Septic arthritis following intra-capsular penetration of the knee by external fixation devices is a complication of traction/fixation devices. This study aimed to demonstrate the capsular attachments and reflections of the distal femur to determine safe placements of wires. The attachments of the capsule to the distal femur were measured in cadaveric knees. Medially and laterally measurements were expressed as percentages related to the maximal AP diameter of the distal femur.Background:
Methods:
Potential injury to the common peroneal nerve at the level of the fibula head/neck junction during fine wire insertion in stabilization of proximal fibula, is a recognised complication. This study aims to relate the course of the common peroneal nerve to fibula head transfixion wire. Standard 1.8mm Ilizarov wires were inserted percutaneously in the fibula head of cadaveric knees. The course of the common peroneal nerve was dissected calculating wire to nerve distance.Background:
Methods:
To evaluate if, for orthopaedic trainees, additional cadaveric simulation training or standard training alone yields superior radiological and clinical outcomes in patients undergoing dynamic hip screw (DHS) fixation or hemiarthroplasty for hip fracture. This was a preliminary, pragmatic, multicentre, parallel group randomized controlled trial in nine secondary and tertiary NHS hospitals in England. Researchers were blinded to group allocation. Overall, 40 trainees in the West Midlands were eligible: 33 agreed to take part and were randomized, five withdrew after randomization, 13 were allocated cadaveric training, and 15 were allocated standard training. The intervention was an additional two-day cadaveric simulation course. The control group received standard on-the-job training. Primary outcome was implant position on the postoperative radiograph: tip-apex distance (mm) (DHS) and leg length discrepancy (mm) (hemiarthroplasty). Secondary clinical outcomes were procedure time, length of hospital stay, acute postoperative complication rate, and 12-month mortality. Procedure-specific secondary outcomes were intraoperative radiation dose (for DHS) and postoperative blood transfusion requirement (hemiarthroplasty).Aims
Methods
Ankle fracture fixation is commonly performed by junior trainees. Simulation training using cadavers may shorten the learning curve and result in a technically superior surgical performance. We undertook a preliminary, pragmatic, single-blinded, multicentre, randomized controlled trial of cadaveric simulation versus standard training. Primary outcome was fracture reduction on postoperative radiographs.Aims
Methods
The superficial anterior vasculature of the knee is variably described; most of our information comes from anatomical literature. Descriptions commonly emphasise medial-dominant genicular branches of the popliteal artery. Describing the relative contribution of medial and lateral vessels to the anastomotic network of the anterior knee may help provide grounds for selecting one of a number of popular incisions for arthrotomy. The aim of this study is to describe the relative contribution of vessels to anastomoses supplying the anterior knee.
The use of two implants to manage concomitant ipsilateral femoral
shaft and proximal femoral fractures has been indicated, but no
studies address the relationship of dynamic hip screw (DHS) side
plate screws and the intramedullary nail where failure might occur
after union. This study compares different implant configurations
in order to investigate bridging the gap between the distal DHS
and tip of the intramedullary nail. A total of 29 left synthetic femora were tested in three groups:
1) gapped short nail (GSN); 2) unicortical short nail (USN), differing
from GSN by the use of two unicortical bridging screws; and 3) bicortical
long nail (BLN), with two angled bicortical and one unicortical bridging
screws. With these findings, five matched-pairs of cadaveric femora
were tested in two groups: 1) unicortical long nail (ULN), with
a longer nail than USN and three bridging unicortical screws; and
2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally
rotated 90°/sec until failure.Objectives
Methods
Fractures and nonunions of the proximal humerus are increasingly treated by open reduction and internal fixation. The extended deltopectoral approach remains the most widely used for this purpose. However, it provides only limited exposure of the lateral and posterior aspects of the proximal humerus. We have previously described the alternative extended deltoid-splitting approach. In this paper we outline variations and extensions of this technique that we have developed in the management of further patients with these fractures.