Introduction. Robotic-assisted hip arthroplasty helps acetabular preparation and implantation with the assistance of a robotic arm. A computed tomography (CT)-based navigation system is also helpful for acetabular preparation and implantation, however, there is no report to compare these methods. The purpose of this study is to compare the acetabular cup position between the assistance of the robotic arm and the
Introduction.
Objectives. Few reports were shown about the position of the cup in total hip arthroplasty (THA) with
Objectives. Few reports were shown about the position of the cup in total hip arthroplasty (THA) with
Background.
Objectives. The setting angle of the cup is important for achieving the stability and avoiding the dislocation after total hip arthroplasty (THA). It is difficult to set the cup at correct angle in minimally invasive THA by modified Watson-Jones approach. So we use
Objectives. Many reports were shown about the angle of the cup in total hip arthroplasty (THA) with
The ligament balance as well as the alignment is essential for successful total knee arthroplasty (TKA). However it is usually assessed and adjusted only at 0? and 90?. In order to evaluate the ligament balance at the other angles we have used a navigation system. Twenty-one patients underwent posterior stabilised mobile bearing TKA using a
Introduction. We have used
Introduction. Deformity after femoral osteotomy varies between patients. Some researchers reported good results when using cemented stems for the hips after femoral osteotomy, but there are many disadvantages that obstruct ideal fixation using cemented stems. Therefore, we developed cementless custom-made stems and inserted those using a computed tomography (CT) –based navigation system. Methods. Eighteen dysplastic hips of 15 patients after intertrochanteric osteotomy were investigated in the present study. Individual computed tomography data were used to manufacture cementless custom-made femoral stems out of Ti-6Al-4V. The proximal 1/3 of each stem was coated using porous coating covered with hydroxyapatite coating. The stems were inserted using a
Introduction:. Since2007, we have used
Introduction. Since2007, we have used
Introduction. Orientation of the acetabular component in total hip arthroplasty has been shown to influence component wear, stability, and impingement. Freehand placement of the component can lead to widely variable radiographic outcomes. Accurate abduction, in particular, can be difficult in the lateral decubitus position due to limited ability to appreciate and control positional obliquity of the pelvis. A
The occurrence of impingement can lead to instability, accelerated wear, and unexplained pain after THA. While implant and bony impingement were widely investigated, importance of soft tissue impingement was unclear. In the THA through posterior approach, it is known that posterior soft tissue repair can decrease the risk of dislocation. However, it is not known whether anterior soft tissue impingement by anterior hip capsule will influence hip ROM. The purpose of this study is to quantitatively measure the effect of anterior capsule resection on hip ROM in vivo during posterior approach THA using hip navigation system. From June 2011, 26 hips (25 patients) that underwent primary THA using Stryker
Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires through evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. As you know Sir John Charnley is one of the first orthopaedic surgeons to address the issue of soft-tissue tensioning (STT) in the THA. Moreover leg-length discrepancy (LLD) after THA can pose a substantial problem for the orthopaedic surgeon. Such discrepancy has been associated with complications including nerve palsy, low back pain, and abnormal gait. The objective of this study is to assess hip instability of three different FOs in same patient undergoing THA during an operation. We performed 70 patients who had undergone unilateral THA using CT based navigation system at a single institution for advanced osteoarthoritis from May 2013 to May 2014. We used postero-lateral approach in all patients. After cup and stem implantation, we assessed soft tissue tensioning in THA during operation. Trial necks were categorized into one of three groups: standard femoral offset (sFO), high femoral offset (hFO, +4mm compared to sFO) and extensive high femoral offset (ehFO, +8 mm compared to sFO). We measured distance of lift-off about each of three femoral necks using CT based navigation system and a force gauge with hip flexed at 0 degrees and 30 degrees under a traction of lower extremity. Traction force was 40% of body weight.Purpose
Methods
The optimal positioning of the acetabular component is a relevant prognostic factor in total hip arthroplasty (THA). Because of substantial errors of manual technique in cup placement even with experienced surgeon, computer aided navigation system has been developed in recent years. However, existence of the hardware around acetabulum likely deteriorates the accuracy of the navigation system, namely in revision THA case and postoperative status of pelvic fracture. Here we report a case who we successfully performed THA using CT based navigation system although there were multiple hardware around acetabulum due to osteosynthesis for the previous pelvic fracture. A forty-one years old man presented with intolerable hip pain with severe radiographic osteoarthritic findings in left hip joint. He had sustained left pelvic fracture and posterior hip dislocation due to traffic accident and undergone osteosynthesis using multiple plates and screws when he was forty years old. However, progressive collapsing of femoral head and acetabulum occurred. Then, we indicated THA for his situation and planned to apply the CT based navigation system (Stryker CT based hip Ver.1.1 softwear and Cart II system). Preoperative workup revealed incomplete union of posterior and superior acetabular wall and we had to retain plates and screws for the stable fixation of acetabular cup. The existence of the hardware made it complicated to perform three dimensional planning and templating. Meticulous surface editing of pelvis to exclude the metal artifact and fibrocartilagenous tissue was needed to achieve accurate surface registration. In the operation room, we had to use unusual way of registration to complete two steps of registration. In the first step (roughly matching between patient's physical pelvic surface and edited pelvic surface in work station using corresponding 5 points), we utilized head of screw and hole of the plate which we could easily identify intraoperatively, in addition to ASIS and innominate groove. In the second step (strict matching using more than 30 points of pelvic surface), we had to identify the pelvic bony surface, as excluding the metal surface and fibrocartilagenous tissue such as fracture callus. These efforts enabled us to accomplish substantial accuracy of registration with RMS of 0.5 mm. Final cup orientation at the end of surgery was 41° of inclination and 25° of anteversion. Postoperative CT scan revealed that cup placement angle was 40° of inclination and 25° of anteversion, almost identical with intraoperative value.Objective
Case presentation
We have used CT-based total hip navigation system from 2003, to set the acetabular socket in optimal position. At first, we had used CT-based land-mark matching system. It needs matching procedure during surgery, touching paired points in surgical exposure. From 2006, we started to use new navigation system, called CT-based fluoroscopy-matching system, which was developed by BrainLAB Company (Vector-vision 2.7.1., 3.5.1.). For this new system, pre-surgical image matching procedure is need. Fluoroscopic images with 2 different directions must be taken in operation room. Then fluoroscopic images and CT reconstructive images were matched in computer with special program. Matching procedure was done before surgical incision. We compared the advantage of these two systems about technical problem, radiation exposure, time need for procedure, and accuracy. And then we discussed how to use these two different systems for THA patients. Accuracy was compared for 241 THA patients using these navigation systems. 152 cases were with CT-based land-mark matching system and 89 patients with CT-based fluoroscopy matching system. Final verification angle of acetabular socket setting in navigation during surgery was recorded for each case. The operative angle, which is referred from Murray, is used to show the socket setting angle (inclination and anteversion) in these navigation systems. Post-operative CT scan was taken to evaluate the actual socket setting angle. The values between verification angle during surgery and post-operative CT measured angle were calculated and compared statistically. Results were followed.
For ordinary THA cases with skilled-doctor, CT-based land-mark matching system is useful, because this system is very convenient and needs only extra 10 minutes during surgery. For severe deformed cases with all kind doctors, CT-based fluoroscopy matching system is useful, because this system showed high accuracy even for severe deformed cases. Before surgical incision, fluoroscopic matching procedure has finished. This system needs no extra time after surgery starts.
Component positioning in total hip arthroplasty (THA) is critical to achieve optimal patient outcomes. Recent literature has shown acetabular component positioning may be inaccurate using traditional techniques. Robotic-assisted THA is a recent platform introduced to decrease the risk of malpositioned components. However, to date, a paucity of data is available comparing the intra-operative component position generated by the navigation system to post-operative radiographs. The purpose of this study was to compare the component position measurements of a navigation system, used during robotic-assisted THA, to component position measurements obtained on post-operative radiographs.Background
Purpose
The purpose of this study was to evaluate in vivo fit and fill analysis of tapered wedge-type stem in total hip arthroplasty (THA) with computed tomography (CT)-based navigation system. 100 THAs were all performed through the posterolateral approach, with patients in the lateral decubitus position. Each cohort of 50 consecutive primary cementless THAs with was compared with and without
Introduction. Acetabular revision surgery is challenging due to severe bone defects. Burch-Schneider anti-protrusion cages (BS cage: Zimmer-Biomet) is one of the options for acetabular revision, however higher dislocation rate was reported. A computed tomography (CT)-based navigation system indicates us the planned direction for implantation of a cemented acetabular cup during surgery. A large diameter femoral head is also expected to reduce the dislocation rate. The purpose of this study is to investigate short-term results of BS cage in acetabular revision surgery combined with the