Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 15 - 15
1 Dec 2015
Walter R Harries W Hepple S Winson I
Full Access

The Zenith. TM. total ankle replacement (Corin, Cirencester) is a mobile-bearing implant based on the Buechal Pappas design. Key features are the simple fully-jigged instrumentation aiming to improve accuracy and reproducibility of implant positioning, cementless calcium phosphate coated surfaces for improved early osseointegration, and titanium nitride-coated bearing surfaces to resist wear. We present early to mid-term survival data for 155 total ankle replacements implanted by three surgeons in our institute. Case records of all patients undergoing Zenith. TM. Total Ankle Replacement by three senior surgeons, including a member of the design team, between 2007 and 2014 were examined. Patients were examined clinically and radiographically annually after the early postoperative period. The primary outcome measure was implant survival. Secondary outcome measures included complication rates, parameters of radiographic alignment, and radiographic evidence of cysts and loosening. One hundred and fifty-five cases were performed for a mixture of primary pathologies, predominantly primary or posttraumatic arthrosis. Mean follow-up was 50 months. Implant survival was 99.0% at 3 years (n=103), 94.0% at 5 years (n=50), and 93.8% at 7 years (n=16). One patient was revised to arthrodesis for aseptic loosening, one arthrodesis was performed for periprosthetic infection with loosening, and one below-knee amputation was performed for chronic pain. Three cases underwent further surgery to address cysts, and 7 malleolar fractures were reported. Medial gutter pain was experienced by 9% of patients. Overall, our data show excellent early and mid-term survivorship for the Zenith. TM. Total Ankle Replacement. Simple fully-jigged instrumentation allows accurate and reproducible implant alignment


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 69 - 74
1 Jan 2009
Wood PLR Sutton C Mishra V Suneja R

We describe the results of a randomised, prospective study of 200 ankle replacements carried out between March 2000 and July 2003 at a single centre to compare the Buechel-Pappas (BP) and the Scandinavian Total Ankle Replacement (STAR) implant with a minimum follow-up of 36 months. The two prostheses were similar in design consisting of three components with a meniscal polyethylene bearing which was highly congruent on its planar tibial surface and on its curved talar surface. However, the designs were markedly different with respect to the geometry of the articular surface of the talus and its overall shape.

A total of 16 ankles (18%) was revised, of which 12 were from the BP group and four of the STAR group. The six-year survivorship of the BP design was 79% (95% confidence interval (CI) 63.4 to 88.5 and of the STAR 95% (95% CI 87.2 to 98.1). The difference did not reach statistical significance (p = 0.09). However, varus or valgus deformity before surgery did have a significant effect) (p = 0.02) on survivorship in both groups, with the likelihood of revision being directly proportional to the size of the angular deformity. Our findings support previous studies which suggested that total ankle replacement should be undertaken with extreme caution in the presence of marked varus or valgus deformity.