and remained at follow-up. In addition, relieve of symptoms was observed postoperatively and the majority of patients were even satisfied at follow-up. We therefore suggest that Kalix arthroereisis is an appropriate treatment option for pediatric patients with symptomatic flexible flat feet. Significance. This was the first study evaluating functional and radiological outcomes of the Kalix arthroereisis in patients with symptomatic flexible flat feet


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 100 - 100
1 Nov 2021
Papadia D Comincini F Pirchio P Puggioni V Bellanova G
Full Access

Introduction and Objective. Management of bone loss associated with bone contamination or infection represents a double biological and clinical challenge frequent in traumatology. The advent of new biomaterials can allow a different approach in the treatment of bone gap. The purpose of this study was to evaluate the prophylactic and therapeutic effectiveness of addition of a new absorbable bone substitute (BS) eluting different antibiotics in reconstruction of bone defects after infections and fractures with soft tissue damage. Materials and Methods. We conducted a review of patients with contaminated or infected bone defects treated using a new biomaterial, a porous composite of collagen matrices and Beta tricalcium phosphate (β TCP), able to provide a long-term release of different antibiotics. We have included treatment of osteomyelitis and osteosynthesis of exposed fracture (Gustilo Anderson 1–3b) or fractures with soft tissue damage and high risk of contamination. Surgical technique included debridement filling bone defect with BS eluting antibiotics, osteosynthesis (plate, nail, external fixator, kirschner wire), soft tissue coverage, and systemic antibiotic therapy. Radiographic and clinical data including complications (wound dehiscence, superficial or deep infection, osteomyelitis) were collected. Results. We treated 25 patients (21 male, 4 female) with mean age 47 yrs. (range 21–83). The locations treated (for incidence) was: 9 femurs (7 plates, 2 nail), 7 calcanei (one bilateral), 3 tibias, 2 forearms, 2 metatarsi, 2 hands, 1 elbow. 6 patients had large bone loss. 7 patients had bone infections (4 were Cierny Madern 4); 8 patients had osteosynthesis of exposed fractures Gustilo Anderson 1–3b (9 plate, one bilateral calcaneus). 8 patients had treatment for pseudoarthrosis of exposed fractures (6 femurs, 1 forearm, 1 metatarsus) and 3 patients a prophylactic treatment for calcaneal fractures with soft tissue damage. 4 deep infection were treated with multiple surgical debridement and new filling bone defect with BS eluting antibiotic with infection eradication. We have used a combination of vancomycin and gentamicin on 15 cases, vancomycin alone on 4 cases, combination of vancomycin and amikacin on 1 case and amikacin and Linezolid in a targeted multi drug resistance. At final follow-up functional outcome was good in all cases with bone healing. Conclusions. Extensive debridement is a fundamental requisite for eradication of bone infections and contamination. Filling of the bone void with loaded bio-composite eluting diversifiable local antibiotics with synergistic anti-biofilm activity is desirable. Treatment of this bone defects are advantaged when combining his reconstruction with BS and the possibility of release high antibiotic concentration at least for 10 days. This is an important complementing prophylactic and therapeutic antimicrobial option with adjuvant role to systemic therapy that enlarges the success rate


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 26 - 26
1 Jun 2012
Young P Bell S MacDuff E Mahendra A
Full Access

Bony tumours of the foot account for approximately 3% of all osseous tumours. However, literature regarding os calcis tumours comprises individual case reports, short case series or literature reviews, with the last large case series in 1973. We retrospectively reviewed the medical notes and imaging for all patients with calcaneal tumours recorded in the Scottish Bone Tumour Registry since the 1940's. Demographics, presentation, investigation, histology, management and outcome were reviewed. 38 calcaneal tumours were identified. Male to female ratio 2:1, mean age at presentation 30 with heel pain and swelling, average length of symptoms 9 months. 4 cases present with pathological fracture. 24 tumours benign including 6 unicameral bone cysts, 3 chondroblastoma, 3 PVNS with calcaneal erosion, and a wide variety of individual lesions. 13 malignant tumours comprising 6 osteosarcoma, 5 chondrosarcoma and 2 Ewings sarcoma. 1 metastatic carcinoma. Tumours of the calcaneus frequently are delayed in diagnosis due to their rarity and lack of clinician familiarity. They are more common in men and have a 1 in 3 risk of malignancy, covering a wide variety of lesions. Outcome is dependent on early diagnosis, timely surgery and most importantly neo-adjuvant chemotherapy. Diagnosis is often made on plain radiograph but MRI is the gold standard. We present the largest case series of calcaneal tumours, from our experience with the Scottish Bone Tumour Registry. Despite their rarity clinicians should maintain a high index of suspicion as accurate and timely diagnosis is important to management and outcome


Bone & Joint Research
Vol. 6, Issue 8 | Pages 464 - 471
1 Aug 2017
Li QS Meng FY Zhao YH Jin CL Tian J Yi XJ

Objectives. This study aimed to investigate the functional effects of microRNA (miR)-214-5p on osteoblastic cells, which might provide a potential role of miR-214-5p in bone fracture healing. Methods. Blood samples were obtained from patients with hand fracture or intra-articular calcaneal fracture and from healthy controls (HCs). Expression of miR-214-5p was monitored by qRT-PCR at day 7, 14 and 21 post-surgery. Mouse osteoblastic MC3T3-E1 cells were transfected with antisense oligonucleotides (ASO)-miR-214-5p, collagen type IV alpha 1 (COL4A1) vector or their controls; thereafter, cell viability, apoptotic rate, and the expression of collagen type I alpha 1 (COL1A1), type II collagen (COL-II), and type X collagen (COL-X) were determined. Luciferase reporter assay, qRT-PCR, and Western blot were performed to ascertain whether COL4A1 was a target of miR-214-5p. Results. Plasma miR-214-5p was highly expressed in patients with bone fracture compared with HCs after fracture (p < 0.05 or p < 0.01). Inhibition of miR-214-5p increased the viability of MC3T3-E1 cells and the expressions of COL1A1 and COL-X, but decreased the apoptotic rate and COL-II expression (p < 0.05 or p < 0.01). COL4A1 was a target of miR-214-5p, and was negatively regulated by miR-214-5p (p < 0.05 or p < 0.01). Overexpression of COL4A1 showed a similar impact on cell viability, apoptotic rate, and COL1A1, COL-II, and COL-X expressions inhibiting miR-214-5p (p < 0.01). Conclusion. Inhibition of miR-214-5p promotes cell survival and extracellular matrix (ECM) formation of osteoblastic MC3T3-E1 cells by targeting COL4A1. Cite this article: Q. S. Li, F. Y. Meng, Y. H. Zhao, C. L. Jin, J. Tian, X. J. Yi. Inhibition of microRNA-214-5p promotes cell survival and extracellular matrix formation by targeting collagen type IV alpha 1 in osteoblastic MC3T3-E1 cells. Bone Joint Res 2017;6:464–471. DOI: 10.1302/2046-3758.68.BJR-2016-0208.R2


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 5 - 5
1 Nov 2018
Samaila E Negri S Magnan B
Full Access

Total ankle replacement (TAR) is contraindicated in patients with significant talar collapse due to AVN and in these patients total talus body prosthesis has been proposed to restore ankle joint. To date, five studies have reported implantation of a custom-made talar body in patients with severely damaged talus, showing the limit of short-term damage of tibial and calcaneal thalamic joint surfaces. Four of this kind of implants have been performed. The first two realized with “traditional” technology CAD-CAM has been performed in active patients affected by “missing talus” and now presents a survival follow-up of 15 and 17 years. For the third patient affected by massive talus AVN we designed a 3D printed porous titanium custom talar body prosthesis fixed on the calcaneum and coupled with a TAR, first acquiring high-resolution 3D CT images of the contralateral healthy talus that was “mirroring” obtaining the volume of fractured talus in order to provide the optimal fit. Then the 3D printed implant was manufactured. The fourth concern a TAR septic mobilization with high bone loss of the talus. The “two-stage” reconstruction conducted with the implant of total tibio-talo-calcaneal prosthesis “custom made” built with the same technology 3D, entirely in titanium and using the “trabecular metal” technology for the calcaneous interface. Weightbearing has progressively allowed after 6 weeks. No complications were observed. All the implants are still in place with an overall joint mobility ranging from 40° to 60°. This treatment requires high demanding technical skills and experience with TAR and foot and ankle trauma. The 15 years survival of 2 total talar prosthesis coupled to a TAR manufactured by a CAD-CAM procedure encourages consider this 3D printed custom implant as a new alternative solution for massive AVN and traumatic missing talus in active patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 7 - 7
1 Apr 2012
Mullen M Pillai A Fogg Q Kumar CS
Full Access

The extended lateral approach offers a safe surgical approach in the fixation of calcaneal fractures. Lateral plating of the calcaneum could put structures on the medial side at risk. The aim was to identify structures at risk on the medial side of the calcaneum from wires, drills or screws passed from lateral to medial. Ten embalmed cadaveric feet were dissected. A standard extended lateral approach was performed. The DePuy perimeter plate was first applied and 2mm K-wires were drilled through each of the holes. The medial side was now examined to determine the structures at risk through each hole. The process was repeated with the Stryker plate. The calcaneum was divided into 6 zones, by two vertical lines, from the margins of the posterior facet and a transverse line along the axis of the bone through the highest point of the peroneal tubercle. The DePuy and the Stryker plates have 12 screw positions, 5 of which are common. With both systems, screw positions in zone 1 risk injury to the medial plantar nerve and zone 3 the lateral plantar nerve. A screw through zone 2 compromises the medial plantar in both. Screws through zone 4 risk the lateral plantar nerve with the DePuy plate. Screws through zone 5 of the DePuy plate risk the medial calcaneal nerve. Zone 5 of the Stryker plate and Zone 6 of both are safe. There is significant risk to medial structures from laterally placed wires, drills or screws. Subtalar screws have the highest risk and have to be carefully measured and placed. The Stryker plating system is relatively safer than the DePuy perimeter plate with three safe zones out of six


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 4 - 4
1 Apr 2012
Cherry V Pillai A Siddiqui M Kumar C
Full Access

A consensus regarding management of calcaneal fractures eludes orthopaedic surgeons. While operative treatment has gained more acceptance, surgical morbidity remains high. We undertook a retrospective review of early complications and radiological outcomes following internal fixation of calcaneal fractures in our unit over 15 months. A consecutive series of 33 patients who underwent fixation of the Calcaneus was selected. Patient records, X-rays and scans were reviewed. 37 fractures in 33 patients underwent fixation. 81 % were male. Mean age at surgery was 37yrs (19 -59yrs). 35 % were operated within 1 wk of injury and 13% after 2 wks of injury. 43% were Sanders' type III, 18% type II and 13% tuberosity avulsion fractures. 63% had a reversed/zero Bohler's angle. Mean post-op Bohler's angle was 32 degrees. Overall complication rate was 32%, with a combined deep infection rate of 8%. All patients with infection were male, and 70% were smokers. 86% were above 40yrs of age (mean 47yrs). The deep infection rate for intra-articular fractures was 3% and for tuberosity avulsion fractures 40%. Majority of patients with wound complications had been operated within 7 days of injury. Males over 40yrs and smokers seem to be at most risk of wound complications. Time to surgery/delay in surgery up to 2 wks did not seem to have any adverse consequences. Complications increase with fracture complexity and avulsion fractures have highest risk of wound breakdown. Near anatomical restoration of the articular surface is possible in most


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 65 - 65
1 May 2017
Alzahrani M Cota A Alkhelaifi K Harvey E
Full Access

Background. Open reduction and internal fixation using plate osteosynthesis for midshaft clavicle fractures is often associated with hardware prominance. Although clinical studies have suggested a role for the use of thinner 2.7mm plates as a means of increasing cosmetic acceptability this still remains an area of controversy. We investigated the effect of plate size (2.7mm vs. 3.5mm), plate treatment (annealed vs. cold worked) and number of screws on the stiffness and yield point. Methods. Twenty-four synthetic clavicles were randomly divided into four treatment groups - Synthes (Synthes, Paoli, PA) 2.7mm cold-worked calcaneal reconstruction plate with six or eight bicortical screws; 3.5mm LCP reconstruction plate (RP) and 3.5mm LCP pre-contoured superior-anterior clavicle plate (PCSA). After measuring the baseline stiffness of the intact specimens, all clavicles were plated, a wedge-shaped inferior defect was created and testing performed using a cantilever-bending model. Statistical analysis was performed using one-way ANOVA with Tukey's multiple comparison test with significance set at a P value <0.05. Results. The 3.5mm RP construct was significantly stiffer than both of the 2.7mm CR constructs (P < 0.0001). The yield point for the 3.5mm PCSA construct was greater than the other three constructs (P < 0.0001), while the yield point for the 2.7mm CR plate with 6 screws and with 8 screws was higher than the 3.5mm RP construct (P = 0.0002 and P = 0.0023 respectively). The amount of displacement required to reach the yield point was highest for the 2.7mm CR plate with six screws and this was significantly higher than the values for the other three constructs. Conclusion. The 3.5mm plates demonstrated increased bending stiffness compared to the 2.7mm plates. Despite the lower resistance to bending forces, the cold worked 2.7mm plate exhibited a significantly higher yield point and required significantly more superior to inferior displacement to deform