Advertisement for orthosearch.org.uk
Results 1 - 20 of 32
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 14 - 14
1 Mar 2021
Hofmann-Fliri L Epari D Schwyn R Zeiter S Windolf M
Full Access

Fracture fixation has advanced significantly with the introduction of locked plating and minimally invasive surgical techniques. However, healing complications occur in up to 10% of cases, of which a significant portion may be attributed to unfavorable mechanical conditions at the fracture. Moreover, state-of-the-art plates are prone to failure from excessive loading or fatigue. A novel biphasic plating concept has been developed to create reliable mechanical conditions for timely bone healing and simultaneously improve implant strength. The goal of this study was to test the feasibility and investigate the robustness of fracture healing with a biphasic plate in a large animal experiment. Twenty-four sheep underwent a 2mm mid-diaphyseal tibia osteotomy stabilized with either the novel biphasic plate or a control locking plate. Different fracture patterns in terms of defect location and orientation were investigated. Animals were free to fully bear weight during the post-operative period. After 12 weeks, the healing fractures were evaluated for callus formation using micro-computer tomography and strength and stiffness using biomechanical testing. No plate deformation or failures were observed under full weight bearing with the biphasic plate. Osteotomies stabilized with the biphasic plate demonstrated robust callus formation. Torsion tests after plate removal revealed no statistical difference in peak torsion to failure and stiffness for the different fracture patterns stabilized with the biphasic plate. However, the biphasic plate group specimens were 45% stronger (p=0.002) and 48% stiffer (p=0.007) than the controls. The results of this large animal study demonstrate the clinical potential of this novel stabilization concept


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 4 - 4
1 Mar 2021
Braxton T Lim K Rnjak-Kovacina J Alcala-Orozco C Woodfield T Jiang L Jia X Yang X
Full Access

Abstract. Objectives. Assess and characterise the suitability of a novel silk reinforced biphasic 3D printed scaffold for osteochondral tissue regeneration. Methods. Biphasic hybrid scaffolds consisted of 3D printed poly(ethylene glycol)-terephthalate-poly(butylene terephthalate)(PEGT/PBT) scaffold frame work (pore size 0.75mm), which has been infilled with a cast and freeze dried porous silk scaffold (5×5×2mm. 3. ), in addition to a seamless silk top layer (1mm). Silk scaffolds alone were used as controls. Both the biphasic and control scaffolds were characterised via uniaxial compression testing (strain rate 0.1mm/min), and the potential biocompatibility of the scaffolds was tested via in vitro culture of seeded bone marrow stromal cells post fabrication. Results. Uniaxial compression testing showed that the biphasic scaffolds (N=4) initially demonstrated similar behaviour on a stress-strain curve to a silk scaffold alone control group (N=6), until a strain of 30% was reached. After 30% strain, load was transitioned from the silk only chondral layer to the 3D printed PEGT/PBT scaffold which resisted further compression and exhibited a significantly greater compressive modulus of 12.6±0.9MPa compared to 0.113±0.01MPa (p<0.001) in the silk scaffold control group. Following 24hours of seeding, no difference was noticed in cell adhesion behaviour under fluorescent microscopy between silk scaffolds and biphasic scaffolds (n=5). Discussion. The use of 3D printing within this novel scaffold provides a solid framework and increases its versatility. The reinforced silk not only provides the secondary Porous structure to the 3D printed scaffold for the bone phase, but also a superficial layer for the cartilage phase. This unique structure has the potential to fill a niche within osteochondral tissue regeneration, especially with the possibility for its use within personalised medicine. Conclusions. These results demonstrate that the novel silk reinforced biphasic 3D printed scaffold is biocompatible and has suitable mechanical properties for osteochondral tissue regeneration. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 66 - 66
11 Apr 2023
Sebastian S Collin M Liu Y Raina D Tägil M Lidgren L
Full Access

There is a lack of carriers for the local delivery of rifampicin (RIF), one of the cornerstone second defence antibiotic for Staphylococcus aureus deep bone infections (DBIs). RIF is also associated with systemic side effects, and known for causing rapid development of antibiotic resistance when given as monotherapy. We evaluated a clinically usedbi-phasic calcium sulphate/hydroxyapatite (CaS/HA) biomaterial as a carrier for dual delivery of RIF with vancomycin (VAN) or gentamicin (GEN). It was hypothesized that this combined approach could provide improved biofilm eradication and prevent the development of RIF resistance. Methods: 1) Biofilm eradication: Using a modified crystal violet staining biofilm quantification method, the antibiotics released at different time points (Day 1, 3, 7, 14, 21, 28 and 35) from the hemispherical pellets of CaS/HA(500 mg)-VAN (24.57 mg) / GEN (10.35 mg) composites with or without RIF (8.11 mg) were tested for their ability to disrupt the preformed 48-h old biofilms of S. aureus ATCC 25923, and S. aureus clinical strain P-3 in 96-well microtitre plate. For each tested group of antibiotic fractions, five separate wells were used (n=5). 2) Testing for resistance development: Similar to the method mentioned above the 48-h biofilm embeded bacteria exposed to antibiotic fractions from different time points continuously for 7 days. The biofilms remained were then tested for RIF resistant strains of bacteria. Overall, there was clear antibiofilm biofilm activity observed with CaS/HA-VAN/GEN+RIF combinations compared with CaS/HA-VAN/GEN alone. The S. aureus strains developed resistance to RIF when biofilms were subjected to CaS/HA-RIF alone but not with combinations of CaS/HA-VAN/GEN+RIF. Enhanced antibiofilm effects without development of RIF resistance indicates that biphasic CaS/HA loaded with VAN or GEN could be used as a carrier for RIF for additional local delivery in clinically demanding DBIs. Acknowledgement: We deeply acknowledge the Royal Fysiographic Society of Lund, Landshövding Per Westlings Minnesfond and the Stina and Gunnar Wiberg fond for financial support


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 4 - 4
2 Jan 2024
Kucko N Sage K Delawi D Hoebink E Kempen D Van Susante J de Bruijn J Kruyt M
Full Access

Pseudoarthrosis after spinal fusion is an important complication leading to revision spine surgeries. Iliac Crest Bone Graft is considered the gold standard, but with limited availability and associated co-morbidities, spine surgeons often utilize alternative bone grafts. Determine the non-inferiority of a novel submicron-sized needle-shaped surface biphasic calcium phosphate (BCP<µm) as compared to autograft in instrumented posterolateral spinal fusion. Adult patients indicated for instrumented posterolateral spinal fusion of one to six levels from T10-S2 were enrolled at five participating centers. After instrumentation and preparation of the bone bed, the randomized allocation side of the graft type was disclosed. One side was grafted with 10cc of autograft per level containing a minimum of 50% iliac crest bone. The other side was grafted with 10cc of BCP<µm granules standalone (without autograft or bone marrow aspirate). In total, 71 levels were treated. Prospective follow-up included adverse events, Oswestry Disability Index (ODI), and a fine-cut Computerized Tomography (CT) at one year. Fusion was systematically scored as fused or not fused per level per side by two spine surgeons blinded for the procedure. The first fifty patients enrolled are included in this analysis (mean age: 57 years; 60% female and 40% male). The diagnoses included deformity (56%), structural instability (28%), and instability from decompression (20%). The fusion rate determined by CT for BCP<μm was 76.1%, which compared favorably to the autograft fusion rate of 43.7%. Statistical analysis through binomial modeling showed that the odds of fusion of BCP<μm was 2.54 times higher than that of autograft. 14% of patients experienced a procedure or possible device-related severe adverse event and there were four reoperations. Oswestry Disability Index (ODI) score decreased from a mean of 46.0 (±15.0) to a mean of 31.7 (±16.9), and 52.4% of patients improved with at least 15-point decrease. This data, aiming to determine non-inferiority of standalone BCP<μm as compared to autograft for posterior spinal fusions, is promising. Ongoing studies to increase the power of the statistics with more patients are forthcoming


Bone & Joint Research
Vol. 5, Issue 10 | Pages 500 - 511
1 Oct 2016
Raina DB Gupta A Petersen MM Hettwer W McNally M Tägil M Zheng M Kumar A Lidgren L

Objectives. We have observed clinical cases where bone is formed in the overlaying muscle covering surgically created bone defects treated with a hydroxyapatite/calcium sulphate biomaterial. Our objective was to investigate the osteoinductive potential of the biomaterial and to determine if growth factors secreted from local bone cells induce osteoblastic differentiation of muscle cells. Materials and Methods. We seeded mouse skeletal muscle cells C2C12 on the hydroxyapatite/calcium sulphate biomaterial and the phenotype of the cells was analysed. To mimic surgical conditions with leakage of extra cellular matrix (ECM) proteins and growth factors, we cultured rat bone cells ROS 17/2.8 in a bioreactor and harvested the secreted proteins. The secretome was added to rat muscle cells L6. The phenotype of the muscle cells after treatment with the media was assessed using immunostaining and light microscopy. Results. C2C12 cells differentiated into osteoblast-like cells expressing prominent bone markers after seeding on the biomaterial. The conditioned media of the ROS 17/2.8 contained bone morphogenetic protein-2 (BMP-2 8.4 ng/mg, standard deviation (. sd. ) 0.8) and BMP-7 (50.6 ng/mg, . sd. 2.2). In vitro, this secretome induced differentiation of skeletal muscle cells L6 towards an osteogenic lineage. Conclusion. Extra cellular matrix proteins and growth factors leaking from a bone cavity, along with a ceramic biomaterial, can synergistically enhance the process of ectopic ossification. The overlaying muscle acts as an osteoinductive niche, and provides the required cells for bone formation. Cite this article: D. B. Raina, A. Gupta, M. M. Petersen, W. Hettwer, M. McNally, M. Tägil, M-H. Zheng, A. Kumar, L. Lidgren. Muscle as an osteoinductive niche for local bone formation with the use of a biphasic calcium sulphate/hydroxyapatite biomaterial. Bone Joint Res 2016;5:500–511. DOI: 10.1302/2046-3758.510.BJR-2016-0133.R1


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 106 - 106
2 Jan 2024
Shin H
Full Access

Recently, technologies to culture one or more cell types in three dimensions have attracted a great deal of attention in tissue engineering. Particularly, the improved viability, self-renewal capacity, and differentiation potential have been reported for stem cell spheroids. However, it is crucial to modulate spheroid functions with instructive signals to use multi-cellular spheroids in tissue engineering. We have been developing ECM-mimicking fibrous materials decorated with cell-instructive cues, which were incorporated within 3D stem cell spheroids to fine-tune their functions as modular building blocks for bottom-up tissue-engineering applications. In particular, we created composite spheroids of human adipose-derived stem cells (hADSCs) incorporating nanofibers coated with instructive signal of either transforming growth factor-β3 or bone morphogenetic growth factor-2 for chondrogenesis or osteogenesis of stem cells, respectively. The bilayer structure of osteochondral tissue was subsequently mimicked by cultivating each type of spheroid inside 3D-printed construct. The in vitro chondrogenic or osteogenic differentiation of hADSCs within the biphasic construct under general media was locally regulated by each inductive component. More importantly, hADSCs from each spheroid proliferated and sprouted to form the integrated tissue with interface of bone and cartilage tissue. This approach may be applied to engineer complex tissue with hierarchically organized structure


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 110 - 110
2 Jan 2024
Kucko N Crowley J Wills D Wang T Pelletier M Yuan H Houtzager G Campion C Walsh W de Bruijn J Groot FB
Full Access

Biphasic calcium phosphate (BCP) with a characteristic needle-shaped submicron surface topography (MagnetOs) has attracted much attention due to its unique bone-forming ability which is essential for repairing critical-size bone defects such as those found in the posterolateral spine. Previous in vitro and ex-vivo data performed by van Dijk LA and Yuan H demonstrated that these specific surface characteristics drive a favorable response from the innate immune system. This study aimed to evaluate and compare the in vivo performance of three commercially-available synthetic bone grafts, (1) i-FACTOR Putty. ®. , (2) OssDsign. ®. Catalyst Putty and (3) FIBERGRAFT. ®. BG Matrix, with that of a novel synthetic bone graft in a clinically-relevant instrumented sheep posterolateral lumbar spine fusion (PLF) model. The novel synthetic bone graft comprised of BCP granules with a needle-shaped submicron surface topography (MagnetOs) embedded in a highly porous and fibrillar collagen matrix (MagnetOs Flex Matrix). Four synthetic bone grafts were implanted as standalone in an instrumented sheep PLF model for 12 weeks (n=3 bilateral levels per group; levels L2/3 & L4/5), after which spinal fusion was determined by manual palpation, radiograph and µCT imaging (based on the Lenke scale), range-of-motion mechanical testing, and histological and histomorphological evaluation. Radiographic fusion assessment determined bilateral robust bone bridging (Lenke scale A) in 3/3 levels for MagnetOs Flex Matrix compared to 1/3 for all other groups. For µCT, bilateral fusion (Lenke scale A) was found in 2/3 levels for MagnetOs Flex Matrix, compared to 0/3 for i-FACTOR Putty. ®. , 1/3 for OssDsign. ®. Catalyst Putty and 0/3 for FIBERGRAFT. ®. BG Matrix. Fusion assessment for MagnetOs Flex Matrix was further substantiated by histology which revealed significant graft resorption complemented by abundant bone tissue and continuous bony bridging between vertebral transverse processes resulting in bilateral spinal fusion in 3/3 implants. These results show that MagnetOs Flex Matrix achieved better fusion rates compared to three commercially-available synthetic bone grafts when used as a standalone in a clinically-relevant instrumented sheep PLF model


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 65 - 65
17 Nov 2023
Khatib N Schmidtke L Lukens A Arichi T Nowlan N Kainz B
Full Access

Abstract. Objectives. Neonatal motor development transitions from initially spontaneous to later increasingly complex voluntary movements. A delay in transitioning may indicate cerebral palsy (CP). The general movement optimality score (GMOS) evaluates infant movement variety and is used to diagnose CP, but depends on specialized physiotherapists, is time-consuming, and is subject to inter-observer differences. We hypothesised that an objective means of quantifying movements in young infants using motion tracking data may provide a more consistent early diagnosis of CP and reduce the burden on healthcare systems. This study assessed lower limb kinematic and muscle force variances during neonatal infant kicking movements, and determined that movement variances were associated with GMOS scores, and therefore CP. Methods. Electromagnetic motion tracking data (Polhemus) was collected from neonatal infants performing kicking movements (min 50° knee extension-flexion, <2 seconds) in the supine position over 7 minutes. Tracking data from lower limb anatomical landmarks (midfoot inferior, lateral malleolus, lateral knee epicondyle, ASIS, sacrum) were applied to subject-scaled musculoskeletal models (Gait2354_simbody, OpenSim). Inverse kinematics and static optimisation were applied to estimate lower limb kinematics (knee flexion, hip flexion, hip adduction) and muscle forces (quadriceps femoris, biceps femoris) for isolated kicks. Functional principal component analysis (fPCA) was carried out to reduce kicking kinematic and muscle force waveforms to PC scores capturing ‘modes’ of variance. GMOS scores (lower scores = reduced variety of movement) were collected in parallel with motion capture by a trained operator and specialised physiotherapist. Pearson's correlations were performed to assess if the standard deviation (SD) of kinematic and muscle force waveform PC scores, representing the intra-subject variance of movement or muscle activation, were associated with the GMOS scores. Results. The study compared GMOS scores, kinematics, and muscle force variances from a total of 26 infants with a mean corrected gestational age of 39.7 (±3.34) weeks and GMOS scores between 21 and 40. There was a significant association between the SD of the PC scores for knee flexion and the GMOS scores (PC1: R = 0.59, p = 0.002; PC2: R = 0.49, p = 0.011; PC3: R = 0.56, p = 0.003). The three PCs captured variances of the overall flexion magnitude (66% variance explained), early-to-late kick knee extension (20%), and continual to biphasic kicking (6%). For hip flexion, only the SD of PC1 correlated with GMOS scores (PC1: R = 0.52, p = 0.0068), which captured the variance of the overall flexion magnitude (81%). For the biceps femoris, the SD of PC1 and PC3 associated with GMOS scores (PC1: R = 0.50, p = 0.002; PC3: R = 0.45, p = 0.03), which captured the variance of the overall bicep force magnitude (79%) and early-to-late kick bicep activation (8%). Conclusions. Infants with reduced motor development as scored in the GMOS displayed reduced variances of knee and hip flexion and biceps femoris activation across kicking cycles. These findings suggest that combining objectively measured movement variances with existing classification methods could facilitate the development of more consistent and accurate diagnostic tools for early detection of CP. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 2 - 2
1 Nov 2018
van Griensven M
Full Access

The structure and extracellular matrix composition of the interface are complex and allow for a gradual mechanical stress transfer between tendons and bone. In this study, biphasic silk fibroin scaffolds designed to mimic the gradient in collagen molecule alignment present at the interface. The scaffolds had two different pore alignments: anisotropic at the tendon side and isotropic at the bone side. Total porosity ranged from 50–80% and the majority of pores were <100–300 µm. Young's modulus varied from 689–1322 kPa. In addition, human adMSC were cultured on the scaffolds to evaluate the effect of pore morphology on cell proliferation and gene expression. Biphasic scaffolds supported cell attachment and influenced cytoskeleton organization depending on pore alignment. In addition, the gene expression of tendon, enthesis and cartilage markers significantly changed in each region of the scaffolds. We functionalized those scaffolds with heparin and explored their ability to deliver TGF-β2 and GDF5. TGF-β2 and pore anisotropy synergistically increased the expression of tendon/ligament markers and collagen I protein content. The combined delivery of TGF-β2 and GDF5 enhanced the expression of cartilage markers and collagen II protein content on substrates with isotropic porosity, whereas enthesis markers were enhanced in areas of mixed anisotropic/isotropic porosity


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 55 - 55
1 Nov 2018
Moeller K Gottardi R Tellado SF Tuan R van Griensven M Balmayor ER
Full Access

After surgical tendon repair, the tendon-to-bone enthesis often doesn't regenerate, which leads to high numbers of rupture recurrences. To remedy this, tissue engineering techniques are being pursued to strengthen the interface and improve regeneration. In this study, we used biphasic 3D printed PLGA scaffolds with aligned pores at the tendon side and random pores at the bone side to mimic the native enthesis. We seeded these with mesenchymal stem cells and inserted them into dual-flow bioreactors, allowing us to employ tenogenic and chondrogenic differentiation medium in separate flows. MTS assay demonstrated metabolism in dual-flow bioreactors at levels similar to tissue culture plate and rotating bioreactors. After 7, 14 and 21 days, samples were collected and analyzed by histology, RT-PCR and GAG production. H&E staining confirmed a compact cell layer attached to fibers and between porous cavities of scaffolds that increased with time of culture. Interestingly, cultured constructs in dual-flow bioreactors biased towards a chondrogenic fate regardless of which flow they were exposed to, possibly due to high porosity of the scaffold allowing for fluid mixture. Sox9 was upregulated at all timepoints (up to 30× compared to control), and by day 21 Col2A1 was also highly upregulated. Additionally, GAG production in treated constructs (serum-free) was able to match constructs exposed to 10% FBS in controls, demonstrating the functional matrix forming capabilities of this system. Overall, we have validated this dual-flow system as a potential platform to form the enthesis, and future studies will further optimize parameters to achieve distinctly biphasic constructs


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 195 - 195
1 Jul 2014
Malhotra A Pelletier M Yu Y Christou C Walsh W
Full Access

Summary Statement. An autologous thrombin activated 3-fold PRP, mixed with a biphasic calcium phosphate at a 1mL:1cc ratio, is beneficial for early bone healing in older age sheep. Introduction. The management of bone defects continues to present challenges. Upon activation, platelets secrete an array of growth factors that contribute to bone regeneration. Therefore, combining platelet rich plasma (PRP) with bone graft substitutes has the potential to reduce or replace the reliance on autograft. The simple, autologous nature of PRP has encouraged its use. However, this enthusiasm has failed to consistently translate to clinical expediency. Lack of standardisation and improper use may contribute to the conflicting outcomes reported within both pre-clinical and clinical investigations. This study investigates the potential of PRP for bone augmentation in an older age sheep model. Specifically, PRP dose is controlled to provide clearer indications for its clinical use. Methods. Eighty 11mm diameter defects of 20mm in depth were created in the cancellous bone within the epiphyseal region of the medial proximal tibia and distal femur of twenty five-year-old sheep. The defects were treated with three doses of an autologous thrombin activated PRP combined with a biphasic calcium phosphate (BCP). Activated platelet poor plasma (PPP) and the BCP alone provided reference groups, while the autograft and empty defects served as controls. All animals were sacrificed at four weeks post-operatively for radiographic assessment, micro-computed tomography quantification, histological assessment, histomorphometric quantification of new bone area and bone ingrowth, and weekly fluorochrome bone label quantification. TGF-β1 concentrations were quantified using enzyme-linked immunosorbent assays. Results. The PRP had a 2.9-fold (0.4) increase in platelet concentration, a 0.57-fold (0.09) decrease in leukocytes, and a 0.65-fold (0.11) decrease in fibrinogen. After activation, the PRP had an 8.9-fold (1.5) increase in TGF-β1 serum concentration above baseline. Eleven (11) mm diameter cancellous bone defects in the hind legs of five-year-old sheep do not spontaneously heal within four weeks. PRP dose had a significant effect on the radiographic grade. The highest dose of PRP treatment had a significantly greater micro-CT BV/TV over the BCP alone (PRP: 30.6±1.8%; BCP: 24.5±0.1%). All doses of PRP treatment were significantly greater than the BCP alone for both the histomorphometric new bone area (PRP: 14.5±1.3%; BCP: 9.7±1.5%) and bone ingrowth depth (PRP: 2288±210µm; BCP:1151±268µm). From week two onwards, PRP had a significant effect on the weekly bone ingrowth over BCP, however, autograft had the greatest amount of fluorescently labelled bone within the first three weeks. PRP has a significant effect on the shape and density of osteoblasts within the central region of the defect compared to the BCP alone, however, was not significantly different to autograft. TGF-β1 appeared a better predictor of healing outcomes than platelet concentration, however both had relatively weak correlations (r<.324). Conclusion. PRP induces new bone formation with a dose dependant response at four weeks when used with a biphasic calcium phosphate in older age sheep


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 118 - 118
1 Mar 2021
Jeuken R Roth A Peters M Welting T Rhijn L Thies J Emans P
Full Access

Focal knee resurfacing implants (FKRIs) are typically intended to treat focal cartilage defects in middle-aged patients. All currently available FKRIs are (partly) composed of metal, which potentially leads to degeneration of the opposing articulating cartilage and hampers follow-up using magnetic resonance imaging (MRI). The purpose of this study was to investigate the in vivo osseointegration process of a novel non-degradable thermoplastic polycarbonate-urethane (TPU) osteochondral implant. Bi-layered implants measuring 6 mm in diameter, with a double-curvature to match the approximate curvature of the goat medial femoral condyle were fabricated. TPU implants were composed of an articulating Bionate® II 80A top layer, and a Bionate® 75D bottom layer (DSM Biomedical, Geleen, the Netherlands) which is intended to osseointegrate. A biphasic calcium phosphate coating formulation, optimized during a prior in vitro study, was applied to half of the TPU implants, while the other half was left uncoated. Bi-layered metal implants (articulating cobalt-chromium top layer and titanium bottom layer) were used as positive control implants. Eight implants per group were implanted bilaterally in the medial femoral condyle of the stifle joints in 12 Dutch milk goats. 18F-sodium fluoride (18F-NaF) positron emission tomography-computed tomography (PET-CT) scanning was performed at 3 and 12 weeks postoperatively, and the corrected maximum standard uptake values (cSUVmax) was calculated to assess the peri-implant bone metabolism. After sacrifice 12 weeks postoperatively, bone histomorphometric analysis was performed to assess the bone-to-implant contact area (BIC). Student's T-test was used in case of normal distribution and the Mann-Whitney-U-test was used in case of abnormal distribution for comparison of BIC and cSUVmax. The BIC value of 10.27 ± 4.50% (mean ± SD) for the BCP-coated TPU implants was significantly (P=0.03) higher than the 4.50 ± 2.61% for the uncoated TPU implants. The uncoated TPU implants scored significantly (P=0.04) lower than the BIC of 12.81 ± 7.55% for the metal implants, whereas there was no significant difference between BCP-coated TPU implants and the metal implants (P=0.68). There was a strong correlation between the cSUVmax values and the BIC values at 12 weeks (Pearson's R=0.74, P=0.001). The cSUVmax values significantly decreased between 3 and 12 weeks for the metal implants (p=0.04). BCP-coated TPU implants followed a similar trend but did not reach statistical significance (p=0.07). cSUVmax in the uncoated TPU implants did not show a significant difference between the time-points (p=0.31). Osseointegration of BCP-coated TPU implants did not significantly differ from metal implants. 18F-NaF PET-CT is a feasible modality to assess osseointegration patterns and showed a similar trend between the BCP-coated and metal implants. Hence, an implant fully composed of TPU may avoid the typical metal-related drawbacks of currently available FKRIs. Long-term follow-up studies are advocated to address the effects of the implant to the opposing cartilage, and are therefore warranted


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 100 - 100
1 Dec 2020
Sebastian S Liu Y Sezgin EA Tarasevičius Š Raina DB
Full Access

Background. With promising antibiofilm properties, rifampicin is considered as a cornerstone in the complementary treatment of bone and joint infections. But, achieving an adequate concentration of rifampicin long-term in bone tissue is a challenge. Long-term systemic administration also comes with concomitant side effects. Thus, local delivery of rifampicin in a carrier to ensure the high local concentration of antibiotic in surgical site after intervention due to infection could be a valuable alternative. However, an ideal platform for local delivery of rifampicin is still lacking. A calcium sulphate/hydroxyapatite (CaS/HA) (Cerament, Bonesupport AB, Sweden) biomaterial was used as a local delivery platform. Here we aimed 1) to evaluate the injectability of CaS/HA hand-mixed with rifampicin at various concentrations up to maximum one daily dose used systemically in clinical practice 2) to test a clinically used and commercially available mixing device containing the biphasic ceramic with rifampicin. Materials & Methods. Three different concentrations (100 mg, 300 mg and 600 mg) of rifampicin powder (Rifampicin Ebb, Sanofi S.P.A, Italy) diluted in 5 mL of mixing solution (C-TRU, Bonesupport AB, Sweden) were used. Rifampicin solution was mixed to the CaS/HA powder and the injectability of the CaS/HA plus rifampicin composite was evaluated by extruding 250 µL of paste manually through a graduated 1 mL syringe connected to an 18G needle (Ø=1.2 mm, L=4 cm). Mixing was done with a spatula for 30 s at 22°C ±1°C. Total weight of the paste before and after extrusion were measured. To normalize the amount of composite that remained in the needle and syringe tip after injection, the mean of the paste extruded from the syringe at 3 min was calculated for the tested concentrations (normalized value). Injectability (%) was calculated by dividing the weight of the paste extruded from the syringe with normalized value. Each test was repeated for three times at various time points (3, 5, 7 and 9 min). Additionally, 300 mg rifampicin was chosen to mix with the CaS/HA in a commercially available mixing system, which is used clinically. Results. All three combinations of CaS/HA plus rifampicin (100 mg, 300 mg & 600 mg) could be completely extruded from 1 mL syringes at 3 min. At 5 min, 100 mg & 300 mg could still be injected, whereas 600 mg was uninjectable or solidified. At 7 min, rifampicin 100 mg & 300 mg showed 34% and 11% of injectability respectively. At 9 min, no injectability was observed. The material was completely set within 15 minutes with all concentrations. With commercial mixing system, at the recommended injection time of 4 min, 78% of the CaS/HA plus rifampicin (300 mg) composite could be injected. Conclusions. The injectability was reduced with the increasing concentration of rifampicin. CaS/HA plus rifampicin (100 mg and/or 300 mg) could be used by hand mixing and transferred to a syringe or by using an available mixing system containing the ceramic. For higher concentrations of rifampicin, the rheological properties of the ceramics have to be modified for injectability


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 421 - 425
1 Mar 2005
Blom AW Cunningham JL Hughes G Lawes TJ Smith N Blunn G Learmonth ID Goodship AE

This study investigates the use of porous biphasic ceramics as graft extenders in impaction grafting of the femur during revision hip surgery. Impaction grafting of the femur was performed in four groups of sheep. Group one received pure allograft, group two 50% allograft and 50% BoneSave, group three 50% allograft and 50% BoneSave type 2 and group four 10% allograft and 90% BoneSave as the graft material. Function was assessed using an index of pre- and post-operative peak vertical ground reaction force ratios. Changes in bone mineral density were measured by dual energy X ray absorptiometry (DEXA) scanning. Loosening and subsidence were assessed radiographically and by histological examination of the explanted specimens. There was no statistically significant difference between the four groups after 18 months of unrestricted functional loading for all outcome measures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 86 - 86
1 Nov 2018
Gottardi R
Full Access

Cartilage-bone interactions play a critical role in joint diseases and the osteochondral junction has been identified as a locus of osteoarthritis development. However, it is challenging to study osteochondral (OC) interaction in vitro, since cartilage and bone require very different environments. We developed a new medium-to-high throughput osteochondral microphysiological system bioreactor to culture biphasic native or engineered constructs and that can be used to study any musculoskeletal tissue interfaces. We developed engineered constructs from hMSCs on a porous polymeric matrix with a gradient in pore size to assess the supportive effect of the local topology on cartilaginous and osseous differentiation. Furthermore, we developed a triphasic, vascualized osteochondral constructs based on porous polycaprolactone and methacrylated gelatin scaffolds to study the specific effects of vasculature on cartilage and bone. We also cultured native OC tissues from postmenopausal women, exposing either cartilage or bone to sex hormones studying their protective effects. Finally, our bioreactor is being implemented for use on the International Space Station to study countermeasures against microgravity bone loss. Overall, our bioreactor maintains media separation for in vitro culture and engineering of OC tissues and constructs of progressively greater complexity, and it preserves the possibility of direct cartilage-bone crosstalk opening new opportunities to study interactions across the osteochondral junction


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 121 - 121
1 Nov 2018
Jacobs A Renaudin G Vichery C Forestier C Charbonnel N Descamps S
Full Access

Biphasic calcium phosphates (BCP) are the most frequently used materials because of their mineral analogy with bio-mineral part of bones. Their chemical synthesis can be modulated by doping, in order to respond to the biological needs. We present here the biological responses induced by copper ions in solution, to characterize its cytotoxicity and antibacterial activity. We also investigate the antibacterial property of Cu-doped BCP (Ca10 Cu0.1 (PO4)6 (OH)1.8 O0.2) on a strain of clinical interest: S. aureus, compared to undoped BCP. The sol-gel route has been used to prepare the BCP ceramics. Human BMC (Bone Marrow Cells) were obtained from metaphysal cancellous bone collected during hip arthroplasty and used for cytotoxicity evaluations. A strain of Staphylococcus aureus isolated from an osteoarticular infection after total knee arthroplasty was used to evaluate antibacterial activities. Results indicate that 3 ppm of copper ions leads to the death of all cultured bacteria in 24 hours and 25 ppm caused the death of all cells in 15 days. Regarding BCP, the undoped bioceramics increased the bacterial growth compared to a control without bioceramic. After 16 hours of contact, the copper ions released by the Cu-doped BCP induced a significant decrease of the bacterial concentration, indeed no viable bacteria were found. These materials seem to be a promising alternative for the preparation of multifunctional bone substitutes


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 56 - 56
1 Nov 2018
Kalaf EAG Barry F
Full Access

Early clinical studies investigating the effects of delivery of mesenchymal stromal cells (MSCs) to degenerated intervertebral discs have shown promising results, but with an incomplete understanding of the therapeutic mechanism(s) of action. To address this, we have developed a 3D co-culture system to unravel the biological interaction between MSCs and nucleus pulposus (NP) cells. Alginate constructs were created using a biphasic configuration consisting of a cylindrical shell with an encapsulated bead. Human NP cells were seeded in monolayer or encapsulated within alginate and cultured in hypoxia with variations of pH, osmolarity and growth factors (n = 6) to replicate healthy or degenerative conditions. Wells and gels were fixed and stained for ECM content, and retrieved cells and media were analysed for ECM and inflammatory factor expression. Encapsulated hNPCs showed no migration from either alginate structure and full bead separation was achieved over 14 days, reinforcing the construct as a separable 3D co-culture method. Addition of the degenerative growth factors TNFα and IL-1β as well as the adjustment of media pH to degenerative levels (pH 6.8) caused the hNPCs to decrease in size and proliferate significantly higher than control levels. TGF-β3 addition showed higher incidence of aggrecan deposition over addition of IL-1β. Addition of FGF2 altered cell morphology and ECM deposition including formation of pseudo lamellae, indicating a phenotype shift toward annulus fibrosis cells as shown in late-stage degenerative disc disease. The data from this study will be used in future MSC:NPC co-cultures to determine immunoregulatory interactions in a degenerative environment


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 111 - 111
1 Nov 2018
Mogensen SL Rasmussen MK Le D Nielsen A Foldager CB
Full Access

Osteoarthritis (OA) is an inflammatory degenerative disease that affects every fourth person with irreversible damage to the articular. Mesenchymal stem cells (MSCs) have been shown to affect host cells by paracrine stimulation in regenerative environments. Here we apply hyaluronic acid (HA), an essential part of the extracellular matrix in cartilage, for MSC immobilization. The aim was to investigate long-term MSC survival and paracrine effect on chondrocytes in an inflammatory co-culture environment. We hypothesized that MSCs immobilized in a HA hydrogel could provide a long-term immunomodulatory effect on chondrocytes in vitro. Human MSCs were seeded in a HA hydrogel and co-cultured with non-osteoarthritic human chondrocytes in biphasic wells inhibiting cellular contact. An inflammatory environment was induced by IL1-beta and compared with standard culture medium. Relative gene expressions of collagen types I, II and X, aggrecan, SOX9, MMP-13 and ADAMTS-5) were examined at day 3,7,14 and 28. Significant up-regulation of SOX9 at day 7, 14 and 28 and a significant down-regulation of ADAMTS-5 (day 14 and 28) was observed with co-culture of HA-immobilized MSCs and MSCs compared with controls with or without HA (without MSCs)No changes in expression was observed for aggrecan and collagen type 1. We showed that MSC affect the expression of SOX9 and ADAMTS-5 in a paracrine manner when co-cultured with chondrocytes in an inflammatory environment. MSCs immobilized in HA hydrogels survived and were contained in the hydrogel for up to 28 days. This suggests that HA-immobilized MSCs could potentially be used as adjuvant treatment of OA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 98 - 98
1 Nov 2018
Flegeau K Gautier H Rethore G Bordat P Weiss P
Full Access

Tissue engineering is a promising approach to regenerate damaged skeletal tissues. In particular, the use of injectable hydrogels alleviates common issues of poor cell viability and engraftment. However, uncontrolled cell fate, resulting from unphysiological environments and degradation rates, still remain a hurdle and impedes tissue healing. We thus aim at developing a new platform of injectable hyaluronic acid (HA) hydrogels with a large panel of properties (stiffness, degradation…) matching those of skeletal tissues. Hence, HA with different molecular weights were functionalized with silylated moieties. Upon injection, these hydrogels formed through a sol-gel chemistry within 5 to 20 minutes in physiological conditions, as demonstrated by rheological characterization. By varying the crosslinking density and concentration, we obtained hydrogels spanning a large range of elastic moduli (E = 0.1–20 kPa), similar to those of native ECMs, with tunable biodegradation rates (from 24 hours to > 50 days) and swelling ratios (500 to 5000% (w/w)). Cell viability was confirmed by Live/Dead assays and will be completed by in vivo subcutaneous implantations in mice to study the foreign body reaction and degradation rate. We further developed hybrid HA/biphasic calcium phosphate granules hydrogels and demonstrated a strong mechanical reinforcement (E = 0.1 MPa) and a faster relaxation behaviour (τ. 1/2. < 400s), with similar degradation rates. Ongoing in vitro differentiation assays and in vivo implantations in a rabbit femur model will further assess their ability to drive bone regeneration. Collectively, these results suggest that this hydrogel platform offers promising outcomes for improved strategies in skeletal tissue engineering


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 13 - 13
1 Apr 2018
Van Houcke J Galibarov PE Fauconnier S Pattyn C Audenaert EE
Full Access

Introduction. A deep squat (DS) is a challenging motion at the level of the hip joint generating substantial reaction forces (HJRF). During DS, the hip flexion angle approximates the functional range of hip motion. In some hip morphologies this femoroacetabular conflict has been shown to occur as early as 80° of hip flexion. So far in-vivo HJRF measurements have been limited to instrumented hip implants in a limited number of older patients performing incomplete squats (< 50° hip flexion and < 80° knee flexion). Clearly, young adults have a different kinetical profile with hip and knee flexion ranges going well over 100 degrees. Since hip loading data on this subgroup of the population is lacking and performing invasive measurements would be unfeasible, this study aimed to report a personalised numerical model solution based on inverse dynamics to calculate realistic in silico HJRF values during DS. M&M. Fifty athletic males (18–25 years old) were prospectively recruited for motion and morphological analysis. DS motion capture (MoCap) acquisitions and MRI scans of the lower extremities with gait lab marker positions were obtained. The AnyBody Modelling System (v6.1.1) was used to implement a novel personalisation workflow of the AnyMoCap template model. Bone geometries, semi-automatically segmented from MRI, and corresponding markers were incorporated into the template human model by an automated nonlinear morphing. Furthermore, a state-of-the-art TLEM 2.0 dataset, included in the Anybody Managed Model Repository (v2.0), was used in the template model. The subject-specific MoCap trials were processed to compute squat motion by resolving an overdeterminate kinematics problem. Inverse dynamics analyses were carried out to compute muscle and joint reaction forces in the entire body. Resulting hip joint loads were validated with measured in-vivo data from Knee bend trials in the OrthoLoad library. Additionally, anterior pelvic tilt, hip and knee joint angles were computed. Results. A preliminary set of results (20 out of 50 subjects) was analysed. The average HJRF was 3.42 times bodyweight at the peak of DS (95% confidence interval: 2.99 – 3.85%BW). Maximal hip and knee flexion angles were 113° (109.7°–116.8°) and 116° (109.4 – 123.0°) respectively. The anterior pelvic tilt demonstrated a biphasic profile with peak value of 33° (28.1° – 38.4°). Discussion. A non-invasive and highly personalised alternative for determining hip loading was presented. Consistently higher HJR forces during DS in young adults were demonstrated as opposed to the Orthoload dataset. Similarly, knee and hip flexion angles were much higher, which could support the increase in HJRF. We can conclude that DS hip kinetics in young adults clearly differ from the typical total hip arthroplasty population