Aims. This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized bone grafting, and percutaneous fixation. Methods. This was a retrospective analysis of 20 patients. All cases were delayed presentations (n = 15) or failed nonoperatively managed scaphoid fractures (n = 5). Surgery was performed at a mean duration of 27 months (7 to 120) following injury with arthroscopic debridement and arthroscopic iliac crest autograft. Fracture fixation was performed percutaneously with Kirschner (K)-wires in 12 wrists, a headless screw in six, and a combination of a headless screw and single K-wire in two. Clinical outcomes were assessed using grip strength, patient-reported outcome measures, and wrist range of motion (ROM) measurements. Results. Intraoperatively, established
The benefit of MRI in the preoperative assessment of scaphoid proximal fragment vascularity remains controversial. The purpose of this study is to compare preoperative MRI findings to intraoperative bleeding of the proximal scaphoid. A retrospective review of 102 patients who underwent surgery for scaphoid nonunion between January 2000 and December 2020 at a single institution were identified. Inclusion criteria were: isolated scaphoid nonunion; preoperative MRI assessing the proximal fragment vascularity; and operative details of the vascularity of the proximal fragment with the tourniquet deflated. MRI results and intraoperative findings were dichotomized as either ‘yes’ or ‘no’ for the presence of vascularity. A four-fold contingency table was used to analyze the utility of preoperative MRI with 95% confidence intervals. Relative risk was calculated for subgroups to analyze the association between variables and MRI accuracy.Aims
Methods
A conventional arthroscopic capsuloligamentous repair is a reliable surgical solution in most patients with scapholunate instability. However, this repair does not seem to be sufficient for more advanced injuries. The aim of this study was to evaluate the functional results of a wide arthroscopic dorsal capsuloligamentous repair (WADCLR) in the management of severe scapholunate instability. This was a prospective single-centre study undertaken between March 2019 and May 2021. The primary outcome was the evaluation of the reduction of the radiological deformity and the functional outcomes after WADCLR. A secondary outcome was the evaluation of the effectiveness of this technique in patients with the most severe instability (European Wrist Arthroscopy Society (EWAS) stage 5). The patients were reviewed postoperatively at three, six, and 12 months.Aims
Methods
We quantitatively compared the 3D bone density distributions on CT scans performed on scaphoid waist fractures subacutely that went on to union or nonunion, and assessed whether 2D CT evaluations correlate with 3D bone density evaluations. We constructed 3D models from 17 scaphoid waist fracture CTs performed between four to 18 weeks after fracture that did not unite (nonunion group), 17 age-matched scaphoid waist fracture CTs that healed (union group), and 17 age-matched control CTs without injury (control group). We measured the 3D bone density for the distal and proximal fragments relative to the triquetrum bone density and compared findings among the three groups. We then performed bone density measurements using 2D CT and evaluated the correlation with 3D bone densities. We identified the optimal cutoff with diagnostic values of the 2D method to predict nonunion with receiver operating characteristic (ROC) curves.Aims
Methods
Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion. Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed.Aims
Methods
Total wrist arthrodesis (TWA) produces a spectrum of outcomes.
We investigated this by reviewing 77 consecutive TWA performed for
inflammatory and post-traumatic arthropathies, wrist instability
and as a salvage procedure. All operations were performed by a single surgeon using a specifically
designed pre-contoured dorsally applied non-locking wrist arthrodesis
plate at a single centre. Aims
Patients and Methods