We report the outcome of 320 primary Total Hip
In this study we compare survivorship and patient reported outcome measures in robotically assisted versus conventional Total Hip Arthroplasty (THA). This paper investigates the hypothesis that implant survival and PROMS following THAs performed with robotic assistance were not different to outcomes following conventional THAs. Data included all patients undergoing THA for osteoarthritis between 19 April 2016 and 31 December 2020. Analysis of PROMS outcomes was restricted to those who had completed PROMS data preoperatively and at 6 months postoperatively. There were 157,647 procedures, including 3567 robotically assisted procedures, available for comparison of revision rates. 4557 procedures, including 130 robotically assisted procedures, had PROMS data available. The revision rate of primary THA performed with robotic assistance was not statistically different from THA performed by conventional methods (4 year cumulative percent revision 3.1% v 2.7%; HR = 1.05, p=0.67). The Oxford Hip Score, VAS for pain and the EQ-VAS score for overall health showed no statistically significant difference between the groups. The EQ-5D Utility Score showed an improved score (median score 1 v 0.88; OR = 1.58, p=0.007) for the robotically assisted group compared to the conventional group. Robotic assisted THA was not associated with significant improvement in early revision or joint-specific PROMs. The findings may have been biased, in either direction, by unmeasured patient, surgeon, hospital and prosthesis factors. The findings (including the difference in health-related quality of life) may have also been influenced by lack of blinding. Future research should include methods to minimise these biases.
Background. The current literature tends to suggest that all the different approaches used for Knee Arthroplasty give similar results. The literature also cautions that the MINI quadriceps sparing approaches are to be utilized in very select cases as they are difficult to perform, take longer time, have a greater intra-op complication rate and are associated with a higher number of component malpositioning. Despite these warnings of the literature, the author has been impressed by the physiological nature of the subvastus approach for knee arthrotomy and the author has used this approach exclusively for all Knee arthroplasties in the last 4 years. All primary Knee
In Canada, hip and knee replacements are each among the top three surgeries performed annually. In 2020, surgeries across the country were cancelled in response to the COVID-19 pandemic. We examined the impact on these joint replacement surgeries throughout the year. Using the Discharge Abstract Database and National Ambulatory Care Reporting System, we developed a dataset of all 208,041 hip and knee replacements performed in Canada (except from Quebec) between January 1, 2019 to December 31, 2020. We compared patient and surgical characteristics (including sex, age, main diagnosis, and type of surgery (planned/urgent, primary/revision, inpatient/day surgery) in 2020 to 2019. In 2020, hip and knee replacements volumes decreased by 18.8% compared to 2019. In April and May 2020, hip and knee replacements fell by 69.4% and 93.8%, respectively, compared to the same period in 2019. During those months, 66.5% of hip replacements were performed to treat hip fracture versus 20.2% in April and May 2019, and 64.5% of knee replacements were primaries versus 93.0% in April and May 2019. Patterns by patient age group and sex were similar compared to 2019. These patterns were similar across all provinces. By the summer, planned surgeries resumed across the country and volumes mostly returned to pre-pandemic monthly levels by the end of the year. We also found that there was an increase in the proportion of hip and knee replacements done as day surgery, with 4% in 2020 versus 1% in 2019, and patients undergoing day surgery replacement for osteoarthritis were older, with a median age of 64 for hip patients and 65 for knee patients, versus 63 for both joints the previous year. As a result of the COVID-19 pandemic, there was a notable drop in 2020 of hip and knee replacements performed in Canada. With the demand for joint replacements continuing to grow, the resulting backlog will have an immediate, significant impact on wait lists and patient quality of life. The shift to a greater proportion of joint replacements performed as day surgeries may have an effect on patient outcomes as well shifts in access to care. It will be important to continue monitor patient outcomes following day surgery and the impact on patients for which day surgery was not an option.
The purpose of this study is to assess the long term results of combined ACL reconstruction and unicompartmental knee replacements (UKR). These patients have been selected for this combined operation due to their combination of instability symptoms from an absent ACL and unicompartmental arthritis. Retrospective review of 44 combined UKR and ACL reconstruction by a single surgeon. Surgeries included both medial and lateral UKR combined with either revision ACL reconstruction or primary ACL reconstruction. Patient reported outcomes were obtained preoperatively, at one year, 5 years and 10 years. Revision rate was followed up over 13 years for a mean of 7.4 years post-surgery. The average Oxford score at one year was 43 with an average increase from pre-operation to 1 year post operation of 15. For the 7 patients with 10 year follow up average oxford score was 42 at 1 year, 43 at 5 years and 45 at 10 years. There were 5 reoperations. 2 for revision to total knee arthroplasty and 1 for an exchange of bearing due to wear. The other 2 were the addition of another UKR. For those requiring reoperation the average time was 8 years. Younger more active patients presenting with ACL deficiency causing instability and unicompartmental arthritis are a difficult group to manage. Combining UKR and ACL reconstruction has scant evidence in regard to long term follow up but is a viable option for this select group. This paper has one of the largest cohorts with a reasonable follow up averaging 7.4 years and a revision rate of 11 percent. Combined unilateral knee replacements and ACL reconstruction can be a successful operation for patients with ACL rupture causing instability and unicompartmental arthritis.
Due to shorter hospital stays and faster patient rehabilitation Unicompartmental Knee Replacements (UKR) are now considered more cost effective than Total Knee Joint Replacements (TKJR). Obesity however, has long been thought of as a relative contraindication to UKR due to an unproven theoretical concern of early loosening. This study is a retrospective review of patient reported outcome scores and revision rates of all UKR with recorded BMI performed by the Canterbury District Health Board (CDHB) from January 2011 and September 2021. Patient reported outcome scores were taken preoperatively, at 6 months, 1 year, 5 years and 10 years post operatively. These included WOMAC, Oxford, HAAS, UCLA, WHOQOL, normality, pain and patient satisfaction. 873 patients had functional scores recorded at 5 years and 164 patients had scores recorded at 10 years. Further sub-group analysis was performed based on patient BMI of <25, 25–30, 30–35 and >35. Revision data was available for 2377 UKRs performed in Christchurch during this period. Both obese (BMI >30) and non-obese (BMI <30) patients had significantly improved post-operative scores compared to preoperative. Pre-operatively obese patients had significantly lower functional scores except for pain and UCLA. All functional scores were lower in obese patients at 5 years but this did not meet minimum clinical difference. At 10 years, there was significantly lower HAAS, satisfaction and WOMAC scores for obese patients but no difference in Oxford, normality, WHOQOL, UCLA and pain scores. There was no significant difference in the improvement from pre-operative scores between obese and non-obese patients. All cause revision rate for obese patients at 10 years was 0.69 per 100 observed component years compared to 0.76 in non-obese. This was not statistically significant. Our study proves that UKR is an excellent option in obese patients with post-operative improvement in functional scores and 10 year survivorship equivalent to non-obese patients.
The aim of this study was to investigate the clinical relevance of an isolated positive sonication fluid culture (SFC) in patients who underwent revision surgery of a prosthetic joint. We hypothesized that cases with a positive SFC have a higher rate of infection and prosthesis failure during follow-up compared to controls with a negative SFC. This retrospective multicentre observational study was performed within the European Study Group of Implant-Associated Infections (ESGIAI). All patients who underwent revision surgery of a prosthetic joint between 2013 and 2019 and had a minimum follow-up of 1 year were included. Patients with positive tissue cultures or synovial fluid cultures were excluded from the study.Aim
Method
Direct anterior approach (DAA) arthroplasty has generated great interest because of its minimally invasive and muscle sparing nature. Obese patients are reported to be associated with greater incidence of complications in primary joint replacement. The purpose of this study was to compare patient outcomes and complication rates between obese and non-obese patients undergoing primary total hip arthroplasty (THA) through a Bikini direct anterior incision. This retrospective, single surgeon study compared the outcome of 258 obese patients and 200 non-obese patients undergoing DAA THA using a Bikini incision, over a 7-year period. The average follow-up was 4.2 years (range 2.6-7.6 years). There were no statistically significant differences in the complication rate between the two groups. The obese group recorded 2 major (venous thromboembolism and peri-prosthetic fracture) and 2 minor complications (superficial wound infection), compared with the non-obese group, which recorded 2 major (deep-wound infection and peri-prosthetic fracture) and 1 minor complication (superficial wound infection). Patient-reported outcomes (WOMAC and Harris Hip Scores) showed significant post-operative improvements (p < 0.001) and did not differ between the two groups. Bikini DDA THA does not increase the complication rate in obese patients and offers similar clinical improvements compared to non-obese patients. (200 words)
In recent years, ‘Get It Right First Time (GIRFT)’ have advocated cemented replacements in femoral part of Total hip arthroplasty (THA) especially in older patients. However, many studies were unable to show any difference in outcomes and although cemented prostheses may be associated with better short-term pain outcomes there is no clear advantage in the longer term. It is not clear when and why to do cemented instead of cementless. To assess differences in patient reported outcomes in uncemented THAs based on patient demographics in order to decide when cementless THA can be done safely.Background
Aim
Our objective was to examine revision rates and patient reported outcome scores (PROMS) for cemented and uncemented primary total knee joint replacement (TKJR) at six months, one year and five years post-operatively. Patients and Methods: This matched cohort study involved secondary analyses of data collected as part of a large prospective observational study monitoring outcomes following knee replacement in Christchurch, New Zealand. Cemented and uncemented TKJR participants (n = 1526) were matched on age (± 5 years), sex and body mass index (BMI). From this larger sample, PROMS data, Oxford Knee Score and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), out to five years post-operatively were analysed for a matched subset of participants (n = 252). The average age of participants was 67.9 years (SD 9.4, range 38-94). There were no differences between cemented and uncemented cohorts on the basis of age, sex, BMI or comorbidities, revision rates or PROMS outcomes. Cemented procedures had greater skin to skin times than uncemented procedures (p < 0.01). Unadjusted outcomes comparing risk for revision across the two participant cohorts did not significantly differ. Overall rates for revision were low (cemented 3.2% v uncemented 2.7%, p=0.70). Propensity adjusted associations between baseline characteristics (age, sex, BMI, comorbidity, baseline Oxford and baseline WOMAC scores) also revealed no differences in risk for revision at any post-operative timepoint. In this large multi-surgeon matched cohort study there were no significant differences in functional outcomes or revision rates, when outcomes following modern cemented and uncemented TKJR were compared out to 5-year follow up. Based on our findings, uncemented TKJR is predictable irrespective of patient's age, BMI or gender
Deep infection is a devastating complication of total knee arthroplasty (TKA). This study aimed to determine if there was a relationship between surgeon volume and the incidence of revision for infection after primary TKA. Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1 September 1999 to 31 December 2020 for primary TKA for osteoarthritis that were revised for infection. Surgeon volume was defined by the number of primary TKA procedures performed by the surgeon in the year the primary TKA was performed and grouped as <25, 25-49, 50-74, 75-99, >100 primary TKA procedures per year. Kaplan Meir estimates for cumulative percent revision (CPR) and Cox Proportional Hazard Ratios were performed to compare rates of revision for infection by surgeon volume, with sub-analyses for patella and polyethylene use, age <65 years and male gender. 5295 of 602,919 primary TKA for osteoarthritis were revised for infection. High volume surgeons (>100 TKA/year) had a significantly lower rate of revision for infection with a CPR at 1 and 17 years of 0.4% (95% CI 0.3, 0.4) and 1.5% (95% CI 1.2, 2.0), respectively, compared with 0.6% (95% CI 0.5, 0.7) and 2.1% (95% CI 1.8, 2.3), respectively, for low volume surgeons (<25 TKR/year). Differences between the high-volume group and the remaining groups remained when sub-analysis for age, gender, ASA, BMI, patella resurfacing and the use of cross-linked polyethylene (XLPE). High volume surgeons have lower rates of revision for infection in primary TKA.
To date, the value of culture results after a debridement, antibiotics and implant retention (DAIR) for early (suspected) prosthetic joint infection (PJI) as risk indicators in terms of prosthesis retention is not clear. At one year follow-up, the relative risk of prosthesis removal was determined for culture-positive and culture-negative DAIRs after primary total hip or knee arthroplasty. The secondary aim was to explore differences in patient characteristics, infection characteristics and outcomes between these two groups. A retrospective regional registry study was performed in a group of 359 patients (positive cultures: n = 299, negative cultures n = 60) undergoing DAIR for high suspicion of early PJI in the period from 2014 to 2019. Differences in patient characteristics, deceased patients and number of subsequent DAIRs between the positive and negative DAIR groups were analyzed using independent t-tests, Mann-Whitney, Pearson's Chi-square tests and Fisher's Exact tests.Aim
Methods
Unexpected-positive-intraoperative-cultures (UPIC) in presumed aseptic revision-total-knee-arthroplasties (rTKA) are common, and the clinical significance is not entirely clear. In contrast, in some presumably septic rTKA, an identification of an underlying pathogen was not possible, so called unexpected-negative-intraoperative-cultures (UNIC). The purpose of this study was to evaluate alpha defensin (AD) levels in these patient populations. In this retrospective analysis of our prospectively maintained biobank, we evaluated synovial AD levels from 143 rTKAs. The 2018-Musculoskeletal Infection Society score (MSIS) was used to define our study groups. Overall, 20 rTKA with UPIC with a minimum of one positive intraoperative culture with MSIS 2-≥6 and 14 UNIC samples with MSIS≥6 were compared to 34 septic culture-positive samples (MSIS ≥6) and 75 aseptic culture-negative (MSIS 0–1) rTKAs. Moreover, we compared the performance of both AD-lateral-flow-assay (ADLF) and an enzyme-linked-immunosorbent-assay (ELISA) to test the presence of AD in native and centrifuged synovial fluid. Concentration of AD determined by ELISA and ADLF methods, as well as microbiological, and histopathological results, serum and synovial parameters along with demographic factors were considered.Purpose
Methods
Recent advances in arthroplasty for the hip and the knee have motivated modern foot and ankle research to perfect the implant and technique for the optimal total ankle replacement. Unlike in the hip where different approaches can be done with similar implants, the approach of a total ankle is intimately associated to the prosthetic design. The anterior and lateral approaches have pros and cons regarding their respective soft tissue complications, osteotomy necessity, orientation of the bone cut and gutter visualization. While both have been studied independently, very few reports have compared both in the same setting. This study retrospectively looked at the difference in reoperations rate after each ankle arthroplasty within two years estimating that both had similar rate of return to the operating room. A retrospective study was conducted from a single center between 2014 and 2017 including a total of 115 total ankles performed by one of four fellowship-trained foot and ankle surgeon. Re-operations were reported in the charts as an operative report. The index approach used was determined by the surgeon's practice preference. Patients were included when they had a primary TAR in the timeframe noted and had a complete dataset up to at least the two-year data. This cohort comprised 67 anterior and 48 lateral with balanced demographic for age (95%CI 63–67 yo) and gender (47% F). The lateral group had more complex cases with higher COFAS type arthritis. Comparing the two groups, a total of 40 reoperations (7 anterior, 33 lateral) occurred in 27 patients (5A, 22L). One patient had up to four related reoperations. The only revision was in the anterior group. The only soft tissue reconstruction was an STSG in the lateral group. Nine reoperations were irrigation debridement related to an infective process (3 A, 6L). The majority (19/33) of reoperations in the lateral group were gutter debridement (8) or lateral hardware removal (11). Operative time was not statistically different. The odds ratio of having a reoperation with a laterally based TAR was 6.19 compared to the anterior group. This retrospective study outlines the intermediate results at two years of lateral and anterior total ankle replacements. This is a first study of this kind in the literature. This study did show that there were more reoperations after a laterally-based TAR than an anterior TAR, recognizing the significant case complexity imbalance between groups. This speaks to the relative increase resource utilization of laterally based TAR patients. Both implant designs carry different reoperation rates favoring the anterior group however larger prospective datasets will be needed with patient-reported outcome.
Strategy regarding patella resurfacing in total knee replacement (TKR) remains controversial. TKR revision rates are reportedly influenced by surgeon procedure volume. The study aim was to compare revision outcomes of TKR with and without patella resurfacing in different surgeon volume groups using data from the AOANJRR. The study population included 571,149 primary TKRs for osteoarthritis. Surgeons were classified as low, medium, or high-volume based on the quartiles of mean primary TKR volume between 2011 and 2020. Cumulative percent revision (CPR) using Kaplan-Meier estimates of survivorship were calculated for the three surgeon volume groups with and without patella resurfacing. Cox proportional hazards models, adjusted for age and sex, were used to compare revision risks. High-volume surgeons who did not resurface the patella had the highest all-cause CPR (20-year CPR 10.9%, 95% CI [10.0%, 12.0%]). When the patella was resurfaced, high-volume surgeons had the lowest revision rate (7.3%, 95% CI [6.4%, 8.4%]). When the high-volume groups were compared there was a higher rate of revision for the non-resurfaced group after 6 months. When the medium-volume surgeon groups were compared, not resurfacing the patella also was associated with a higher rate of revision after 3 months. The low-volume comparisons showed an initial higher rate of revision with patella resurfacing, but there was no difference after 3 months. When only patella revisions were considered, there were higher rates of revision in all three volume groups where the patella was not resurfaced. TKR performed by high and medium-volume surgeons without patella resurfacing had higher revision rates compared to when the patella was resurfaced. Resurfacing the patella in the primary procedure protected against revision for patella reasons in all surgeon volume groups.
The specific factors affecting wear of the ultrahigh molecular weight polyethylene (UHMWPE) tibial component of total knee replacements (TKR) are poorly understood. One recent study demonstrated that lower conforming inserts produced less wear in knee simulators. The purpose of this study is to investigate the effect of insert conformity and design on articular surface wear of postmortem retrieved UHMWPE tibial inserts. Nineteen NexGen cruciate-retaining (NexGen CR) and twenty-five NexGen posterior-stabilized (NexGen PS) (Zimmer) UHWMPE tibial inserts were retrieved at postmortem from fifteen and eighteen patients respectively. Articular surfaces were scanned at 100×100μm using a coordinate measuring machine (SmartScope, OGP Inc.). Autonomous mathematical reconstruction of the original surface was used to calculate volume loss and linear penetration maps of the medial and lateral plateaus. Wear rates for the medial, lateral and total articular surface were calculated as the slope of the linear regression line of volume loss against implantation time. Volume loss due to creep was estimated as the regression intercept. Student t-tests were used to check for significant.INTRODUCTION
METHODS
As life expectancy increases, the number of octogenarians requiring primary and revision total knee arthroplasty (TKA) is increasing. Recently, primary TKA has become a common treatment option in octogenarians. However, surgeons are still hesitant about performing revision TKA on octogenarians because of concerning about risk- and cost-benefit. The purpose of this study was to investigate postoperative complications and mid-term survival in octogenarians following primary and revision total knee arthroplasty (TKA). We retrospectively reviewed 231 primary TKAs and 41 revision TKAs performed on octogenarians between 2000 and 2016. The mean age was 81.9 for primary TKA and 82.3 for revision TKA (p=0.310). The American Society of Anesthesiologists (ASA) score was not different, but the age-adjusted Charlson comorbidity index was higher in revision TKA (4.4 vs. 4.8, p=0.003). The mean follow-up period did not differ (3.8 vs. 3.5 years, p=0.451). The WOMAC scores and range of motion (ROM) were evaluated. The incidence of postoperative complication and survival rate (end point; death determined by telephone or mail communication with patient or family) were investigated.Background
Methods
The interaction between the mobile components of total elbow replacements (TER) provides additional constraint to the elbow motion. Semi-constrained TER depend on a mechanical linkage to avoid dislocation and have greater constraint than unconstrained TER that rely primarily in soft tissue for joint stability. Greater constraint increases the load transfer to the implant interfaces and the stresses in the polyethylene components. Both of these phenomena are detrimental to the longevity of TER, as they may result in implant loosening and increased damage to the polyethylene components, respectively[1]. The objective of this work was to compare the constraint profile in varus-valgus and internal-external rotation and the polyethylene stresses under loads from a common daily activity between two semi-constrained TER, Coonrad/Morrey (Zimmer-Biomet) and Discovery® (DJO), and an unconstrained TER, TEMA (LimaCorporate). We developed finite element (FE) models of the three TER mechanisms. To reduce computational cost, we did not include the humeral and ulnar stems. Materials were linear-elastic for the metallic components (ETi6Al4V=114.3 GPa, ECoCr=210 GPa, v=0.33) and linear elastic-plastic for the polyethylene components (E=618 MPa, v=0.46; SY=22 MPa; SU=230.6 MPa; εU=1.5 mm/mm). The models were meshed with linear tetrahedral elements of sizes 0.4–0.6 mm. We assumed a friction coefficient of 0.02 between metal and polyethylene. In all simulations, the ulnar component was fixed and the humeral component loaded. We computed the constraint profiles in full extension by simulating each mechanism from 8° varus to 8° valgus and from 8° internal to 8° external rotation. All other degrees-of-freedom except for flexion extension were unconstrained. Then, we identified the instant during feeding that generated the highest moments at the elbow[2], and we applied the joint forces and moments to each TER to evaluate the stresses in the polyethylene. To validate the FE results, we experimentally evaluated the constraint of the design with highest polyethylene stresses in pure internal-external rotation and compared the results against those from a FE model that reproduced the experimental setup (Fig.1-a).Introduction
Methods
Strenuous efforts to minimize postoperative infection rates have been made, including the Swedish nation-wide initiative Prosthesis Related Infections Shall be Stopped (PRISS). The aim of this study was to calculate the incidence rate of periprosthetic joint infections (PJI) following primary total knee arthroplasty (TKA) before and after PRISS. All 45,438 primary TKAs registered in the Swedish knee arthroplasty register (SKAR) during 2007–2008 and 2012–2013 were included. Matched data on antibiotic prescriptions were obtained from the Swedish Prescribed Drug Register (SPDR). All patients with ≥28 days of continuous antibiotic treatment within 2 years of primary surgery had their medical charts reviewed to identify cases of PJI.Aim
Method
Glenoid failure remains the most common mode of total shoulder arthroplasty failures. Porous tantalum metal (Trabecular Metal™, Zimmer) have grown in popularity in hip and knee arthroplasty. First-generation porous tantalum metal-backed glenoid components demonstrated metal debris, resulted in failure, and were revised to second-generation glenoid implants. Evidence for second-generation porous tantalum metal implants in shoulder arthroplasty is sparse.1–4 The purpose of this study was to assess clinical and radiographic outcomes in a series of patients with second-generation porous tantalum glenoid components at a minimum two-years postoperative. We retrospectively reviewed the clinical and radiographic outcomes of patients who received a second-generation porous tantalum glenoid component anatomic shoulder arthroplasty between May 2009 and December 2017 with minimum 24 months follow-up. The shoulder arthroplasties were performed by one of two senior fellowship-trained surgeons. We collected postoperative clinical outcome indicators: EQ5D visual analog scale (VAS), Western Ontario Osteoarthritis of the Shoulder (WOOS) Index, American Shoulder and Elbow Surgeons (ASES) Score, and Constant Score (CS). Radiographic review was performed by an independent fellowship-trained surgeon. The Endrizzi metal debris grading system1 was utilized to grade metal debris. We computed descriptive statistics and compared outcome scores between groups via the non-parametric Wilcoxon rank-sum test, with group-wise comparisons defined by: metal debris and humeral head migration (secondary analyses). Thirty-five patients [23 male (65.7%) and 12 female (34.3%)] with 40 shoulder replacements participated in the study. Forty of 61 shoulders (65.6%) had an average of 64 ± 20.3 months follow-up (range 31 to 95). Average BMI was 27.5 ± 4.4 kg/m2 (range 19.5 to 39.1). The average postoperative EQ5D VAS at final follow-up was 74.6 ± 22.5, WOOS Index 87.9 ± 16.6, ASES Score 88.3 ± 10.9, and CS 80.4 ± 13. At final follow-up, 18 of 40 shoulders (45%) had metal debris [15 of 40 (37.5%) Endrizzi grade 1 and three of 40 (7.5%) Endrizzi grade 2], and 22 of 40 shoulders (55%) did not show evidence of metal debris. There was one non-revision reoperation (open subscapularis exploration), one shoulder with anterosuperior escape, three shoulders with glenoid radiolucencies indicative of possible glenoid loosening, and nine shoulders with superior migration of the humeral head (>2mm migration at final follow-up compared to immediate postoperative). When comparing postoperative scores between patients with vs without metal debris, we found no statistically significant difference in the EQ5D VAS, WOOS Index, ASES Score and CS. On further analyses, when comparing superior migration of the humeral head and postoperative outcomes scores, we found no statistically significant difference. We report the longest published follow-up with clinical and radiographic outcomes of second-generation porous tantalum glenoid anatomic shoulder arthroplasties. In this series of patients, 45% of total shoulder arthroplasties with a second-generation porous tantalum glenoid implant had radiographic evidence of metal debris. This metal debris was not statistically associated with poorer postoperative outcomes. Further investigation and ongoing follow-up are warranted.