Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 71 - 71
1 Dec 2021
Giles W Komperla S Flatt E Gandhi M Eyre-Brook A Jones V Papanna M Eves T Thyagarajan D
Full Access

Abstract. Background/Objectives. The incidence of reverse total shoulder replacement (rTSR) implantation is increasing globally, but apprehension exists regarding complications and associated challenges. We retrospectively analysed the senior author's series of rTSR from a tertiary centre using the VAIOS shoulder system, a modular 4th generation implant. We hypothesised that the revision rTSR cohort would have less favourable outcomes and more complications. Methods. 114 patients underwent rTSR with the VAIOS system, over 7 years. The primary outcome was implant survival. Secondary outcomes were Oxford shoulder scores (OSS), radiographic analysis (scapular notching, tuberosity osteolysis, and periprosthetic radiolucent lines) and complications. Results. There were 55 Primary rTSR, 31 Revision rTSR and 28 Trauma rTSR. Implant survival: Primary rTSR- 0 revisions, average 3.35-year follow-up. Revision rTSR-1 revision (4.17%), average 3.52-year follow-up. Trauma rTSR- 1 revision (3.57%), average 4.56-year follow-up OSS: Average OSS improved from 15.39 to 33.8 (Primary rTSR) and from 15.11 to 29.1 (Revision rTSR). Average post-operative OSS for the Trauma rTSR was 31.4 Radiological analysis and complications: Low incidence of scapular notching One hairline fracture below the tip of stem, noted incidentally, which required no treatment. One periprosthetic fracture after alcohol related fall. Treated non-surgically One joint infection requiring two-stage revision to rTSR. One dislocation noted at 2 year follow up. This patient had undergone nerve grafting within 6 months of rTSR for axillary nerve injury sustained during the original fracture dislocation. One acromial fracture with tibial and distal humeral fracture after a fall. Conclusions. The 4th generation modular VAIOS implant is a reliable option for various indications. The revision rTSR cohort had favourable outcomes with low complication rates. In this series, early-to-medium term results suggest lower revision rates and good functional outcomes when compared to published reports. We plan to monitor long-term implant survivorship and patient reported outcomes. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 85 - 85
1 Mar 2021
Hussain A Poyser E Mehta H
Full Access

Abstract. Introduction. Local anaesthetic injections are regularly used for perioperative pain relief for shoulder arthroscopies. In our practice all shoulder arthroscopies were performed under general aneasthesia supplemented by perioperative subacromial local anaesthetic injections or landmark guided axillary nerve together with suprascapular nerve injections. We compared pain relief achieved with these two methods. We hypothesized that the selective nerve blocks would provide better post operative pain relief as described in literature. Methods. We conducted a retrospective cohort study on two patient groups with 17 patients each. Group one patients received 20mls 50:50 mixture of 1% lignocaine and 0.5% chirocaine injections before and after start of procedure and group two patients received 20 mls of chirocaine around the axillary and suprascapular nerves. VAS scores were collected at 1 and 4 hours and analgesia taken during the first 24 hours was recorded. Results. No significant difference in pain scores was noted but analgesia requirements in the nerve block group were higher. Conclusion. Landmark guided nerve blocks did not show any advantage over subacromial local anaesthetic in our study. This is in contrast to published literature and we believe subacromial injections are more reliable and reproducible. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 37 - 37
1 Aug 2013
Welsh F Barnes S
Full Access

Displaced proximal Humeral fractures at Inverclyde Royal Hospital prior to 2008 were previously treated with the antegrade Acumed Polaris Proximal Humeral, predominantly in 2 part fractures. The Philos plate was introduced in 2008, initially being used to treat select non unions, and then expanded to acute fractures. The aim of this study was to assess time to union and complications in the lower volume District General setting comparing to published outcomes. From February 2008 – January 2011, 20 patients were identified. Age range 49–75 (mean 61.2) years, 8 male; 12 female. Left 9, Right 11 Neers 2 part 35%; 3 35%; 4 30%. 16 (80%) were performed in acute fractures with 4 for non-unions, 3 of which were previous polaris nail fixations. 2 patients were lost to follow up after 6/52 but were progressing well. Union was confirmed radiologically and clinically in all but 2 remaining patients (10%), one of whom suffered a significant complication of plate fracture, the second treated with revision for painful non union. 2 other significant complications were observed: transient axillary nerve palsy and deep infection. Both of these patients recovered with delayed union observed in the infection case (52 weeks). Time to union range was 8–52 weeks (mean 17.1). The literature shows a high failure rate of up to 45% with intramedullary nail fixation and limited predominantly to 2 part fractures with risk of damage to the rotator cuff. This study shows a satisfactory union rate using the Philos of 90% with only 3 (15%) requiring further surgery for non-union, plate fracture and infection. 3 and 4 part fractures composed 65% of case load. Early results indicate satisfactory outcomes compared to current published literature


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 586 - 594
1 Apr 2010
Sonnabend DH Howlett CR Young AA

The establishment of a suitable animal model of repair of the rotator cuff is difficult since the presence of a true rotator cuff anatomically appears to be restricted almost exclusively to advanced primates. Our observational study describes the healing process after repair of the cuff in a primate model. Lesions were prepared and repaired in eight ‘middle-aged’ baboons. Two each were killed at four, eight, 12 and 15 weeks post-operatively. The bone-tendon repair zones were assessed macroscopically and histologically.

Healing of the baboon supraspinatus involved a sequence of stages resulting in the reestablishment of the bone-tendon junction. It was not uniform and occurred more rapidly at the sites of suture fixation than between them. Four weeks after repair the bone-tendon healing was immature. Whereas macroscopically the repair appeared to be healed at eight weeks, the Sharpey fibres holding the repair together did not appear in any considerable number before 12 weeks. By 15 weeks, the bone-tendon junction was almost, but not quite mature.

Our results support the use of a post-operative rehabilitation programme in man which protects the surgical repair for at least 12 to 15 weeks in order to allow maturation of tendon-to-bone healing.