Aims. Disorders of bone integrity carry a high global disease burden, frequently requiring intervention, but there is a paucity of methods capable of noninvasive real-time
Background: Anterior cruciate ligament (ACL) injury and re-injury rates are high and continue to rise in adolescents. After surgical reconstruction, less than 50% of patients return to their pre-injury level of physical activity. Clearance for return-to-play and rehabilitation progression typically requires
The spinopelvic alignment is often assessed via the Pelvic Incidence-Lumbar Lordosis (PI-LL) mismatch. Here we describe and validate a simplified method to evaluating the spinopelvic alignment through the L1-Pelvis angle (L1P). This method is set to reduce the operator error and make the on-film measurement more practicable. 126 standing lateral radiographs of patients presenting for Total Hip Arthroplasty were examined. Three operators were recruited to label 6 landmarks. One operator repeated the landmark selection for intra-operator analysis. We compare PI-LL mismatch obtained via the conventional method, and our simplified method where we estimate this mismatch using PI-LL = L1P - 90°. We also assess the method's reliability and repeatability. We found no significant difference (p > 0.05) between the PI-LL mismatch from the conventional method (mean 0.22° ± 13.6) compared to L1P method (mean 0.0° ± 13.1). The overall average normalised root mean square error (NRMSE) for PI-LL mismatch across all operators is 7.53% (mean -3.3° ± 6.0) and 6.5% (mean -2.9° ± 4.9) for the conventional and L1P method, respectively. In relation to intra-operator repeatability, the correlation coefficients are 0.87 for PI, 0.94 for LL, and 0.96 for L1P. NRMSE between the two measurement sets are PI: 9.96%, LL: 5.97%, and L1P: 4.41%. A similar trend is observed in the absolute error between the two sets of measurements. Results indicate an equivalence in PI-LL measurement between the methods. Reproducibility of the measurements and reliability between operators were improved. Using the L1P angle, the classification of the sagittal spinal deformity found in the literature translates to: normal L1P<100°, mild 100°<L1P<110°, and severe L1P>110°. Surgeons adopting our method should expect a small improvement in reliability and repeatability of their measurements, and a significant improvement of the
Aims. The ongoing COVID-19 pandemic has disrupted and delayed medical and surgical examinations where attendance is required in person. Our article aims to outline the validity of online
This study aims to implement and assess the inter and intra-reliability of a modernised radiolucency
Abstract. Background. In 2018 NICE produced their guidelines with regards to the prevention of hospital-acquired thrombosis which extended the age range to include 16- and 17-years old patients, suggesting that these patients are risk assessed and receive thromboprophylaxis if indicated. We analysed the incidence of VTE in this age group in our institution and found it to be extremely low and often not related to risk factors commonly included in adult risk
Introduction. Limb deformity is usually assessed clinically assisted by long leg alignment radiographs and further imaging modalities (MRI and CT). Often decisions are made based on static imaging and simple gait interpretation in clinic. We have assessed the value of gait lab analysis in surgical decision making comparing surgical planning pre and post gait lab
Introduction. Intraoperative
The purpose of this study was to develop a quality appraisal tool for the
Limb symmetry on a battery of functional tests is becoming more common as a clinical rehabilitation tool serving as a proxy
Introduction. W. ide . A. wake . L. ocal . A. naesthetic . N. o . T. ourniquet (WALANT) is a well- established day case procedure for carpal tunnel release with several advantages and enhanced post-operative recovery. Use of Local anaesthesia with Adrenaline using a 27G needle allows a bloodless field and distraction techniques achieve patient comfort during the procedure. Objectives. This retrospective, observational cohort study assesses patient satisfaction and undertakes functional evaluation using the validated Boston Carpal Tunnel Questionnaire (BCTQ) following WALANT technique for carpal tunnel release (CTR). The BCTQ has a symptom severity scale based on 11 items and a functional status scale of 8 elements. Further we compare surgical outcomes between techniques of WALANT and traditional CTR. Patient and Methods. We included 30 consecutive patients, 15 in each arm who either underwent traditional CTR with the use of Tourniquet or with the WALANTtechnique. Data was collected from Electronic Patient Records and hand therapy
Although physical and ultrasound (US)-based screening for congenital deformities of the hip (developmental dysplasia of the hip, or DDH) is routinely performed in most countries, one of the most commonly performed manoeuvres done under ultrasound observation - dynamic
Introduction. Partial knee arthroplasty (PKA) has demonstrated the potential to improve patient satisfaction over total knee arthroplasty. It is however perceived as a more challenging procedure that requires precise adaptation to the complex mechanics of the knee. A recently developed PKA system aims to address these challenges by anatomical, compartment specific shapes and fine-tuned mechanical instrumentation. We investigated how closely this PKA system replicates the balance and kinematics of the intact knee. Materials and Methods. Eight post-mortem human knee specimens (age: 55±11 years, BMI: 23±5, 4 male, 4 female) underwent full leg CT scanning and comprehensive robotic (KUKA KR140 comp)
Introduction. Revision total hip arthroplasty is often associated with acetabular bone defects. In most cases,
Dynamic 2D sonography of the infant hip is a commonly used clinical procedure for developmental dysplasia of the hip (DDH) screening. It however has been found to be unreliable with some studies reporting associated misdiagnosis rates of up to 29%. In a recent systematic review, Charlton et al. examined dynamic ultrasound (US) screening for hip instability in the first six weeks after birth and found current best practices for such early screening techniques to be divergent between international institutions in terms of clinical scanning protocols. Such protocols include: the appropriate scanning plane and US probe position (e.g. coronal, transverse, lateral, anterior), DDH diagnostic metrics (e.g. femoral head coverage, alpha angle), appropriate patient age when scanning, and follow up procedures. To improve reliability of diagnosis and to help in standardizing diagnosis across different raters and health-centers, we propose an automated method for dynamically assessing hip instability using 3D US. 38 infant hips from 19 patients were scanned with B-mode 3D US by a paediatric orthopaedic surgeon and two technologists from the radiology department at a paediatric tertiary care centre. To quantify hip
Surgeons must explain the risk of complications to prospective patients and get informed consent. If a complication that occurred was omitted in the process or given the wrong risk level, culpability of the surgeon is judged in court against what a “reasonable patient” would like to know to give or refuse consent. ObjectivesThe concept “reasonable patient” is widely used, no attempt has been made to define it objectively. We assessed insight of patients, presumed “reasonable”, about risks of certain complications after they underwent one of five orthopaedic procedures. Questionnaire was administered with procedures: femur IMN, tibia IMN, ankle ORIF, distal radius ORIF and hip arthroplasty. Four common/serious complications were chosen per procedure, and matched against life events with documented risk levels. There were 230 participants 163 males and 67 females. We found 19.1% of patients above age 40 and 33.3% with tertiary education wouldn't accept nerve injury as reported in literature. With infection risk, 18.1% above 40 and 52.9% with pre-tertiary education would not accept. All patients below 40 and 7.4% pre-tertiary education wouldn't accept the risk of death as reported. However, 37.1% above 40 and 76.9% with pre-tertiary education would accept that risk at a higher level. It is hard to predict what risk of complication a patient may accept. This study highlights that some patients will not accept risks as reported in literature, even though they need the procedure. Therefore, surgeons need to explain complications fully, so that patients knowingly accepts or refuses consent. The subset of patients who are not willing to accept any level of risk, should be the subject of another study.
During a periacetabular osteotomy (PAO), intra-operative
Introduction. Procedure Based Assessments (PBAs) were recently introduced for orthopaedic trainees and play an increasing role in
The aim of this study was to determine the incidence, annual trend, perioperative outcomes, and identify risk factors of early-onset (≤ 90 days) deep surgical site infection (SSI) following primary total knee arthroplasty (TKA) for osteoarthritis. Risk factors for early-onset deep SSI were assessed. We performed a retrospective population-based cohort study using prospectively collected patient-level data from several provincial administrative data repositories between January 2013, and March 2020. The diagnosis of early-onset deep SSI was based on published Centre for Disease Control/National Healthcare Safety Network (CDC/NHSN) definitions. The Mann-Kendall Trend Test was used to detect monotonic trends in early-onset deep SSI rates over time. The effects of various patient and surgical risk factors for early-onset deep SSI were analyzed using multiple logistic regression. Secondary outcomes were 90-day mortality and 90-day readmission. A total of 20,580 patients underwent primary TKA for osteoarthritis. Forty patients had a confirmed deep SSI within 90-days of surgery representing a cumulative incidence of 0.19%. The annual infection rate did not change over the 7-year study period (p = 0.879). Risk factors associated with early-onset deep SSI included blood transfusions (OR, 3.93 [95% CI 1.34-9.20]; p=0.004), drug or alcohol abuse (OR, 4.91 [95% CI 1.85-10.93]; p<0.001), and surgeon volume less than 30 TKA per year (OR, 4.45 [1.07-12.43]; p=0.013). Early-onset deep SSI was not associated with 90-days mortality (OR, 11.68 [0.09-90-58]; p=0.217), but was associated with an increased chance of 90-day readmission (OR, 50.78 [26.47-102.02]; p<0.001). This study establishes a reliable baseline infection rate for early-onset deep SSI after TKA for osteoarthritis through the use of a robust methodological process. Several risk factors for early-onset deep SSI are potentially modifiable or can be optimized prior to surgery and be effective in reducing the incidence of early-onset SSI. This could guide the formulation of provincial screening programs and identify patients at high risk for SSI.
Abstract. Background. Cauda equina syndrome (CES) is a rare serious condition that, if missed at initial presentation, can lead to serious disability. Early diagnosis is crucial for a favourable outcome. Few studies included urodynamic test and measurement of post-void residual urine (PVR) as an adjunct screening tool for acute CES before proceeding to MRI scan, yet there are differences in the cut-off point as a threshold volume to be considered as a red flag for doing MRI amongst these studies. Aim. Meta-analysis and systematic review of literature that included PVR as a predictive tool in CES to identify the reliability of PVR and the optimal numerical value to be considered as red flag. Material & Methods. A comprehensive literature search was undertaken in PubMed, Medline, and Embase databases using our search strategy. Meta-analysis of collated data. Results. A total of seven studies were included with a total of 938 patients. The number of cases suitable for meta-analysis was 714. CES was confirmed in 73. urodynamic testing and PVR diagnosed 86 and excluded 426. The sensitivity of PVR>100ml was 64% (CI 97.5%: 0.44–0.80), specificity 59.2% (CI 97.5%: 0.46 – 0.711), while PVR >200 showed more predictive figures, with sensitivity improved to 83.1% (CI 97.5%: 0.62–0.94) and specificity to 93.5% (CI 97.5%: 0.50–0.99). Conclusions. Urodynamics test is an essential tool in CES