Advertisement for orthosearch.org.uk
Results 1 - 20 of 385
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 173 - 176
1 Feb 2015
Omar M Ettinger M Reichling M Petri M Guenther D Gehrke T Krettek C Mommsen P

The aim of this study was to assess the role of synovial C-reactive protein (CRP) in the diagnosis of chronic periprosthetic hip infection. We prospectively collected synovial fluid from 89 patients undergoing revision hip arthroplasty and measured synovial CRP, serum CRP, erythrocyte sedimentation rate (ESR), synovial white blood cell (WBC) count and synovial percentages of polymorphonuclear neutrophils (PMN). Patients were classified as septic or aseptic by means of clinical, microbiological, serum and synovial fluid findings. The high viscosity of the synovial fluid precluded the analyses in nine patients permitting the results in 80 patients to be studied. There was a significant difference in synovial CRP levels between the septic (n = 21) and the aseptic (n = 59) cohort. According to the receiver operating characteristic curve, a synovial CRP threshold of 2.5 mg/l had a sensitivity of 95.5% and specificity of 93.3%. The area under the curve was 0.96. Compared with serum CRP and ESR, synovial CRP showed a high diagnostic value. According to these preliminary results, synovial CRP may be a useful parameter in diagnosing chronic periprosthetic hip infection. Cite this article: Bone Joint J 2015; 97-B:173–6


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 411 - 418
1 Mar 2013
Nakamura T Grimer RJ Gaston CL Watanuki M Sudo A Jeys L

The aim of this study was to determine whether the level of circulating C-reactive protein (CRP) before treatment predicted overall disease-specific survival and local tumour control in patients with a sarcoma of bone. We retrospectively reviewed 318 patients who presented with a primary sarcoma of bone between 2003 and 2010. Those who presented with metastases and/or local recurrence were excluded. Elevated CRP levels were seen in 84 patients before treatment; these patients had a poorer disease-specific survival (57% at five years) than patients with a normal CRP (79% at five years) (p < 0.0001). They were also less likely to be free of recurrence (71% at five years) than patients with a normal CRP (79% at five years) (p = 0.04). Multivariate analysis showed the pre-operative CRP level to be an independent predictor of survival and local control. Patients with a Ewing’s sarcoma or chondrosarcoma who had an elevated CRP before their treatment started had a significantly poorer disease-specific survival than patients with a normal CRP (p = 0.02 and p < 0.0001, respectively). Patients with a conventional osteosarcoma and a raised CRP were at an increased risk of poorer local control. We recommend that CRP levels are measured routinely in patients with a suspected sarcoma of bone as a further prognostic indicator of survival. Cite this article: Bone Joint J 2013;95-B:411–18


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1482 - 1486
1 Nov 2018
Akgün D Müller M Perka C Winkler T

Aims. The aim of this study was to determine the prevalence and characteristics of C-reactive protein (CRP)-negative prosthetic joint infection (PJI) and evaluate the influence of the type of infecting organism on the CRP level. Patients and Methods. A retrospective analysis of all PJIs affecting the hip or knee that were diagnosed in our institution between March 2013 and December 2016 was performed. A total of 215 patients were included. Their mean age was 71 years (. sd. 11) and there were 118 women (55%). The median serum CRP levels were calculated for various species of organism and for patients with acute postoperative, acute haematogenous, and chronic infections. These were compared using the Kruskal–Wallis test, adjusting for multiple comparisons with Dunn’s test. The correlation between the number of positive cultures and serum CRP levels was estimated using Spearman correlation coefficient. Results. Preoperative CRP levels were normal (< 10 mg/l) in 77 patients (35.8%) with positive cultures. Low-virulent organisms were isolated in 66 PJIs (85.7%) with normal CRP levels. When grouping organisms by species, patients with an infection caused by Propionibacterium spp., coagulase-negative staphylococci (CNS), and Enterococcus faecalis had significantly lower median serum CRP levels (5.4 mg/l, 12.2 mg/l, and 23.7 mg/l, respectively), compared with those with infections caused by Staphylococcus aureus and Streptococcus spp. (194 mg/l and 89.3 mg/l, respectively; p < 0.001). Those with a chronic PJI had statistically lower median serum CRP levels (10.6 mg/l) than those with acute postoperative and acute haematogenous infections (83.7 mg/l and 149.4 mg/l, respectively; p < 0.001). There was a significant correlation between the number of positive cultures and serum CRP levels (Spearman correlation coefficient, 0.456; p < 0.001). Conclusion. The CRP level alone is not accurate as a screening tool for PJI and may yield high false-negative rates, especially if the causative organism has low virulence. Aspiration of the joint should be used for the diagnosis of PJI in patients with a chronic painful arthroplasty, irrespective of CRP level. Cite this article: Bone Joint J 2018;100-B:1482–86


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 874 - 878
1 Jul 2008
Fink B Makowiak C Fuerst M Berger I Schäfer P Frommelt L

We analysed the serum C-reactive protein level, synovial fluid obtained by joint aspiration and five synovial biopsies from 145 knee replacements prior to revision to assess the value of these parameters in diagnosing late peri-prosthetic infection. Five further synovial biopsies were used for histological analysis. Samples were also obtained during the revision and incubated and analysed in an identical manner for 14 days. A total of 40 total knee replacements were found to be infected (prevalence 27.6%). The aspiration technique had a sensitivity of 72.5% (95% confidence interval (CI) 58.7 to 86.3), a specificity of 95.2% (95% CI 91.2 to 99.2), a positive predictive value of 85.3% (95% CI 73.4 to 100), a negative predictive value of 90.1% (95% CI 84.5 to 95.7) and an accuracy of 89%. The biopsy technique had a sensitivity of 100%, a specificity of 98.1% (95% CI 95.5 to 100), a positive predictive value of 95.2% (95% CI 88.8 to 100), a negative predictive value of 100% and an accuracy of 98.6%. C-reactive protein with a cut-off-point of 13.5 mg/l had a sensitivity of 72.5% (95% CI 58.7 to 86.3), a specificity of 80.9% (95% CI 73.4 to 88.4), a positive predictive value of 59.2% (95% CI 45.4 to 73.0), a negative predictive value of 88.5% (95% 81.0 to 96.0 CI) and an accuracy of 78.1%. We found that biopsy was superior to joint aspiration and C-reactive protein in the diagnosis of late peri-prosthetic infection of total knee replacements


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 638 - 641
1 Aug 1989
Sanzen L Carlsson A

In 50 patients with non-infected total hip arthroplasties (THA), 233 C-reactive protein (CRP) values were obtained over a three-year period. Six of these 50 patients occasionally had CRP values of over 20 mg/l. The erythrocyte sedimentation rate (ESR) and CRP concentration were measured in 23 patients with deep infections of THA before revision. In 11 patients the infections were caused by coagulase-negative staphylococci. CRP exceeded 20 mg/l in 18 patients and the ESR was more than 30 mm/hr in 14. In only one infected patient were both CRP and ESR below these levels. All of 33 patients with non-septic loosening had CRP less than 20 mg/l and ESR less than 30 mm/hr before revision. C-reactive protein seems to be a valuable supplement to the ESR in the monitoring of infection after THA


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 128 - 128
1 Mar 2009
Boettner F Erren M Wegner A Becker K Winkelmann W Goetze C
Full Access

78 patients (41 male and 37 female) with a revision total knee or hip arthroplasty were enrolled in this prospective study to evaluate the role of new laboratory markers in the diagnostic of deep implant infection. The average age at the time of surgery was 64 years. Based on intraoperative cultures, 21 patients had a septic and 57 patients had an aseptic revision total joint arthroplasty. White blood cell counts, erythrocyte sedimentation rate, C-reactive protein levels, interleukin-6, procalcito-nin and TNF-alpha were measured in preoperative blood samples. Diagnostic cut of values were determined by Receiver Operating Characteristic curve analysis. If patients with rheumatoid arthritis and other concomitant infections are excluded the C-reactive protein (> 3.2md/dl) and interleukin 6 (> 12 pg/ml) have the highest sensitivity (0.95). Interleukin 6 is less specific than the C-reactive protein (0.87 versus 0.96). Combining C-reactive protein and interleukin identifies all patients with deep implant infection. Procalcitonin (> 0.3 ng/ml) and TNF-alpha (> 40 ng/ml) are very specific (0.98 versus 0.94)) but have a low sensitivity (0.33 versus 0.43). The combination of C-reactive protein and interleu-kin 6 is an excellent screening tests for deep implant infection. Highly specific marker like procalcitoninn as well as preoperative joint aspiration might be useful to identify patients with true positive CRP and/or interleu-kin 6 levels


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 523 - 524
1 Jul 1992
Choudhry R Rice R Triffitt P Harper W Gregg P

We studied the changes in plasma viscosity and C-reactive protein to establish normal values after total hip or knee arthroplasty. Viscosity decreased from 1.68 (+/- 0.017) to 1.57 (+/- 0.014) on the first postoperative day and thereafter rose to 1.60 (+/- 0.019), 1.75 (+/- 0.015), and 1.74 (+/- 0.011) on the third, seventh and fourteenth days respectively. Six to eight weeks after operation it had returned to pre-operative levels. A viscosity above the upper limit of the laboratory range, obtained more than two months after operation, may be considered as abnormal. The C-reactive protein level increased significantly on the first postoperative day and then decreased from a peak on the second day, attaining nearly normal levels at six to eight weeks after operation. It may be a more sensitive indicator of deep postoperative infection than plasma viscosity


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 85 - 85
1 Dec 2015
Gamba C Diez J Prieto D Fabrego A Verdie L Perez F Canovas C
Full Access

Successfully treatment of acute shoulder arthroplasty infections strongly depends on the timing of treatment. The objective of this study is to determine the normalization curve of C-reactive protein (CRP) after shoulder arthroplasty. Prospective study including 63 patients undergoing shoulder arthroplasty (46 reverse shoulder arthroplasty (RSA) and 17 total shoulder (TSA)). Mean age 74.1 years old. 25 cuff deficient shoulders, 14 acute fractures, 19 primary gleno-humeral arthritis and 5 fracture sequel were included. Blood samples to determine CRP were obtained before surgery the day of surgery, 24 and 48 hours after surgery and then 6, 8 and 14 days after surgery (data of blood samples was determined based on a previous limited study). Co-morbidities that could interfere CRP were also recorded. Normal value of CRP before surgery (mean 1.28) slightly increases 24 hours after surgery (mean 3.92), reach maximum value at 48 hours after surgery (mean 6.91) and then slowly decreases to normalize at 14 days (6th day mean 3.80, 8th day 2.33 and 14th day 1.08). Normalization curve is not affected by age, diagnosis or type of arthroplasty. CRP after shoulder arthroplasty reaches maximum value at 48h and then slowly decreases to become normal at 14 days. Any deviation from this normalization curve may help in diagnosis and early treatment of acute shoulder arthroplasty infections


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 206 - 206
1 Sep 2012
Cashman J MacKenzie J Parvizi J
Full Access

Background. The diagnosis of Periprosthetic Joint Infection (PJI) is a considerable challenge in total joint arthroplasty. The mainstay for diagnosis of PJI is a combination of serological markers, including C-reactive protein (CRP), along with joint aspirate for white cell count, differential and culture. The aim of this study was to examine the use of synovial fluid CRP in the diagnosis of PJI. Material & Methods. Synovial fluid samples were collected prospectively from patients undergoing primary and revision knee arthroplasty. Samples were assessed for CRP, cell count and differential. Three groups were analyzed; those undergoing primary knee arthroplasty, aseptic knee arthroplasties and infected arthroplasties. Demographic data, along with associated medical co-morbidities, were collected,. Statistical analysis was performed. Synovial fluid CRP was correlated with serum CRP values. Sensitivity and specificity were calculated. Results. 50 synovial fluid samples were collected from 50 patients. Synovial fluid CRP was 0.3 +/− 0.4 in native knees, 0.2 +/− 0.5 in aseptic knee arthroplasties, 4.3+/−4.1 in patients with infected knee arthroplasties. Synovial fluid CRP was significantly higher in septic total knee arthroplasties by comparison to both aseptic total knees (p< 0.001) and native knees (p=0.006). The specificity was 100% and the sensitivity was 89% at a CRP of 1. Conclusion. While this is preliminary data, synovial fluid CRP was found to be significantly elevated in patients with infected total knee arthroplasties. This test is easily performed under routine hospital laboratory conditions without specific, expensive assays. We believe synovial CRP assay holds great promise as a new, potentially low-cost, diagnostic marker for PJI


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 909 - 911
1 Sep 1998
White J Kelly M Dunsmuir R

Our study has determined the response of C-reactive protein (CRP) after total knee replacement (TKR). The peak level occurs on the second postoperative day and is significantly greater than that after total hip replacement (THR). The level returns to normal at similar times after both procedures. The physiological response to TKR as measured by the area under the CRP/ time curve is significantly greater than that after THR. Rising CRP levels after the third postoperative day may indicate a complication of surgery such as infection


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 127 - 127
1 Jul 2020
Shefelbine L Bouchard M Bompadre V
Full Access

C-reactive protein (CRP) level is used at our tertiary paediatric hospital in the diagnosis, management, and discharge evaluation of paediatric septic arthritis patients. The purpose of this study was to evaluate the efficacy of a discharge criterion of CRP less than 2 mg/dL for patients with septic arthritis in preventing reoperation and readmission. We also aimed to identify other risk factors of treatment failure. Patients diagnosed with septic arthritis between January 1, 2007 and December 31, 2017 were reviewed retrospectively. The diagnosis of septic arthritis was made based on clinical presentation, laboratory results and the finding of purulent material on joint aspiration or the isolation of a bacterial pathogen from joint fluid or tissue. Bivariate tests of associations between patient or infection factors and readmission and reoperation were performed. Quantitative variables were analyzed using Mann-Whitney tests and categorical variables were analyzed using Chi-square tests. One hundred eighty-three children were included in the study. Seven (3.8%) were readmitted after hospital discharge for further management, including additional advanced imaging, and IV antibiotics. Six (85.7%) of the readmitted patients underwent reoperation. Mean CRP values on presentation were similar between the two groups: 8.26 mg/dL (± 7.87) in the single-admission group and 7.94 mg/dL (± 11.26) in the readmission group (p = 0.430). Mean CRP on discharge for single-admission patients was 1.71 mg/dL (± 1.07), while it was 1.96 mg/dL (± 1.19) for the readmission group (p = 0.664), with a range of < 0 .8 to 6.5 mg/dL and a median of 1.5 mg/dL for the two groups combined. A total of 48 children (25.9%) had CRP values greater than the recommended 2 mg/dL at discharge, though only three of these patients (6.2%) were later readmitted. The only common variable in the readmitted children was either a negative culture result at time of discharge or atypical causative bacteria. CRP values are useful in monitoring treatment efficacy but not as reliable as a discharge criterion to prevent readmission or reoperation in children with septic arthritis. We recommend determining discharge readiness on the basis of clinical improvement and downtrending CRP values. There was a higher risk of readmission in children with an atypical causative bacteria and when culture results were negative at discharge. Close monitoring of these patients after discharge is suggested to identify signs of persistent infection


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 431 - 433
1 May 1996
Niskanen RO Korkala O Pammo H

Any operation induces an elevation in the level of serum C-reactive protein (CRP). After hip and knee arthroplasty the maximal values are seen on the second and third postoperative days, after which the CRP decreases rapidly. There is no difference between patients with cemented or uncemented prostheses. Major postoperative complications may cause a further increase in CRP levels at one and two weeks


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1151 - 1154
1 Nov 2003
Sugimori K Kawaguchi Y Morita M Kitajima I Kimura T

We measured the serum concentration of C-reactive protein (CRP) by a high-sensitive method in patients with lumbar disc herniation. There were 48 patients in the study group and 53 normal controls. The level and type of herniation were evaluated. The clinical data including the neurological findings, the angle of straight leg raising and post-operative recovery as measured by the Japanese Orthopaedic Association (JOA) score, were recorded. The high-sensitive CRP (hs-CRP) was measured by an ultrasensitive latex-enhanced immunoassay. The mean hs-CRP concentration was 0.056 ± 0.076 mg/dl in the patient group and 0.017 ± 0.021 mg/dl in the control group. The difference was statistically significant (p = 0.006). There was no other correlation between the hs-CRP concentration and the level and type of herniation, or the pre-operative clinical data. A positive correlation was found between the concentration of hs-CRP before operation and the JOA score after. Those with a higher concentration of hs-CRP before operation showed a poorer recovery after. The significantly high concentration of serum hs-CRP might indicate a systemic inflammatory response to impingement of the nerve root caused by disc herniation and might be a predictor of recovery after operation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 53 - 53
1 Dec 2019
Stone W Gray CF Parvataneni HK Al-Rashid M Vlasak RG Prieto H
Full Access

Aim. Diagnosing periprosthetic joint infection after total joint arthroplasty is often challenging. The alpha defensin test has been recently reported as a promising diagnostic test for periprosthetic joint infection. The goal of this study was to determine the diagnostic accuracy of alpha defensin testing. Method. One hundred and eighty-three synovial alpha defensin and synovial fluid C-reactive protein (CRP) tests performed in 183 patients undergoing evaluation for periprosthetic joint infection were reviewed. Results were compared with the Musculoskeletal Infection Society (MSIS) criteria for periprosthetic joint infection. Results. Alpha defensin tests were performed prior to surgical treatment for infection, and 37 of these patients who had these tests were diagnosed by MSIS criteria as having infections. Among this group, the alpha defensin test had a sensitivity of 81.1% (95% confidence interval [CI], 64.8% to 92.0%) and a specificity of 95.9% (95% CI, 91.3% to 98.5%). There were 6 false-positive results, 4 of which were associated with metallosis. There were 7 false negatives, all of which were associated with either draining sinuses (n = 3) or low-virulence organisms (n = 4). A combined analysis of alpha defensin and synovial fluid CRP tests was performed in which a positive result was represented by a positive alpha defensin test and a positive synovial fluid CRP test (n = 28). Among this group, the sensitivity was calculated to be 73.0% (95% CI, 55.9% to 86.2%) and the specificity was calculated to be 99.3% (95% CI, 96.2% to 99.9%). An additional combined analysis was performed where a positive result was represented by a positive alpha defensin test or positive synovial fluid CRP test (n = 64). Among this group, the sensitivity was calculated tobe91.9%(95%CI, 78.1%to98.3%) andthe specificitywas calculated tobe79.5%(95%CI, 72.0%to85.7%). Conclusions. Alpha defensin in combination with synovial fluid CRP demonstrates very high sensitivity for diagnosing periprosthetic joint infection, but may yield false-positive results in the presence of metallosis or false-negative results in the presence of low-virulence organisms. When both alpha defensin and synovial fluid CRP tests are positive, there is a very high specificity for diagnosing periprosthetic joint infection


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 615 - 617
1 Jul 1990
Kallio P Michelsson J Lalla M Holm T

Serial serum C-reactive protein (CRP) measurements were made, for three weeks, in 42 consecutive patients with solitary tibial fractures. The CRP response was related to the treatment: lower values were observed in 27 patients treated conservatively than in 15 operated patients. Open reduction and plating resulted in a greater response than closed intramedullary nailing. The timing of the CRP response was related to the timing of the treatment: the highest values were usually recorded two days after admission or operation. The timing of the operation did not affect the degree of CRP response. Neither the site, nor the type of fracture, nor the age of the patient played any role. Awareness of these natural CRP responses after fractures may help in the diagnosis of early post-traumatic and postoperative complications, especially infections


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 104 - 104
1 Dec 2015
De Vecchi E Villa F Agrappi S Toscano M Drago L
Full Access

Culture examination is still considered the gold standard for diagnosis of bone and joint infections, including prosthetic ones, even if in up to 20–30% of cases, particularly prosthetic joint infections, it fails to yield microbial growth. To overcome this limitation, determination of markers of inflammation and or infection directly in joint fluid has been proposed. Aim of this study was to evaluate the applicability of measurement of lecukocyte esterase (LE), C-reactive protein (CRP) and glucose in synovial fluid for diagnosis of bone and joint infections. Synovial fluids from 80 patients were aseptically collected and sent to laboratory for microbiological cultures. After centrifugation at 3000 rpm for 10 minutes, pellet was used for cultures, while the surnatant was used for determination of LE, CRP and glucose. LE and glucose were evaluated by means of enzymatic colorimetric strips developed for urinanalysis. One drop of synovial fluid was placed on the LE and on the glucose pads and the results were read after about 120 seconds. A LE test graded + or ++, and a glucose test equal to trace or negative were considered suggestive for infection. CRP was measured by an automated turbidimetric method. On the basis of clinical findings, microbiological, haematological and histological analyses patients were retrospectively divided into 2 groups. Group 1 comprised 19 infected patients (12 males, 7 females age: 70.6 ± 10.3 yrs, range: 47 – 88 yrs) while Group 2 included 61 aseptic patients (32 males and 29 females, age: 61.5 ± 16.3 yrs, range: 15 – 84). Sensitivity of the three tests was 89.5%. 84% and 73,7% for LE, CRP and glucose, respectively. Specificity was 98.4%, 88.5% and 70% for LE, CRP and glucose, respectively. Positive and negative predictive values were 94.4% and 96.8% for LE, 69.6% and 94.6% for CRP and 77.8% and 89.6% for glucose test. When LE was combined with CRP, sensitivity increased to 94.7%, while no differences were observed for LE combined with glucose. Leukocyte esterase has proven to be a rapid, simple and inexpensive test to rule in or out bone and joint infections. Combination of its measurement with that of CRP increased sensitivity. In conclusion, the combination of leukocyte esterase and CRP may represent a simple and useful tool for diagnosis of bone and joint infections


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 10 - 10
1 Mar 2005
Nordsletten L Bergum H
Full Access

Over 13 months we prospectively monitored C-Reactive Protein (CRP) to assess surgical site infection (SSI) in 148 patients undergoing hip arthroplasty, including 34 hemiprostheses for femoral neck fracture, 35 hemiprostheses for osteosynthesis failure, 17 primary total hip arthroplasties (THAs) and 62 revisions of hemi-arthroplasty or THA. Ten patients who had probably had interaction with CRP were included. In four out of seven patients with SSI, CRP values peaked three days after the operation, compared to eight out of 131 without SSI (p =0.0001). This gives a 60% sensitivity for detecting SSI by the CRP curve, with a specificity of 94%. The positive predictive value was 33%, and the negative predictive value 98%. Previous studies have established the normal CRP curve after major joint replacement surgery. This study shows that a peak in CRP after day three may indicate SSI, or point to other deep infections such as pneumonia


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 141 - 141
2 Jan 2024
Ruiz-Fernández C Eldjoudi D Gonzalez-Rodríguez M Barreal A Farrag Y Mobasheri A Pino J Sakai D Gualillo O
Full Access

Monomeric C reactive protein (mCRP) presents important proinflammatory effects in endothelial cells, leukocytes, or chondrocytes. However, CRP in its pentameric form exhibits weak anti-inflammatory activity. It is used as a biomarker to follow severity and progression in infectious or inflammatory diseases, such as intervertebral disc degeneration (IVDD). This work assesses for the first time the mCRP effects in human intervertebral disc cells, trying to verify the pathophysiological relevance and mechanism of action of mCRP in the etiology and progression of IVD degeneration.

We demonstrated that mCRP induces the expression of multiple proinflammatory and catabolic factors, like nitric oxide synthase 2 (NOS2), cyclooxygenase 2 (COX2), matrix metalloproteinase 13 (MMP13), vascular cell adhesion molecule 1 (VCAM1), interleukin (IL)-6, IL-8, and lipocalin 2 (LCN2), in human annulus fibrosus (AF) and nucleus pulposus (NP) cells. We also showed that nuclear factor-κβ (NF-κβ), extracellular signal-regulated kinase 1/2 (ERK1/2), and phosphoinositide 3-kinase (PI3K) are at play in the intracellular signaling of mCRP.

Our results indicate that the effect of mCRP is persistent and sustained, regardless of the proinflammatory environment, as it was similar in healthy and degenerative human primary AF cells. This is the first article that demonstrates the localization of mCRP in intravertebral disc cells of the AF and NP and that provides evidence for the functional activity of mCRP in healthy and degenerative human AF and NP disc cells.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_9 | Pages 27 - 27
1 Sep 2019
van den Berg R Enthoven W de Schepper E Luijsterburg P Oei E Bierma-Zeinstra S Koes B
Full Access

Background. The majority of adults will experience an episode of low back pain during their life. Patients with non-specific low back pain and lumbar disc degeneration (LDD) may experience spinal pain and morning stiffness because of a comparable inflammatory process as in patients with osteoarthritis of the knee and/or hip. Therefore, this study assessed the association between spinal morning stiffness, LDD and systemic inflammation in middle aged and elderly patients with low back pain. Methods. This cross-sectional study used the baseline data of the BACE study, including patients aged ≥55 years visiting a general practitioner with a new episode of back pain. The association between spinal morning stiffness, the radiographic features of lumbar disc degeneration and systemic inflammation measured with serum C-reactive protein was assessed with multivariable logistic regression models. Results. At baseline, a total of 661 back pain patients were included. Mean age was 66 years (SD 8), 416 (63%) reported spinal morning stiffness and 108 (16%) showed signs of systemic inflammation measured with CRP. Both LDD definitions were significantly associated with spinal morning stiffness (osteophytes OR=1.5 95% CI 1.1–2.1, narrowing OR=1.7 95% CI 1.2–2.4) and spinal morning stiffness >30 minutes (osteophytes OR=1.9 95% CI 1.2–3.0, narrowing OR=3.0 95% CI 1.7–5.2) For severity of disc space narrowing we found a clear dose response relationship with spinal morning stiffness. We found no associations between spinal morning stiffness and the features of LDD with systemic inflammation. Conclusions. This study demonstrated an association between the presence and duration of spinal morning stiffness and radiographic LDD features. No conflicts of interest. No funding obtained


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 315 - 316
1 May 2010
Yuksel H Aksahin E Muratli H Yagmurlu M Celebi L Bicimoglu A
Full Access

Aim: In patients without infections following primary total hip (PTHA) and knee (PTKA) arthroplasty, the natural course of C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) were evaluated. The effects of gender, anesthesia type, cementing, and tourniquet use on the natural course of CRP and ESR were determined. Understanding the natural course of plasma ESR and CRP is helpful in terms of the diagnosis and follow-up of infections, especially in the early postoperative period. Methods: A total of 82 patients with normal preoperative CRP and ESR, both in accordance with gender and age; without any chronic condition, infection, or inflammatory disease; and with no intra–and post-operative complications were included. PTHA was performed on 38 (Groups I–II) and PTKA on 44 patients (Groups III-IV). CRP and ESR measurements were performed on the 1st preoperative day; 1st, 2nd, 3rd, 5th, 7th, 14th, and 21st postoperative days; and the 1st, 2nd, 3rd, 6th, 9th, and 12th months. CRP measurements were performed with the nephelometric (Dade Behring S.p.A., Italy) and quantitative Methods: Westergren method was used for ESR measurements. The PTHA group was further classified as femoral component fixed with (Group I; 28 patients) and with-out cement (Group II; 10 patients), while PTKA as with (Group III; 32 patients) and without tourniquet (Group IV; 12 patients). Furthermore, epidural (Group IIIa) and general anesthesia (Group IIIb), and gender differences (Group Ia; female and Group Ib; male) were compared. Wilcoxon test, paired-t test, Students’-t test, ANOVA, and chi-square tests were used for statistical analysis. Results: After the operation, separate peak CRP and ESR levels of each patient and days of reaching peak and normalization were evaluated. When the mean of peak CRP levels were compared, groups III and IV had significantly higher levels with regard to groups I and II (p=0.037), However, the days of reaching peak levels were statistically similar between PTHA and PTKA groups (p=0.245). The same comparison was repeated for the mean of peak ESR levels, the results were similar (p=0.547). In cemented PTHA, CRP normalized earlier than cementless PTHA and PTKA (p=0.035) and ESR also normalized earlier, but this was not significant (p= 0.074). Among groups comparing gender and anesthesia type, mean values of CRP and ESR peaks, distribution of these two levels on the days controlled, and days of reaching peaks and normalization were statistically similar (p> 0.05). Conclusions: In the PTKA group, the mean CRP peak was higher than PTHA. CRP levels normalized earlier in cemented PTHA cases. Anesthesia type, gender differences, and use of tourniquet in PTKA did not affect the course of CRP and ESR following arthroplasty