Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 40 - 40
1 Aug 2018
Chen W
Full Access

The purpose of this study was to evaluate the functional and oncological outcome of recycled autograft reconstruction after a wide excision for primary malignant bone tumor around the hip.

From 1998 to 2015, 67 patients with a primary malignant bone tumor involving proximal femur or periacetabular zone (P2) were included. There were 36 males and 31 females with a mean age of 34 years (13 to 58). Of these, 29 patients had grade I or II chondrosarcoma, 28 high-grade osteosarcoma, 6 Ewing's sarcoma and 4 undifferentiated pleomorphic sarcoma. Enneking stage of all 67 patients was stage II. Of the resection classification, proximal femur resection was performed in 29 patients, P1+P2 in 15, P2+P3 in 14, P1+P2+P3 in 4, P2 only in 4, and P2+proximal femur in 1. Extracorporeally irradiated recycled autograft and liquid nitrogen frozen autograft were performed in 44 and 23 patients, respectively.

At a mean follow-up of 98 months (10 to 239), 48 patients (72%) were continuously disease-free, 12 (18%) died of disease and 7 (10%) were alive with disease. The tumors of these patients who had died of disease were usually located in pelvic bones (10/12). Of these 37 patients with pelvic tumors, 7 patients (22%) had local recurrence, four of them received external hemipelvectomy. Other complications included hip dislocation in 2 patients, nerve injury in 2 and deep infection in 2. However, the above complications were rarely occurred in the patients with proximal femur reconstruction. The mean Musculoskeletal Tumor Society functional score were 77% (53 to 93).

Recycled autograft reconstruction for primary malignant bone tumor around the hip is a valid method with acceptable morbidity and a favorable functional outcome.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 36 - 36
1 Aug 2021
Holland T Capella S Lee M Sumathi V Davis E
Full Access

The use of routine sampling for histological analysis during revision hip replacement has been standard practice in our unit for many years. It is used to identify the presence of inflammatory processes that may represent peri-prosthetic infection. This study follows up on a smaller study in the same unit in 2019 where an initial 152 cases were scrutinised. In this follow up study we examined 1,361 consecutive patients over a 16-year period whom had undergone revision hip replacement in a tertiary orthopaedic centre for any reason excluding primary bone tumour or malignant metastasis. All patients had tissue sampling for histopathological analysis performed by consultant histopathologists with a specialist interest in musculoskeletal pathology. The presence of bacteria in greater than 50% of samples sent for microbiological analysis in each patient was used as the gold standard diagnostic comparator for infection. This was then compared with the histology report for each patient. After excluding 219 patients with incomplete data and 1 sample rejection, 1,141 cases were examined. Microbiology confirmed infection in 132 cases (prevalence of infection 11.04%) and histopathology analysis suggested infection in 171 cases. Only 64 cases with confirmed infection in more than 50% of microbiology samples had concurrent diagnosis of infection on histological analysis (5.60% of total; PPV 51.20%). Furthermore, microbiology analysis confirmed infection in 62 cases where histological analysis failed to identify infection (5.43% of total; False negative rate 49.21%). Overall, histopathology analysis was seen to have a good specificity of 93.99% but poor sensitivity of 50.79%. We believe that this is the largest series in the literature and is somewhat unique in that all histology analysis was performed by consultant histopathologists with specialist interest in musculoskeletal pathology. Based on the costs incurred by this additional investigation our experience does not support routine sampling for histological analysis in revision hip arthroplasty. This is a substantial paradigm shift from current practice among revision arthroplasty surgeons in the United Kingdom but would equate to a substantial cost saving


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims

Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects.

Methods

We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures.


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 22 - 30
1 Jan 2018
Brown TS Salib CG Rose PS Sim FH Lewallen DG Abdel MP

Aims

Reconstruction of the acetabulum after resection of a periacetabular malignancy is technically challenging and many different techniques have been used with varying success. Our aim was to prepare a systematic review of the literature dealing with these techniques in order to clarify the management, the rate of complications and the outcomes.

Patients and Methods

A search of PubMed and MEDLINE was conducted for English language articles published between January 1990 and February 2017 with combinations of key search terms to identify studies dealing with periacetabular resection with reconstruction in patients with a malignancy. Studies in English that reported radiographic or clinical outcomes were included. Data collected from each study included: the number and type of reconstructions, the pathological diagnosis of the lesions, the mean age and follow-up, gender distribution, implant survivorship, complications, functional outcome, and mortality. The results from individual studies were combined for the general analysis, and then grouped according to the type of reconstruction.


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 177 - 184
1 Feb 2015
Felden A Vaz G Kreps S Anract P Hamadouche M Biau DJ

Conventional cemented acetabular components are reported to have a high rate of failure when implanted into previously irradiated bone. We recommend the use of a cemented reconstruction with the addition of an acetabular reinforcement cross to improve fixation.

We reviewed a cohort of 45 patients (49 hips) who had undergone irradiation of the pelvis and a cemented total hip arthroplasty (THA) with an acetabular reinforcement cross. All hips had received a minimum dose of 30 Gray (Gy) to treat a primary nearby tumour or metastasis. The median dose of radiation was 50 Gy (Q1 to Q3: 45 to 60; mean: 49.57, 32 to 72).

The mean follow-up after THA was 51 months (17 to 137). The cumulative probability of revision of the acetabular component for a mechanical reason was 0% (0 to 0%) at 24 months, 2.9% (0.2 to 13.3%) at 60 months and 2.9% (0.2% to 13.3%) at 120 months, respectively. One hip was revised for mechanical failure and three for infection.

Cemented acetabular components with a reinforcement cross provide good medium-term fixation after pelvic irradiation. These patients are at a higher risk of developing infection of their THA.

Cite this article: Bone Joint J 2015;97-B:177–84.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 628 - 631
1 May 2005
Dunstan E Sanghrajka AP Tilley S Unwin P Blunn G Cannon SR Briggs TWR

Metal-on-metal hip bearings are being implanted into younger patients. The consequence of elevated levels of potentially carcinogenic metal ions is therefore a cause for concern. We have determined the levels of cobalt (Co), chromium (Cr), titanium (Ti) and vanadium (Va) in the urine and whole blood of patients who had had metal-on-metal and metal-on-polyethylene articulations in situ for more than 30 years. We compared these with each other and with the levels for a control group of subjects.

We found significantly elevated levels of whole blood Ti, Va and urinary Cr in all arthroplasty groups. The whole blood and urine levels of Co were grossly elevated, by a factor of 50 and 300 times respectively in patients with loose metal-on-metal articulations when compared with the control group. Stable metal-on-metal articulations showed much lower levels. Elevated levels of whole blood or urinary Co may be useful in identifying metal-on-metal articulations which are loose.