Advertisement for orthosearch.org.uk
Results 1 - 9 of 9
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 22 - 22
1 Dec 2016
Degen R Garcia G Bui C McGarry M Lee T Dines J
Full Access

Acute Hill-Sachs (HS) reduction represents a potential alternative method to remplissage for the treatment of an engaging HS lesion. The purpose of this study is to biomechanically compare the stabilising effects of a acute HS reduction technique and remplissage in a complex instability model.

This was a comparative cadaveric study of 6 shoulders. For the acute HS lesion, a unique model was used to create a 30% defect, compressing the subchondral bone while preserving the articular surface in a more anatomic fashion. In addition, a 15% glenoid defect was made in all specimens. The HS lesion was reduced through a lateral cortical window with a bone tamp, and the subchondral void was filled with Quickset (Arthrex) bone cement to prevent plastic deformation. Five scenarios were tested; intact specimen, bipolar lesion, Bankart repair, remplissage with Bankart repair and HS reduction technique with Bankart repair. Translation, kinematics and dislocation events were recorded.

For all 6 specimens no dislocations occurred after either remplissage or the reduction technique. At 90 degrees of abduction and external rotation (ABER), anterior-inferior translation was 11.1 mm (SD 0.9) for the bipolar lesion. This was significantly reduced following both remplissage (5.1±0.7mm; p<0.001) and HS reduction (4.4±0.3mm; p<0.001). For anterior-inferior translation there was no significant difference in translation between the reduction technique and remplissage (p=0.91). At 90 degrees of ABER, the intact specimens average joint stiffness was 7.0±1.0N/mm, which was not significantly different from the remplissage (7.8±0.9 N/mm; p=0.9) and reduction technique (9.1±0.6 N/mm; p=0.50). Compared with an isolated Bankart repair, the average external rotation loss after also performing a remplissage procedure was 4.3±3.5 deg (p=0.65), while average ER loss following HS reduction was 1.1±3.3 deg (p=0.99). There was no significant difference in external rotation between remplissage and the reduction technique (p=0.83).

Similar joint stability was conferred following both procedures, though remplissage had 3.2-degree loss of ER in comparison. While not statistically significant, even slight ER loss may be clinically detrimental in overhead athletes. Overall, the acute reduction technique is a more anatomic alternative to the remplissage procedure with similar ability to prevent dislocation in a biomechanical model, making it a viable treatment option for engaging Hill-Sachs lesions.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 41 - 41
23 Feb 2023
Bekhit P Saffi M Hong N Hong T
Full Access

Acromial morphology has been implicated as a risk factor for unidirectional posterior shoulder instability. Studies utilising plain film radiographic landmarks have identified an increased risk of posterior shoulder dislocation in patients with higher acromion positioning. The aims of this study were to develop a reproducible method of measuring this relationship on cross sectional imaging and to evaluate acromial morphology in patients with and without unidirectional posterior shoulder instability. We analysed 24 patients with unidirectional posterior instability. These were sex and age matched with 61 patients with unidirectional anterior instability, as well as a control group of 76 patients with no instability. Sagittal T1 weighted MRI sequences were used to measure posterior acromial height relative to the scapular body axis (SBA) and long head of triceps insertion axis (LTI). Two observers measured each method for inter-observer reliability, and the intraclass correlation coefficient (ICC) calculated. LTI method showed good inter-observer reliability with an ICC of 0.79. The SBA method was not reproducible due suboptimal MRI sequences. Mean posterior acromial height was significantly greater in the posterior instability group (14.2mm) compared to the anterior instability group (7.7mm, p=0.0002) as well when compared with the control group (7.0mm, p<0.0001). A threshold of 7.5mm demonstrated a significant increase in the incidence of posterior shoulder instability (RR = 9.4). We conclude that increased posterior acromial height is significantly associated with posterior shoulder instability. This suggests that the acromion has a role as an osseous restraint to posterior shoulder instability


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 2 - 2
1 Nov 2015
Romeo A
Full Access

The Hill-Sachs lesion is a bony defect of the humeral head that occurs in association with anterior instability of the glenohumeral joint. Hill-Sachs lesions are common, with an incidence approaching nearly 100% in the setting of recurrent anterior glenohumeral instability. However, the indications for surgical management are very limited, with less than 10% of anterior instability patients considered for treatment of the Hill-Sachs lesion. Of utmost importance is addressing bone loss on the anterior-inferior glenoid, which is highly successful at preventing recurrence of instability even with humeral bone loss. In the rare situation where the Hill-Sachs lesion may continue to engage the glenoid, surgical management is indicated. Surgical strategies are variable, including debridement, arthroscopic remplissage, allograft transplantation, surface replacement, and arthroplasty. Given that the population with these defects is typically comprised of young and athletic patients, biologic solutions are most likely to be associated with decades of sustainable joint preservation, function, and stability. The first priority is maximizing the treatment of anterior instability on the glenoid side. Then, small lesions of less than 10% are ignored without consequence. Lesions involving 10–20% of the humeral head are treated with arthroscopic remplissage (defect filled with repair of capsule and infraspinatus). Lesions greater than 20% that extend beyond the glenoid tract are managed with fresh osteochondral allografts to biologically restore the humeral head. Lesions great than 40% are most commonly associated with advanced arthritis and deformity of the humeral articular surface and are therefore treated with a humeral head replacement. This treatment algorithm maximises our ability to stabilise and preserve the glenohumeral joint


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 2 - 2
1 Jul 2014
Romeo A
Full Access

The Hill-Sachs lesion is a bony defect of the humeral head that occurs in association with anterior instability of the glenohumeral joint. Hill-Sachs lesions are common, with an incidence approaching nearly 100% in the setting of recurrent anterior glenohumeral instability. However, the indications for surgical management are very limited, with less than 10% of anterior instability patients considered for treatment of the Hill-Sachs lesion. Of utmost importance is addressing bone loss on the anterior-inferior glenoid, which is highly successful at preventing recurrence of instability even with humeral bone loss. In the rare situation where the Hill-Sachs lesion may continue to engage the glenoid, surgical management is indicated. Surgical strategies are variable, including debridement, arthroscopic remplissage, allograft transplantation, surface replacement, and arthroplasty. Given that the population with these defects is typically comprised of young and athletic patients, biologic solutions are most likely to be associated with decades of sustainable joint preservation, function, and stability. The first priority is maximising the treatment of anterior instability on the glenoid side. Then, small lesions of less than 10% are ignored without consequence. Lesions involving 10–20% of the humeral head are treated with arthroscopic remplissage (defect filled with repair of capsule and infraspinatus). Lesions greater than 20% that extend beyond the glenoid tract are managed with fresh osteochondral allografts to biologically restore the humeral head. Lesions great than 40% are most commonly associated with advanced arthritis and deformity of the humeral articular surface and are therefore treated with a humeral head replacement. This treatment algorithm maximises our ability to stabilise and preserve the glenohumeral joint


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 19 - 19
1 Nov 2017
Edwin J Morris D Ahmed S Gooding B Manning P
Full Access

The shoulder is the least constrained of all joints of the body and is more susceptible to injury including dislocation. The rate of recurrent instability following primary stabilization procedure at 10 years of follow-up ranged from 3.4 to 35 %. We describe the outcomes of 74 patients who underwent knotless arthroscopic anterior stabilisation using 1.5 mm Labral Tape with 2.9mm Pushlock anchors for primary anterior instability. We performed a retrospective analysis of patients who underwent surgery for post-traumatic recurrent anterior instability for 2 years by a single surgeon. Patients with glenoid bone loss, >25% Hill Sachs lesion, posterior dislocation, paediatric age group and multidirectional instability were excluded from this study. Over 90% of our case mix underwent the procedure under regional block anaesthesia and was discharged on the same day. The surgical technique and post-operative physiotherapy was as per standard protocol. Outcomes were measured at 6 months and 12 months. Of the 74 patients in our study, we lost 5 patients to follow up. Outcomes were measured using the Oxford Shoulder Score apart from clinical assessment including the range of motion. We noted good to excellent outcomes in 66 cases using the Oxford Instability Scores. All patients achieved almost full range of motion at the end of one year. Our cumulative Oxford Instability Score (OIS) preoperatively was 24.72 and postoperatively was 43.09. The Pearson correlation was .28. The t Critical two-tail was 2.07 observing the difference between the means of the OIS. Complications included recurrent dislocation in 2 patients following re-injury and failure of procedure due to recurrent instability requiring an open bone block procedure in one case. We had no reported failures due to knot slippage or anchor pull-out. We publish the largest case series using this implant with distinct advantages of combining a small bio absorbable implant with flat braided, and high-strength polyethylene tape to diminish the concern for knot migration and abrasive chondral injury with the potential for earlier rehabilitation and a wider footprint of labral compression with comparative outcomes using standard techniques. Our results demonstrate comparable and superior results to conventional suture knot techniques for labral stabilization


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 100 - 100
1 Aug 2013
Nakamura N Iwana D Kitada M Maeda Y Sakai T
Full Access

The occurrence of impingement can lead to instability, accelerated wear, and unexplained pain after THA. While implant and bony impingement were widely investigated, importance of soft tissue impingement was unclear. In the THA through posterior approach, it is known that posterior soft tissue repair can decrease the risk of dislocation. However, it is not known whether anterior soft tissue impingement by anterior hip capsule will influence hip ROM. The purpose of this study is to quantitatively measure the effect of anterior capsule resection on hip ROM in vivo during posterior approach THA using hip navigation system. From June 2011, 26 hips (25 patients) that underwent primary THA using Stryker CT-based hip navigation system were the subjects. All were female osteoarthritis patients and the average age at the operation was 59 (47–76) years. Intraoperatively, acetabular cup and femoral stem placement were performed through posterior approach under the navigation system. After reduction of the joint, we measured hip ROM using the same navigation system. We measured them before and after the resection of anterior hip capsule and compared the difference. After the resection of anterior hip capsule, the average increases of ROM were 0.7±3.5 degrees for flexion, 2.3±2.3 degrees for extension, 1.1±2.3 degrees for abduction and 2.1±2.9 degrees for external rotation at flexion 0 degree compared with ROM before the resection. However, it significantly increased 7.5±5.1 degrees for internal rotation at flexion 90 degree (range; −3–20, paired t-test p<0.001) and 6.1±5.5 degrees for internal rotation at flexion 45 degree (range; −4–18, p<0.001). In this study, we used navigation system for assessment of soft tissue impingement. We found that during posterior approach THA, resection of anterior hip capsule brought about significant increase of ROM, especially in the direction of flexion with internal rotation. We also found that this procedure did not change ROM of flexion, extension, abduction and external rotation. These results indicated that, during THA through posterior approach, resection of anterior hip capsule could reduce the risk of posterior instability without increasing the risk of anterior instability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 87 - 87
1 Nov 2016
Matz J Morden D Teeter M McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Howard J Lanting B
Full Access

Complications involving the patellofemoral joint are a source of anterior knee pain, instability, and dysfunction following total knee arthroplasty. “Overstuffing” the patello-femoral joint refers to an increase in the thickness of the patellofemoral joint after a total knee replacement compared to the preoperative thickness. While biomechanical studies have indicated that overstuffing the patellofemoral joint may lead to adverse clinical outcomes, limited clinical evidence exists to support this notion. The purpose of this study is to evaluate the effect of changing the thickness of the patellafemoral joint on functional outcomes following total knee arthroplasty. Our institutional arthroplasty database was used to identify 1347 patients who underwent a primary total knee arthroplasty between 2006 and 2012 with the same component design. Standard preoperative and postoperative anteroposterior, lateral, and skyline radiographs were collected and measured for patello-femoral overstuffing. These measurements included anterior patellar displacement, anterior femoral offset, and anteroposterior femoral size. These measurements were correlated with patient outcome data using WOMAC, KSS scores, and postoperative range of motion. Multiple linear regression analysis was used to assess the association between stuffing and functional outcomes. A total of 1031 patients who underwent total knee arthroplasty were included. Increased anterior patellar displacement, a measure of patellofemoral joint thickness, was associated with decreased WOMAC scores (p=0.02). Anterior femoral offset (p=0.210) and anteroposterior femoral size (p=0.091) were not significantly associated with patient functional outcomes. Postoperative range of motion (ROM) was not associated with patellofemoral stuffing (p=0.190). The current study demonstrated that functional outcomes are adversely affected by patellofemoral overstuffing. Based on these results, caution is encouraged against increasing the thickness of the patellofemoral joint, particularly on the patellar side of the joint


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 115 - 115
1 Mar 2017
Riviere C Shah H Howell S Aframian A Iranpour F Auvinet E Cobb J Harris S
Full Access

BACKGROUND. Trochlear geometry of modern femoral implants is designed for the mechanical alignment (MA) technique for Total Knee Arthroplasty (TKA). The biomechanical goal is to create a proximalised and more valgus trochlea to better capture the patella and optimize tracking. In contrast, Kinematic alignment (KA) technique for TKA respects the integrity of the soft tissue envelope and therefore aims to restore native articular surfaces, either femoro-tibial or femoro-patellar. Consequently, it is possible that current implant designs are not suitable for restoring patient specific trochlea anatomy when they are implanted using the kinematic technique. This could cause patellar complications, either anterior knee pain, instability or accelerated wear or loosening. The aim of our study is therefore to explore the extent to which native trochlear geometry is restored when the Persona. ®. implant (Zimmer, Warsaw, USA) is kinematically aligned. METHODS. A retrospective study of a cohort of 15 patients with KA-TKA was performed with the Persona. ®. prosthesis (Zimmer, Warsaw, USA). Preoperative knee MRIs and postoperative knee CTs were segmented to create 3D femoral models. MRI and CT segmentation used Materialise Mimics® and Acrobot Modeller® software, respectively. Persona. ®. implants were laser-scanned to generate 3D implant models. Those implant models have been overlaid on the 3D femoral implant model (generated via segmentation of postoperative CTs) to replicate, in silico, the alignment of the implant on the post-operative bone and to reproduce in the computer models the features of the implant lost due to CT metal artefacts. 3D models generated from post-operative CT and pre-operative MRI were registered to the same coordinate geometry. A custom written planner was used to align the implant, as located on the CT, onto the pre-operative MRI based model (figure 1). In house software enabled a comparison of trochlea parameters between the native trochlea and the performed prosthetic trochlea (figure 2). Parameters assessed included 3D trochlear axis and anteroposterior offset from medial facet, central groove, and lateral facet. Sulcus angle at 30% and 40% flexion was also measured. Inter and intra observer measurement variabilities have been assessed. RESULTS. Varus-valgus rotation between the native and prosthetic trochleae was significantly different (p<0.001), with the prosthetic trochlear groove being on average 7.9 degrees more valgus. Medial and lateral facets and trochlear groove were significantly understuffed (3 to 6mm) postoperatively in the proximal two thirds of the trochlear, with greatest understuffing for the lateral facet (p<0.05). The mean medio-lateral translation and internal-external rotation of the groove and the sulcus angle showed no statistical differences, pre and postoperatively (figure 3). CONCLUSION. Kinematic alignment of Persona. ®. implants poorly restores native trochlear geometry. The clinical impact of this finding remains to be defined. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 144 - 144
1 Feb 2017
Matz J Lanting B Teeter M Howard J
Full Access

Introduction. Complications related to the patellofemoral joint continue to be a substantial source of patient morbidity, causing anterior knee pain, instability, and dysfunction following total knee arthroplasty. One of the principle factors affecting patellofemoral outcomes may be trochlear design. The optimal design is currently unknown. The purpose of the present study was to study patellofemoral joint contact by analysing areas of wear in retrieved femoral components of three modern designs. Materials and Methods. Eighteen retrieved femoral components featuring three different designs (constant radius of rotation, multiple radii of rotation, and multiple radii of rotation with built-in external rotation design) were matched on the basis of time-in-vivo, age, BMI and gender. All implants were cobalt chrome, posterior stabilized, cemented components with fixed bearing design with a resurfaced patella. Trochlear wear and surface damage were assessed using visual inspection, low-magnification light microscopy, and light profilometry. Results. Six implants from each group were successfully matched and were used for the topographical analysis. The femoral components were closely matched on the basis of time-in-vivo (TIV) (2.4 years±1.2), age (71.6 years±11.3), and BMI (33.0 kg/m. 2. ±7.0). There were 9 males and 9 females in the sample. Infection was the most common reason for revision (n=14) followed by instability (n=3) and loosening (n=1). There were no significant differences in TIV, age, and BMI between the groups (p=0.366, p=0.829, and p=0.586, respectively). When compared with unused, reference components, both the retrieved constant radius implants (p<0.05) and multiple radii implants (p<0.05) were significantly rougher than the new components. The retrieved components with multiple radii and built-in external rotation were not substantially rougher than the reference component (p>0.05). Visual inspection of the femoral components showed evidence of damage in all implant types. Modes of damage included scratches, striation, pitting, and delamination. No significant differences between the groups were found with respect to overall damage and wear on visual inspection (p=0.480). However, light profilometry analysis showed significantly increased roughness of multiple radii components compared to constant radius or multiple radii components with built-in external rotation (p<0.05). This was particularly significant in the proximal middle (p=0.045) and medial zones of the trochlea (p=0.017). Conclusions. All retrieved femoral components show evidence of damage in the trochlear area. While retrieved constant radius and multiple radii components showed increased wear compared to new components, retrieved components with multiple radii and built-in external rotation did not differ significantly from their new state. Retrieved multiple radii components appeared to have increased roughness compared with constant radius or multiple radii with built-in external rotation, particularly in the proximal zones of the trochlea. The long term effects of increased trochlear roughness requires further investigation and correlation with clinical outcomes. As the volume and patient demands for total knee arthroplasty increase, a greater understanding of the effect of trochlear design on clinical outcomes is warranted